TY - THES A1 - Ames, Christopher T1 - Molecular Beam Epitaxy of 2D and 3D HgTe, a Topological Insulator T1 - Molekularstrahlepitaxie von 2D und 3D HgTe, ein topologischer Isolator N2 - In the present thesis the MBE growth and sample characterization of HgTe structures is investigated and discussed. Due to the first experimental discovery of the quantum Spin Hall effect (QSHE) in HgTe quantum wells, this material system attains a huge interest in the spintronics society. Because of the long history of growing Hg-based heterostructures here at the Experimentelle Physik III in Würzburg, there are very good requirements to analyze this material system more precisely and in new directions. Since in former days only doped HgTe quantum wells were grown, this thesis deals with the MBE growth in the (001) direction of undoped HgTe quantum wells, surface located quantum wells and three dimensional bulk layers. All Hg-based layers were grown on CdTe substrates which generate strain in the layer stack and provide therefore new physical effects. In the same time, the (001) CdTe growth was investigated on n-doped (001) GaAs:Si because the Japanese supplier of CdTe substrates had a supply bottleneck due to the Tohoku earthquake and its aftermath in 2011. After a short introduction of the material system, the experimental techniques were demonstrated and explained explicitly. After that, the experimental part of this thesis is displayed. So, the investigation of the (001) CdTe growth on (001) GaAs:Si is discussed in chapter 4. Firstly, the surface preparation of GaAs:Si by oxide desorption is explored and analyzed. Here, rapid thermal desorption of the GaAs oxide with following cool down in Zn atmosphere provides the best results for the CdTe due to small holes at the surface, while e.g. an atomic flat GaAs buffer deteriorates the CdTe growth quality. The following ZnTe layer supplies the (001) growth direction of the CdTe and exhibits best end results of the CdTe for 30 seconds growth time at a flux ratio of Zn/Te ~ 1/1.2. Without this ZnTe layer, CdTe will grow in the (111) direction. However, the main investigation is here the optimization of the MBE growth of CdTe. The substrate temperature, Cd/Te flux ratio and the growth time has to be adjusted systematically. Therefore, a complex growth process is developed and established. This optimized CdTe growth process results in a RMS roughness of around 2.5 nm and a FWHM value of the HRXRD w-scan of 150 arcsec. Compared to the literature, there is no lower FWHM value traceable for this growth direction. Furthermore, etch pit density measurements show that the surface crystallinity is matchable with the commercial CdTe substrates (around 1x10^4 cm^(-2)). However, this whole process is not completely perfect and offers still room for improvements. The growth of undoped HgTe quantum wells was also a new direction in research in contrast to the previous n-doped grown HgTe quantum wells. Here in chapter 5, the goal of very low carrier densities was achieved and therefore it is now possible to do transport experiments in the n - and p - region by tuning the gate voltage. To achieve this high sample quality, very precise growth of symmetric HgTe QWs and their HRXRD characterization is examined. Here, the quantum well thickness can now determined accurate to under 0.3 nm. Furthermore, the transport analysis of different quantum well thicknesses shows that the carrier density and mobility increase with rising HgTe layer thickness. However, it is found out that the band gap of the HgTe QW closes indirectly at a thickness of 11.6 nm. This is caused by the tensile strained growth on CdTe substrates. Moreover, surface quantum wells are studied. These quantum wells exhibit no or a very thin HgCdTe cap. Though, oxidization and contamination of the surface reduces here the carrier mobility immensely and a HgCdTe layer of around 5 nm provides the pleasing results for transport experiments with superconductors connected to the topological insulator [119]. A completely new achievement is the realization of MBE growth of HgTe quantum wells on CdTe/GaAs:Si substrates. This is attended by the optimization of the CdTe growth on GaAs:Si. It exposes that HgTe quantum wells grown in-situ on optimized CdTe/GaAs:Si show very nice transport data with clear Hall plateaus, SdH oscillations, low carrier densities and carrier mobilities up to 500 000 cm^2/Vs. Furthermore, a new oxide etching process is developed and analyzed which should serve as an alternative to the standard HCl process which generates volcano defects at some time. However, during the testing time the result does not differ in Nomarski, HRXRD, AFM and transport measurements. Here, long-time tests or etching and mounting in nitrogen atmosphere may provide new elaborate results. The main focus of this thesis is on the MBE growth and standard characterization of HgTe bulk layers and is discussed in chapter 6. Due to the tensile strained growth on lattice mismatched CdTe, HgTe bulk opens up a band gap of around 22 meV at the G-point and exhibits therefore its topological surface states. The analysis of surface condition, roughness, crystalline quality, carrier density and mobility via Nomarski, AFM, XPS, HRXRD and transport measurements is therefore included in this work. Layer thickness dependence of carrier density and mobility is identified for bulk layer grown directly on CdTe substrates. So, there is no clear correlation visible between HgTe layer thickness and carrier density or mobility. So, the carrier density is almost constant around 1x10^11 cm^(-2) at 0 V gate voltage. The carrier mobility of these bulk samples however scatters between 5 000 and 60 000 cm^2/Vs almost randomly. Further experiments should be made for a clearer understanding and therefore the avoidance of unusable bad samples.But, other topological insulator materials show much higher carrier densities and lower mobility values. For example, Bi2Se3 exhibits just density values around 1019 cm^(-2) and mobility values clearly below 5000 cm2/Vs. The carrier density however depends much on lithography and surface treatment after growth. Furthermore, the relaxation behavior and critical thickness of HgTe grown on CdTe is determined and is in very good agreement with theoretical prediction (d_c = 155 nm). The embedding