TY - JOUR A1 - Weißenberger, Manuel A1 - Wagenbrenner, Mike A1 - Schote, Fritz A1 - Horas, Konstantin A1 - Schäfer, Thomas A1 - Rudert, Maximilian A1 - Barthel, Thomas A1 - Heinz, Tizian A1 - Reppenhagen, Stephan T1 - The 3-triangle method preserves the posterior tibial slope during high tibial valgus osteotomy: first preliminary data using a mathematical model JF - Journal of Experimental Orthopaedics N2 - Purpose Despite much improved preoperative planning techniques accurate intraoperative assessment of the high tibial valgus osteotomy (HTO) remains challenging and often results in coronal over- and under-corrections as well as unintended changes of the posterior tibial slope. Noyes et al. reported a novel method for accurate intraoperative coronal and sagittal alignment correction based on a three-dimensional mathematical model. This is the first study examining preliminary data via the proposed Noyes approach for accurate intraoperative coronal and sagittal alignment correction during HTO. Methods From 2016 to 2020 a total of 24 patients (27 knees) underwent HTO applying the proposed Noyes method (Noyes-Group). Radiographic data was analyzed retrospectively and matched to patients that underwent HTO using the conventional method, i.e., gradual medial opening using a bone spreader under fluoroscopic control (Conventional-Group). All operative procedures were performed by an experienced surgeon at a single orthopaedic university center. Results From the preoperative to the postoperative visit no statistically significant changes of the posterior tibial slope were noted in the Noyes-Group compared to a significant increase in the Conventional-Group (p = 0.01). Regarding the axial alignment no significant differences between both groups were observed pre- and postoperatively. The number of over- and under-corrections did not differ significantly between both groups. Linear regression analysis showed a significant correlation of the postoperative medial proximal tibial angle (MPTA) with the position of the weightbearing line on the tibial plateau. Conclusion The 3-triangle method by Noyes seems to be a promising approach for preservation of the posterior tibial slope during HTO. KW - knee KW - high tibial valgus osteotomy KW - axial alignment KW - posterior tibial slope KW - weight bearing line KW - cartilage KW - triangle method KW - osteoarthritis Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-300806 SN - 2197-1153 VL - 9 ER - TY - JOUR A1 - Wagenbrenner, Mike A1 - Poker, Konrad A1 - Heinz, Tizian A1 - Herrmann, Marietta A1 - Horas, Konstantin A1 - Ebert, Regina A1 - Mayer-Wagner, Susanne A1 - Holzapfel, Boris M. A1 - Rudert, Maximilian A1 - Steinert, Andre F. A1 - Weißenberger, Manuel T1 - Mesenchymal stromal cells (MSCs) isolated from various tissues of the human arthritic knee joint possess similar multipotent differentiation potential JF - Applied Sciences N2 - (1) Background: The mesenchymal stromal cells (MSCs) of different tissue origins are applied in cell-based chondrogenic regeneration. However, there is a lack of comparability determining the most suitable cell source for the tissue engineering (TE) of cartilage. The purpose of this study was to compare the in vitro chondrogenic potential of MSC-like cells from different tissue sources (bone marrow, meniscus, anterior cruciate ligament, synovial membrane, and the infrapatellar fat pad removed during total knee arthroplasty (TKA)) and define which cell source is best suited for cartilage regeneration. (2) Methods: MSC-like cells were isolated from five donors and expanded using adherent monolayer cultures. Differentiation was induced by culture media containing specific growth factors. Transforming growth factor (TGF)-ß1 was used as the growth factor for chondrogenic differentiation. Osteogenesis and adipogenesis were induced in monolayer cultures for 27 days, while pellet cell cultures were used for chondrogenesis for 21 days. Control cultures were maintained under the same conditions. After, the differentiation period samples were analyzed, using histological and immunohistochemical staining, as well as molecularbiological analysis by RT-PCR, to assess the expression of specific marker genes. (3) Results: Plastic-adherent growth and in vitro trilineage differentiation capacity