TY - THES A1 - Groß, Heiko T1 - Controlling Light-Matter Interaction between Localized Surface Plasmons and Quantum Emitters T1 - Kontrollierte Licht-Materie Wechselwirkung zwischen lokalisierten Oberflächenplasmonen und Quantenemittern N2 - Metal nanostructures have been known for a long time to exhibit optical resonances via localized surface plasmons. The high electric fields in close proximity to the metal surface have prospects to dramatically change the dynamics of electronic transitions, such as an enhanced spontaneous decay rate of a single emitter. However, there have been two major issues which impede advances in the experimental realization of enhanced light-matter interaction. (i) The fabrication of high-quality resonant structures requires state-of-the-art patterning techniques in combination with superior materials. (ii) The tiny extension of the optical near-field requires precise control of the single emitter with respect to the nanostructure. This work demonstrates a solution to these problems by combining scanning probe and optical confocal microscopy. Here, a novel type of scanning probe is introduced which features a tip composed of the edge of a single crystalline gold sheet. The patterning via focused ion beam milling makes it possible to introduce a plasmonic nanoresonator directly at the apex of the tip. Numerical simulations demonstrate that the optical properties of this kind of scanning probe are ideal to analyze light-matter interaction. Detailed experimental studies investigate the coupling mechanism between a localized plasmon and single colloidal quantum dots by dynamically changing coupling strength via their spatial separation. The results have shown that weak interaction affects the shape of the fluorescence spectrum as well as the polarization. For the best probes it has been found that it is possible to reach the strong coupling regime at the single emitter level at room temperature. The resulting analysis of the experimental data and the proposed theoretical models has revealed the differences between the established far-field coupling and near-field coupling. It has been found that the broad bandwidth of plasmonic resonances are able to establish coherent coupling to multiple transitions simultaneously giving rise to an enhanced effective coupling strength. It has also been found that the current model to numerically calculate the effective mode volume is inaccurate in case of mesoscopic emitters and strong coupling. Finally, light-matter interaction is investigated by the means of a quantum-dot-decorated microtubule which is traversing a localized nearfield by gliding on kinesin proteins. This biological transport mechanism allows the parallel probing of a meta-surface with nm-precision. The results that have been put forward throughout this work have shed new light on the understanding of plasmonic light-matter interaction and might trigger ideas on how to more efficiently combine the power of localized electric fields and novel excitonic materials. N2 - Metallische Nanostrukturen sind seit langer Zeit bekannt dafür optische Resonanzen durch lokalisierte Oberflächenplasmonen zu zeigen. Hohe elektrische Felder in direkter Nähe zur Metalloberfläche versprechen dramatische Dynamikänderungen von elektrischen Übergängen wie z.B. die gesteigerte spontane Zerfallsrate eines Einzelemitters. Es gibt jedoch zwei maßgebliche Gründe warum die Fortschritte der experimentellen Realisierung von Licht-Materie Wechselwirkung ausgebremst wird. (i) Die Herstellung von qualitativ hochwertigen resonanten Strukturen benötigt modernste Strukturierungsmethoden sowie die bestmöglichen Materialeigenschaften. (ii) Die winzigen Dimensionen von optischen Nahfeldern erfordern eine präzise Kontrolle des Einzelemitters im Bezug zur Nanostruktur. Diese Arbeit löst diese Probleme durch die Kombination eines Rasterkraftmikroskops mit einem optischen Konfokalmikroskop. Dabei wird eine neuartige Rastersonde vorgestellt welche eine Spitze aufweist die aus der Ecke einer monokristallinen Goldflocke besteht. Die Strukturierung mittels eines fokussierten Ionenstrahls ermöglicht es einen plasmonischen Nanoresonator direkt an der Spitze der Sonde herzustellen. Numerische Simulationen haben gezeigt, dass die optischen Eigenschaften für diese Art von Sonde ideal sind um Licht-Materie Wechselwirkung zu untersuchen. Die hier gezeigten experimentellen Studien haben den Kopplungsmechanismus zwischen lokalisierten Plasmonen und einzelnen kolloidalen Quantenpunkten untersucht indem die Kopplungstärke dynamisch über den Abstand kontrolliert wurde. Die Ergebnisse haben gezeigt, dass schwache Wechselwirkung einen Einfluss auf die Form des Fluoreszenzspektrums als auch auf die Polarisation hat. Die besten Sonden haben gezeigt, dass es möglich ist starke Wechselwirkung mit Einzelemittern bei Raumtemperatur zu erreichen. Die resultierende Analyse der experimentellen Daten und die aufgestellten theoretischen Modelle haben die Unterschiede zwischen der etablierten Fernfeldkopplung und der Nahfeldkopplung aufgezeigt. Dabei wurde beobachtet, dass die große Bandbreite von plasmonischen Resonanzen es möglich macht kohärent mit mehreren Übergängen gleichzeitig zu koppeln und dabei die effektive Kopplungsstärke zu höhen. Es wurde auch festgestellt, dass das aktuelle Model zur numerischen Beschreibung von effektiven Modenvolumen Ungenauigkeiten bei mesoskopischen Emittern und starker Wechselwirkung aufzeigt. Zuletzt wird die Licht-Materie Wechselwirkung mittels Quantenpunkt-bestückten Mikrotubuli untersucht, die auf Kinesin Proteinen durch ein lokalisiertes Nahfeld gleiten. Dieses biologische Transportsystem erlaubt es eine Meta-Oberfläche mit nm-Präzision parallel zu untersuchen. Die Ergebnisse, die diese Arbeit hervorgebracht hat, wirft neues Licht auf das Verständnis von plasmonischer Licht-Materie Wechselwirkung und könnte als Grundlage dienen neue Ideen zu entwickeln um effizienter die Stärke von lokalisierten elektrischen Felder und neuartiger exzitonischer Materialien zu kombinieren. KW - Plasmon KW - Starke Kopplung KW - Quantenpunkt KW - Mikrotubulus KW - Nahfeldoptik KW - light-matter interaction KW - quantum optics KW - optical antenna KW - quantum dot KW - surface plasmon KW - strong coupling Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-192097 ER - TY - THES A1 - Gerhard, Felicitas Irene Veronika T1 - Controlling structural and magnetic properties of epitaxial NiMnSb for application in spin torque devices T1 - Anpassung der strukturellen und magnetischen Eigenschaften von epitaktischem NiMnSb in Hinsicht auf die Anwendung in Spin Drehmoment Bauteilen N2 - This thesis describes the epitaxial growth of the Half-Heusler alloy NiMnSb by molecular beam epitaxy. Its structural and magnetic properties are controlled by tuning the composition and the resulting small deviation from stoichiometry. The magnetic in-plane anisotropy depends on the Mn concentration of the sample and can be controlled in both strength and orientation. This control of the magnetic anisotropy allows for growing NiMnSb layers of a given thickness and magnetic properties as requested for the design of NiMnSb-based devices. The growth and characterization of NiMnSb-ZnTe-NiMnSb heterostructures is presented - such heterostructures form an all-NiMnSb based spin-valve and are a promising basis for spin torque devices. N2 - Diese Arbeit beschreibt das epitaktische Wachstum der Halb-Heusler Legierung NiMnSb mittels Molekularstrahl Epitaxie. Durch Abstimmen der Zusammensetzung und einer daraus folgenden geringen Abweichung der Stöchiometrie werden die strukturellen und magnetischen Eigenschaften gesteuert. Die magnetische Anisotropie hängt von der Mn Konzentration der Probe ab, wobei sowohl die Stärke als auch die Orientierung der Anisotropie angepasst werden kann. Die Kontrolle der magnetischen Anisotropie erlaubt das Wachstum von NiMnSb Schichten mit gegebener Dicke und magnetischen Eigenschaften, die für das Design von NiMnSb-basierten Bauteilen erforderlich sind. Das Wachstum und die Charakterisierung von NiMnSb-ZnTe-NiMnSb Heterostrukturen wird präsentiert - solche Heterostrukturen bilden ein rein NiMnSb-basiertes Spinventil und sind eine vielversprechende Basis für Spin Drehmoment Bauteile. KW - Nickelverbindungen KW - Manganverbindungen KW - Half Heusler alloy NiMnSb KW - molecular beam epitaxy KW - magnetic anisotropy KW - spin valve KW - spin torque device KW - Halb-Heusler Legierung NiMnSb KW - Molekularstrahl Epitaxie KW - Magnetische Anisotropie KW - Spinventil KW - Spindrehmoment Bauteil KW - Antimonverbindungen KW - Heterostruktur KW - Molekularstrahlepitaxie KW - Heuslersche Legierung Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-111690 ER - TY - THES A1 - Issing, Sven T1 - Correlation between Lattice Dynamics and Magnetism in the Multiferroic Manganites T1 - Korrelation von Kristallgitterdynamik und Magnetismus in den Multiferroischen Manganaten N2 - In this thesis a systematic analysis of the correlation effects between lattice dynamics and magnetism in the Multiferroic Manganites RMnO3 with Pnma structure was conducted. For this task, Raman and FT-IR Spectroscopy were employed for an investigation of all optically accessible lattice vibrations, i.e. phonons. To study the correlation effects as well as their specific connections to symmetry and compositional properties of the Multiferroic Manganites, the polarisation and temperature dependence of the phonons were considered explicitly. In combination with lattice dynamical calculations based on Density Functional Theory, two coupling effects - Spin-Phonon Coupling and Electromagnon-Phonon Coupling - were systematically analysed. N2 - Grundlegendes Verständnis der physikalischen Zusammenhänge innerhalb multifunktionaler Materialien im Hinblick auf spätere potentielle Anwendungen ist eines der Hauptziele der heutigen Forschungsbemühungen in der Festkörperphysik. Im Wesentlichen geht es dabei um das Ausnutzen von intrinsischen Kopplungseffekten, um zusätzliche Funktionalität im Vergleich zur heutigen auf Miniaturisierung von halbleiterbasierten Bauelementen aufbauenden Informationstechnologie zu erreichen. Die vorgelegte Dissertation zielt in dies em Themengebiet auf die systematische Untersuchung der Kopplungseffekte zwischen Kristallgitterdynamik und Magnetismus in den multiferroischen Manganaten ab. Konkret geht es um das Modelsystem der multiferroischen Selten-Erd-Manganate RMnO3 mit orthorhombischer Pnma-Struktur. Die zu diesem Zweck verwendeten experimentellen Techniken waren Raman und Fourier-Transform Infrarot (FT-IR) Spektroskopie, mit deren Hilfe alle optisch aktiven Kristallgitterschwingungen dieser Systeme spektroskopiert werden konnten. Zur Untersuchung der Kopplungseffekte wurden die spektroskopischen Experimente polarisationssensitiv und unter Variation der Probentemperatur durchgeführt, um insbesondere Renormalisierungseffekte der Gitterschwingungen im Temperaturbereich magnetischer Phasenübergänge nachweisen zu können. In Verbindung mit gitterdynamischen Rechnungen, die auf der Dichtefunktionaltheorie (DFT) basieren, wurden zwei Kopplungseffekte systematisch untersucht: Spin-Phonon Kopplung (SPC) sowie Elektromagnon-Phonon Kopplung (EMPC). KW - FT-IR-Spektroskopie KW - Multiferroikum KW - Magnetoelektrischer Effekt KW - Manganate KW - Magneto-Elektrischer Effekt KW - Raman-Spektroskopie KW - Manganate KW - Dichtefunktionalformalismus KW - Magneto-Electric Effect KW - Multiferroics Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-66283 ER - TY - THES A1 - Martin, Konstantin T1 - Current-induced Magnetization Switching by a generated Spin-Orbit Torque in the 3D Topological Insulator Material HgTe T1 - Strom-Induzierte Umorientierung einer Magnetisierung mit Hilfe eines Spin-Bahn Drehmoments auf der Oberfläche des 3D topologischen Isolators HgTe N2 - Magnetic random access memory (MRAM) technology aims to replace dynamic RAM (DRAM) due to its significantly lower power consumption and non-volatility [Dong08]. During the last couple of years the commercial focus was set on spin-transfer torque MRAM (STT-MRAM) systems, where a current is pushed through a ferromagnetic (FM) free layer and a reference layer which are separated by an insulator. The free layer can be set to parallel or anti-parallel depending on the current direction [Kim11]. Unfortunately these currents have to be quite high which could lead to damages of the tunnel barrier of the magnetic tunnel junction resulting in higher power consumption as well as reliability issues. At this point a new effect, where the current is passed below the ferromagnetic layer stack, can be exploited to change the direction of the free layer magnetization. The effect is known as spin-orbit torque (SOT) and describes the transfer of angular momentum onto an adjacent magnetization either by the spin Hall effect (SHE) or inverse spin galvanic effect (iSGE) [Manchon19]. The latter describes a spin accumulation due to a current. This is similar to the process of spin accumulation in TIs, where a current corresponds to an effective spin due to spin-momentum locking [Qi11]. Thus TIs exhibit a high current-to-spin conversion rate, which makes them a promising material system for SOT experiments. Among all TIs it is HgTe, which can be reliably grown as an insulator. This thesis covers the development of a working device for SOT measurements (SOT-device) in a CdTe/CdHgTe/HgTe/CdHgTe heterostructure. It involves the development of a tunnel barrier (ZrOx) as well as the investigation of the behavior of a ferromagnetic layer stack on top of etched HgTe. The main result of this work is the successful construction and evaluation of a working SOT-device, which exhibits the up to date most efficient switching of in-plane magnetized ferromagnetic layer stacks. In order to avoid hybridization between HgTe and the adjacent ferromagnetic atoms, which would cause a breakdown of the topological surface state, it is necessary to implement a thin tunnel barrier in between the TI and free layer [Zhang16]. Aside from hybridization a tunnel barrier avoids shunting of the current, that is pushed on the surface of the HgTe/CdHgTe interface. Thus a bigger part of the current can be used for spin accumulation and, at the same time, the resistance measurement of the ferromagnetic layer stack is not perturbed. In chapter 3 the focus is set on investigating the tunneling characteristics of ZrOx on top of dry etched HgTe. Thin barriers are used as the interaction of the current generated spin and the adjacent magnetization decreases with distance. On the other hand too small insulator thicknesses lead to leakage currents which disturb heavily the measurement of the resistance of the ferromagnetic layer stack. Thus an optimum thickness of 10 ALD cycles (\(d\approx 1.6\rm\, nm\)) is determined which yields a resistance area product of \(R\cdot A \approx 3\rm\, k\Omega\mu m^{2}\). This corresponds to a tunneling resistance of \(R_{T}\approx 20\rm\, k\Omega\) over a structure surface of \(A_{T} = 0.12\rm\, \mu m^2\). Multiple samples with different thicknesses have been produced. All samples have been examined on their tunneling behavior. The resistance area product as a function of thickness shows a linear behavior on a logarithmic scale. Furthermore all working samples show non-linear I-V curves as well as parabolic dI/dV-curves. Additionally the tunneling resistance \(R_{T}\) increases with decreasing temperature. All above mentioned properties are typical for tunnel barriers which do not include pinholes [Jonsson00]. The last part of chapter 3 deals with thermal properties of HgTe. By measuring the second harmonic of a biasing AC current in the channel below the tunnel barrier it is attempted to extract the diffusion thermopower of the heated electrons. Unfortunately the measured signal showed a far superior contribution of the first harmonic. According to electric circuit simulations a small asymmetry in the barrier (penetration and leaving point of electrons) could be responsible for this behavior. A ferromagnetic layer stack, consisting of PY/Cu/CoFe, serves as a sensor for magnetization changes due to external fields and current induced spin accumulations. The layer stack exhibits a giant magnetoresistance (GMR) which has been measured by a resistance bridge. The biggest peculiarity in depositing a GMR stack on top of HgTe is that its easy axis forms along only one of the crystal axes (\((110)\) or \((1\overline{1}0)\)). The reason for this anisotropy is still unclear. Sources such as an influence of the terminating material, miscut, furrows during IBE or sputter ripples have been ruled out. It can be speculated that the surface states due to HgTe might have an influence on the development of