of the HgTe bulk layer between HgCdTe layers created a further huge improvement. Similar to the quantum well structures the carrier mobility increases immensely while the carrier density levels at around 1x10^11 cm^(-2) at 0 V gate voltage as well. Additionally, the relaxation behavior and critical thickness of these barrier layers has to be determined. HgCdTe grown on commercial CdTe shows a behavior as predicted except the critical thickness which is slightly higher than expected (d_c = 850 nm). Otherwise, the relaxation of HgCdTe grown on CdTe/GaAs:Si occurs in two parts. The layer is fully strained up to 250 nm. Between 250 nm and 725 nm the HgCdTe film starts to relax randomly up to 10 %. The relaxation behavior for thicknesses larger than 725 nm occurs than linearly to the inverse layer thickness. A explanation is given due to rough interface conditions and crystalline defects of the CdTe/GaAs:Si compared to the commercial CdTe substrate. HRXRD and AFM data support this statement. Another point is that the HgCdTe barriers protect the active HgTe layer and because of the high carrier mobilities the Hall measurements provide new transport data which have to be interpreted more in detail in the future. In addition, HgTe bulk samples show very interesting transport data by gating the sample from the top and the back. It is now possible to manipulate the carrier densities of the top and bottom surface states almost separately. The back gate consisting of the n-doped GaAs substrate and the thick insulating CdTe buffer can tune the carrier density for Delta(n) ~ 3x10^11 cm^(-2). This is sufficient to tune the Fermi energy from the p-type into the n-type region [138]. In this thesis it is shown that strained HgTe bulk layers exhibit superior transport data by embedding between HgCdTe barrier layers. The n-doped GaAs can here serve as a back gate. Furthermore, MBE growth of high crystalline, undoped HgTe quantum wells shows also new and extended transport output. Finally, it is notable that due to the investigated CdTe growth on GaAs the Hg-based heterostructure MBE growth is partially independent from commercial suppliers. N2 - In der vorliegenden Dissertation wurde das MBE-Wachstum von HgTe Strukturen erforscht und die anschließende Probencharakterisierung durchgeführt und diskutiert. Durch die erste experimentelle Entdeckung des Quanten-Spin-Hall-Effekts (QSHE) in HgTe Quantentrögen hat dieses Materialsystem großes Interesse im Gebiet der Spintronics erfahren. Aufgrund der langen Wachstumshistorie von quecksilberbasierenden Heterostrukturen am Lehrstuhl Experimentelle Physik III der Universität Würzburg sind die Voraussetzungen ausgesprochen gut, um dieses Materialsystem sehr ausführlich und auch in neue Richtungen hin zu untersuchen. Da vor dieser Doktorarbeit fast ausschließlich dotierte HgTe Quantentröge auf verschiedenen Substratorientierungen gewachsen wurden, beschäftigte sich diese Dissertation nun mit dem MBE-Wachstum von undotierten HgTe Quantentrögen, oberflächennahen Quantentrögen und dreidimensionalen Volumenkristallen. Alle quecksilberbasierenden Schichten wurden hierzu auf CdTe Substraten gewachsen, welche tensile Verspannung in den Schichten erzeugten und lieferten daher neue physikalische Effekte. In der selben Zeit wurde weiterhin das Wachstum von (001) CdTe auf n-dotiertem (001) GaAs:Si erforscht, da der japanische Zulieferer der CdTe Substrate eine Lieferengpass hatte aufgrund des Tohoku Erdbebens und seinen verheerenden Folgen im Jahr 2011. Die Erforschung des MBE-Wachstums von (001) CdTe auf (001) GaAs:Si wird im Kapitel 4 behandelt. Zuerst wurde hier die Oberflächenvorbereitung des GaAs:Si Substrates durch thermische Desorption untersucht und ausgewertet. Es stellte sich heraus, dass schnelle, thermische Desorption des GaAs - Oxides mit anschließendem Abkühlen in Zn Atmosphäre die besten Ergebnisse für das spätere CdTe durch kleine Löcher an der Oberfläche liefert, während zum Beispiel ein glatter GaAs Puffer das CdTe Wachstum verschlechtert. Der folgende ZnTe Film verschafft die gewünschte (001) Wachstumsrichtung für CdTe und weist bei 30 Sekunden Wachstumszeit bei einem Flussverhältnis von Zn/Te ~ 1/1.2 die besten Endergebnisse für CdTe auf. Jedoch war die Haupterneuerung hier die Optimierung des CdTe Wachstums. Dafür wurde ein komplexer Wachstumsprozess entwickelt und etabliert. Dieser optimierte CdTe Wachstumsprozess lieferte Ergebnisse von einer RMS Rauigkeit von ungefähr 2.5 nm und FWHMWerte der HRXRD w-Scans von 150 arcsec. Die Defektätzdichte-Messung zeigte weiterhin, dass die Oberflächenkristallinität vergleichbar mit kommerziell erwerbbaren CdTe Substraten ist (um 1x10^4 cm^(-2)). Des Weiteren ist kein niedrigerer Wert für die Halbwertsbreite des w-Scans in der Literatur für diese Wachstumsrichtung aufgeführt. Dies spiricht ebenfalls für die hohe Qualität der Schichten. Jedoch ist dieser Wachstumsprozess noch nicht endgültig ausgereift und bietet weiterhin noch Platz für Verbesserungen. Das Wachstum von undotierten HgTe Quantentrögen war ebenso eine neue Forschungsrichtung im Gegensatz zu den dotierten HgTe Quantentrögen, die in der Vergangenheit gewachsen wurden. Das Ziel hierbei, die Ladungsträgerdichte zu verringern, wurde erreicht und daher ist es nun möglich, Transportexperimente sowohl im n- als auch im p-Regime durchzuführen, indem eine Gatespannung angelegt wird. Des Weiteren experimentierten andere Arbeitsgruppen mit diesen Quantentrögen, bei denen die Fermi Energie in der Bandlücke liegt [143]. Außerdem wurde das sehr präzise MBE Wachstum anhand von symmetrischen HgTe Quantentrögen und ihren HRXRD Charakterisierungen behandelt. Daher kann nun die Quantentrogdicke präzise auf 0,3 nm angegeben werden. Die Transportergebnisse von verschieden dicken Quantentrögen zeigten, dass die Ladungsträgerdichte und Beweglichkeit mit steigender HgTe Schichtdicke zunimmt. Jedoch wurde auch herausgefunden, dass sich die Bandlücke von HgTe Quantentrögen indirekt bei einer Dicke von 11.6 nm schließt. Dies wird durch das verspannte Wachstum auf CdTe Substraten verursacht. Überdies wurden oberflächennahe Quantentröge untersucht. Diese Quantentröge besitzen keine oder nur eine sehr dünne HgCdTe Deckschicht. Allerdings verringerte Oxidation und Oberflächenverschmutzung hier die Ladungsträgerbeweglichkeit dramatisch und eine HgCdTe