of all isolated cells were proven. Flow cytometry revealed the clear co-expression of surface markers CD44, CD73, CD90, and CD105 on all isolated cells. Adipogenesis was validated through the formation of lipid droplets, while osteogenesis was proven by the formation of calcium deposits within differentiated cell cultures. The formation of proteoglycans was observed during chondrogenesis in pellet cultures, with immunohistochemical staining revealing an increased relative gene expression of collagen type II. RT-PCR proved an elevated expression of specific marker genes after successful differentiation, with no significant differences regarding different cell source of native tissue. (4) Conclusions: Irrespective of the cell source of native tissue, all MSC-like cells showed multipotent differentiation potential in vitro. The multipotent differentiation capacity did not differ significantly, and chondrogenic differentiation was proven in all pellet cultures. Therefore, cell suitability for cell-based cartilage therapies and tissue engineering is given for various tissue origins that are routinely removed during total knee arthroplasty (TKA). This study might provide essential information for the clinical tool of cell harvesting, leading to more flexibility in cell availability. KW - knee joint KW - MSCs KW - cellular origin KW - cartilage regeneration KW - tissue engineering KW - cell-based therapies KW - osteoarthritis Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-262334 SN - 2076-3417 VL - 12 IS - 4 ER - TY - JOUR A1 - Wagenbrenner, Mike A1 - Heinz, Tizian A1 - Horas, Konstantin A1 - Jakuscheit, Axel A1 - Arnholdt, Jörg A1 - Hermann, Marietta A1 - Rudert, Maximilian A1 - Holzapfel, Boris M. A1 - Steinert, Andre F. A1 - Weißenberger, Manuel T1 - The human arthritic hip joint is a source of mesenchymal stromal cells (MSCs) with extensive multipotent differentiation potential JF - BMC Musculoskeletal Disorders N2 - Background While multiple in vitro studies examined mesenchymal stromal cells (MSCs) derived from bone marrow or hyaline cartilage, there is little to no data about the presence of MSCs in the joint capsule or the ligamentum capitis femoris (LCF) of the hip joint. Therefore, this in vitro study examined the presence and differentiation potential of MSCs isolated from the bone marrow, arthritic hyaline cartilage, the LCF and full-thickness samples of the anterior joint capsule of the hip joint. Methods MSCs were isolated and multiplied in adherent monolayer cell cultures. Osteogenesis and adipogenesis were induced in monolayer cell cultures for 21 days using a differentiation medium containing specific growth factors, while chondrogenesis in the presence of TGF-ss1 was performed using pellet-culture for 27 days. Control cultures were maintained for comparison over the same duration of time. The differentiation process was analyzed using histological and immunohistochemical stainings as well as semiquantitative RT-PCR for measuring the mean expression levels of tissue-specific genes. Results This in vitro research showed that the isolated cells from all four donor tissues grew plastic-adherent and showed similar adipogenic and osteogenic differentiation capacity as proven by the histological detection of lipid droplets or deposits of extracellular calcium and collagen type I. After 27 days of chondrogenesis proteoglycans accumulated in the differentiated MSC-pellets from all donor tissues. Immunohistochemical staining revealed vast amounts of collagen type II in all differentiated MSC-pellets, except for those from the LCF. Interestingly, all differentiated MSCs still showed a clear increase in mean expression of adipogenic, osteogenic and chondrogenic marker genes. In addition, the examination of an exemplary selected donor sample revealed that cells from all four donor tissues were clearly positive for the surface markers CD44, CD73, CD90 and CD105 by flow cytometric analysis. Conclusions This study proved the presence of MSC-like cells in all four examined donor tissues of the hip joint. No significant differences were observed during osteogenic or adipogenic differentiation depending on the source of MSCs used. Further research is necessary to fully determine the tripotent differentiation potential of cells isolated from the