this easy axis but this would need further investigation. A consequence of this unexpected anisotropy is that every CdTe/CdHgTe/HgTe/CdHgTe wafer has first to be characterized in SQUID in order to find the easy axis. A ferromagnetic resonance (FMR) measurement confirmed this observation. The shape of the ferromagnetic layer stack is chosen to be an ellipse in order to support the easy axis direction by shape anisotropy. Over 8 million ellipses are used to generate a SQUID signal of \(m > 10^{-5}\rm\, emu\). This is sufficient to extract the main characteristics of an average nano pillar under the influence of an external magnetic field. As in the case of bigger structures the ellipse shaped structure shows a step-like behavior. A measured minor loop confirms the existence of the irreversible anti-parallel stable magnetic state. Furthermore this state persists for both directions at \(m=0\) resulting in an anti-ferromagnetic coupling between Py and CoFe. The geometry of the SOT-device is chosen in such a way that the current induced spin aligns either parallel or anti-parallel to the effective magnetic field \(\vec{B}_{eff}=\vec{B}_{ext}+\vec{B}_{aniso}+\vec{B}_{shape}\), which acts on the pillar. Due to interaction of the spin with the adjacent magnetization of Py the magnetization direction gets changed by a torque \(\vec{T}\). In general this torque can be decomposed into two components a field-like torque \(\vec{\tau}_{FL}\) and a damping-like torque \(\vec{\tau}_{DL}\) [Manchon19]. In the case of TIs \(\vec{T}\) is additionally depending on the z-component of \(\vec{m}\) [Ndiaye17]. In our case the magnetization is lying in the sample plane (\(m_{z}=0\)) which results in \(\vec{\tau}_{DL}=0\). Thus, in the case of \(\vec{S}\parallel\left(\vec{\hat{z}}\times\vec{j}\right)\) and \(\vec{j}\parallel\vec{\hat{y}}\), the only spin dependent effective magnetic field is \(\vec{B}_{FL}=\tau_{FL}\cdot\vec{\hat{x}}\) which is lying parallel or anti-parallel to \(\vec{B}_{eff}\). The evaluation of \(\vec{B}_{FL}\) can therefore be done in the following manner. First a high \(B_{ext}\) has to be set along the easy axis of the pillar. Then \(B_{ext}\) has to be reduced just a few \(\rm\, Oe\) before the switching occurs at the magnetic field \(B_{ext,0}\). At the magnetic field \(\Delta B = B_{ext}-B_{ext,0}\approx 0.5\rm\, Oe\) the lower resistive state should be stable over a longer time range (\(10-30\rm\, min\)) in order to exclude switching due to fluctuations. Now a positive or negative current can be pushed through the channel below the pillar. For one of the two current directions the magnetization of Py switches. It is therefore not a thermal effect that drives the change of \(\vec{m}\). Current densities that are able to switch \(\vec{m}\) at small \(\Delta B\neq 0\) lie in the range of \(j\approx 10^{4}\rm\, A/cm^{2}\). In all experiments the switching efficiency \(\Delta B/j\) decreases with rising \(j\). Furthermore the efficiency as a function of \(j\) depends on the temperature as \(\Delta B/j\) values tend to be up to 20 times higher at \(T=1.8\rm\, K\) and \(j\approx 0\) than at \(T=4.2\rm\, K\). This temperature dependence suggests that switching occurs not due to Oersted fields. Furthermore the Biot-Savart fields had been calculated for four different models: an infinite long rectangular wire, two infinite planes, a full volume and two thin volume planes. Every model shows an efficiency, which is at least three times lower than the observation. The highest efficiencies in our samples show up to 10 times higher values than in heavy-metal/ferromagnets heterostructures. In contrast to measurement procedures of most other groups our method leads to direct determination of SOT parameters like the effective magnetic field \(\vec{B}_{FL}\). Other groups make use of spin-transfer FMR (ST-FMR) where they AC bias their structure and extract SOT parameters (like \(\tau_{FL}\) and \(\tau_{DL}\)) from second harmonics by fitting theoretical models. Material systems consisting of TIs and magnetic insulators (MIs) on the other hand show 10 times higher efficiencies [Khang18,Li19]. In those cases the magnetization points out of the sample plane which is conceptually different from in-plane magnetic anisotropy geometries like in our case. The greatest benefit in-plane magnetic anisotropy systems is its easy realisation [Bhatti17]. Here only an elliptical shape has to be lithographically implemented instead of conducting research on the appropriate combination of material systems that result in perpendicular magnetic anisotropies [Apalkov16]. Despite the fact that in our case only \(\vec{\tau}_{FL}\) acts as the driving force for changing \(m\) our device still exhibits the up to date highest efficiencies in the class of in-plane magnetized anisotropies of all material classes ever recorded. N2 - Magnetic random access memory (MRAM) ist eine Technologie, die darauf abzielt dynamic RAM (DRAM) aufgrund der geringeren Energieaufnahme und ihrer magnetischen Beständigkeit zu ersetzen [Dong08]. In den letzten Jahren wurde der kommerzielle Fokus auf spin-transfer MRAM (STT-MRAM) gelegt. Bei diesen Systemen wird der Strom an zwei durch einen Isolator getrennte Ferromagneten (FM), einer freien Schicht und einer Referenzschicht gelegt. Je nach Stromrichtung kann sich die freie Schicht parallel oder anti-parallel zur Referenzschicht anordnen [Kim11]. Jedoch können die zur Ummagnetisierung notwendigen Ströme so hoch ausfallen, dass die Tunnelbarriere schaden nimmt, wodurch ein höherer Energieverbrauch und unzuverlässiges Verhalten hervorgerufen werden. An dieser Stelle besteht die Möglichkeit einen anderen Effekt auszunutzen, für den der Strom unter der freien Schicht angelegt wird, um die nächstgelegene Magnetisierung zu beeinflussen. Beim sogenannten spin-orbit torque (SOT) wird das magnetische Moment eines zur elektrischen Leitung beitragenden Elektrons auf die darüber liegende Magnetisierung übertragen. Dies geschieht entweder anhand des spin Hall effect (SHE) oder inverse spin galvanic effect (iSGE) [Manchon19]. Letzteres beschreibt eine Spinakkumulation aufgrund eines elektrischen Stromflusses, welche auch bei topologischen Isolatoren (TI) auftritt. Diese speziellen Materialsysteme besitzen leitende Oberflächenzustände, bei denen Impuls- und Spinvektor senkrecht aufeinander stehen (spin-momentum locking) und in der Probenebene liegen [Qi11]. Hieraus resultiert eine hohe Strom-zu-Spin Umwandlungsrate, wodurch sich TIs besonders gut für SOT Experimente eignen. Unter allen TIs ist HgTe das Materialsystem, welches zuverläassig als Isolator gewachsen werden kann. Die vorliegende Arbeit befasst sich mit der Entwicklung und dem Aufbau einer mikrostrukturierten Apparatur zur Bestimmung von SOT Parametern (SOT-Struktur) in einem CdTe/CdHgTe/HgTe/CdHgTe Materialsystem. Es umfasst die Entwicklung einer Tunnelbarriere (ZrOx), sowie die Untersuchung des Verhaltens ferromagnetischer Strukturen auf der Oberfläche von trockengeätztem HgTe. Die Kernaussage dieser Arbeit ist, dass das vorliegende erfolgreich realisierte SOT-device die höchsten bis dato bekannten Effizienzen in der Ummagnetisierung von planar anisotropischen ferromagnetischen Strukturen aufweist. Um die Hybridisierung zwischen HgTe und dem darüber liegenden FM und somit einen Zusammenbruch der Oberflächenzustände zu vermeiden, muss zwischen den beiden Materialien eine Tunnelbarriere eingefügt werden [Zhang16]. Neben der Verhinderung der Hybridisierung, sorgt die Tunnelbarriere für eine Verminderung des Leckstromes, wodurch der größte Teil des elektrischen Stroms zur Spinakkumulation beitragen kann. Zudem werden Störungen bei der Widerstandsmessung des ferromagnetischen Schichtsystems reduziert. Kapitel 3 befasst sich mit der Erforschung von Tunnelcharakteristiken von ZrOx auf trockengeätztem HgTe. Es werden dünne Schichten verwendet, da die Wechselwirkung zwischen Spin und Magnetisierung mit dem Abstand zueinander abnimmt. Andererseits führt eine zu dünne Isolatorschicht zu einem hohen Leckstrom, welcher die Widerstandsmessung der ferromagnetischen Schichtstruktur stark beeinflusst. Folglich wurde eine optimale Isolatordicke bestimmt, die 10 ALD Zyklen (\(d\approx1,6\rm\, nm\)) entspricht und ein Widerstandsflächenprodukt von \(R\cdot A \approx 3\rm\, k\Omega\mu m^{2}\) ergibt. Dies entspricht einem Tunnelwiderstand von \(R_{T}\approx 20\rm\, k\Omega\) bei einer Strukturfläche von \(A_{T} = 0.12\rm\, \mu m^2\). Es werden mehrere Proben unterschiedlicher Dicke hergestellt und auf ihre Tunnelcharakteristiken untersucht. Das Widerstandsflächenprodukt in Abhängigkeit von der Barrierendicke zeigt lineares Verhalten auf einer logarithmischen Skala. Darüber hinaus weisen alle funktionierenden Proben nicht-lineare I-V Kurven und parabolische dI/dV Verläufe auf. Der Tunnelwiderstand \(R_{T}\) steigt mit abnehmender Temperatur. Die genannten Eigenschaften sind typisch für Tunnelbarrieren ohne lokal stark ausgedünnte Stellen (pinholes) [Jonsson00]. Am Ende von Kapitel 3 wird die Möglichkeit zur Bestimmung thermischer Eigenschaften von HgTe erörtert. Hierbei wird das Signal der zweiten Harmonischen eines AC Anregungsstromes, der unterhalb der Tunnelbarriere verläuft, gemessen, um den diffusiven Seebeck Effekt durch die geheizten Elektronen zu bestimmen. Messungen zeigen jedoch, dass das gemessene Signal zum größten Teil aus der ersten Harmonischen besteht. Mit Hilfe von Schaltkreissimulationen kann gezeigt werden, dass dieses Verhalten vor allem der Asymmetrie der Tunnelbarriere (Ein- und Ausstiegspunkt der Elektronen) geschuldet ist. Eine ferromagnetische Schichtstruktur, bestehend aus PY/Cu/CoFe, dient als ein Sensor zur Erfassung von Magnetisierungsänderungen, die durch externe magnetische Felder und Spinakkumulationen hervorgerufen werden. Die erwähnte Schichtstruktur weist einen Riesenmagnetowiderstand (GMR) auf, der mit Hilfe einer Widerstandsbrücke gemessen wird. Die größte Besonderheit bei der Ablagerung einer GMR Schichtstruktur auf trockengeätztem \mt ist die Ausbildung einer leichten Richtung (easy axis) entlang nur einer bestimmten Kristallachse (\((110)\) oder \((1\overline{1}0)\)). Der Grund für diese Anisotropie ist weiterhin unbekannt. Mögliche Ursachen wie der Einfluss des terminierenden Materials, miscut, Furchenbildung während des IBE und Wellenbildung durch Magnetronsputtern konnten ausgeschlossen werden. Es besteht die vage Vermutung, dass die Oberflächenzustände von \mt in Verbindung mit der Ausbildung der easy axis stehen. Dies gilt es jedoch in zukünftigen Studien kritisch zu prüfen. Als Folge dieser unwerwarteten Anisotropie muss jeder neue CdTe/CdHgTe/HgTe/CdHgTe wafer zunächst im SQUID charakterisiert werden, um die easy axis einmalig zu bestimmen. Anhand von ferromagnetischen Resonanzmessungen (FMR) konnten die obigen Beobachtungen bestätigt werden. Die Schichtstrukturen (pillars) weisen eine elliptische Form auf, sodass die Formanisotropie die Bildung einer easy axis entlang einer bestimmten Richtung begünstigt. Über 8 Millionen Ellipsen werden verwendet, um ein SQUID Signal von \(m > 10^{-5}\rm\, emu\) zu generieren. Hierdurch werden die charakteristischen Merkmale eines durchschnittlichen nano pillars unter dem Einfluss eines externen Magnetfeldes bestimmt. Wie auch bei größeren Strukturen weist ein durchschnittlicher pillar eine stufenförmige Hysterese auf. Durch Umkehrung des Magnetfelds am Ort des Zwischenzustandes lässt sich beweisen, dass es sich um einen tatsächlichen irreversiblen stabilen anti-ferromagnetischen Zustand handelt. Dieser Zustand liegt bei beiden Magnetfeldrichtungen für \(m=0\) vor, was zeigt, dass Py und CoFe anti-ferromagnetisch koppeln. Die Geometrie der SOT-Struktur ist so gewählt, dass die strominduzierte Spinakkumulation entweder parallel oder anti-parallel zum effektiven Magnetfeld \(\vec{B}_{eff}=\vec{B}_{ext}+\vec{B}_{aniso}+\vec{B}_{shape}\), welches auf den pillar wirkt. Dieser Spin wechselwirkt mit der Magnetisierung des Py, was eine Richtungsänderung der Magnetisierung durch ein Drehmoment \(\vec{T}\) (torque) bewirkt. Im Allgemeinem lässt sich diese torque in zwei Komponenten, eine feldähnliche (field-like) torque \(\vec{\tau}_{FL}\) und eine dämpfende (damping-like) torque \(\vec{\tau}_{DL}\), aufspalten [Manchon19]. Im Falle von TIs hängt \(\vec{T}\) zusätzlich von der z-Komponente des magnetischen Moments \(\vec{\hat{m}}\) ab [Ndiaye17]. Im hier vorliegenden Fall liegt die Magnetisierung von Py in der Probenebene (\(m_{z}=0\)), wodurch \(\tau_{DL} = 0\). Folglich ergibt sich, unter der Annahme \(\vec{S}\parallel\left(\vec{\hat{z}}\times\vec{j}\right)\) und \(\vec{j}\parallel\vec{\hat{y}}\), als einziges spinabhängiges Magnetfeld \(\vec{B}_{FL}=\tau_{FL}\cdot\vec{\hat{x}}\), welches parallel oder anti-parallel zu \(\vec{B}_{eff}\) liegt. Die Bestimmung von \(\vec{B}_{FL}\) erfolgt somit auf folgende Art und Weise. Zunächst wird ein hohes \(B_{ext}\) entlang der easy axis des nano pillars angelegt. Anschließend muss \(B_{ext}\) soweit reduziert werden bis der magnetische Zustand nur wenige Oe vor dem Umklappprozess bei \(B_{ext,0}\) liegt. An der Stelle \(\Delta B = B_{ext}-B_{ext,0}\approx 0.5\rm\, Oe\) sollte der Zustand mit geringerem GMR für eine längere Zeitspanne (\(10-30\rm\, min\)) erhalten bleiben, um eine Ummagnetisierung aufgrund von Schwankungen auszuschließen. Nun wird ein positiver oder negativer Strom an den unter der GMR-Struktur liegenden Kanal angelegt. Der Umklapprozess der Py Magnetisierung erfolgt für nur eine der beiden Stromrichtungen, wodurch eine Beteiligung thermischer Effekte ausgeschlossen werden kann. Bei \(\Delta B\neq 0\) reichen bereits Stromdichten in der Größenordnung von \(j\approx 10^{4}\rm\, A/cm^{2}\) aus, um eine Ummagnetisierung herbeizuführen. In allen Versuchen sinkt die Effizienz \(\Delta B/j\) mit der Stromdichte. Zudem zeigt \(\Delta B/j\) eine starke Temperaturabhängigkeit, bei der \(\Delta B/j\) Werte für \(T=1.8\rm\, K\) und \(j\approx0\) bis zu 20 mal höher sind als bei \(T=4.2\rm\, K\). Eine solche Temperaturabhängigkeit weist stark darauf hin, dass die Ummagnetisierung nicht durch Biot-Savart Felder hervorgerufen wird. Zudem wurde das durch einen elektrischen Strom generierten Biot-Savart Feld auf vier verschiedene Weisen berechnet. Die hierbei verwendeten Modelle umfassen: einen unendlich langen im Querschnitt rechteckigen Draht, zwei unendlich ausgebreitete Ebenen, ein komplettes Volumen, sowie zwei Ebenen mit geringer Dicke. Bei jedem Modell ist die berechnete Effizienz mindestens drei mal kleiner als die Beobachtung. Die höchsten in dieser Arbeit gemessenen Effizienzen sind bis zu 10 mal höher als in Materialsystemen, die aus Schwermetallen und FM bestehen. Im Gegensatz zu anderen Gruppen werden in dieser Arbeit direkte Messmethoden zur Ermittlung von SOT Parametern (wie \(B_{FL}\)) verwendet. Die meisten dieser Gruppen verlassen sich auf spin-transfer FMR (ST-FMR) Messungen. Dabei wird ein AC Signal zur Anregung verwendet und zeitgleich die zweite Harmonische als Antwort gemessen. Hieraus werden anhand eines theoretischen Modells SOT Parameter (wie \(\tau_{FL}\) und \(\tau_{DL}\)) durch Fits bestimmt. Materialsysteme, die aus TIs und magnetischen Isolatoren (MI) bestehen, weisen dagegen bis zu 10 mal höhere Effizienzen auf [Khang18,Li19]. In diesen Fällen zeigt die Magnetisierung der MI aus der Ebene heraus, was sich konzeptionell von planar anisotropische Magnetisierungen unterscheidet, welche in unseren Geometrien vorliegt. Der Vorteil von planar anisotropischen Magnetisierungen ist ihre einfache Realisierbarkeit [Bhatti17]. Hierbei müssen lediglich elliptische Strukturen lithographisch implementiert werden, während bei Systemen mit senkrechter Magnetisierung eine passende Materialkombination erforscht werden muss [Apalkov16]. Trotz der Tatsache, dass in unserem Fall nur \(\tau_{FL}\) zum Umklappen der Magnetisierung \(m\) beiträgt, weisen unsere SOT-devices die bis dato höchsten gemessenen Effizienzen in der Klasse von in-der-Ebene magnetisierten Schichtstrukturen aller Materialsysteme auf. KW - spin-orbit-torque KW - magnetization KW - mram KW - topological insulator Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-240490 ER - TY - THES A1 - Elsholz, Markus T1 - Das akademische Selbstkonzept angehender Physiklehrkräfte als Teil ihrer professionellen Identität – Dimensionalität und Veränderung während einer zentralen Praxisphase T1 - Pre-Service Teachers‘ Academic Self-Concept as Part of their Professional Identity – Dimensionality and Change during a Practical Training N2 - Die vorliegende Arbeit untersucht die Struktur und die Veränderung des akademischen Selbstkonzepts angehender Physiklehrkräfte. Als selbstbezogene Kognition wird es als eine Grundlage der professionellen Identität von Lehrkräften