Schicht von ungefähr 5 nm lieferte ansprechende Transportergebnisse für Supraleiter, die den topologischen Isolator kontaktieren. Eine komplett neue Errungenschaft war die Realisierung, via MBE, HgTe Quantentröge auf CdTe/GaAs:Si Substrate zu wachsen. Dies ging einher mit der Optimierung des CdTe Wachstums auf GaAs:Si. Es zeigte sich, dass HgTe Quantentröge, die in-situ auf optimierten CdTe/GaAs:Si gewachsen wurden, sehr schöne Transportergebnisse mit deutlichen Hall Quantisierungen, SdH Oszillationen, niedrigen Ladungsträgerdichten und Beweglichkeiten bis zu 500 000 cm^2/Vs erreichen. Des Weiteren wurde ein neues Oxidätzverfahren entwickelt und untersucht, welches als Alternative zum Standard-HCl-Prozess dienen sollte, da dieses manchmal vulkan-artige Defekte hervorruft. Jedoch ergab sich kein Unterschied in den Nomarski, HRXRD, AFM und Transportexperimenten. Hier könnten vielleicht Langzeittests oder Ätzen und Befestigen in Stickstoffatmosphäre neue, gewinnbringende Ergbnisse aufzeigen. Der Hauptfokus dieser Doktorarbeit lag auf dem MBE Wachstum und der Standardcharakterisierung von HgTe Volumenkristallen und wurde in Kapitel 6 diskutiert. Durch das tensil verpannte Wachstum auf CdTe entsteht für HgTe als Volumenkristall eine Bandlücke von ungefähr 22 meV am G Punkt und zeigt somit seine topologischen Oberflächenzustände. Die Analyse der Oberfächenbeschaffenheit, der Rauigkeit, der kristallinen Qualität, der Ladungsdrägerdichte und Beweglichkeit mit Hilfe von Nomarski, AFM, XPS, HRXRD und Transportmessungen ist in dieser Arbeit anzutreffen. Außerdem wurde die Schichtdickenabhängigkeit von Ladungsträgerdichte und Beweglichkeit von HgTe Volumenkristallen, die direkt auf CdTe Substraten gewachsen wurden, ermittelt worden. So erhöhte sich durchschnittlich die Dichte und Beweglichkeit mit zunehmender HgTe Schichtdicke, aber die Beweglichkeit ging selten über μ ~ 40 000 cm^2/Vs hinaus. Die Ladungsträgerdichte n hing jedoch sehr von der Litographie und der Behandlung der Oberfläche nach dem Wachstum ab. Des Weiteren wurde das Relaxationsverhalten und die kritische Dicke bestimmt, welches sehr gut mit den theoretischen Vorhersagen übereinstimmt (dc = 155 nm). Das Einbetten des HgTe Volumenkristalls in HgCdTe Schichten brachte eine weitere große Verbesserung mit sich. Ähnlich wie bei den Quantentrögen erhörte sich die Beweglichkeit μ immens, während sich die Ladungsträgerdichte bei ungefähr 1x10^11 cm^(-2) einpendelte. Zusätzlich wurde auch hier das Relaxationsverhalten und die kritische Schichtdicke dieser Barrierenschichten ermittelt. HgCdTe, gewachsen auf kommerziellen CdTe Substraten, zeigte ein Verhalten ähnlich zu dem Erwarteten mit der Ausnahme, dass die kritische Schichtdicke leicht höher ist als die Vorhergesagte (dc = 850 nm). Auf der anderen Seite findet die Relaxation von HgCdTe auf CdTe/GaAs:Si zweigeteilt ab. Bis 250 nm ist die Schicht noch voll verspannt. Zwischen 250 nm und 725 nm beginnt die HgCdTe Schicht willkürlich bis zu 10 % zu relaxieren. Das Relaxationsverhalten für Dicken über 725 nm findet dann wieder linear zur invers aufgetragenen Schichtdicke statt. Eine Erklärung wurde durch das raue Interface der Schichten und der Defekte im Kristall von CdTe/GaAs:Si gegeben, im Vergleich zu den kommerziellen CdTe Substraten. HRXRD und AFM Ergebnisse belegten diese Aussage. Die HgCdTe Barrieren schützen die aktive HgTe Schicht und daher liegen nach Hall Messungen aufgrund der hohen Ladungsträgerbeweglichkeiten neue Transportergbnisse vor, welche in der Zukunft ausführlicher interpretiert werden müssen. Darüber hinaus zeigten HgTe Volumenkristalle neue, interessante Transportergebnisse durch das gleichzeitige Benutzen eines Top- und Backgates. Es ist nun möglich, die Ladungsträger der oberen und unteren Oberflächenzustände nahezu getrennt zu verändern und zu ermitteln. Das Backgate, bestehend aus dem n-dotierten GaAs:Si Substrate und dem dicken isolierenden CdTe Puffer, kann die Ladungsträgerdichte um ungefähr Delta(n) ~ 3x10^11 cm^(-2) varieren. Das ist ausreichend, um die Fermi Energie vom p- in den n-Bereich einzustellen [138]. In dieser Dissertation wurde also gezeigt, dass verspannte HgTe Volumenkristalle durch das Einbetten in HgCdTe Barrieren neue Transportergebnisse liefern. Das n-dotierte GaAs konnte hierbei als Backgate genutzt werden. Des Weiteren zeigte das MBE Wachstum von hochkristallinen , undotiereten HgTe Quantentrögen ebenso neue und erweiterte Transportergebnisse. Zuletzt ist es bemerkenswert, dass durch das erforschte CdTe Wachstum auf GaAs das MBE Wachstum von quecksilberbasierenden Heterostrukturen auf CdTe Substraten teilweise unabhänigig ist von kommerziellen Zulieferbetrieben. KW - Quecksilbertellurid KW - Topologischer Isolator KW - MBE KW - HgTe KW - topological insulator KW - Molekularstrahlepitaxie Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-151136 ER - TY - THES A1 - Breuer [geb. Hemberger], Kathrin R. F. T1 - Effiziente 3D Magnetresonanzbildgebung schnell abfallender Signale T1 - Efficient 3D Magnetic Resonance Imaging of fast decaying signals N2 - In der vorliegenden Arbeit wird die Rotated-Cone-UTE-Sequenz (RC-UTE), eine 3D k-Raum-Auslesetechnik mit homogener Verteilung der Abtastdichte, vorgestellt. Diese 3D MR-Messtechnik ermöglicht die für die Detektion von schnell abfallenden Signalen notwendigen kurzen Echozeiten und weist eine höhere SNR-Effizienz als konventionelle radiale Pulssequenzen auf. Die Abtastdichte ist dabei in radialer und azimutaler Richtung angepasst. Simulationen und Messungen in vivo zeigen, dass die radiale Anpassung das T2-Blurring reduziert und die SNR-Effizienz erhöht. Die Drehung der Trajektorie in azimutale Richtung ermöglicht die Reduzierung der Unterabtastung bei gleicher Messzeit bzw. eine Reduzierung der Messzeit ohne Auflösungsverlust. Die RC-UTE-Sequenz wurde erfolgreich für die Bildgebung des Signals des kortikalen Knochens und der Lunge in vivo angewendet. Im Vergleich mit der grundlegenden UTE-Sequenz wurden die Vorteile von RC-UTE in allen Anwendungsbeispielen aufgezeigt. Die transversalen Relaxationszeit T2* des kortikalen Knochen bei einer Feldstärke von 3.0T und der Lunge bei 1.5T und 3.0T wurde in 3D isotroper Auflösung gemessen. Außerdem wurde die Kombination von RC-UTE-Sequenz mit Methoden der Magnetisierungspräparation zur besseren Kontrasterzeugung gezeigt. Dabei wurden die Doppel-Echo-Methode, die Unterdrückung von Komponenten mit langer Relaxationszeit T2 durch Inversionspulse und der Magnetisierungstransfer-Kontrast angewendet. Die Verwendung der RC-UTE-Sequenz für die 3D funktionelle Lungenbildgebung wird ebenfalls vorgestellt. Mit dem Ziel der umfassenden Charakterisierung der Lungenfunktion in 3D wurde die simultane Messung T1-gewichteter Bilder und quantitativer T2*-Karten für verschiedene Atemzustände an sechs Probanden durchgeführt. Mit der hier vorgestellten Methode kann die Lungenfunktion in 3D über T1-Wichtung, quantitative T2*-Messung und Rekonstruktion verschiedener Atemzustände durch Darstellung von Ventilation, Sauerstofftransport und Volumenänderung beurteilt werden. N2 - In this thesis the Rotated-Cone-UTE-sequence (RC-UTE), a 3D k- space sampling scheme with uniform sampling density, is presented. 