LCF and capsule tissue of the hip joint. KW - Hip joint KW - Osteoarthritis KW - MSCs KW - Cartilage regeneration KW - Tissue engineering KW - Ligamentum capitis femoris KW - Joint capsule KW - Bone marrow Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-229497 VL - 21 IS - 1 ER - TY - JOUR A1 - Wagenbrenner, Mike A1 - Heinz, Tizian A1 - Horas, Konstantin A1 - Jakuscheit, Axel A1 - Arnholdt, Joerg A1 - Mayer-Wagner, Susanne A1 - Rudert, Maximilian A1 - Holzapfel, Boris M. A1 - Weißenberger, Manuel T1 - Impact of Tranexamic Acid on Chondrocytes and Osteogenically Differentiated Human Mesenchymal Stromal Cells (hMSCs) In Vitro JF - Journal of Clinical Medicine N2 - The topical application of tranexamic acid (TXA) helps to prevent post-operative blood loss in total joint replacements. Despite these findings, the effects on articular and periarticular tissues remain unclear. Therefore, this in vitro study examined the effects of varying exposure times and concentrations of TXA on proliferation rates, gene expression and differentiation capacity of chondrocytes and human mesenchymal stromal cells (hMSCs), which underwent osteogenic differentiation. Chondrocytes and hMSCs were isolated and multiplied in monolayer cell cultures. Osteogenic differentiation of hMSCs was induced for 21 days using a differentiation medium containing specific growth factors. Cell proliferation was analyzed using ATP assays. Effects of TXA on cell morphology were examined via light microscopy and histological staining, while expression levels of tissue-specific genes were measured using semiquantitative RT-PCR. After treatment with 50 mg/mL of TXA, a decrease in cell proliferation rates was observed. Furthermore, treatment with concentrations of 20 mg/mL of TXA for at least 48 h led to a visible detachment of chondrocytes. TXA treatment with 50 mg/mL for at least 24 h led to a decrease in the expression of specific marker genes in chondrocytes and osteogenically differentiated hMSCs. No significant effects were observed for concentrations beyond 20 mg/mL of TXA combined with exposure times of less than 24 h. This might therefore represent a safe limit for topical application in vivo. Further research regarding in vivo conditions and effects on hMSC functionality are necessary to fully determine the effects of TXA on articular and periarticular tissues. KW - tranexamic acid KW - hMSCs KW - chondrocytes KW - osteoarthritis KW - toxicity KW - differentiation capacity Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-219410 SN - 2077-0383 VL - 9 IS - 12 ER - TY - JOUR A1 - Seiler, Jonas A1 - Ebert, Regina A1 - Rudert, Maximilian A1 - Herrmann, Marietta A1 - Leich, Ellen A1 - Weißenberger, Manuela A1 - Horas, Konstantin T1 - Bone metastases of diverse primary origin frequently express the VDR (vitamin D receptor) and CYP24A1 JF - Journal of Clinical Medicine N2 - Active vitamin D (1,25(OH)2D3) is known to exert direct anti-cancer actions on various malignant tissues through binding to the vitamin D receptor (VDR). These effects have been demonstrated in breast, prostate, renal and thyroid cancers, which all have a high propensity to metastasise to bone. In addition, there is evidence that vitamin D catabolism via 24-hydroxylase (CYP24A1) is altered in tumour cells, thus, reducing local active vitamin D levels in cancer cells. The aim of this study was to assess VDR and CYP24A1 expression in various types of bone metastases by using immunohistochemistry. Overall, a high total VDR protein expression was detected in 59% of cases (39/66). There was a non-significant trend of high-grade tumours towards the low nuclear VDR expression (p = 0.07). Notably, patients with further distant metastases had a reduced nuclear VDR expression (p = 0.03). Furthermore, a high CYP24A1 expression was detected in 59% (39/66) of bone metastases. There was a significant positive correlation between nuclear VDR and CYP24A1 expression (p = 0.001). Collectively, the VDR and CYP24A1 were widely expressed in a multitude of bone metastases, pointing to a potential role of vitamin D signalling in cancer progression. This is of high clinical relevance, as vitamin D deficiency is frequent in patients with bone metastases. KW - vitamin D receptor KW - VDR KW - CYP24A1 KW - bone metastasis KW - vitamin D Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-297377 SN - 2077-0383 VL - 11 IS - 21 ER - TY - JOUR A1 - Rudert, Maximilian A1 - Horas, Konstantin A1 - Hoberg, Maik A1 - Steinert, Andre A1 - Holzapfel, Dominik Emanuel A1 - Hübner, Stefan A1 - Holzapfel, Boris Michael T1 - The Wuerzburg procedure: the tensor fasciae latae perforator is a reliable anatomical landmark to clearly identify the Hueter interval when using the minimally-invasive direct anterior approach to the hip joint JF - BMC Musculoskeletal Disorders N2 - Background The key for successful delivery in minimally-invasive hip replacement lies in the exact knowledge about the surgical anatomy. The minimally-invasive direct anterior approach to the hip joint makes it necessary to clearly identify the tensor fasciae latae muscle in order to enter the Hueter interval without damaging the lateral femoral cutaneous nerve. However, due to the inherently restricted overview in minimally-invasive surgery, this can be difficult even for experienced surgeons. Methods and Surgical Technique In this technical note, we demonstrate for the first time how to use the tensor fasciae latae perforator as anatomical landmark to reliably identify the tensor fasciae latae muscle in orthopaedic surgery. Such perforators are used for flaps in plastic surgery as they are constant and can be found at the lateral third of the tensor fasciae latae muscle in a direct line from the anterior superior iliac spine. Conclusion As demonstrated in this article, a simple knowledge transfer between surgical disciplines can minimize the complication rate associated with minimally-invasive hip replacement. KW - anatomical landmark KW - direct anterior approach KW - Hueter interval KW - minimally-invasive KW - hip replacement KW - perforator Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-146031 VL - 17 IS - 57 ER - TY - JOUR A1 - Prodinger, Peter Michael A1 - Lazic, Igor A1 - Horas, Konstantin A1 - Burgkart, Rainer A1 - von Eisenhart-Rothe, Rüdiger A1 - Weissenberger, Manuel A1 - Rudert, Maximilian A1 - Holzapfel, Boris Michael T1 - Revision Arthroplasty Through the Direct Anterior Approach Using an Asymmetric Acetabular Component JF - Journal of Clinical Medicine N2 - Despite increasing numbers of primary hip arthroplasties performed through the direct anterior approach (DAA), there is a lack of literature on DAA revision arthroplasty. The present study was performed in order to evaluate outcomes and revision rates after revision through the DAA using an asymmetric acetabular component with optional intra- and extramedullary fixation. In a retrospective cohort study, we analyzed prospectively collected data of 57 patients (61 hips, 43 female, 18 male) who underwent aseptic acetabular component revision through the DAA with the abovementioned implant system between January 2015 and December 2017. The mean follow-up was 40 months (12–56). Survival rates were estimated using the Kaplan–Meier method. All complications were documented and functional outcomes were assessed pre- and postoperatively. Kaplan–Meier analysis revealed an estimated five-year implant survival of 97% (confidence interval CI 87–99%). The estimated five-year survival with revision for any cause was 93% (CI 83–98%). The overall revision rate was 6.6% (n = 4). Two patients had to undergo revision due to periprosthetic infection (3.3%). In one patient, the acetabular component was revised due to aseptic loosening four months postoperatively. Another patient suffered from postoperative iliopsoas impingement and was treated successfully by arthroscopic iliopsoas tenotomy. Two (3.3%) of the revised hips dislocated postoperatively. The mean Harris Hip Score improved from 35 (2–66) preoperatively to 86 (38–100) postoperatively (p < 0.001). The hip joint’s anatomical center of rotation was restored at a high degree of accuracy. Our findings demonstrate that acetabular revision arthroplasty through the DAA using an asymmetric acetabular component with optional intra- and extramedullary fixation is safe and practicable, resulting in good radiographic and clinical midterm results. KW - anterior approach KW - revision arthroplasty KW - hip joint KW - acetabular bone defect KW - asymmetric implant KW - anatomic center of rotation Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-213184 