TY - JOUR A1 - Dipaola, Mariangela A1 - Pavan, Esteban E. A1 - Cattaneo, Andrea A1 - Frazzitta, Giuseppe A1 - Pezzoli, Gianni A1 - Cavallari, Paolo A1 - Frigo, Carlo A. A1 - Isaias, Ioannis U. T1 - Mechanical Energy Recovery during Walking in Patients with Parkinson Disease JF - PLoS ONE N2 - The mechanisms of mechanical energy recovery during gait have been thoroughly investigated in healthy subjects, but never described in patients with Parkinson disease (PD). The aim of this study was to investigate whether such mechanisms are preserved in PD patients despite an altered pattern of locomotion. We consecutively enrolled 23 PD patients (mean age 64±9 years) with bilateral symptoms (H&Y ≥II) if able to walk unassisted in medication-off condition (overnight suspension of all dopaminergic drugs). Ten healthy subjects (mean age 62±3 years) walked both at their ‘preferred’ and ‘slow’ speeds, to match the whole range of PD velocities. Kinematic data were recorded by means of an optoelectronic motion analyzer. For each stride we computed spatio-temporal parameters, time-course and range of motion (ROM) of hip, knee and ankle joint angles. We also measured kinetic (Wk), potential (W\(_{p}\)), total (W\(_{totCM}\)) energy variations and the energy recovery index (ER). Along with PD progression, we found a significant correlation of W\(_{totCM}\) and W\(_{p}\) with knee ROM and in particular with knee extension in terminal stance phase. W\(_{k}\) and ER were instead mainly related to gait velocity. In PD subjects, the reduction of knee ROM significantly diminished both W\(_{p}\) and W\(_{totCM}\). Rehabilitation treatments should possibly integrate passive and active mobilization of knee to prevent a reduction of gait-related energetic components. KW - Parkinson disease KW - mechanical energy KW - kinematics KW - velocity KW - hip KW - gait analysis KW - walking KW - knees Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-179739 VL - 11 IS - 6 ER - TY - JOUR A1 - Boelch, Sebastian Philipp A1 - Weissenberger, Manuel A1 - Spohn, Frederik A1 - Rudert, Maximilian A1 - Luedemann, Martin T1 - Insufficient sensitivity of joint aspiration during the two-stage exchange of the hip with spacers JF - Journal of Orthopedic Surgery and Research N2 - Background: Evaluation of infection persistence during the two-stage exchange of the hip is challenging. Joint aspiration before reconstruction is supposed to rule out infection persistence. Sensitivity and specificity of synovial fluid culture and synovial leucocyte count for detecting infection persistence during the two-stage exchange of the hip were evaluated. Methods: Ninety-two aspirations before planned joint reconstruction during the two-stage exchange with spacers of the hip were retrospectively analyzed. Results: The sensitivity and specificity of synovial fluid culture was 4.6 and 94.3%. The sensitivity and specificity of synovial leucocyte count at a cut-off value of 2000 cells/μl was 25.0 and 96.9%. C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) values were significantly higher before prosthesis removal and reconstruction or spacer exchange (p = 0.00; p = 0.013 and p = 0.039; p = 0.002) in the infection persistence group. Receiver operating characteristic area under the curve values before prosthesis removal and reconstruction or spacer exchange for ESR were lower (0.516 and 0.635) than for CRP (0.720 and 0.671). Conclusions: Synovial fluid culture and leucocyte count cannot rule out infection persistence during the two-stage exchange of the hip. KW - two-stage exchange KW - hip KW - periprosthetic infection KW - joint aspiration KW - spacer Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-175576 VL - 13 IS - 7 ER - TY - JOUR A1 - Wimmer, Matthias D. A1 - Randau, Thomas M. A1 - Deml, Moritz C. A1 - Ascherl, Rudolf A1 - Forst, Raimund A1 - Gravius, Nadine A1 - Wirtz, Dieter A1 - Gravius, Sascha T1 - Impaction grafting in the femur in cementless modular revision total hip arthroplasty: a descriptive outcome analysis of 243 cases with the MRP-TITAN revision implant JF - BMC Musculoskeletal Disorders N2 - Background: We present a descriptive and retrospective analysis of revision total hip arthroplasties (THA) using the MRP-TITAN stem (Peter Brehm, Weisendorf, GER) with distal diaphyseal fixation and metaphyseal defect augmentation. Our hypothesis was that the metaphyseal defect augmentation (Impaction Bone Grafting) improves the stem survival. Methods: We retrospectively analyzed the aggregated and anonymized data of 243 femoral stem revisions. 68 patients with 70 implants (28.8%) received an allograft augmentation for metaphyseal defects; 165 patients with 173 implants (71.2%) did not, and served as controls. The mean follow-up was 4.4 +/- 1.8 years (range, 2.1-9.6 years). There were no significant differences (p > 0.05) between the study and control group regarding age, body mass index (BMI), femoral defects (types I-III as described by Paprosky), and preoperative Harris Hip Score (HHS). Postoperative clinical function was evaluated using the HHS. Postoperative radiologic examination evaluated implant stability, axial implant migration, signs of implant loosening, periprosthetic radiolucencies, as well as bone regeneration and resorption. Results: There were comparable rates of intraoperative and postoperative complications in the study and control groups (p > 0.05). Clinical function, expressed as the increase in the postoperative HHS over the preoperative score, showed significantly greater improvement in the group with Impaction Bone Grafting (35.6 +/- 14.3 vs. 30.8 +/- 15.8; p <= 0.05). The study group showed better outcome especially for larger defects (types II C and III as described by Paprosky) and stem diameters >= 17 mm. The two groups did not show significant differences in the rate of aseptic loosening (1.4% vs. 2.9%) and the rate of revisions (8.6% vs. 11%). The Kaplan-Meier survival for the MRP-TITAN stem in both groups together was 93.8% after 8.8 years. [Study group 95.7% after 8.54 years; control group 93.1% after 8.7 years]. Radiologic evaluation showed no significant change in axial implant migration (4.3% vs. 9.3%; p = 0.19) but a significant reduction in proximal stress shielding (5.7% vs. 17.9%; p < 0.05) in the study group. Periprosthetic radiolucencies were detected in 5.7% of the study group and in 9.8% of the control group (p = 0.30). Radiolucencies in the proximal zones 1 and 7 according to Gruen occurred significantly more often in the control group without allograft augmentation (p = 0.05). Conclusion: We present the largest analysis of the impaction grafting technique in combination with cementless distal diaphyseal stem fixation published so far. Our data provides initial evidence of improved bone regeneration after graft augmentation of metaphyseal bone defects. The data suggests that proximal metaphyseal graft augmentation is beneficial for large metaphyseal bone defects (Paprosky types IIC and III) and stem diameters of 17 mm and above. Due to the limitations of a retrospective and descriptive study the level of evidence remains low and prospective trials should be conducted. KW - prosthesis KW - replacement KW - collarless KW - surgery KW - allografts KW - porous-coated stems KW - femoral revision KW - roentgenographic assessment KW - tapered stem KW - follow-up KW - modular KW - revision KW - hip KW - arthroplasty KW - impaction bone grafting Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-122061 SN - 1471-2474 VL - 14 IS - 19 ER -