3D RC-UTE provides short echo times enabling the detection of fast decaying signals with higher SNR-efficiency than conventional UTE sequences. In RC-UTE the sampling density is adapted in radial and azimuthal direction. It is shown in simulations and measurements that the density adaption along the radial dimension reduces T2-blurring. By twisting the trajectory along the azimuthal direction fewer projections are needed to fulfill the Nyquist criterion. Thereby, undersampling artefacts or the measurement time is reduced without loss of resolution. RC-UTE has been successfully applied in vivo in cortical bone and the lung. It was shown that the RC-UTE sequence outperforms the standard UTE sequence in all presented applications. In addition, the transversal relaxation time T2* of cortical bone at field strength of 3.0T and the human lung at 1.5T und 3.0T was measured in 3D isotropic resolution. Moreover, the combination of RC-UTE with magnetization preparation techniques for improved image contrast was shown. To this end strategies such as double-echo readout, long T2 suppression by inversion pulses and magnetization transfer contrast imaging were employed. Furthermore, the application of RC-UTE for 3D functional lung imaging is presented. In order to provide broad information about pulmonary function T1-weighted images and quantitative T2*-maps in different breathing states were simultaneously measured in six healthy volunteers. The presented methodology enables the assessment of pulmonary function in 3D by indicating ventilation, oxygen transfer and lung volume changes during free breathing. KW - Kernspintomografie KW - Relaxationszeit KW - Dreidimensionale Bildverarbeitung KW - T2* KW - Ulrakurze Echozeit KW - T1-Wichtung KW - dichteangepasste k-Raum Abtastung KW - Lunge KW - Relaxation KW - Lungenfunktion Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-150750 ER - TY - THES A1 - Schwarz, Christoph Benjamin T1 - Full vector-field control of femtosecond laser pulses with an improved optical design T1 - Vollständige Kontrolle des Vektorfelds von Femtosekunden-Laserpulsen mit einem verbesserten optischen Design N2 - The controlled shaping of ultrashort laser pulses is a powerful technology and applied in many laser laboratories today. Most of the used pulse shapers are only able to produce linearly polarized pulses shaped in amplitude and phase. Some devices are also capable of producing limited time-varying polarization profiles, but they are not able to control the amplitude. However, for some state-of-the-art non-linear time-resolved methods, such as polarization-enhanced two-dimensional spectroscopy, the possibility of controlling the amplitude and the polarization simultaneously is desirable. Over the last years, different concepts have been developed to overcome these restrictions and to manipulate the complete vector-field of an ultrashort laser pulse with independent control over all four degrees of freedom - phase, amplitude, orientation, and ellipticity. The aim of this work was to build such a vector-field shaper. While the basic concept used for our setup is based on previous designs reported in the literature, the goal was to develop an optimized optical design that minimizes artifacts, allowing for the generation of predefined polarization pulse sequences with the highest achievable accuracy. In Chapter 3, different approaches reported in the literature for extended and unrestricted vector-field control were examined and compared in detail. Based on this analysis, we decided to follow the approach of modulating the spectral phase and amplitude of two perpendicularly polarized pulses independently from each other in two arms of an interferometer and recombining them to a single laser pulse to gain control over the complete vector field. As described in Chapter 4, the setup consists of three functional groups: i) an optical component to generate and recombine the two polarized beams, ii) a 4f setup, and iii) a refracting telescope to direct the two beams under two different angles of incidence onto the grating of the 4f setup in a common-path geometry. This geometry was chosen to overcome potential phase instabilities of an interferometric vector-field shaper. Manipulating the two perpendicularly polarized pulses simultaneously within one 4f setup and using adjacent pixel groups of the same liquid-crystal spatial light modulator (LC SLM) for the two polarizations has the advantages that only a single dual-layer LC SLM is required and that a robust and compact setup was achieved. The shaping capabilities of the presented design were optimized by finding the best parameters for the setup through numerical calculations to adjust the frequency distributions for a broad spectrum of 740 – 880 nm. Instead of using a Wollaston prism as in previous designs, a thin-film polarizer (TFP) is utilized to generate and recombine the two orthogonally polarized beams. Artifacts such as angular dispersion and phase distortions along the beam profile which arise when a Wollaston prism is used were discussed. Furthermore, it was shown by ray-tracing simulations that in combination with a telescope and the 4f setup, a significant deformation of the beam profile would be present when using a Wollaston prism since a separation of the incoming and outgoing beam in height is needed. The ray-tracing simulations also showed that most optical aberrations of the setup are canceled out when the incoming and