SN - 2077-0383 VL - 9 IS - 9 ER - TY - JOUR A1 - Horas, Konstantin A1 - van Herck, Ulrike A1 - Maier, Gerrit S. A1 - Maus, Uwe A1 - Harrasser, Norbert A1 - Jakob, Franz A1 - Weissenberger, Manuel A1 - Arnholdt, Jörg A1 - Holzapfel, Boris M. A1 - Rudert, Maximilian T1 - Does vitamin D deficiency predict tumour malignancy in patients with bone tumours? Data from a multi-center cohort analysis JF - Journal of Bone Oncology N2 - Vitamin D deficiency is a global health concern that is estimated to afflict over one billion people globally. The major role of vitamin D is that of a regulator of calcium and phosphate metabolism, thus, being essential for proper bone mineralisation. Concomitantly, vitamin D is known to exert numerous extra-skeletal actions. For example, it has become evident that vitamin D has direct anti-proliferative, pro-differentiation and pro-apoptotic actions on cancer cells. Hence, vitamin D deficiency has been associated with increased cancer risk and worse prognosis in several malignancies. We have recently demonstrated that vitamin D deficiency promotes secondary cancer growth in bone. These findings were partly attributable to an increase in bone remodelling but also through direct effects of vitamin D on cancer cells. To date, very little is known about vitamin D status of patients with bone tumours in general. Thus, the objective of this study was to assess vitamin D status of patients with diverse bone tumours. Moreover, the aim was to elucidate whether or not there is an association between pre-diagnostic vitamin D status and tumour malignancy in patients with bone tumours. In a multi-center analysis, 25(OH)D, PTH and calcium levels of 225 patients that presented with various bone tumours between 2017 and 2018 were assessed. Collectively, 76% of all patients had insufficient vitamin D levels with a total mean 25(OH)D level of 21.43 ng/ml (53.58 nmol/L). In particular, 52% (117/225) of patients were identified as vitamin D deficient and further 24% of patients (55/225) were vitamin D insufficient. Notably, patients diagnosed with malignant bone tumours had significantly lower 25(OH)D levels than patients diagnosed with benign bone tumours [19.3 vs. 22.75 ng/ml (48.25 vs. 56.86 nmol/L); p = 0.04). In conclusion, we found a widespread and distressing rate of vitamin D deficiency and insufficiency in patients with bone tumours. However, especially for patients with bone tumours sufficient vitamin D levels seem to be of great importance. Thus, we believe that 25(OH)D status should routinely be monitored in these patients. Collectively, there should be an increased awareness for physicians to assess and if necessary correct vitamin D status of patients with bone tumours in general or of those at great risk of developing bone tumours. KW - bone tumour KW - vitamin D KW - hypovitaminosis D KW - vitamin D deficiency KW - malignancy KW - tumour malignancy Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-230314 VL - 25 ER - TY - JOUR A1 - Heinz, Tizian A1 - Meller, Felix A1 - Luetkens, Karsten Sebastian A1 - Horas, Konstantin A1 - Schäfer, Thomas A1 - Rudert, Maximilian A1 - Reppenhagen, Stephan A1 - Weißenberger, Manuel T1 - Can the MRI based AMADEUS score accurately assess pre-surgery chondral defect severity according to the ICRS arthroscopic classification system? JF - Journal of Experimental Orthopaedics N2 - Purpose The AMADEUS (Area Measurement And DEpth and Underlying Structures) scoring and grading system has been proposed for the MRI based evaluation of untreated focal chondral defects around the knee. The clinical practicability, its correlation with arthroscopically assessed grading systems (ICRS – International Cartilage Repair Society) and thereby its clinical value in terms of decision making and guiding prognosis was yet to determine. Methods From 2008 to 2019 a total of 89 individuals were indicated for high tibial valgus osteotomy (HTO) due to tibial varus deformity and concomitant chondral defects of the medial compartment of the knee. All patients received a preoperative MRI (1.5 Tesla or 3.0 Tesla) and pre-osteotomy diagnostic arthroscopy. Chondral defects of the medial compartment were scored and graded with the MRI based AMADEUS by three independent raters and compared to arthroscopic