verstanden. Selbstkonzepte bilden sich aus der Kategorisierung selbstrelevanter Informationen, die eine Person in verschiedenen Kontexten sammelt, bewertet und interpretiert. Für angehende Lehrkräfte wird der professionelle Kontext durch die Struktur und die Inhalte des Lehramtsstudiums gebildet. Daraus folgt die erste zentrale Hypothese der Arbeit: Im akademischen Selbstkonzept angehender Physiklehrkräfte lassen sich drei Facetten empirisch trennen, die den inhaltlichen Domänen des Lehramtsstudiums entsprechen. Demnach strukturieren Studierende ihre Fähigkeitszuschreibungen in Bezug auf (1) die Fachwissenschaft Physik, (2) die Fachdidaktik Physik sowie (3) die Erziehungswissenschaften. Konkrete Erfahrungen bilden als Quelle selbstrelevanter Informationen die Basis für den Aufbau bzw. die Veränderung von domänenspezifischen Selbstkonzeptfacetten. Sie stabilisieren das Selbstkonzept, falls sie im Einklang mit dem bisherigen Bild der Person von sich selbst stehen bzw. können eine Veränderung des Selbstkonzepts initiieren, wenn sie sich nicht konsistent in dieses Bild einfügen lassen. Vor diesem Hintergrund folgt die zweite zentrale Hypothese der vorliegenden Arbeit: Während der Praxisphasen des Studiums verändert sich das akademische Selbstkonzept der Studierenden. Die Hypothesen werden mit Ansätzen der latenten Modellierung untersucht. Mittels konfirmatorischer Faktorenanalyse wird die empirische Trennbarkeit der drei angenommenen Facetten bestätigt. In einer querschnittlichen Betrachtung zeigt sich ein deutlicher Einfluss des Geschlechts der Studierenden auf den Zusammenhang zwischen ihrem fachdidaktischen Selbstkonzept und ihrer bisherigen Praxiserfahrung. Die längsschnittliche Analyse der Veränderung des Selbstkonzepts während einer zentralen fachdidaktischen Lehrveranstaltung mit ausgeprägten Praxisphasen (Lehr-Lern-Labor-Seminar) wird mit einem latenten Wachstumskurvenmodell untersucht. Das auf die Fachdidaktik Physik bezogene Selbstkonzept steigt während des Seminars leicht an, wenn die Studierenden zum Seminarbeginn bereits über Praxiserfahrung verfügten. Fehlt diese, so ist ein leichter Rückgang in der Ausprägung des Selbstkonzepts feststellbar, der für weibliche Studierende stärker ausfällt als für ihre männlichen Kommilitonen. Mit den Befunden zu Struktur und Veränderung des akademischen Selbstkonzepts angehender Physiklehrkräfte trägt die vorliegende Arbeit dazu bei, die überwiegend qualitativen Analysen von Identitätsprozessen bei Studierenden durch den Einsatz eines theoretisch fundierten und klar umrissenen Konstrukts um eine quantitative Perspektive zu ergänzen. N2 - This study examines the structure and the change of the academic self-concept of preservice physics teachers. As a self-directed cognition, self-concept is understood as a basis for the professional identity of teachers. Self-concepts are formed by the categorization of context specific self-relevant information that a person collects, evaluates and interprets. In teacher education, the professional context for prospective teachers is formed by the structure and content of the specific teacher education program. Therefore the first central hypothesis of this thesis can be deduced: In the academic self-concept of pre-service physics teachers three facets can be separated empirically, which correspond to the content domains of the teacher education program, i. e. (1) physics, (2) physics didactics, and (3) educational sciences. Self-relevant experiences form the basis for building up or changing domain-specific self-concept facets. They are the source of self-relevant information that either stabilizes the self-concept if it is consistent with the person’s perception of him- or herself or can initiate a self-concept change if it can not be consistently integrated. Against this background, the second central hypothesis of the study follows: Practical trainings in initial teacher education are accompanied by a change in the pre-service teachers’ academic self-concept. The hypotheses are examined within a latent modeling approach. Confirmatory factor analysis confirms the empirical separability of the three assumed self-concept facets. A cross-sectional analysis reveals the influence of gender on the interrelation between pre-service teachers’ didactic self-concept and their prior teaching experience. The change in self-concept accompanying to a mandatory course in physics didactics and a practical training (Lehr-Lern-Labor-Seminar) is evaluated fitting a latent growth curve model. The self-concept facet related to physics didactics slightly increases during the seminar if the pre-service teachers already had teaching experience at the beginning of the seminar. In the subsample without teaching experience, a slight decline in the self-concept is noticeable. With the findings on the structure and change of the academic self-concept, this study contributes to supplementing the predominantly qualitative analyzes of identity processes in prospective teachers with a quantitative perspective by using a theoretically founded and clearly defined construct. KW - Selbstbild KW - Identität KW - Lehrerbildung KW - Analyse latenter Strukturen KW - Fachdidaktik KW - Selbstkonzept KW - self-concept KW - pre-service teachers KW - Lehramtsstudierende Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-172153 N1 - Erscheint auch als Buchhandelsausgabe im Logos Verlag Berlin (2019) ER - TY - THES A1 - Proppert, Sven Martin T1 - Design, implementation and characterization of a microscope capable of three-dimensional two color super-resolution fluorescence imaging T1 - Design, Implementierung und Charakterisierung eines Mikroskops für dreidimensionale zwei Farben superhochauflösende Fluoreszenz-Bildgebung N2 - This thesis reviews the fundamentals of three-dimensional super-resolution localization imaging. In order to infer the axial coordinate of the emission of single fluorophores, the point spread function is engineered following a technique usually referred to as astigmatic imaging by the introduction of a cylindrical lens to the detection path of a microscope. After giving a short introduction to optics and localization microscopy, I outline sources of aberrations as frequently encountered in 3D-localization microscopy and will discuss their respective impact on the precision and accuracy of the localization process. With the knowledge from these considerations, experiments were designed and conducted to verify the validity of the conclusions and to demonstrate the abilities of the proposed microscope to resolve biological structures in the three spatial dimensions. Additionally, it is demonstrated that measurements of huge volumes with virtually no aberrations is in principle feasible. During the course of this thesis, a new method was introduced for inferring axial coordinates. This interpolation method based on cubic B-splines shows superior performance in the calibration of a microscope and the evaluation of subsequent measurement and will therefore be used and explained in this work. Finally, this work is also meant to give future students some guidance for entering the field of 3D localization microscopy and therefore, detailed protocols are provided covering the specific aspects of two color 3D localization imaging. N2 - In dieser Arbeit werden die Grundlagen der dreidimensionalen hochauflösenden Lokalisationsmikroskopie erarbeitet und daraus Spezifikationen für ein geeignetes Mikroskop abgeleitet. Zur Gewinnung der axialen Koordinate der Emission einzelner Farbstoffe wird die Punktspreizfunktion in der Detektion astigmatisch mithilfe einer zylindrischen Linse verändert. Nach einer kurzen Einleitung in die Grundzüge der Optik und der Lokalisationsmikroskopie werden die Ursachen für typische Aberrationen besprochen, wie sie in der 3D-Lokalisationsmikroskopie häufig auftreten. Weiterhin wird der Einfluss dieser Aberrationen auf die erreichbare Präzision und Exaktheit des Lokalisationsprozesses behandelt. Mit dem Wissen aus diesen Überlegungen wurden Experimente entworfen und durchgeführt um die getroffenen Schlussfolgerungen zu validieren und zu demonstrieren, dass das vorgeschlagene Mikroskop dazu in der Lage ist, biologische Strukturen in den drei räumlichen Dimensionen aufzulösen. Weiterhin wird gezeigt, dass beinahe aberrationsfreie Mikroskopie großer Volumina prinzipiell möglich ist. Während der Arbeit an dieser Promotion wurde eine neue Methode zur Gewinnung der axialen Koordinaten eingeführt. Diese auf kubischen B-splines basierende Interpolationsmethode stellte sich als anderen Routinen überlegen in der Kalibration eines Mikroskops und der anschließenden Auswertung von Messungen heraus. Deshalb wird dieses Verfahren in der vorliegenden Arbeit verwendet und erklärt. Da diese Doktorarbeit auch den Anspruch hat, zukünftigen Studenten den Einstieg in die hochauflösende 3D Mikroskopie zu erleichtern, werden abschließend detaillierte Protokolle für spezifische Aspekte der zwei Farben 3D Lokalisationsmikroskopie zur Verfügung gestellt. KW - Dimension 3 KW - aberration KW - Einzelmolekülmikroskopie KW - single molecule microscopy KW - 3D KW - super-resolution KW - Mikroskopie KW - Hochauflösendes Verfahren KW - Aberration Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-107905 ER - TY - THES A1 - Pres, Sebastian T1 - Detection of a plasmon-polariton quantum wave packet by coherent 2D nanoscopy T1 - Nachweis eines Plasmon-Polariton-Quantenwellenpakets durch kohärente 2D-Nanoskopie N2 - Plasmonic nanostructures are considered promising candidates for essential components of integrated quantum technologies because of their ability to efficiently localize broad-band electromagnetic fields on the nanoscale. The resulting local near field can be understood as a spatial superposition of spectrally different plasmon-polariton modes due to the spectrally broad optical excitation, and thus can be described as a classical wave packet. Since plasmon polaritons, in turn, can transmit and receive non-classical light states, the exciting question arises to what extent they have to be described as quantum mechanical wave packets, i.e. as a superposition of different quantum states. But how to probe, characterize and eventually manipulate the quantum state of such plasmon polaritons? Up to now, probing at room temperatures relied completely on analyzing quantum optical properties of the corresponding in-going and out-going far-field photon modes. However, these methods so far only allow a rather indirect investigation of the plasmon-polariton quantum state by means of transfer into photons. Moreover, these indirect methods lack spatial resolution and therefore do not provide on-site access to the plasmon-polariton quantum state. However, since the spectroscopic method of coherent two-dimensional (2D) nanoscopy offers the capability to follow the plasmon- polariton quantum state both in Hilbert space and in space and time domain a complete characterization of the plasmon polariton is possible. In this thesis a versatile coherent 2D nanoscopy setup is presented combining spectral tunability and femtosecond time resolution with spatial resolution on the nanometer scale due to the detection of optically excited nonlinear emitted electrons via photoemission electron microscopy (PEEM). Optical excitation by amplitude- and phase-shaped, systematically-modified and interferometric-stable multipulse sequences is realized, and characterized via Fourier-transform spectral interferometry (FTSI). This linear technique enables efficient data acquisition in parallel to a simultaneously performed experiment. The full electric-field reconstruction of every generated multipulse sequence is used to analyze the effect of non-ideal pulse sequences on the two-dimensional spectral data of population-based multidimensional spectroscopy methods like, e.g., the coherent 2D nanoscopy applied in this thesis. Investigation of the spatially-resolved nonlinear electron emission yield from plasmonic gold nanoresonators by coherent 2D nanoscopy requires a quasi-particle treatment of the addressed plasmon-polariton mode and development of a quantum model to adequately describe the plasmon-assisted multi-quantum electron emission from nanostructures. Good agreement between simulated and experimental data enables to connect certain spectral features to superpositions of non-adjacent plasmon-polariton quantum states, i.e, non-adjacent occupation-number states of the underlying quantized, harmonic oscillator, thus direct probing of the plasmon-polariton quantum wave packet at the location of the nanostructure. This is a necessary step to locally control and manipulate the plasmon-polariton quantum state and thus of general interest for the realization of nanoscale quantum optical devices. N2 - Plasmonische Nanostrukturen gelten als vielversprechende Kanditaten für wesentliche Bestandteile integrierter Quantentechnologien, da sie in der Lage sind, breitbandige elektromagnetische Felder auf der Nanoskala effizient zu lokalisieren. Durch die spektral breitbandige optische Anregung kann das so erzeugte lokale Nahfeld als räumliche Überlagerung von spektral verschiedenen Plasmon-Polariton Moden aufgefasst und daher als klassisches Wellenpaket beschrieben werden. Da Plasmon-Polaritonen wiederum nichtklassische Lichtzustände übertragen und erhalten können, stellt sich allerdings die spannende Frage, inwieweit man sie als quantenmechanische Wellenpakete, sprich eine Superposition von unterschiedlichen Quantenzuständen, beschreiben muss. Doch wie lässt sich der Quantenzustand solcher Plasmon-Polaritonen untersuchen, charakterisieren und schließlich manipulieren? Bislang beruhte die Untersuchung bei Raumtemperatur vollständig auf der Analyse der quantenoptischen Eigenschaften der entsprechenden ein- und ausgehenden Fernfeld-Photonenmoden. Diese Methoden erlauben allerdings bisher nur eine eher indirekte Untersuchung des Plasmonen-Polaritonen-Quantenzustands mittels Überführung in Photonen. Darüber hinaus mangelt es diesen indirekten Methoden an räumlicher Auflösung und sie bieten daher keinen Zugang zum Plasmonen-Polaritonen-Quantenzustand am Ort der Nanostruktur. Die spektroskopische Methode der kohärenten 2D-Nanoskopie bietet allerdings die Möglichkeit, den Plasmon-Polariton-Quantenzustand sowohl im Hilbert-Raum als auch im Raum- und Zeitbereich zu verfolgen, wodurch eine vollständige Charakterisierung des Plasmon-Polaritons möglich ist. In dieser Arbeit wird ein vielseitiger experimenteller Aufbau zur kohärenten zweidimensionalen (2D)-Nanoskopie vorgestellt, der spektrale Durchstimmbarkeit und Femtosekunden-Zeitauflösung mit räumlicher Auflösung auf der Nanometerskala durch den Nachweis optisch angeregter nichtlinear-emittierter Elektronen mittels Photoemissionselektronenmikroskopie (PEEM) kombiniert. Die optische Anregung durch amplituden- und phasengeformte, systematisch modifizierte und interferometrisch stabile Multipulssequenzen wird realisiert und über Fouriertransformierte Spektrale Interferenz (FTSI) charakterisiert. Diese lineare Technik ermöglicht eine effiziente Datenerfassung parallel zu einem gleichzeitig durchgeführten Experiment. Die vollständige Rekonstruktion des elektrischen Feldes jeder erzeugten Multipulssequenz wird verwendet, um die Auswirkung nicht-idealer Pulssequenzen auf die zweidimensionalen Spektraldaten von populationsbasierten multidimensionalen Spektroskopiemethoden, wie beispielsweise der in dieser Arbeit verwendeten kohärenter 2D-Nanoskopie, zu analysieren. Die Untersuchung der räumlich aufgelösten nichtlinearen Elektronenemissionsausbeute von plasmonischen Gold-Nanoresonatoren durch kohärente 2D-Nanoskopie erfordert eine Quasiteilchen-Behandlung der angesprochenen Plasmon-Polariton-Mode und die Entwicklung eines Quantenmodells, um die plasmonenunterstützte Multiquanten-Elektronenemission von Nanostrukturen korrekt zu beschreiben. Die gute Übereinstimmung zwischen simulierten und experimentellen Daten ermöglicht es, bestimmte spektrale Merkmale mit Überlagerungen von nicht-benachbarten Plasmon-Polariton-Quantenzuständen, sprich nicht-benachbarter Besetzungszahlzustände des zugrunde liegenden quantisierten, harmonischen Oszillators, in Verbindung zu bringen und so direkt das Plasmon-Polariton-Quantenwellenpaket am Ort der Nanostruktur zu untersuchen. Dies ist ein notwendiger Schritt, um den Plasmon-Polariton-Quantenzustand lokal zu kontrollieren und zu manipulieren, und somit von allgemeinem Interesse für die Realisierung von quantenoptischen Geräten im Nanomaßstab. KW - Coherent Multidimensional Spectroscopy KW - Photoemissionselektronenmikroskopie KW - Coherent Two-dimensional Nanoscopy KW - Fourier-transform spectral interferometry KW - Quantum Plasmonics KW - Femtosecond Pulse