outgoing beams propagate in the exact same plane by inverting the beam paths. This was realized by employing a TFP in the so-called crossed-polarizer arrangement which has also the advantage that the polarization-dependent efficiencies of the TFP and the other optics are automatically compensated and that a high extinction ratio in the order of 15000:1 is reached. Chromatic aberrations are, however, not compensated by the crossed-polarizer arrangement. The ray-tracing simulations confirmed that these chromatic aberrations are mainly caused by the telescope and not by the cylindrical lens of the 4f setup. Nevertheless, in the experimentally used wavelength range of 780 – 816 nm, only minor distortions of the beam profile were observed, which were thus considered to be negligible in the presented setup. The software implementation of the pulse shaper was reviewed in Chapter 5 of this thesis. In order to perform various experiments, five different parameterizations, accounting for the extended shaping capabilities of a vector-field shaper, were developed. The Pixel Basis, the Spectral Basis, and the Spectral Taylor Basis can generally be used in combination with an optimization algorithm and are therefore well suited for quantum control experiments. For multidimensional spectroscopy, the Polarized Four-Pulse Basis was established. With this parameterization pulse sequences with up to four subpulses can be created. The polarization state of each subpulse can be specified and the relative intensity, phase, and temporal delay between consecutive subpulses can be controlled. In addition, different software programs were introduced in Chapter 5 which are required to perform the experiments conducted in this work. The experimental results were presented in Chapter 6. The frequency distribution across the LC SLM was measured proving that the optimal frequency distribution was realized experimentally. Furthermore, the excellent performance of the TFP was verified. In general, satellite pulses are emitted from the TFP due to multiple internal reflections. Various measurements demonstrated that these pulses are temporally separated by at least 4.05 ps from the main pulse and that they have vanishing intensity. The phase stability between the two arms of the presented common-path setup σ = 28.3 mrad (λ/222) over 60 minutes. To further improve this stability over very long measurement times, an on-the-fly phase reduction and stabilization (OPRAS) routine utilizing the pulse shaper itself was developed. This routine automatically produces a compressed pulse with a minimized relative phase between the two polarization components. A phase stability of σ = 31.9 mrad (λ/197) over nearly 24 hours was measured by employing OPRAS. Various pulse sequences exceeding the capabilities of conventional pulse shapers were generated and characterized. The experimental results proved that shaped pulses with arbitrary phase, amplitude, and polarization states can be created. In all cases very high agreement between the target parameters and the experimental data was achieved. For the future use of the setup also possible modifications were suggested. These are not strictly required, but all of them could further improve the performance and flexibility of the setup. Firstly, it was illustrated how a “dual-output” of the setup can be realized. With this modification it would be possible to use the main intensity of the shaped pulse for an experiment while using a small fraction to characterize the pulse or to perform OPRAS simultaneously. Secondly, the basic idea of replacing the telescope by focusing mirrors in order to eliminate the chromatic aberrations was presented. Regarding the different parameterizations for vector-field shaping, some modifications increasing the flexibility of the implemented bases and the realization of a von Neumann Basis for the presented setup were proposed. In future experiments, the vector-field shaper will be used in conjunction with a photoemission electron microscope (PEEM). This approach combines the temporal resolution provided by ultrashort laser pulses with the high spatial resolution gained by electron microscopy in order to perform two-dimensional spectroscopy and coherent control on nanostructures with polarization-shaped femtosecond laser pulses. In combination with other chiral-sensitive experimental setups implemented earlier in our group, the vector-field shaper opens up new perspectives for chiral femtochemistry and chiral control. The designed vector-field shaper meets all requirements to generate high-precision polarization-shaped multipulse sequences. These can be used to perform numerous polarization-sensitive experiments. Employing the OPRAS routine, a quasi-infinitely long phase stability is achieved and complex and elaborated long-term measurements can be carried out. The fact that OPRAS demands no additional hardware and that only a single dual-layer LC SLM and inexpensive optics are required allows the building of a vector-field shaper at comparatively low costs. We hope that with the detailed insights into the optical design process as well as into the software implementation given in this thesis, vector-field shaping will become a standard technique just as conventional pulse shaping in the upcoming years. N2 - Die gezielte Formung ultrakurzer Laserpulse ist eine leistungsstarke Technik, die heutzutage in vielen Laserlaboren eingesetzt wird. Die meisten Pulsformer können jedoch nur linear polarisierte, in Phase und Amplitude geformte Laserpulse erzeugen. Einige Pulsformer können auch sich zeitlich verändernde Polarisationszustände generieren. Die möglichen Polarisationszustände sind allerdings beschränkt und eine gleichzeitige Formung der Amplitude ist dann nicht mehr möglich. Für einige moderne, nicht-lineare, zeitaufgelöste, spektroskopische Methoden, wie z.B. die polarisationsunterstützte zweidimensionale Spektroskopie, ist aber die gleichzeitige Kontrolle über die Polarisation und die Amplitude erstrebenswert. In den letzten Jahren wurden verschiedene Konzepte entwickelt, um diese Beschränkungen zu überwinden und eine vollständige Kontrolle des Vektorfeldes über die vier Freiheitsgrade Phase, Amplitude, Orientierung und Elliptizität eines ultrakurzen Laserpulses zu erlangen. Ziel dieser Arbeit war es, einen solchen Vektorfeldformer