defect grading by the ICRS system. Interrater and intrarater reliability as well as correlation analysis with the ICRS classification system were assessed. Results Intraclass correlation coefficients for the various subscores of the AMADEUS showed an overall good to excellent interrater agreement (min: 0.26, max: 0.80). Intrarater agreement turned out to be substantially inferior (min: 0.08, max: 0.53). Spearman correlation revealed an overall moderate correlative association of the AMADEUS subscores with the ICRS classification system, apart from the defect area subscore. Sensitivity of the AMADEUS to accurately identify defect severity according to the ICRS was 0.7 (0.69 for 3.0 Tesla MRI, 0.67 for 1.5 Tesla MRI). The mean AMADEUS grade was 2.60 ± 0.81 and the mean ICRS score 2.90 ± 0.63. Conclusions Overall, the AMADEUS with all its subscores shows moderate correlation with the arthroscopic chondral grading system according to ICRS. This suggests that chondral defect grading by means of the MRI based AMADEUS is well capable of influencing and guiding treatment decisions. Interrater reliability shows overall good agreement. KW - MRI KW - knee KW - cartilage defect KW - grading system of chondral defects KW - AMADEUS KW - ICRS Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-300781 SN - 2197-1153 VL - 9 IS - 1 ER - TY - JOUR A1 - Arnholdt, Jörg A1 - Kamawal, Yama A1 - Horas, Konstantin A1 - Holzapfel, Boris M. A1 - Gilbert, Fabian A1 - Ripp, Axel A1 - Rudert, Maximilian A1 - Steinert, Andre F. T1 - Accurate implant fit and leg alignment after cruciate-retaining patient-specific total knee arthroplasty JF - BMC Musculoskeletal Disorders N2 - Background For improved outcomes in total knee arthroplasty (TKA) correct implant fitting and positioning are crucial. In order to facilitate a best possible implant fitting and positioning patient-specific systems have been developed. However, whether or not these systems allow for better implant fitting and positioning has yet to be elucidated. For this reason, the aim was to analyse the novel patient-specific cruciate retaining knee replacement system iTotal (TM) CR G2 that utilizes custom-made implants and instruments for its ability to facilitate accurate implant fitting and positioning including correction of the hip-knee-ankle angle (HKA). Methods We assessed radiographic results of 106 patients who were treated with the second generation of a patient-specific cruciate retaining knee arthroplasty using iTotal\(^{TM}\) CR G2 (ConforMIS Inc.) for tricompartmental knee osteoarthritis (OA) using custom-made implants and instruments. The implant fit and positioning as well as the correction of the mechanical axis (hip-knee-ankle angle, HKA) and restoration of the joint line were determined using pre- and postoperative radiographic analyses. Results On average, HKA was corrected from 174.4 degrees +/- 4.6 degrees preoperatively to 178.8 degrees +/- 2.2 degrees postoperatively and the coronal femoro-tibial angle was adjusted on average 4.4 degrees. The measured preoperative tibial slope was 5.3 degrees +/- 2.2 degrees (mean +/- SD) and the average postoperative tibial slope was 4.7 degrees +/- 1.1 degrees on lateral views. The joint line was well preserved with an average modified Insall-Salvati index of 1.66 +/- 0.16 pre- and 1.67 +/- 0.16 postoperatively. The overall accuracy of fit of implant components was decent with a measured medial overhang of more than 1 mm (1.33 mm +/- 0.32 mm) in 4 cases only. Further, a lateral overhang of more than 1 mm (1.8 mm +/- 0.63) (measured in the anterior-posterior radiographs) was observed in 11 cases, with none of the 106 patients showing femoral notching. Conclusion The patient-specific iTotal\(^{TM}\) CR G2 total knee replacement system facilitated a proper fitting and positioning of the implant components. Moreover, a good restoration of the leg axis towards neutral alignment was achieved as planned. Nonetheless, further clinical follow-up studies are necessary to validate our findings and to determine the long-term impact of using this patient- specific system. KW - total knee replacement KW - knee axis KW - patient-specific knee arthroplasty KW - knee osteoarthritis KW - implant positioning Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-230012 VL - 21 ER -