Shaping Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-348242 ER - TY - THES A1 - Krause, Stefan T1 - Determination of the transport levels in thin films of organic semiconductors T1 - Bestimmung der Tranportniveaus in organischen Dünnschichten N2 - The approach of using the combination of Ultraviolet (UPS) and Inverse Photoemission (IPS) to determine the transport levels in thin films of organic semiconductors is the scope of this work. For this matter all influences on the peak position and width in Photoelectron Spectroscopy are discussed with a special focus on organic semiconductors. Many of these influences are shown with experimental results of the investigation of diindenoperylene on Ag(111). These findings are applied to inorganic semiconductors silicon in order to establish the use of UPS and IPS on a well-understood system. Finally, the method is used to determine the transport level of several organic semiconductors (PTCDA, Alq3, CuPc, DIP, PBI-H4) and the corresponding exciton binding energies are calculated by comparison to optical absorption data. N2 - Das Ziel dieser Arbeit ist mit Hilfe von Ultravioletter (UPS) und Inverser Photoelektronenspektroskopie (IPS) die Transportniveaus in organischen Dünnschichten zu bestimmen. Um dies zu erreichen, werden zunächst alle Einflüsse auf die Signalposition und -breite in der Photoelektronenspektroskopie mit besonderem Augenmerk auf die organischen Halbleiter diskutiert. Viele dieser Einflüsse werden anhand von experimentelle Daten der Untersuchung von Diindenoperylene auf Ag(111) gezeigt. Basierend auf dieser Diskussion wird die Verwendung von UPS und IPS an dem anorganischen und gut verstandenem Halbleiter Silizium etabliert. Zuletzt wird die nun etablierte Methode auf organische Halbleiter (PTCDA, Alq3, CuPc, DIP, PBI-H4) angewandt und die Lage deren Transportniveaus bestimmt. Durch den Vergleich mit optischen Absorptionsdaten können darüber hinaus auch Exzitonenbindungsenergien in diesen Materialien berechnet werden. KW - Organischer Halbleiter KW - Dünne Schicht KW - Transportprozess KW - Photoelektronenspektroskopie KW - Energielücke KW - Halbleiterschicht KW - Siliciumhalbleiter KW - Metall-Halbleiter-Kontakt KW - Ultraviolett-Photoelektronenspektroskopie KW - Inverse Photoemissions KW - transport gap KW - organic semiconductors KW - UPS KW - IPES KW - exciton binding energy Y1 - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-40470 ER - TY - THES A1 - Breuer, Felix T1 - Development and Applications of Efficient Strategies for Parallel Magnetic Resonance Imaging T1 - Entwicklung und Anwendungen von effizienten Strategien in der Parallelen Magnetresonanztompgraphie N2 - Virtually all existing MRI applications require both a high spatial and high temporal resolution for optimum detection and classification of the state of disease. The main strategy to meet the increasing demands of advanced diagnostic imaging applications has been the steady improvement of gradient systems, which provide increased gradient strengths and faster switching times. Rapid imaging techniques and the advances in gradient performance have significantly reduced acquisition times from about an hour to several minutes or seconds. In order to further increase imaging speed, much higher gradient strengths and much faster switching times are required which are technically challenging to provide. In addition to significant hardware costs, peripheral neuro-stimulations and the surpassing of admissable acoustic noise levels may occur. Today’s whole body gradient systems already operate just below the allowed safety levels. For these reasons, alternative strategies are needed to bypass these limitations. The greatest progress in further increasing imaging speed has been the development of multi-coil arrays and the advent of partially parallel acquisition (PPA) techniques in the late 1990’s. Within the last years, parallel imaging methods have become commercially available,and are therefore ready for broad clinical use. The basic feature of parallel imaging is a scan time reduction, applicable to nearly any available MRI method, while maintaining the contrast behavior without requiring higher gradient system performance. PPA operates by allowing an array of receiver surface coils, positioned around the object under investigation, to partially replace time-consuming spatial encoding which normally is performed by switching magnetic field gradients. Using this strategy, spatial resolution can be improved given a specific imaging time, or scan times can be reduced at a given spatial resolution. Furthermore, in some cases, PPA can even be used to reduce image artifacts. Unfortunately, parallel imaging is associated with a loss in signal-to-noise ratio (SNR) and therefore is limited to applications which do not already operate at the SNR limit. An additional limitation is the fact that the coil array must provide sufficient sensitivity variations throughout the object under investigation in order to offer enough spatial encoding capacity. This doctoral thesis exhibits an overview of my research on the topic of efficient parallel imaging strategies. Based on existing parallel acquisition and reconstruction strategies, such as SENSE and GRAPPA, new concepts have been developed and transferred to potential clinical applications. N2 - In den späten 80er Jahren entwickelte sich die Magnetresonanz-Tomographie (MRT), die bis dato lediglich in Forschungseinrichtungen etabliert war, zu einem der wichtigsten Verfahren in der klinischen Diagnostik. Allerdings erfordern nahezu alle bestehenden klinischen Anwendungsgebiete sowohl eine hohe räumliche als auch eine hohe zeitliche Auflösung für eine optimale Detektion und Klassifizierung von Krankheitsbildern. Der bisherige Ansatz, diesen zunehmenden Anforderungen an die klinische MRT gerecht zu werden, bestand vor allem in der stetigen Verbesserung von Gradientensystemen die mit immer höheren Gradientenstärken und schnelleren Schaltzeiten aufwarteten. Die technischen Fortschritte, sowie schnelle Bildgebungsmethoden erlaubten es, Messzeiten von etwa einer Stunde auf nur wenige Minuten oder sogar Sekunden zu reduzieren. Eine weitere Verkürzung der Experimentdauer mittels noch leistungsfähigeren Gradientensystemen ist jedoch technisch schwierig zu realisieren. Ausserdem gehen enorm hohe Entwicklungs und Materialkosten mit den erhöhten Anforderungen einher. Es kommt hinzu, dass noch stärkere Gradienten und noch schnellere Schaltzeiten zu peripheren Neurostimulationen und zur Überschreitung von zulässigen akustischen Grenzwerten führen können. Heutige Gradientensysteme arbeiten schon sehr nahe an den Grenzen der zulässigen Sicherheitsbestimmungen. Deshalb werden alternative Strategien benötigt, um weitere Messzeitverkürzungen realisieren zu können. Der bisher erfolgreichste Ansatz bestand in der Entwicklung von Mehr-Kanal-Spulen-Anordnungen und damit verknüpft der darauffolgenden Einführung der parallellen Bildgebung in den späten 90er Jahren. In den letzten 5 Jahren haben sich parallele Bildgebungsmethoden an den klinischen Tomographen etabliert und nahezu alle Herstellerfirmen stellen diese Technik kommerziell zur Verfügung. Die parallele Bildgebung ermöglicht eine Messzeitverkürzung, die prinzipiell auf jede bestehende Bildgebungsmethode angewendet werden kann, ohne dabei das Kontrastverhalten zu verändern und ohne höhere Gradientenleistung zu beanspruchen. In der parallellen Bildgebung übernimmt die Mehr-Kanal-Spulen-Anordnung teilwiese die Ortskodierung, die normalerweise durch zeitaufwendiges Schalten von Magnetfelgradienten erzeugt wird. Mit dieser Strategie kann bei gleicher Messzeit die örtliche Auflösung verbessert, oder bei gleicher Auflösung die Messzeit verkürzt werden. Ausserdem können mit hilfe der parallelen MRT in manchen Fällen Bildartefakte signifikant reduziert werden. Allerdings ist mit der parallelen Bildgebung immer ein Signal zu Rausch (SNR) Verlust verbunden, der diese Methode auf klinische Anwendungen begrenzt, die nicht bereits am SNR-Limit betrieben werden. Ausserdem muß die Spulenanordnung genug Sensitivitätsvariationen über das zu untersuchende Objekt bereitstellen, um ausreichende Kodierfunktion zu gewährleisten. Diese Dissertationsarbeit liefert einen Überblick über meine Forschungsarbeit zum Thema “Entwicklung und Anwendung von effizienten Strategien in der parallelen MRT”. Basierend auf bestehenden parallelen Akquisitions und Rekonstruktionstechniken, wie beispielsweise SENSE und GRAPPA, wurden neue Konzepte entwickelt und auf mögliche klinische Fragestellungen angewandt. KW - NMR-Bildgebung KW - Paralleler Prozess KW - Parallele Bildgebung KW - SENSE KW - GRAPPA KW - TGRAPPA KW - CAIPIRINHA KW - dynamische Bildgebung KW - Parallel imaging KW - SENSE KW - GRAPPA KW - TGRAPPA KW - CAIPIRINHA KW - dynamic imaging Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-20683 ER - TY - THES A1 - Ehses, Philipp T1 - Development of new Acquisition Strategies for fast Parameter Quantification in Magnetic Resonance Imaging T1 - Entwicklung neuer Aufnahmeverfahren zur schnellen Parameterbestimmung in der Magnetresonanztomographie N2 - Magnetic resonance imaging (MRI) is a medical imaging method that involves no ionizing radiation and can be used non-invasively. Another important - if not the most important - reason for the widespread and increasing use of MRI in clinical practice is its interesting and highly flexible image contrast, especially of biological tissue. The main disadvantages of MRI, compared to other widespread imaging modalities like computed tomography (CT), are long measurement times and the directly resulting high costs. In the first part of this work, a new technique for accelerated MRI parameter mapping using a radial IR TrueFISP sequence is presented. IR TrueFISP is a very fast method for the simultaneous quantification of proton density, the longitudinal relaxation time T1, and the transverse relaxation time T2. Chapter 2 presents speed improvements to the original IR TrueFISP method. Using a radial view-sharing technique, it was possible to obtain a full set of relaxometry data in under 6 s per slice. Furthermore, chapter 3 presents the investigation and correction of two major sources of error of the IR TrueFISP method, namely magnetization transfer and imperfect slice profiles. In the second part of this work, a new MRI thermometry method is presented that can be used in MRI-safety investigations of medical implants, e.g. cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). One of the major safety risks associated with MRI examinations of pacemaker and ICD patients is RF induced heating of the pacing electrodes. The design of MRI-safe (or MRI-conditional) pacing electrodes requires elaborate testing. In a first step, many different electrode shapes, electrode positions and sequence parameters are tested in a gel phantom with its geometry and conductivity matched to a human body. The resulting temperature increase is typically observed using temperature probes that are placed at various positions in the gel phantom. An alternative to this local thermometry approach is to use MRI for the temperature measurement. Chapter 5 describes a new approach for MRI thermometry that allows MRI thermometry during RF heating caused by the MRI sequence itself. Specifically, a proton resonance frequency (PRF) shift MRI thermometry method was combined with an MR heating sequence. The method was validated in a gel phantom, with a copper wire serving as a simple model for a medical implant. N2 - Die Magnetresonanztomographie (MRT) zeichnet sich als medizinisches Bildgebungsverfahren dadurch aus, dass sie ohne ionisierende Strahlung auskommt und nicht-invasiv einsetzbar ist. Ein weiterer wichtiger - wenn nicht der wichtigste - Grund für die weite und wachsende Verbreitung der MRT in der klinischen Praxis ist ihr interessantes und hoch-flexibles Kontrastverhalten, und damit die gute Darstellbarkeit biologischen Gewebes. Die Hauptnachteile der MRT sind die, verglichen mit z.B. Computer-Tomographie (CT), langen Messzeiten und die damit direkt verbundenen hohen Untersuchungskosten. Der erste Teil dieser Arbeit beschreibt Verbesserungen der IR TrueFISP Methode zur MR-Parameterbestimmung. IR TrueFISP ist eine schnelle Methode zur gleichzeitigen Quantifizierung der Protonendichte, der longitudinalen Relaxationszeit T1, sowie der transversalen Relaxationszeit T2. In Kapitel 2 dieser Arbeit wird eine Methode zur Beschleunigung der IR TrueFISP Quantifizierung vorgestellt, die es erlaubt einen kompletten Relaxometrie-Datensatz in unter 6 s pro Schicht aufzunehmen. Weiterhin werden in Kapitel 3 zwei allgemeine Fehlerquellen der IR TrueFISP Methode untersucht und Korrekturverfahren vorgestellt. Im zweiten Teil dieser Arbeit werden neuartige MR-Thermometrie Methoden vorgestellt, die sich besonders zur Untersuchung der MR-Sicherheit von medizinischen Implanten, insbesondere Herzschrittmachern und implantierbaren Kardioverter-Defibrillatoren (ICDs), eignen. Momentan sind in den allermeisten Fällen MRT Untersuchungen an Herzschrittmacher- und ICD-Patienten aufgrund der damit verbundenen Risiken kontraindiziert. Das dabei am schwierigste in den Griff zu bekommende und damit größte Risiko ist die mögliche Schädigung des Myokards, hervorgerufen durch die von den geschalteten HF-Feldern induzierten Ströme in den Schrittmacherelektroden. Um eine MR-sichere Elektrode und/oder sichere Messprotokole zu entwickeln ist es notwendig viele verschiedene Elektroden, Elektrodenpositionen und Messparameter-Einstellungen in einem körperähnlichen Gel-Phantom untersucht. Die bei der jeweiligen Messung auftretenden Erhitzungen werden dabei meist mit Hilfe fiberoptischer Thermometer an verschiedenen Positionen im Gel gemessen. Eine Alternative ist die Aufnahme einer globalen Karte der Temperaturerhöhung mit Hilfe der MR-Thermometrie. In dieser Arbeit wird eine Messmethode vorgestellt, die MR-Thermometrie mit HF induziertem Heizen kombiniert. Diese Methode wurde an einem Kupferdraht im Gelphantom validiert und mit fiberoptisch gemessenen Temperaturanstiegen verglichen. KW - Kernspintomografie KW - Messprozess KW - Relaxometrie KW - Thermometrie KW - nicht-kartesische Bildgebung KW - Relaxometry KW - Thermometry KW - non-Cartesian imaging KW - Optimierung KW - MRI KW - NMR-Tomographie Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-72531 ER - TY - THES A1 - Metzger, Christian Thomas Peter T1 - Development of photoemission spectroscopy techniques for the determination of the electronic and geometric structure of organic adsorbates T1 - Entwicklung von Photoemissionsmethoden zur Bestimmung der elektronischen und geometrischen Struktur von organischen Adsorbaten N2 - The projects presented in this thesis cover the examination of the electronic and structural properties of organic thin films at noble metal-organic interfaces. Angle-resolved photoemission spectroscopy is used as the primary investigative tool due to the connection of the emitted photoelectrons to the electronic structure of the sample. The surveyed materials are of relevance for fundamental research and practical applications on their own, but also serve as archetypes for the photoemission techniques presented throughout the four main chapters of this thesis. The techniques are therefore outlined with their adaptation to other systems in mind and a special focus on the proper description of the final state. The most basic description of the final state that is still adequate for the evaluation of photoemission data is a plane wave. Its simplicity enables a relatively intuitive interpretation of photoemission data, since the initial and final state are related to one another by a Fourier transform and a geometric factor in this approximation. Moreover, the initial states of some systems can be reconstructed in three dimensions by combining photoemission measurements at various excitation energies. This reconstruction can even be carried out solely based on experimental data by using suitable iterative algorithms. Since the approximation of the final state in the photoemission process by a plane wave is not valid in all instances, knowledge on the limitations of its applicability is indispensable. This can be gained by a comparison to experimental data as well as calculations with a more detailed description of the photoemission final state. One possible appraoch is based on independently emitting atoms where the coherent superposition of partial, atomic final states produces the total final state. This approach can also be used for more intricate studies on organic thin films. To this end, experimental data can be related to theoretical calculations to gain extensive insights into the structural and electronic properties of molecules in organic thin