zu konstruieren. Die Grundidee für das Design unseres Aufbaus basiert auf verschiedenen literaturbekannten Konzepten. Unser Ziel war es jedoch, ein optimiertes Design zu entwickeln, bei dem Formungsartefakte minimal sind und definierte polarisationsgeformte Mehrfachpulse mit der höchstmöglichen Genauigkeit erzeugt werden können. In Kapitel 3 wurden verschiedene vorherige Ansätze für die erweiterte und vollständige Vektorfeldkontrolle detailliert geprüft und verglichen. Basierend auf dieser Analyse haben wir uns dazu entschlossen, das Konzept eines interferometrischen Vektorfeldformers zu verwenden. Bei diesem werden die spektrale Phase und Amplitude zweier orthogonal polarisierter Pulse unabhängig voneinander in den zwei Armen eines Interferometers manipuliert und durch Überlagerung dieser zwei Pulse die vollständige Kontrolle über das Vektorfeld erlangt. Wie in Kapitel 4 beschrieben, besteht der Aufbau aus drei funktionellen Gruppen: i) einer optischen Komponente, um die zwei polarisierten Strahlen zu erzeugen und zu rekombinieren, ii) einem sog. 4f-Aufbau und iii) einem Linsenteleskop, um die zwei Strahlen unter unterschiedlichen Winkeln auf das Gitter des 4f-Aufbaus zu lenken, so dass beide Strahlen über dieselben Optiken propagieren. Diese Art der Strahlführung wurde gewählt, um die interferometrische Stabilität des Aufbaus zu verbessern. Beide Strahlen werden mit demselben 4f-Aufbau geformt, indem unterschiedliche benachbarte Pixelbereiche des Flüssigkristall-Lichtmodulators (LC SLM, engl. liquid-crystal spatial light modulator) für die zwei Polarisationskomponenten genutzt werden. Das hat den Vorteil, dass nur ein einzelnes zweilagiges LC SLM benötigt wird und so ein kompakter und robuster Aufbau realisiert werden konnte. Um die Frequenzverteilung für einen breiten Spektralbereich von 740 – 880 nm anzupassen, wurden die besten Parameter für den Aufbau anhand numerischer Berechnungen bestimmt, und somit die Formungsmöglichkeiten unseres Vektorfeldformers optimiert. Im Gegensatz zu anderen Designs wird ein Dünnschicht-Polarisator (TFP, engl. thin-film polarizer) anstelle eine Wollaston-Prismas verwendet, um die zwei senkrecht zueinander polarisierten Strahlen zu erzeugen und zu rekombinieren, da ein Wollaston-Prisma Artefakte wie Winkelchirp und eine über das Strahlprofiel variierende Phase verursacht. Bei Verwendung eines Wollaston-Prismas muss zudem der rekombinierte Strahl gegenüber des einfallenden Strahls in der Höhe verkippt werden, um beide räumlich trennen zu können. Raytracing-Simulationen haben gezeigt, dass dies in Kombination mit einem Teleskop und dem 4f-Aufbau zu einer erheblichen Deformierung des Strahlprofiles führt. Diese Simulationen haben auch gezeigt, dass die Abbildungsfehler des Aufbaus weitestgehend aufgehoben werden, wenn der eingehende und ausgehende Strahl in derselben Ebene propagieren und somit die Strahlwege genau invertiert werden. Dies konnte mit Hilfe des TFPs in einer Konfiguration, die gekreuzten Polarisatoren entspricht, realisiert werden. Diese Konfiguration hat zudem den Vorteil, dass dadurch die polarisationsabhängige Effizienz des TFPs und der anderen Optiken automatisch kompensiert wird und ein hohes Auslöschungsverhältnis in der Größenordnung 15000:1 erzielt wird. Die chromatische Aberration wird allerdings durch diese Polarisator-Konfiguration nicht aufgehoben. Durch Raytracing wurde bestätigt, dass diese primär durch das Teleskop verursacht wird und nicht durch die Zylinderlinse des 4f-Aufbaus. Allerdings wurden im experimentell genutzten Wellenlängenbereich von 780 – 816 nm nur geringe Störungen des Strahlprofiles beobachtet, die daher als vernachlässigbar angesehen wurden. Die softwareseitige Umsetzung der Vektorfeldkontrolle wurde in Kapitel 5 beschrieben. Um verschiedene Experimente durchführen zu können, wurden fünf Parametrisierungen entwickelt, bei denen die erweiterten Formungsmöglichkeiten eines Vektorfeldformers berücksichtigt wurden. Die Pixel Basis, die Spectral Basis und die Spectral Taylor Basis können zusammen mit einem Optimierungsalgorithmus verwendet werden und sind damit bestens für Experimente der Quantenkontrolle geeignet. Für die multidimensionale Spektroskopie wurde die Polarized Four-Pulse Basis eingeführt. Mit dieser Parametrisierung können Mehrfach-Pulssequenzen mit bis zu vier Pulsen erzeugt werden. Dabei kann der Polarisationszustand jedes Pulses vorgegeben und die relative Intensität, Phase und der zeitliche Abstand aufeinanderfolgender Pulse festgelegt werden. Zusätzlich wurden in Kapitel 5 verschieden Softwareprogramme vorgestellt, die für die in dieser Arbeit durchgeführten Experimente notwendig sind. Die experimentellen Ergebnisse wurden in Kapitel 6 präsentiert. Die Frequenzverteilung am LC SLM wurde gemessen und dabei bewiesen, dass die optimale Frequenzverteilung experimentell realisiert werden konnte. Des Weiteren wurden die exzellenten Eigenschaften des TFPs bestätigt. Im Allgemeinen emittiert der TFP Satellitenpulse durch interne Mehrfachreflexe. Mehrere Messungen haben jedoch gezeigt, dass diese Satellitenpulse einen zeitlichen Abstand von mindesten 4,05 ps vom Hauptpuls aufweisen und dass deren Intensität verschwindend gering ist. Die Phasenstabilität des Aufbaus beträgt σ = 28,3 mrad (λ/222) über einen Zeitraum von einer Stunde. Um die Stabilität für sehr lange Messzeiten zu verbessern, wurde eine Routine zur Phasenreduktion und zur Stabilisierung (OPRAS, engl. on-the-fly phase reduction and stabilization) unter Einbeziehung des Pulsformers entwickelt. Diese Routine erzeugt automatisiert einen komprimierten Puls mit minimierter relativer Phase zwischen den zwei Polarisationskomponenten und ermöglicht so eine Phasenstabilität von σ = 31,9 mrad (λ/197) über nahezu 24 Stunden. Ferner wurden verschieden Pulssequenzen erzeugt und charakterisiert, die die Möglichkeiten der konventionellen Pulsformung übertreffen. Die experimentellen Ergebnisse zeigen, dass geformte Pulse mit beliebigen Phasen, Amplituden und Polarisationszuständen generiert werden können. In allen Fällen wurde eine sehr hohe Übereinstimmung zwischen den Zielparametern und den experimentellen Daten erreicht. Für den zukünftigen Einsatz des Aufbaus wurden mögliche Erweiterungen vorgeschlagen. Diese sind nicht zwingend erforderlich, könnten aber die Leistung und die Einsatzmöglichkeiten des Vektorfeldformers