films. N2 - Die in dieser Arbeit vorgestellten Projekte behandeln die Untersuchung der elektronischen und strukturellen Eigenschaften organischer Dünnschichtfilme an Grenzflächen zwischen Edelmetallen und organischen Materialien. Als maßgebliche Messmethode wird die winkelaufgelöste Photoelektronenspektroskopie aufgrund der Verbindung der emittierten Photoelektronen mit der elektronischen Struktur der untersuchten Probe angewandt. Die verwendeten Materialien sind sowohl in der Grundlagenforschung als auch für praktische Anwendungen relevant, und dienen gleichzeitig auch als Beispiele für die Photoemissionstechniken, die in den vier Hauptkapiteln der Arbeit präsentiert werden. Diese Techniken werden daher auch bezüglich ihrer Ubertragbarkeit auf andere Systeme dargestellt, wobei besonders auf die korrekte Beschreibung des Endzustands in der Photoemission eingegangen wird. Die simpelste Beschreibung des Endzustands, die für die Auswertung von Photoemissionsdaten noch sinnvoll verwendet werden kann, stellt eine ebene Welle dar. Ihre Einfachheit ermöglicht eine relativ intuitive Interpretation von Photoemissionsdaten, da Anfangs- und Endzustand in dieser Näherung lediglich durch eine Fourier-Transformation und einen geometrischen Faktor verknüpft sind. Kombiniert man die Photoemissionsmessungen bei unterschiedlichen Anregungsenergien, lassen sich zusätzlich die Anfangszustände bestimmter Systeme in guter Näherung dreidimensional rekonstruieren. Mit Hilfe geeigneter iterativer Algorithmen ist diese Rekonstruktion darüber hinaus mit ausschließlich experimentellen Daten realisierbar. Da die Näherung des Endzustands mit einer ebenen Welle nur unter bestimmten Bedingungen ausreichend präzise das reale System widerspiegelt, ist die Kenntnis über die Grenzen ihrer Anwendbarkeit von Bedeutung. Dies kann über den Vergleich mit experimentellen Daten sowie Rechnungen mit detailierteren Beschreibungen des Endzustands in der Photoemission geschehen. Ein möglicher Ansatz basiert auf unabhängig voneinander emittierenden Atomen, deren kohärent überlagerte, partielle Endzustände den gesamten Endzustand formen. Dieser Ansatz kann des Weiteren für komplexere Untersuchungen an organischen Dünnschichten verwendet werden. So können über den Vergleich von experimentellen Messung mit theoretischen Rechnungen umfangreiche Einblicke auf die strukturellen und elektronischen Eigenschaften der Moleküle in organischen Dünnschichten gewonnen werden. KW - ARPES KW - Molekülphysik KW - Organisches Molekül KW - Photoelektronenspektroskopie KW - LEED KW - Angle-resolved Photoemission Spectroscopy KW - Winkelaufgelöste Photoemissionspektroskopie KW - Molecular Physics KW - Molekülphysik Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-229525 ER - TY - THES A1 - Greiser, Andreas T1 - Dichte-gewichtete Phasenkodierung zur effizienten k-Raumabtastung in der NMR-Bildgebung T1 - Density-weighted phase-encoding for efficient k-space sampling in NMR Imaging N2 - Die spektroskopische NMR-Bildgebung (Chemical Shift Imaging, CSI) kombiniert die Lokalisationstechniken der NMR-Tomographie mit der NMR-Spektroskopie und bietet so eine ortsaufgelöste metabolische Information über das untersuchte Gewebe. Mit dieser Technik können Stoffwechselvorgänge direkt und quantitativ untersucht werden. Deshalb finden die Verfahren der spektroskopischen NMR-Bildgebung in der medizinischen Forschung eine immer breitere Anwendung. Zwei Aspekte erschweren hierbei die klinische Etablierung dieser Methoden: die aufgrund der geringen Empfindlichkeit langen notwendigen Messzeiten bei dennoch geringer räumlicher Auflösung und die im Vergleich zur herkömmlichen NMR-Tomographie aufwendigere Datenauswertung. In der vorliegenden Arbeit wurden in beiden Punkten substantielle methodische Fortschritte erzielt. In einer Fallstudie mit Herzpatienten konnten erstmals die Veränderungen der Metabolitensignale auf 31P-Karten visualisiert werden. Die dabei erreichte Empfindlichkeit erlaubt auch die Untersuchung der Herzhinterwand, wobei hier die Sensitivität an der Grenze des für eine Individualdiagnostik minimal akzeptablen Signal-Rausch-Verhältnisses (SNR) liegt. Der Einsatz höherer Grundfeldstärken in der 31P-NMR-Spektroskopie läßt einen deutlichen Empfindlichkeitsgewinn erwarten. Im Rahmen dieser Arbeit wurde eine umfassende Vergleichsstudie zwischen einem klinischen 1,5 T NMR-Bildgebungssystem und einem 2,0 T Tomographen durchgeführt. Der beobachtete Empfindlichkeitsgewinn von 45% steht im Rahmen der Messgenauigkeit in Einklang mit einem theoretisch zu erwartenden, linearen Anstieg des SNR. Die Lokalisationseigenschaften eines ortsaufgelösten NMR-Experiments werden dadurch bestimmt, wie die der k-Raum, der Raum der räumlichen Frequenzen, abgetastet wird. Insbesondere in räumlich niedrig aufgelösten Experimenten führen die Seitenbanden der räumlichen Antwortfunktion zu Signalkontamination. Bei der Phasenkodierung kann diese Kontamination durch eine auf unterschiedlichen Mittelungszahlen beruhende Wichtung der k-Raumabtastung unterdrückt werden. Bei vorgegebener Experimentdauer und räumlicher Auflösung verringert diese Akkumulations-gewichtetete Phasenkodierung jedoch im Vergleich zum ungewichteten Experiment den abdeckbaren Bildbereich. Der Schwerpunkt der vorliegenden Arbeit lag deshalb auf der Entwicklung eines neuen k-Raum-Abtastschemas. Dieses Abtastschema basiert auf einer Modulation der Abtastdichte im k-Raum und wird deshalb als Dichte-Wichtung („DW“) bezeichnet. Zur Diskretisierung einer gewünschten kontinuierlichen Wichtungsfunktion dient ein neuer, nicht-iterativer Algorithmus, der aus den Eingangsparametern räumliche Auflösung und Gesamt-Akkumulationszahl ein geeignetes Abtastschema generiert. Die Lokalisations-Eigenschaften der Dichte-Wichtung wurden ausführlich analysiert und mit den etablierten Phasenkodierschemata verglichen. Die Dichte-gewichtete k-Raumabtastung kombiniert die Vorteile der Akquisitions-gewichteten Phasenkodierung mit einem maximierten Bildbereich. So kann bei kürzeren Experimentdauern ein deutlicher Gewinn an Lokalisationsqualität erzielt werden, ohne dabei die Vorteile einer reinen Phasenkodierung aufzugeben. Für die Dichte-gewichtete Phasenkodierung gibt es ein weites Anwendungsfeld. Sie wurde im Rahmen dieser Arbeit in mehreren vorklinischen Studien erfolgreich eingesetzt. Die theoretisch zu erwartenden Vorteile bezüglich der Lokalisationseigenschaften bestätigten sich experimentell. Im Bereich der spektroskopischen 31P-NMR-Bildgebung in vivo erwies sich die Dichte-Wichtung als deutlich bessere Alternative zur Akkumulations-Wichtung. Die Einfaltungen des starken Brustmuskelsignals, welche im bisher verwendeten 31P CSI Protokoll den Informationsgehalt der Metabolitenkarten beeinträchtigt hatten, konnten unterdrückt werden. In der 23Na-NMR-Bildgebung am Herzen wurde das DW Abtastschema eingesetzt, um die Verbesserung der Lokalisationsqualität durch Akquisitions-Wichtung erstmals auch in der 23Na-NMR-Bildgebung am menschlichen Herzen zu nutzen. Es konnte gezeigt werden, daß die DW Methode deutliche Vorteile im Vergleich zu den herkömmlichen Abtastungen liefert. Mit der DW Methode gelang es, 23Na-Bilder des menschlichen Herzens von bisher unerreichter Qualität zu erzeugen. Insgesamt wurde mit der Dichte-gewichteten k-Raumabtastung in der vorliegenden Arbeit eine flexible und effiziente Art der Akquisitionswichtung entwickelt. Zusätzlich zu einer deutlichen Verbesserung der Lokalisationsqualität bei optimaler Empfindlichkeit wird mit DW auch die Optimierung des abdeckbaren Bildbereichs erreicht. Somit bietet DW im Vergleich zum Akkumulations-gewichteten Experiment eine größere Flexibilität bei der Wahl der experimentellen Parameter Auflösung und Experimentdauer. Darüber hinaus ist das DW Abtastschema potentiell für jedes NMR-Bildgebungsexperiment mit niedriger räumlicher Auflösung von Nutzen. N2 - Magnetic Resonance Spectroscopic imaging (Chemical Shift Imaging, CSI) combines the localization techniques of MRI with MR spectroscopy and therefore povides spatially resolved metabolic information of the investigated tissue. Two aspects hamper the clinical acceptance of this method: the long measurement durations and the more elaborate data evaluation. In the presented work in both aspects significant improvements were achieved. In a case study with patients after myocardial infarction the changes in the 31P metabolite levels could be visualized. In combination with an automated data evaluation the acceptance of spectroscopic 31P MRI will be improved. Higher field strengths can improve the sensitivity in MRI. In an extended volunteer study a gain of 45% in sensitivity could be achieved at a field strength of 2.0 T compared to the clinically established 1.5 T. The localization properties in a spatially resolved NMR experiment are determined by the way how the k-space, representing the spatial frequencies that are acquired, is sampled. In particular in experiments with low spatial resolution, the sidebands of the spatial response function result in severe signal contamination. In phase-encoded expeiments this contamination can be suppressed by variable accumulation numbers at different positions in k-space. However, this results in a reduced spatial coverage in image space. The main goal of this work was the implementation of a new k-pace sampling scheme, that is based on the variation of the sampling density and is therefore referred to as "Density-weighting". To generate the discrete sampling matrix a new, non-iterative algorithm was developed, that calculates the sampling scheme from the input parameters spatial resolution and total number of accumulations. The new ampling scheme was extensively analyzed and compard to the established schemes. Density-weighting combines the advantages of Accumulation-weighting with a maximized field of view. At shorter experiment durations and maintained optimal sensitivity a significant improvement in image quality could be achieved. In several applications of cardiac spectroscopic MR imaging the advantages could be demonstrated. KW - Herzfunktionsdiagnostik KW - Phosphor-31-NMR-Spektroskopie KW - Chemische Verschiebung KW - Phasen-Kodierung KW - Dichte-Wichtung KW - Akquisitions-Wichtung KW - NMR-Bildgebung KW - Phase-encoding KW - Density-weighting KW - Acquisition-weighting KW - NMR-Imaging Y1 - 2003 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-7145 ER - TY - THES A1 - Fidler, Florian T1 - Die Durchblutung des menschlichen Herzmuskels : quantitative Bestimmung in vivo mittels Kernspintomographie T1 - The perfusion of the human heart: Quantitative Assessment in vivo using magnetic resonance tomography N2 - Die Aufgabenstellung dieser Arbeit bestand in der Entwicklung und Umsetzung von Verfahren, mit denen die Durchblutung des menschlichen Herzmuskels quantitativ bestimmt werden kann. Im Rahmen dieser Arbeit wurden dazu zwei Ansätze verfolgt, das kontrastmittelfreie Spin-Labeling Verfahren und die kontrastmittelgestützte First-Pass Messung N2 - The goal of this dissertation was the developement and implementation of methods to quantify the microcirculation of the human heart. To this end, two approaches were investigated, a contrast agent free spin-labeling technique, and a contrast agent based First-Pass technique. KW - Herzmuskel KW - Durchblutungsmessung KW - NMR-Tomographie KW - Durchblutung KW - MRT KW - Herz KW - perfusion KW - MRI KW - heart Y1 - 2004 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-12784 ER - TY - THES A1 - Treisch, Florian T1 - Die Entwicklung der Professionellen Unterrichtswahrnehmung im Lehr-Lern-Labor Seminar T1 - Assessing the professional vision of pre-service teachers in the Student-Lab N2 - Der Übergang vom der ersten Phase der Lehramtsausbildung ins Referendariat wird häufig mit dem Begriff „Praxisschock“ verbunden. Viele Studierende und Referendare fühlen sich unzureichend auf den Unterricht in der Schule vorbereitet. Sie fordern deshalb eine stärkere Verzahnung von Theorie und Praxis, also eine Anwendung der erlernten Theorien in „echten“ Praxisphasen auch schon in der ersten Phase der Lehramtsausbildung. Das Lehr-Lern-Labor Seminar der Universität Würzburg kann dazu beitragen, diese Verbindung von Theorie und Praxis herzustellen. Grundlegend sollen die Studierenden in diesem Seminar ihr fachliches, didaktisches und pädagogisches (Vor-)Wissen aufgreifen und in komplexitätsreduzierten Handlungsumgebungen anwenden. Dabei sollen sie im Rahmen des Lehr-Lern-Labor Seminars zunächst Experimentierstationen zu vorgegebenen Themengebieten aus dem bayerischen Lehrplan konzipieren, um anschließend mehrmals Schülerinnen und Schüler an diesen Stationen zu betreuen. Im Sinne einer iterativen Praxis werden die Betreuungen mehrmals von den Studierenden zusammen mit zwei Dozenten reflektiert. Letztlich wiederholen sich die Betreuungen, die Reflexionsphasen und mögliche Verbesserungen der Stationen viermal in einem zyklischen Prozess. Für die Verknüpfung von theoretischem Wissen in konkreten Handlungssituationen sind Wahrnehmungsprozesse von Bedeutung. Die sogenannte Professionelle Unterrichts-wahrnehmung beschreibt die Fähigkeit, relevante Unterrichtssituationen zu erkennen und theoriebezogen zu bewerten. Sie verknüpft das zugrunde liegende Wissen mit konkreten Handlungssituationen und dient somit als Bindeglied zwischen dem Wissen und dem Handeln, welches speziell in Reflexionsphasen gefördert werden kann. Durch die mehrmaligen Reflexionsprozesse der eigenen Betreuungen und die der Kommilitonen im Lehr-Lern-Labor Seminar könnte es eine vielversprechende Grundlage zur Förderung der Professionellen Unterrichtswahrnehmung darstellen. Die grundlegende Fragestellung der vorliegenden Arbeit ist es daher zu untersuchen, ob sich die Professionelle Unterrichtswahrnehmung im Rahmen des Lehr-Lern-Labor Seminars fördern lässt und inwieweit neu integrierte Videoanalysen der eigenen Betreuungen und die der Kommilitonen die Professionelle Unterrichtswahrnehmung der Studierenden zusätzlich fördern. Weiterhin interessiert, ob personenspezifische Merkmale einen zusätzlichen Einfluss auf die Entwicklung der Professionellen Unterrichtswahrnehmung ausüben. Ergänzend wird untersucht, ob zwischen dem Fachwissen, dem didaktischen Wissen und der Professionellen Unterrichtswahrnehmung Zusammenhänge bestehen. Dies könnte Aufschluss darauf geben, inwieweit Fachwissen und didaktisches Wissen die Entwicklung der Professionellen Unterrichtswahrnehmung im Seminar bedingen. Diese Arbeit leistet somit einen wichtigen Beitrag zur Untersuchung der Wirksamkeit eines Lehr-Lern-Labor Seminars, welches in die Ausbildung von Physiklehrkräften integriert wurde und zeigt auf, wie das Seminar bezüglich der Förderung der Professionellen Unterrichtswahrnehmung effektiver gestaltet werden kann. N2 - The transition from the first phase of the teacher education at the university to the two-year teacher training at school is often associated with the term “reality shock”. Many pre-service and in-service teachers feel inadequately prepared for teaching in schools. Therefore, there is an increasing call for a stronger connection of theory and practice. More precisely, pre-service teachers and educators demand an application of the theoretical knowledge in real practice situations already during education at the university. The Student-Lab seminar at the University of Würzburg can contribute to the connection of theory and practice. In this seminar, the participating pre-service teachers should use their content, didactical and pedagogical knowledge to create experimental stations for students on a given topic based on the Bavarian curriculum. Following, the pre-service teachers teach students on microteaching settings at the experimental stations. After every run, the pre-service teachers will reflect their teaching peer to peer and with the instructors. According to an iterative practice, there is an ongoing change of practice, reflection and improvement of the stations and the teaching. The connection of theory and practice is strongly related to professional vision. Professional vision describes the ability of a teacher to notice relevant teaching situations and to provide proper reasoning based on theoretical background. It links theoretical knowledge to specific teaching situations and serves as a connection between dispositions and performance, which can be learned during reflection. Due to the iterative reflections of their own teaching and the teaching of fellow students, the Student-Lab seminar could be a promising learning environment for the development of pre-service teachers’ professional vision. Therefore, the fundamental research questions are as follows: Is it possible to foster the pre-service teachers’ professional vision in the Student-Lab seminar? Furthermore, is there an additional effect due to newly integrated video analysis of their own and their fellows’ teaching in the Student-Lab? There is also an interest in the influence of individual characteristics on the development of professional vision. Another interest concerns the relation between the pre-service teachers’ content knowledge, didactical knowledge and their professional vision. This provides a hint to what extent the content knowledge and the didactical knowledge determine the development of professional vision. This work provides an important contribution to the investigation of the effectiveness of a Student-Lab integrated in the education of physics teachers. It gives indications for the organization and the learning contents of a Student-Lab seminar. KW - Lehramtsstudium KW - Lehr-Lern-Forschung KW - Schülerversuch KW - Lehr-Lern-Labor KW - Student-Lab KW - Professionelle Unterrichtswahrnehmung KW - professional vision KW - Videoanalyse KW - video analysis KW - Lehramt KW - Lehranalyse Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-164170 ER - TY - THES A1 - Stichel, Thomas Günther T1 - Die Herstellung von Scaffolds aus funktionellen Hybridpolymeren für die regenerative Medizin mittels Zwei-Photonen-Polymerisation T1 - Fabrication of scaffolds of hybrid polymers for regenerative medicine using two photon polymerization N2 - In der vorliegenden Arbeit wurde das Verfahren der Zwei-Photonen-Polymerisation von anorganisch-organischen Hybridpolymeren (ORMOCER®e) untersucht. Untersuchungsschwerpunkte bildeten dabei die theoretischen Betrachtungen der Wechselwirkung zwischen Laser und Hybridpolymer, die experimentelle Charakterisierung unterschiedlicher ORMOCER®e sowie die Aufskalierung der Technologie im Hinblick auf die Herstellung von Scaffold-Strukturen für die regenerative Medizin. Hierbei wurde u. a. ein innovativer Belichtungsaufbau entworfen und aufgebaut, der es erlaubt makroskopische, poröse Scaffold-Strukturen mit minimalen Strukturgrößen im Bereich von wenigen Mikrometern herzustellen. ORMOCER®e sind typischerweise für optische Anwendungen konzipiert, weisen allerdings z. T. biokompatible Eigenschaften auf. Das Material ORMOCER® MB-47 wurde von M. Beyer eigens für biologische Anwendungen synthetisiert. Es zeichnet sich durch Biokompatibilität, teilweiser Biodegradierbarkeit und hervorragende Strukturierbarkeit durch die Zwei-Photonen-Polymerisation aus. Das in dieser Arbeit verwendete Mikrostrukturierungssystem beinhaltet im Wesentlichen einen Ultrakurzpulslaser, der 325 fs Pulse bei 1030 nm emittiert (verwendet wird die zweite Harmonische bei 515 nm), ein hochpräzises Positionierungssystem, bestehend aus drei luftgelagerten Lineartischen mit einer Reichweite von 10 cm (y-, z-Richtung) bzw. 15 cm (x-Richtung) sowie diversen Objektiven zur Fokussierung. Mit diesen Komponenten lassen sich komplexe dreidimensionale Strukturen mit minimalen Strukturgrößen von bis unter 100 nm erzeugen. In Kapitel 5.1 wurden theoretische Untersuchungen im Hinblick auf das Wechselwirkungsverhalten zwischen der fokalen Intensitätsverteilung und dem Materialsystem zur Bildung eines Voxels durchgeführt, wobei das technische Wechselwirkungsvolumen und das chemische Wechselwirkungsvolumen samt den reaktionskinetischen Abläufen separat betrachtet wurde. Das technische Wechselwirkungsvolumen beschreibt die Wechselwirkung zwischen der fokalen Intensitätsverteilung und dem Materialsystem im Rahmen eines Schwellwertprozesses, der es erlaubt Strukturdimensionen unterhalb des Beugungslimits zu realisieren. Die theoretischen Untersuchungen diesbezüglich ergaben, dass sphärische Aberrationen die fokale Intensitätsverteilung (Intensity-Point Spread Function (IPSF)) in Abhängigkeit der Belichtungskonfiguration z. T. sehr stark beeinflussen. Darüber hinaus wurde durch Betrachtung des Schwellwertverhaltens ein mathematischer Zusammenhang zwischen der IPSF und der Leistungsabhängigkeit der Charakteristik des technischen Wechselwirkungsvolumens geschaffen. Das chemische Wechselwirkungsvolumen beschreibt das tatsächliche Volumen der stattfindenden Polymerisationsreaktion. Dieses geht über das des technischen hinaus, was eine Folge von raumeinnehmendem Kettenwachstum im Rahmen von reaktionskinetischen Teilprozessen ist. Durch die Simulationen dieser reaktionskinetischen Abläufe wurde das leistungsabhängige, zeitliche Verhalten der Reaktionsteilnehmer (Radikale, Monomer, Photoinitiator) und des Vernetzungsgrades ermittelt. Die Simulation wurden für sehr kurze Belichtungszeiten (< 10 ms) auf der Basis von gekoppelten Differentialgleichungen nach Uppal & Shiakolas durchgeführt. Dabei wurde der Einfluss der Teilchendiffusion sowie der Temperaturentwicklung als gering erachtet und in den Berechnungen vernachlässigt. Die Simulationsergebnisse zeigen, dass eine geringe Belichtungszeit nicht unbedingt durch größere Laserleistungen ausgeglichen werden kann, um einen bestimmten Vernetzungsgrad zu erzielen. Vielmehr führt eine höhere Leistung zu einem raschen Verbrauch des Photoinitiators im Reaktionsvolumen und damit einem schnelleren Erliegen der Polymerisationsreaktion. Um dennoch hohe Vernetzungsgrade erzielen zu können, sind die Reaktionsgeschwindigkeitskoeffizienten der Propagation und der Terminierung k_P und k_T sowie eine ausreichende Photoinitiatorkonzentration von entscheidender Bedeutung. Je größer das Verhältnis k_P/k_T, desto höhere Vernetzungsgrade können auch bei kurzen Belichtungszeiten realisiert werden, wobei ein wesentlicher Teil der Polymerisation als Dunkelreaktion stattfindet. Diese Erkenntnis ist für die Aufskalierung der Technologie der Zwei-Photonen-Polymerisation von großer Bedeutung, welche mit einer Verkürzung der Belichtungszeiten einhergehen muss. Des Weiteren zeigen die Simulationen, dass das spatiale Konversionsprofil eines Voxels ein lokales Minimum im Zentrum aufweisen kann. Dieses Phänomen tritt dann auf, wenn aufgrund der applizierten Leistung, welche gemäß des Profils der IPSF im Zentrum am höchsten ist, der Photoinitiator im Zentrum rasch verbraucht wird. In Kapitel 5.2 wurde die Voxelbildung, das Vernetzungsverhalten sowie die mechanischen Eigenschaften belichteter ORMOCER®e bei unterschiedlichen Parametern und Materialsystemen experimentell untersucht. An Hand von Voxelfeldern wurden die Voxelgröße, das Aspektverhältnis und das Voxelvolumen bei unterschiedlichen Laserleistungen ermittelt. Die Ergebnisse wurden mit den berechneten technischen Wechselwirkungsvolumina verglichen, wobei die Differenz von tatsächlicher Voxelgröße und technischem Wechselwirkungsvolumen als eine weitere charakteristische Größe eingeführt wurde. Dabei zeigte sich, dass besonders die Voxellänge von der Länge des technischen Wechselwirkungsvolumens derart abweicht, dass dies nicht durch raumeinnehmendes Kettenwachstum im Rahmen der Reaktionskinetik erklärt werden kann. Mögliche Erklärungsansätze basieren hierbei auf Wechselwirkungseffekte zwischen Lichtfeld und Material. Beispielsweise könnten durch den nichtlinearen optischen Kerr-Effekt oder die Polymerisation selbst Brechzahlinhomogenitäten induziert werden, welche die Voxelbildung durch Selbstfokussierung beeinflussen. Der Unterschied der Voxelbreite, also das laterale chemische Voxelwachstum, zur Breite des technischen Wechselwirkungsvolumens wurde hingegen mit Hilfe der Reaktionskinetik erklärt. Dabei zeigte sich, dass dieser Unterschied sowohl vom Material selbst als auch von der Fokussieroptik abhängt. Des Weiteren wurde die Polymerisationsrate der unterschiedlichen Materialien aus der Auftragung des Voxelvolumens gegenüber der Laserleistung durch lineare Approximation bestimmt. Hierbei wurde festgestellt, dass die Materialsysteme z. T. erhebliche Unterschiede aufweisen. Als das Materialsystem mit der höchsten Polymerisationsrate hat sich das auf Acrylaten als vernetzbare Gruppen basierende OC-V in Kombination mit dem Irgacure® Oxe02 Photoinitiator herausgestellt. Aus diesem Grund wurde es für die Herstellung von makroskopischen Strukturen durch die Zwei-Photonen-Polymerisation bevorzugt verwendet. Die unterschiedlichen Materialien wurden ferner mit Hilfe der µ-Raman-Spektroskopie auf ihr Vernetzungsverhalten untersucht. Konkret wurden hierbei Linienfelder unter Variation der Scan-Geschwindigkeit und der Laserleistung mit Hilfe der 2PP hergestellt und vermessen. Die Vernetzungsgrade wurden semi-quantitativ aus den Spektren ermittelt. Insgesamt wurden Vernetzungsgrade im Bereich zwischen 40 % und 60 % gemessen, wobei mit OC-V und 2 Gew.-% Irgacure® Ox02 die höchsten Vernetzungsgrade erzielt wurden. Des Weiteren hat sich gezeigt, dass die Konversionsgrade für die jeweiligen Materialsysteme bei allen Scan-Geschwindigkeiten sich auf einem im Rahmen der Fehlergrenzen gleichem Niveau befinden. Damit kann der durch Simulationen theoretisch prognostizierte Abfall des Sättigungskonversionsgrades mit zunehmender Scan-Geschwindigkeit mit entsprechend variierenden Belichtungszeiten nicht als verifiziert angesehen werden. Die verschiedenen Materialsysteme wurden außerdem bezüglich ihrer mechanischen Eigenschaften charakterisiert. Zu diesem Zweck wurden zylindrische Formkörper unter verschiedenen Bedingungen (1PP, 2PP, verschiedene Photoinitiatorkonzentrationen) hergestellt und Druckfestigkeitsmessungen durchgeführt, sowie die Dichten und die Vernetzungsgrade aus den Formkörpern bestimmt. Insgesamt wurden Elastizitätsmodule im Bereich zwischen 0,40 und 1,37 GPa und Bruchfestigkeitswerte zwischen 117 bis 310 MPa ermittelt. Es konnte festgestellt werden, dass die Konzentration des Photoiniators das Vernetzungsverhalten und damit die mechanischen Eigenschaften der Formkörper stark beeinflusst. Während geringe Konzentrationen zu geringeren Vernetzungsgraden und niedrigen Elastizitätsmodulen führten, zeigten die Formkörper höherer Konzentration ein deutlich spröderes Verhalten mit höheren Vernetzungsgraden und Elastizitätsmodulen. Das höchste Elastizitätsmodul wurde an Hand von Formkörpern vermessen, welche aus OC-V mit 2 Gew.-% Irgacure® Ox02 hergestellt wurden. Darüber hinaus wurde festgestellt, dass sich die mechanischen Eigenschaften von durch 2PP hergestellten Formkörpern durch die applizierte Laserleistung beeinflussen lassen. Die Ursache hierfür ist, dass durch die Laserleistung die Voxelgröße und damit der Überlapp zwischen den Voxeln eingestellt werden kann. Im Bereich des Überlapps findet dann eine Doppelbelichtung des Materials statt, was zu höheren Vernetzungsgraden führen kann. Außerdem wurden durch die 2PP bei hinreichend großen Belichtungsleistungen auch Formkörper realisiert, welche höhere Elastizitätsmodule und Bruchfestigkeitswerte aufwiesen als Körper, welche durch UV-Belichtung hergestellt wurden. Die Aufskalierung der Zwei-Photonen-Technologie wurde in Kapitel 5.3 behandelt. Neben einer ausführlichen Diskussion zu den Herausforderungen diesbezüglich, wurden zwei Belichtungsstrategien zur Herstellung von makroskopischen Scaffold-Strukturen eingesetzt und optimiert. Hierbei ist insbesondere der Badaufbau hervorzuheben, der es erlaubte Strukturen von prinzipiell unbegrenzter Höhe mit Hilfe der Zwei-Photonen-Polymerisation herzustellen. Eine wesentliche Herausforderung der Aufskalierung der 2PP ist die Beschleunigung des Prozesses. Aus den Betrachtungen geht hervor, dass für eine gravierende Beschleunigung der 2PP-Strukturierung neben der Scan-Geschwindigkeit auch das Beschleunigungsvermögen des Positionierungssystems entscheidend ist. Des Weiteren sind auch Parallelisierungsmethoden mit z. B. diffraktiven optischen Elementen nötig, um ausreichende Prozessgeschwindigkeiten zu erzielen. Der Standardaufbau mit Luftobjektiven wurde dazu verwendet millimetergroße Strukturen mit hoher Qualität aus ORMOCER®en herzustellen. Auch wenn die maximale Strukturhöhe durch den Arbeitsabstand des Objektivs beschränkt ist, hat sich gezeigt, dass dieser Aufbau sich für die einfache Herstellung von millimetergroßen Test-Scaffold-Strukturen eignet, welche z. B. für Zellwachstumsversuche oder mechanische Belastungstest eingesetzt werden können. Das biodegradierbare MB-47 wurde hierbei ebenfalls erfolgreich eingesetzt und u. a. für die Herstellung von Drug-Delivery-Strukturen verwendet. Der Badaufbau, basierend auf einem Materialbad mit durchsichtigem Boden, einem darin befindlichen und in der Vertikalen (z-Richtung) beweglichen Substrathalter sowie einer Belichtung von unten durch eine sich in der Ebene bewegende Fokussieroptik, wurde verwendet um eine Freiheitsstatue mit 2 cm Höhe sowie millimetergroße Scaffold-Strukturen mit Porengrößen im Bereich von 40 bis 500 µm in ORMOCER-V zu realisieren. Weitere Strukturierungsresultate mit z. T. anwendungsbezogenem Hintergrund sind die Gehörknöchelchen des menschlichen Ohrs in Lebensgröße, ein Scaffold in Form eines Steigbügels des menschlichen Ohrs, Test-Scaffold-Strukturen für mechanische oder biologische Untersuchungen sowie Drug-Delivery Strukturen. Es wurden Bauraten von bis zu 10 mm^3/h erzielt. Bezüglich der Prozessgeschwindigkeit und Strukturhöhe wurde bei Weitem noch nicht das Potential des luftgelagerten Positioniersystems ausgeschöpft. Dafür bedarf es einer Gewichtsoptimierung des bestehenden Belichtungsaufbau, um höhere Beschleunigungswerte und Scan-Geschwindigkeiten realisieren zu können. Unter Annahme einer effektiven Gewichtsoptimierung und der damit verbundenen Erhöhung der Beschleunigung auf 10 m/s^2 könnte eine Baurate bei einer Scan-Geschwindigkeit von 225 mm/s und einem Slice- und Hatch-Abstand von 15 und 10 µm von etwa 60 mm^3/h erzielt werden. Im Rahmen der Aufskalierung wurde ebenfalls der experimentelle Einsatz von diffraktiven optischen Elementen zur Fokus-Multiplikation untersucht. Die Experimente wurden mit Hilfe eines Elements durchgeführt, welches eine 2 x 2 Punkte-Matrix neben der ungebeugten 0. Ordnung bereitstellt und Bestandteil eines experimentellen Setups war, welches aus Linsen, Blenden und einem Objektiv zur Fokussierung bestand. Mit Hilfe der erzeugten Spot-Matrix wurden zum einen simultan vier Drug-Delivery-Strukturen hergestellt und zum anderen einzelne Scaffold-Strukturen realisiert. In jedem Fall wurde eine Beschleunigung des Prozess bzw. eine Erhöhung der Polymerisationsrate um den Faktor 4 für die verwendeten Parameter erreicht. Bei der Herstellung der Scaffolds wurden zwei unterschiedliche Strategien verfolgt. Während zum einen die Periodizität der inneren Scaffold-Struktur auf die Fokusabstände angepasst und damit simultan vier aneinandergereihte Einheitszellen hergestellt wurden, konnte zum anderen auch demonstriert werden, dass durch die geschickte Bewegung der Fokusse eine ineinander verschobene Struktur möglich ist. Der Vorteil der letzteren Strategie ist, dass auf diese Weise eine komplette Schicht gescannt werden kann und damit hohe Scan-Geschwindigkeiten realisiert werden können. Die erzielten Bauraten waren dennoch nicht größer als die Bauraten, die mit einem einzelnen Spot im Rahmen des Standardaufbaus oder des Badaufbaus erreicht wurden. Hierfür bedarf es weiterer Optimierung der Parameter und des Setups. Transmittiert fokussiertes Licht eine Grenzfläche zweier Medien mit unterschiedlichen Brechungsindizes, dann tritt sphärische Aberration auf, welche sich durch die Verbreiterung des Fokus besonders in axiale Richtung bemerkbar macht. Da diese im Rahmen der verwendeten Belichtungsstrategien die Strukturierungsergebnisse nachweislich beeinträchtigen, wurden experimentelle Untersuchungen sowie Optimierungsroutinen diesbezüglich durchgeführt. Im Zusammenhang mit dem Standardaufbau wurde eine Leistungsanpassung während der Strukturierung vorgenommen. Auf diese Weise wurde erreicht, dass bei variabler Fokustiefe im Material die maximale Intensität trotz sphärischer Aberration konstant gehalten wurde, wodurch sich die strukturelle Homogenität der Scaffolds entlang der axialen Richtung (optische Achse) deutlich verbesserte. Des Weiteren wurde der Badaufbau dazu verwendet, die axiale Intensitätsverteilung in-situ für diskrete Fokustiefen unter der Verwendung eines Objektivs mit der NA von 0,60 abzubilden. Zu diesem Zweck wurde aus hergestellten Voxelfeldern eine Voxelfeldfunktion ermittelt und mit der axialen IPSF korreliert. Dabei wurde angenommen, dass sich das chemische Wechselwirkungsvolumen vernachlässigbar gering vom technischen Wechselwirkungsvolumen unterscheidet. Die experimentellen Ergebnisse zeigten deutlich die für sphärische Aberrationen typischen Nebenmaxima auf. Die Lage bzw. Abstände dieser entsprachen in guter Übereinstimmung den jeweiligen Simulationen. Schließlich wurde noch die sphärische Aberration durch den Korrekturring der Objektive für verschiedene Deckglasdicken korrigiert. Die resultierende IPSF wurde ebenfalls mit Hilfe des Badaufbaus abgebildet, wobei keinerlei Nebenmaxima gefunden werden konnten. Die Breite des