weiter verbessern. Erstens wurde aufgezeigt, wie zwei Ausgangsstrahlen erzeugt werden könnten. Mit dieser Veränderung wäre es möglich, den größten Teil der Intensität des geformten Strahls für ein Experiment zu nutzen und gleichzeitig einen geringen Anteil für die Pulscharakterisierung oder für die Phasenstabilisierung mit der entwickelten Routine zu verwenden. Um chromatische Aberration zu vermeiden, wurde zweitens die prinzipielle Idee, das Linsenteleskop durch fokussierende Spiegel zu ersetzen, diskutiert. Für die verschiedenen erarbeiteten Parametrisierungen zur Vektorfeldkontrolle wurden einige Erweiterungen vorgeschlagen, um deren Einsatzmöglichkeiten noch weiter zu erhöhen. Außerdem wurde noch die Möglichkeit einer von Neumann Basis für den präsentierten Aufbau aufgezeigt. In zukünftigen Experimenten wird unser Aufbau mit einem Photoemissionselektronenmikroskop (PEEM) kombiniert. Dadurch kann die zeitliche Auflösung ultrakurzer Laserpulse mit der hohen räumlichen Auflösung der Elektronenmikroskopie vereint werden, was die zweidimensionale Spektroskopie und Quantenkontrolle von Nanostrukturen mit Hilfe polarisationsgeformter Femtosekunden-Laserpulse ermöglicht. Der Vektorfeldformer eröffnet in Verbindung mit anderen zuvor in unserer Gruppe implementierten chiral sensitiven Versuchsaufbauten neue Perspektiven für die chirale Femtochemie und Kontrolle. Der erarbeitete Vektorfeldformer erfüllt alle Anforderungen, um polarisationsgeformte Mehrfachpulssequenzen mit hoher Präzision zu erzeugen. Diese können verwendet werden, um zahlreiche polarisationssensitive Experimente durchzuführen. Durch die Stabilisierungsroutine OPRAS wird eine quasi unendlich lange Phasenstabilität des Aufbaus gewährleistet und komplexe und aufwendige Langzeitmessungen können ausgeführt werden. Die Tatsache, dass OPRAS keine weitere Hardware benötigt und der Aufbau nur einen einzigen zweilagigen Flüssigkristall-Lichtmodulator sowie ansonsten verhältnismäßig günstige Optiken erfordert, ermöglicht den Bau eines Vektorfeldformers zu vergleichsweise niedrigen Kosten. Wir hoffen, dass andere Forschergruppen von den detailreichen Einblicken in den Designprozess und die Software-Implementierung profitieren und dass die vollständige Vektorfeldformung in den nächsten Jahren genauso wie die konventionelle Pulsformung zu einer Standard-Technologie wird. KW - Ultrakurzer Lichtimpuls KW - vector-field shaper KW - vector-field control KW - polarization pulse shaping KW - femtosecond pulse shaping KW - Vektorfeldformer KW - Vektorfeldkontrolle KW - Polarisationspulsformung KW - Femtosekunden Pulsformung KW - Femtosekundenbereich KW - Impulsformung KW - Femtosekundenlaser Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-142948 ER - TY - JOUR T1 - Search for dark matter in events with heavy quarks and missing transverse momentum in pp collisions with the ATLAS detector JF - European Physical Journal C: Particles and Fields N2 - This article reports on a search for dark matter pair production in association with bottom or top quarks in 20.3 fb\(^{−1}\) of pp collisions collected at \(\sqrt {s}\) = 8 TeV by the ATLAS detector at the LHC. Events with large missing transverse momentum are selected when produced in association with high-momentum jets of which one or more are identified as jets containing b-quarks. Final states with top quarks are selected by requiring a high jet multiplicity and in some cases a single lepton. The data are found to be consistent with the Standard Model expectations and limits are set on the mass scale of effective field theories that describe scalar and tensor interactions between dark matter and Standard Model particles. Limits on the dark-matter–nucleon cross-section for spin-independent and spin-dependent interactions are also provided. These limits are particularly strong for low-mass dark matter. Using a simplified model, constraints are set on the mass of dark matter and of a coloured mediator suitable to explain a possible signal of annihilating dark matter. KW - dark matter KW - proton-proton collision KW - ATLAS detector Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-150089 VL - 75 IS - 2 ER - TY - JOUR T1 - Search for Higgs boson pair production in the b\(\overline{b}\)b\(\overline{b}\) final state from pp collisions at \(\sqrt {s}\) = 8 TeV with the ATLAS detector JF - European Physical Journal C: Particles and Fields N2 - A search for Higgs boson pair production pp → hh is performed with 19.5 fb\(^{−1}\) of proton–proton collision data at \(\sqrt {s}\) = 8 TeV, which were recorded by the ATLAS detector at the Large Hadron Collider in 2012. The decay products of each Higgs boson are reconstructed as a high-momentum b\(\overline{b}\) system with either a pair of small-radius jets or a single large-radius jet, the latter exploiting jet substructure techniques and associated b-tagged track-jets. No evidence for resonant or non-resonant Higgs boson pair production is observed. The data are interpreted in the context of the Randall–Sundrum model with a warped extra dimension as well as the two-Higgs-doublet model. An upper limit on the cross-section for pp → G\(^{*}_{KK}\) → hh → b\(\overline{b}\)b\(\overline{b}\) of 3.2(2.3) fb is set for a Kaluza–Klein graviton G\(^{*}_{KK}\) mass of 1.0(1.5) TeV, at the 95 % confidence level. The search for non-resonant Standard Model hh production sets an observed 95 % confidence level upper limit on the production cross-section σ(pp → hh → b\(\overline{b}\)b\(\overline{b}\)) of 202 fb, compared to a Standard Model prediction of σ(pp → hh → b\(\overline{b}\)b\(\overline{b}\)) = 3.6±0.5 fb. KW - Higgs boson KW - proton-proton collision KW - ATLAS detector KW - pair production Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-150119 VL - 75 IS - 9 ER - TY - JOUR T1 - Search for invisible decays of the Higgs boson produced in association with a hadronically decaying vector boson in pp collisions at \(\sqrt {s}\) = TeV with the ATLAS detector JF - European Physical Journal C: Particles and Fields N2 - A search for Higgs boson decays to invisible particles is performed using 20.3 fb\(^{−1}\) of pp collision data at a centre-of-mass energy of 8 TeV recorded by the ATLAS detector at the Large Hadron Collider. The process considered is Higgs boson production in association with a vector boson (V = W or Z) that