Hauptmaximums konnte deutlich verringert werden. Zusammengefasst lässt sich sagen, dass im Rahmen dieser Arbeit erhebliche Fortschritte bei der Aufskalierung der 2PP zur Erzeugung von Scaffold-Strukturen für die regenerative Medizin erzielt wurden. Die erreichten Strukturdimensionen und die Bauraten übertreffen alle bis dato bekannten Ergebnisse. Dabei wurden auch durch theoretische Betrachtungen und experimentellen Methoden grundlegende Erkenntnisse über die Reaktionsdynamik der durch die Zwei-Photonen-Absorption initiierten Polymerisationsreaktion gewonnen. Nichtsdestotrotz sind einige Fragestellungen offen sowie Problematiken des Prozesses vorhanden, die für eine Realisierung von makroskopischen Scaffold-Strukturen gelöst werden müssen. So sind die realisierten Bauraten noch zu gering, um in angemessener Zeit makroskopische Scaffolds-Strukturen herzustellen, welche deutlich größer als 1 cm^3 sind. Aus diesem Grund müssen weitere Verbesserungen bezüglich der Scan-Geschwindigkeit sowie des Einsatzes von diffraktiven optischen Elementen zur Erhöhung der Polymerisationsrate erzielt werden. Da bei der Verwendung von Multi-Spot-Arrays, welche mit Hilfe gewöhnlicher diffraktiver optischer Elemente erzeugt wurden, die Realisierung von beliebigen und detaillierten äußeren Scaffold-Formen eingeschränkt ist, empfiehlt es sich den Einsatz von Spatial Light-Modulatoren zu verfolgen. Diese fungieren als dynamisch modulierbares DOE, mit dem einzelne Spots gezielt ein- und ausgeblendet und Spotabstände dynamisch variiert werden können. Schließlich ist es vorstellbar, den Spatial Light-Modulator mit dem Badaufbau zu kombinieren, um uneingeschränkte, große Strukturen in annehmbarer Zeit mit hochaufgelösten Details herstellen zu können. Dieses Vorgehen bedarf allerdings noch der tiefgreifenden Untersuchung der Potentiale des Spatial Light-Modulators. Darüber hinaus weisen die theoretischen und experimentellen Untersuchungen zur Reaktionskinetik darauf hin, dass die Voxelentstehung ein komplexer Prozess ist, der möglicherweise auch durch nichtlineare optische Wechselwirkungseffekte abseits der Zwei-Photonen-Absorption beeinflusst wird. Daher sind hier weitere Untersuchungen und Berechnungen zu empfehlen, um z. B. den Einfluss einer intensitätsabhängigen Brechzahl auf die Voxelbildung quantifizieren zu können. Entsprechende Ergebnisse könnten schließlich dazu dienen, dass im Rahmen dieser Arbeit entwickelte Modell zur Voxelbildung, welches auf der getrennten Betrachtung von technischen und chemischen Wechselwirkungsvolumen basiert, zu verbessern. Ein leistungsfähiges Modell, welches die Voxelbildung in Abhängigkeit des Materials und der Fokussieroptik präzise vorhersagen kann, wäre für das Erzielen optimaler Strukturierungsergebnissen ein Gewinn. N2 - In this thesis, the two photon polymerization technique using ORMOCER®s was investigated thoroughly. The main aspects of matter were the theoretical investigations of the interaction between laser and polymer, the experimental characterization of the different ORMOCER®s, and the scale-up of the photon polymerization technique in order to fabricate scaffolds for the regenerative medicine. The latter was achieved by designing and building up an innovative exposure device[38] which enables the fabrication of scaffold structures with minimal structure sizes of a view microns. The experiments were done using UV sensitive anorganic-organic hybrid polymers, also known as ORMOCER®s. These are typically synthesized for optical applications, but some are also biocompatible. The ORMOCER® MB-47 was invented by M. Beyer for biological application and possesses biocompatibility, partial biodegradability, and advanced 2PP structuring behavior. The micro-structuring system used contains an ultra-short pulse laser which emits 325 fs pulses at 1030 nm (applied was 515 nm using second harmonic generation), a highly precise positioning system which consists of three air-bearing stages with a travel range of 10 cm (y, z direction) and 15 cm (x direction), respectively, and some objectives for focusing. With these components, complex three-dimensional structures with minimal structure size below 1 µm can be produced. In Capital 5.1, theoretical studies of the interaction between the focal intensity distribution and the material, which defines voxel growth, were performed. Therefore, the technical interaction volume and the chemical interaction volume were separately investigated. The technical interaction volume describes the threshold driven interaction between the focal intensity distribution and the material system, which allows the realization of structure sizes below the resolution limit (diffraction) of the wavelength used. The theoretical investigations showed that spherical aberration influences the focal intensity distributions (Intensity-Point Spread Function (IPSF)) which were calculated for different experimental exposure configuration. The results propose a severe influence with increasing focus depth into the material. Moreover, a formal relation between the IPSF and the technical interaction volume was derived by using the threshold assumption. By using the Gaussian beam assumption as IPSF, the analogy of the derived formula to the voxel growth model of Serbin et al. was recognized. The chemical interaction volume represents the actual volume of the polymerization reaction. Its amount exceeds the technical interaction volume due to the space-consuming chain growth during the polymerization. By the simulation of the reaction kinetics of the polymerization, the time- and power-depending behavior of the different reactants (radicals, monomer, photo initiator) as well as the degree of conversion was calculated. The simulations were done for very short exposure times (< 10 ms) by using a system of coupled differential equations which are based on a model invented by Uppal & Shiakolas. Therefore, the influence of diffusion and temperature was estimated to be small on short time scales and thus neglected. The results of the simulations show that a short exposure time cannot be necessarily compensated by high laser powers to achieve a certain degree of conversion. Higher laser power leads rather to a swift consumption of the photo initiator and thus to a disruption of the polymerization. In order to achieve high degrees of conversions, the reactive rate coefficients of the propagation and termination k_P and k_T as well as a sufficient amount of photo initiator concentration is essential. The larger the ratio k_P/k_T the higher degree of conversion can be realized even with short exposure times whereas a significant part of the reaction takes place during the dark period. This finding is important for the scale-up of the photon polymerization technique which has to involve shorter exposure times. Moreover, the simulations show that the spatial profile of the degree of conversion can feature a central minimum. This phenomenon occurs when the central maximum intensity of the IPSF consumes the entire photo initiators in short times which leads to a disruption of the polymerization. In Capital 5.2, the voxel growth, the behavior of conversion as well as the mechanical properties of hardened ORMOCER®s were experimentally investigated with different parameters and material systems. By means of voxel fields, voxel sizes, aspect ratios and voxel volumes at different laser powers were determined. The results were compared with the calculated technical interaction volume, whereas the difference was invented as a new characteristic value. It has been shown that the voxel length deviates clearly from the length of the technical interaction volume which cannot be explained by space-consuming chain growth during the polymerization. Instead, it was assumed that this observation is reasoned by interaction effects between light and material (optical Kerr effect, polymerization) leading to an inhomogeneous refractive index distribution and thus to self-focusing and self-trapping. In contrast to that, the difference between the voxel diameter and the diameter of the technical interaction volume was correlated with reaction kinetic influences. Additionally, the dependency of the voxel volume on the laser power was linear approximated in order to determine the polymerization rate of different material systems. Here, strong differences between the materials were identified. The material with the highest polymerization rate was OC-V with the Irgacure® Oxe02 photo initiator which consists of acrylates as cross-linkable group. Because of this, this material system was preferred for 2PP structuring of large scale structures. The different materials were investigated concerning their conversion behavior by means of µ-Raman spectroscopy. Therefore, fields of lines were produced by 2PP with varying scan speed and laser power and measured. The degree of conversion was then semi-quantitative extracted from the spectra. All in all, the degrees of conversion were determined to be in the range of 40 to 60 % for all materials. The material with the highest degree of conversion was the OC-V with 2 wt.-% Irgacure® Ox02. Moreover, the measurements showed that the degree of conversion for each material system does not vary with the scan speed (exposure time) within the limits of measurement error. Thus, the simulations from Capital 5.1.3, which predicted that shorter exposure times cannot be necessarily compensated by higher laser powers, could not be confirmed. Furthermore, the mechanical properties of the different materials were characterized. Therefore, cylindrical samples were produced with different processes and parameters and tested with a compressive load. Also the densities and degrees of conversion were determined. All in all, elastic moduli between 0,40 and 1,37 GPa and load failures between 117 and 310 MPa were measured. It was detected that the photo initiator concentration influences the conversion behavior and thus the mechanical properties of the samples. While low concentrations led to lower degrees of conversion and lower elastic moduli, the samples produced with higher concentrations were more brittle with higher degrees of conversion and elastic moduli. The highest elastic modulus was measured for samples which were produced in OC-V with 2 wt.-% Irgacure® Ox02. Moreover, the mechanical properties of samples produced with 2PP can be influenced by the utilized laser power. This is reasoned by the voxel sizes which can be adjusted by the laser power and which determine the overlap of vicinal voxels at distinct hatch and slice distances. In the overlap area double exposure takes place which can lead to higher degrees of conversion. It was found that with sufficient laser powers the 2PP leads to higher elastic moduli and load failures than the 1PP. Capital 5.3 deals with the scale-up of the photon polymerization technique. After the discussion of the challenges, two exposure strategies were used to produce macroscopic scaffold structures. Especially, the vat setup has to be emphasized which can be used to build structures with basically unlimited structure heights by means of the 2PP technique. One of the major challenges concerning the scale-up of the 2PP is the speed-up of the process. Therefore, the scan speeds as well as the acceleration of the positioning system play important roles. Moreover it was detected that further parallelizing techniques as the utilization of diffraction optical elements are needed in order to achieve a sufficient speed-up of the 2PP technology. The standard exposure setup with air objectives was used to fabricate millimeter-sized structures in ORMOCER®s which high quality. Though the maximal achievable structure height is limited by the working distance of the objective used, the setup is suitable for the fabrication of macroscopic scaffolds which can be utilized for biological or mechanical testing. Moreover, the biodegradable MB-47 was successfully used for the fabrication of Drug Delivery structures. The vat setup bases on a vat/bath as material reservoir with transparent bottom, a sample holder moveable in the vertical (z) direction, and an upside down x-y-scanning objective. The sample can be moved upwards which enables one to build structures whose heights are not limited by the working distance of the employed objective anymore. This setup was used to fabricate a model of the statue of liberty with a height of 2 cm and millimeter-sized scaffolds with pore sizes in the area between 40 and 500 µm in ORMOCER®-V. Moreover, the human ossicles in life size, a scaffold in the shape of the human stapes, different test scaffold structures for mechanical and biological investigations and drug delivery structures were build. The achieved maximum building rate was 10 mm^3/h. So far, the speed-up and scale-up potentials of the air-bearing positioning system haven’t been exhausted when using the vat setup. Therefore, the setup has to be optimized regarding weight and stability in order to realize higher accelerations of up to 10 m/s^2. This would enable build rates of up to 60 mm3/h with a scan speed of 224 mm/s and slice and hatch distances of 15 and 10 µm. Moreover, the speed-up by means of diffractive optical elements was experimentally investigated. Therefore, an optical setup was constructed which includes the diffractive optical element, some lenses, an objective, and a blind to blank the zero order. By this a 2 x 2 spot matrix was generated which was used for the simultaneous fabrication of four drug delivery structures and the production of single scaffold structures. In both cases an increase of the polymerization rate was achieved regarding to structuring without diffractive optical elements. For the fabrication of the scaffold structures two different scan strategies were performed. Using the first one, a scaffold was built up by the simultaneous structuring of four scaffolds’ gyroid unit cells. After finishing these cells, more cells were stitched to them until a millimeter-sized scaffold was achieved. For this strategy, it’s important that the size of the unit cell design is adjusted to the focal matrix distances. With the second strategy a scanning of the whole spot matrix along the whole scaffold flank is performed. By this it was possible to produce a pile of interleaved beams which represents a woodpile-like scaffold. The fact that the produce lines of each layer are as long as scaffold flank leads to the advantage that higher scan speeds and thus build rates can be achieved than with the first strategy. Nevertheless, the realized maximum build rates weren’t exceeding the build rates which were reached by using the standard setup or the vat setup. Thus, more optimization of parameters and setup is needed. If focused laser lights transmits through an interface of two materials with different refractive indices, spherical aberration occurs which leads to blurring of the focal intensity distribution especially in the axial direction. When using air objectives this blurring affects the structuring results. Hence theoretical and experimental investigations were done in order to optimize exposure routines. When using the standard exposure setup, power adoption was performed during the structuring process which allows holding the maximum focal intensity constant at varying focal depths in the presence of spherical aberration influences. By this, a clear improvement of the scaffolds’ quality and homogeneity along the axial direction was achieved. Furthermore, the vat setup with the NA 0.60 objective was used to perform an experimental in situ mapping of the focal axial intensity distribution for different focal depths. A voxel field function was extracted from produced voxel fields and correlated with the axial intensity distribution. Therefore, it was assumed that the chemical interaction volume is equal to the technical interaction volume. The experimental results showed clearly the presence of side maxima which are typical for spherical aberration influences. The distances between them were predicted quite exactly by theoretical simulations. Finally, the spherical aberrations were reduced by the correction collar of the objective. The resulting intensity distribution was also mapped with the vat setup and no side maxima were found for the experimental intensity distribution. Moreover the contrast of the main maximum was clearly improved. Overall, it can be concluded that within this work a noticeable progress in the scale-up of the two-photon polymerization technique was achieved which is important for the fabrication of scaffold structures for the regenerative medicine. The realized structure dimensions and build rates exceed all, so far, known specifications of structures fabricated by two-photon polymerization. Moreover, basic