decays hadronically, resulting in events with two or more jets and large missing transverse momentum. No excess of candidates is observed in the data over the background expectation. The results are used to constrain VH production followed by H decaying to invisible particles for the Higgs boson mass range 115 < m\(_{H}\) < 300 GeV. The 95 % confidence-level observed upper limit on σ\(_{VH}\) × BR(H → inv.) varies from 1.6 pb at 115 GeV to 0.13 pb at 300 GeV. Assuming Standard Model production and including the gg → H contribution as signal, the results also lead to an observed upper limit of 78 % at 95 % confidence level on the branching ratio of Higgs bosons decays to invisible particles at a mass of 125 GeV. KW - Higgs boson KW - ATLAS detector KW - decays Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-150126 VL - 75 IS - 7 ER - TY - JOUR T1 - Search for invisible particles produced in association with single-top-quarks in proton-proton collisions at \(\sqrt {s}\) = 8 TeV with the ATLAS detector JF - European Physical Journal C: Particles and Fields N2 - A search for the production of single-top-quarks in association with missing energy is performed in proton–proton collisions at a centre-of-mass energy of \(\sqrt {s}\) =8 TeV with the ATLAS experiment at the large hadron collider using data collected in 2012, corresponding to an integrated luminosity of 20.3 fb\(^{−1}\). In this search, the W boson from the top quark is required to decay into an electron or a muon and a neutrino. No deviation from the standard model prediction is observed, and upper limits are set on the production cross-section for resonant and non-resonant production of an invisible exotic state in association with a right-handed top quark. In the case of resonant production, for a spin-0 resonance with a mass of 500 GeV, an effective coupling strength above 0.15 is excluded at 95 % confidence level for the top quark and an invisible spin-1/2 state with mass between 0 and 100 GeV. In the case of non-resonant production, an effective coupling strength above 0.2 is excluded at 95 % confidence level for the top quark and an invisible spin-1 state with mass between 0 and 657 GeV. KW - single-top-quarks KW - proton-proton collision KW - ATLAS detector Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-150134 VL - 75 IS - 2 ER - TY - JOUR T1 - Search for metastable heavy charged particles with large ionisation energy loss in pp collisions at \(\sqrt {s}\) = 8 TeV using the ATLAS experiment JF - European Physical Journal C: Particles and Fields N2 - Many extensions of the Standard Model predict the existence of charged heavy long-lived particles, such as R-hadrons or charginos. These particles, if produced at the Large Hadron Collider, should be moving non-relativistically and are therefore identifiable through the measurement of an anomalously large specific energy loss in the ATLAS pixel detector. Measuring heavy long-lived particles through their track parameters in the vicinity of the interaction vertex provides sensitivity to metastable particles with lifetimes from 0.6 ns to 30 ns. A search for such particles with the ATLAS detector at the Large Hadron Collider is presented, based on a data sample corresponding to an integrated luminosity of 18.4 fb\(^{−1}\) of pp collisions at \(\sqrt {s}\) = 8 TeV. No significant deviation from the Standard Model background expectation is observed, and lifetime-dependent upper limits on R-hadrons and chargino production are set. Gluino R-hadrons with 10 ns lifetime and masses up to 1185 GeV are excluded at 95 % confidence level, and so are charginos with 15 ns lifetime and masses up to 482 GeV. KW - ATLAS detector KW - charged heavy long-lived particles KW - proton-proton collision Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-150149 VL - 75 IS - 9 ER - TY - JOUR T1 - Search for new phenomena in final states with an energetic jet and large missing transverse momentum in pp collisions at \(\sqrt {s}\) = 8 TeV with the ATLAS detector JF - European Physical Journal C: Particles and Fields N2 - Results of a search for new phenomena in final states with an energetic jet and large missing transverse momentum are reported. The search uses 20.3 fb\(^{−1}\) of \(\sqrt {s}\) = 8 TeV data collected in 2012 with the ATLAS detector at the LHC. Events are required to have at least one jet with pT > 120 GeV and no leptons. Nine signal regions are considered with increasing missing transverse momentum requirements between E\(^{miss}_{T}\) > 150 GeV and E\(^{miss}_{T}\) > 700 GeV. Good agreement is observed between the number of events in data and Standard Model expectations. The results are translated into exclusion limits on models with either large extra spatial dimensions, pair production of weakly interacting dark matter candidates, or production of very light gravitinos in a gauge-mediated supersymmetric model. In addition, limits on the production of an invisibly decaying Higgs-like boson leading to similar topologies in the final state are presented. KW - ATLAS detector KW - energetic jet KW - proton-proton collision Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-150152 VL - 75 IS - 7 ER - TY - JOUR T1 - Measurement of the production and lepton charge asymmetry of bosons in Pb+Pb collisions at \(\sqrt {^{S}NN}\) with the ATLAS detector JF - European Physical Journal C: Particles and Fields N2 - A measurement of W boson production in lead-lead collisions at \(\sqrt {^{S}NN}\)=2.76 TeV is presented. It is based on the analysis of data collected with the ATLAS detector at the LHC in 2011 corresponding to an integrated luminosity of 0.14 nb\(^{-1}\) and 0.15 nb\(^{-1}\) in the muon and electron decay channels, respectively. The differential production yields and lepton charge asymmetry are each measured as a function of the average number of participating nucleons ⟨N\(_{part}\)⟩ and absolute pseudorapidity of the charged lepton. The results are compared to predictions based on next-to-leading-order QCD calculations. These measurements are, in principle, sensitive to possible nuclear modifications to the parton distribution functions and also provide information on scaling of W boson production in multi-nucleon systems. KW - Higgs boson KW - lead-lead collision Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-149889 VL - 75 IS - 1 ER -