knowledge of the most important aspects of the scale-up was discovered by thoroughly theoretical and experimental investigations. Nevertheless, there is still much improvement necessary to establish the two photon polymerization technique as a competitive tool for the production of scaffold structures which are larger than 1 cm^3. Higher scan speeds and advanced setups with diffractive optical elements must be applied to achieve build rates in the range over 1 cm^3/h. Due to the lack in flexibility of usual diffractive optical elements, it is recommended to use spatial light modulators which are dynamic adjustable diffractive optical elements. With them it is possible to vary the spot intensity distribution, spot number as well as the spot distances during the process. Finally, it is imaginable that in future the vat setup combined with a spatial light modulator can be used for the fabrication of large macro structures with finest details in adequate time. But therefore, it is necessary to perform thoroughly investigations concerning the potentials of spatial light modulators. Moreover, the theoretical and experimental investigations on the reaction kinetics show that voxel growth is a complex process which is possibly affected by nonlinear optical interactions aside from the two-photon absorption phenomenon. Thus, intensive study should be done in order to, for example, quantify the influence of an intensity-dependent refractive index on the voxel growth. Maybe, results could be used to improve the voxel growth model of this work which bases on the separate consideration of the technical and chemical interaction volumes. A powerful tool enabling the prices prediction of voxel growth characteristics depending on material and focusing optics would help to improve the detail quality of fabricated scaffolds. KW - Tissue Engineering KW - Polymere KW - Mikrofertigung KW - Two-photon polymerization KW - Two-photon absorption KW - Scaffold fabrication KW - Zwei-Photonen-Polymerisation KW - Zweiphotonenabsorption KW - Reaktionskinetik KW - Raman-Spektroskopie Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-130161 ER - TY - THES A1 - Slobodskyy, Anatoliy T1 - Diluted magnetic semiconductor Resonant Tunneling Structures for spin manipulation T1 - Verdünnt magnetische Halbleiter Resonante Tunnel-Strukturen für Spin Manipulation N2 - In this work we investigate magnetic resonant tunneling diode (RTD) structures for spin manipulation. All-II-VI semiconductor RTD structures based on [Zn,Be]Se are grown by molecular beam epitaxy. We observe a strong, magnetic field induced, splitting of the resonance peaks in the I-V characteristics of RTDs with [Zn,Mn]Se diluted magnetic semiconductors (DMS) quantum well. The splitting saturates at high fields and has strong temperature dependence. A phonon replica of the resonance is also observed and has similar behaviour to the peak. We develop a model based on the giant Zeeman splitting of the spin levels in the DMS quantum well in order to explain the magnetic field induced behaviour of the resonance. N2 - In dieser Arbeit werden magnetische resonante Tunneldioden (RTD) hinsichtlich ihrer Eignung zur Spin-Manipulation untersucht. [Zn, Be]Se basierende II-VI RTD-Strukturen wurden mittels Molekularstrahlepitaxie gewachsen. Man beobachtet eine starke, vom Magnetfeld induzierte Aufspaltung der Resonanz in der U-I Kennlinie derjenigen RTDs, die über einen Quantentrog aus [Zn, Mn]Se verdünnt magnetischen Halbleiter (DMS) verfügen. Diese Aufspaltung hat eine starke Temperaturabhängigkeit und erreicht bei hohen Feldern eine Sättigung. Eine Phononen-Replika der Resonanz wird ebenfalls beobachtet und hat ähnliche Eigenschaften wie die Resonanz selbst. Es wird ein Modell entwickelt, welches auf der Giant-Zeeman-Aufspaltung der Spin-Aufgespalteten Niveaus des DMS-Quantentrogs basiert, um das magnetfeldabhängige Verhalten der Resonanz zu erklären. KW - Resonanz-Tunneldiode KW - Semimagnetischer Halbleiter KW - Magnetoelektronik KW - spintronik KW - spin Injektion KW - verdünnt magnetische Halbleiter KW - resonante Tunneldioden KW - spintronics KW - spin injection KW - diluted magnetic semiconductors KW - resonant tunneling diode Y1 - 2005 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-18263 ER - TY - THES A1 - Schütz, Philipp T1 - Dimensionality-Driven Metal-Insulator Transition in Spin-Orbit-Coupled SrIrO\(_3\) T1 - Dimensionalitätsgetriebener Metal-Isolator-Übergang in Spin-Bahn-gekoppeltem SrIrO\(_3\) N2 - In the past decades correlated-electron physics due to strong Coulomb interactions and topological physics caused by band inversion often induced by strong spin-orbit coupling have been the workhorses of solid state research. While commonly considered as disparate phenomena, it was realized in the early 2010s that the interplay between the comparably strong Coulomb and spin-orbit interactions in the $5d$ transition metal oxides may result in hitherto unforeseen properties. The layered perovskite Sr$\textsubscript{2}$IrO$\textsubscript{4}$ has attracted special attention due to the observation of an unconventional Mott-insulating phase and predictions of exotic superconductivity. Less is known about its three-dimensional counterpart SrIrO$\textsubscript{3}$, since rather than the cubic perovskite structure it adopts the thermodynamically stable hexagonal polymorph thereof. This thesis therefore sets out to establish the synthesis of epitaxially stabilized perovskite SrIrO$\textsubscript{3}$ by pulsed laser deposition and to investigate its electronic and magnetic structure by state-of-the-art x-ray spectroscopy techniques. In this endeavor the appropriate thermodynamic conditions for the growth of high-quality SrIrO$\textsubscript{3}$ are identified with a focus on the prevention of cation off-stoichiometry and the sustainment of layer-by-layer growth. In the thus-optimized films the cubic perovskite symmetry is broken by a tetragonal distortion due to epitaxial strain and additional cooperative rotations of the IrO$\textsubscript{6}$ octahedra. As a consequence of the thermodynamic instability of the IrO$\textsubscript{2}$ surface layer, the films unexpectedly undergo a conversion to a SrO termination during growth. In an attempt to disentangle the interplay between spin-orbit and Coulomb interaction the three-dimensional electronic structure of perovskite SrIrO$\textsubscript{3}$ is investigated in a combined experimental and theoretical approach using soft x-ray angle-resolved photoelectron spectroscopy and \textit{ab initio} density functional theory calculations. The experimentally found metallic ground state hosts coherent quasiparticle peaks with a well-defined Fermi surface and is theoretically described by a single half-filled band with effective total angular momentum $J_\text{eff} = 1/2$ only upon incorporation of a sizeable local Coulomb repulsion and -- to a lesser extent -- the broken cubic crystal symmetry in the film. Upon reduction of the SrIrO$\textsubscript{3}$ thickness below a threshold of four unit cells the scales are tipped in favor of a Mott-insulating phase as the on-site Coulomb repulsion surmounts the diminishing kinetic energy upon transition into the two-dimensional regime. Concomitantly, a structural transition occurs because the corner-shared octahedral network between substrate and film imposes constraints upon the IrO$\textsubscript{6}$ octahedral rotations in the thin-film limit. The striking similarity between the quasi-two-dimensional spin-orbit-induced Mott insulator Sr$\textsubscript{2}$IrO$\textsubscript{4}$ and SrO-terminated SrIrO$\textsubscript{3}$ in the monolayer limit underlines the importance of dimensionality for the metal-insulator transition and possibly opens a new avenue towards the realization of exotic superconductivity in iridate compounds. Whether the analogy between SrIrO$\textsubscript{3}$ in the two-dimensional limit and its Ruddlesden-Popper bulk counterparts extends to their complex magnetic properties ultimately remains an open question, although no indications for a remanent (anti)ferromagnetic order were found. The unprecedented observation of an x-ray magnetic circular dichroism at the O~$K$-absorption edge of iridium oxides in an external magnetic field promises deeper insights into the intricate connection between the $J_\text{eff} = 1/2$ pseudospin state, its hybridization with the oxygen ligand states and the magnetic order found in the Ruddlesden-Popper iridates. N2 - In den vergangenen Jahrzehnten waren die Physik korrelierter Elektronen aufgrund starker Coulomb- sowie topologische Physik aufgrund durch Spin-Bahn-Wechselwirkung induzierter Bandinversion die Zugpferde der Festkörperforschung. Während diese zuvor gemeinhin als disjunkt wahrgenommen wurden, setzte sich Anfang der 2010er Jahre die Einsicht durch, dass das Zusammenspiel der ähnlich starken Coulomb- und Spin-Bahn-Wechselwirkung in $5d$ Übergangsmetalloxiden zu unvorhergesehenen Eigenschaften führen kann. Bedingt durch die Entdeckung einer unkonventionellen Mott-isolierenden Phase sowie Vorhersagen exotischer Supraleitung wurde dem geschichteten Perowskit Sr$\textsubscript{2}$IrO$\textsubscript{4}$ besondere Aufmerksamkeit zuteil. Über dessen dreidimensionales Pendant SrIrO$\textsubscript{3}$ ist weniger bekannt, da es anstelle der kubischen Perowskitstruktur eine thermodynamisch stabilere polymorphe Gitterstruktur annimmt. Ziel dieser Thesis ist daher die Synthese von epitaktisch stabilisiertem Perowskit-SrIrO$\textsubscript{3}$ mittels gepulster Laserablation sowie die Untersuchung dessen elektronischer und magnetischer Struktur mit modernsten Röntgenspektroskopiemethoden. In diesem Bestreben werden zunächst die thermodynamischen Bedingungen für das Wachstum von qualitativ hochwertigem SrIrO$\textsubscript{3}$ mit dem Fokus auf der kationischen Stöchiometrie sowie dem Erreichen lagenweisen Schichtwachstums identifiziert. In derart optimierten Filmen wird die kubische Symmetrie von einer tetragonalen Verzerrung aufgrund epitaktischer Verspannung sowie von kooperativen Verdrehungen der IrO$\textsubscript{6}$ Oktaeder gebrochen. Während des Wachstums findet infolge der thermodynamischen Instabilität der obersten IrO$\textsubscript{2}$ Lage eine Umwandlung zu einer SrO-Terminierung der Oberfläche statt. Mit dem Ziel das Zusammenspiel von Spin-Bahn- und Coulomb-Wechselwirkung in SrIrO$\textsubscript{3}$ zu entwirren wird dessen dreidimensionale elektronische Struktur in Kombination von winkelaufgelöster Photoelektronenspektroskopie im weichen Röntgenbereich und \textit{ab initio} Dichtefunktionaltheorie untersucht. Der experimentell beobachtete metallische Grundzustand weist kohärente Quasiteilchenzustände mit wohldefinierter Fermifläche auf und wird theoretisch durch ein halbgefülltes Band mit effektivem Gesamtdrehmoment $J_\text{eff} =1/2$ beschrieben, sofern eine substanzielle lokale Coulombabstoßung sowie - in geringerem Maße - die gebrochene kubische Symmetrie berücksichtigt werden. Bei Schichtdicken unterhalb von vier Einheitszellen neigt sich das Gleichgewicht zugunsten einer Mott-isolierenden Phase, da die lokale Coulombabstoßung die im Zweidimensionalen reduzierte kinetische Energie zunehmend überwiegt. Gleichzeitig findet ein struktureller Übergang statt, da das Netzwerk aus Sauerstoffoktaedern deren Rotationen in dünnen Filmen Randbedingungen auferlegt. Die verblüffende Ähnlichkeit zwischen dem quasi-zweidimensionalen Mott-Isolator Sr$\textsubscript{2}$IrO$\textsubscript{4}$ und SrO-terminiertem Monolagen-SrIrO$\textsubscript{3}$ unterstreicht die Bedeutung der Dimensionalität für den Metall-Isolator-Übergang und eröffnet neue Möglichkeiten zur Realisierung exotischer Supraleitung in Iridaten. Die Frage, ob sich die Analogie zwischen SrIrO$\textsubscript{3}$ im zweidimensionalen Limes und den quasi-zweidimensionalen Ruddlesden-Popper-Iridaten auf deren komplexe magnetische Eigenschaften erstreckt, bleibt schlussendlich offen, gleichwohl keine Hinweise auf eine remanente (anti-)ferromagnetische Ordnung hindeuten. Die bisher erste Beobachtung eines magnetischen Zirkulardichroismus an der O~$K$-Absorptionskante eines Iridiumoxids in einem externen Magnetfeld verspricht tiefere Einsichten in den komplexen Zusammenhang zwischen dem $J_\text{eff} = 1/2$ Pseudospin-Zustand, dessen Hybridisierung mit den Valenzzuständen der Sauerstoffliganden sowie der magnetischen Ordnung in Iridatverbindungen. KW - Festkörperphysik Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-212781 ER - TY - THES A1 - Müller, Matthias T1 - Dreidimensionale Konfigurationen von NMR Phased-Array Spulen mit vielen Einzelelementen T1 - Three-dimensional configurations of NMR phased-arrays with many coil elements N2 - In der vorliegenden Arbeit wurden alternative Phased-Array Konfigurationen untersucht, die eine gleichmäßige rÄaumliche Verteilung der Spulensensitivitäten für eine 2D parallel beschleunigte NMR-Bildgebung zur Verfügung stellen sowie eine höhere lokale Dichte probenrauschdominierter Einzelspulen als konventionelle Arraygeometrien ermöglichen. Hierzu wurde zunächst eine neuartige 16-Kanal Doppel-Spiral Arraygeometrie einem Birdcage-ähnlichen Spulenarray mit zwei Ringen aus je acht Spulenelementen gegenübergestellt, welches gewöhnlich in der klinischen Routine für NMR-Untersuchungen am menschlichen Kopf eingesetzt wird. Unter Verwendung analytischer Biot-Savart Berechnungen in der Entwicklungsumgebung Matlab konnten die jeweiligen Kodiereigenschaften sowie das mit den unterschiedlichen Arraykonfigurationen erzielbare intrinsische Signal-Rausch-Verhältnis ermittelt und verglichen werden. Zudem wurde auf gleiche Weise der Einfluss geometrischer Variationen im Aufbau des Doppel-Spiral Volumenarrays auf die intrinsische Isolation zwischen dem inneren, um +pi verdrehten und dem Äußeren, um -pi verdrehten Einfach-Spiral Spulenarray untersucht und Phased-Array Designs mit 32 unabhÄangigen Empfangselementen evaluiert. Im Rahmen einer experimentellen Evaluierung des Doppel-Spiral Arraykonzepts wurden zuerst einzelne Spulenelemente der unterschiedlichen 16-Kanal Volumenarrays verglichen, bevor eine Doppel-Spiral Phased-Array Prototypenspule aufgebaut wurde. Mit dieser konnten sowohl die vorausgesetzte intrinsische Entkopplung der zwei Einzel-Spiral Spulenarrays als auch die in alle drei Raumrichtungen homogene Verteilung der einzelnen Spulensensitivitäten anhand von Experimenten im NMR-System nachgewiesen werden. So war trotz der relativ geringen Anzahl von sechs unabhängigen Einzelkanälen eine um den Faktor 4 beschleunigte NMR-Untersuchung des menschlichen Kopfes mittels einer 3D MP-RAGE-Bildgebungssequenz möglich. Diese hohe Beschleunigung konnte für jede beliebige Orientierung der Kodierrichtungen in gleichermaßen guter Bildqualität erzielt werden und erwies sich somit als unabhängig von der gewünschten Positionierung des dreidimensionalen Untersuchungsvolumens. Das auf diese Weise bestätigte Konzept einer Doppel-Spiral Arraygeometrie stellt allerdings nicht nur eine gleichmäßige Sensitivitätsvariation entlang aller Raumrichtungen zur Verfügung, sondern ermöglicht auch eine höhere Dichte probenrauschdominierter Einzelspulen. In einem zweiten Ansatz wurde das Konzept räumlich kompakter Quadratur-Arrayelemente untersucht, die aus einer geeigneten geometrischen Kombination zweier Einzelspulen entstehen. Die Evaluierung der Leistungsfähigkeit einer derartigen Arrayelementkonfiguration erfolgte in diesem Fall durch den Vergleich einer aus vier Quadratur-Arrayelementen aufgebauten 8-Kanal Phased-Array Spule mit einem konventionellen 4-Kanal Spulenarray, welches sich aus vier waagrechten, in Reihen angeordneten Einzelspulen zusammensetzt. Die Kodiereigenschaften der jeweiligen Phased-Array Spulen sowie das zur Verfügung stehende intrinsische SNR wurden erneut mit Hilfe von Biot-Savart Simulationen in Matlab ermittelt. Diese zeigten, dass durch eine solche neuartige Elementkonfiguration eine Steigerung des erzielbaren Signal-Rausch-Verhältnisses von nahezu 30% erreicht werden kann. Zudem konnte eine deutliche Verbesserung der Kodiereigenschaften in Folge einer, bei gleicher Ausdehnung der Arraystruktur, verdoppelten Anzahl an Einzelspulen beobachtet werden. Eine experimentelle Untersuchung erfolgte anhand einer einfachen aus vier Quadratur-Arrayelementen aufgebauten 8-Kanal Phased-Array Spule. Mit dieser wurden im Kernspintomographen NMR-Untersuchungen an Phantomen durchgeführt, die den SNR-Gewinn sowie die signifikante Verbesserung der Kodiereigenschaften durch die Verwendung von Quadratur-Elementen in guter Übereinstimmung mit den Simulationsergebnissen bestätigen konnten. Eine derartige Steigerung der Leistungsfähigkeit eines gewöhnlichen, flachen Spulenarrays durch das Hinzufügen senkrechter, intrinsisch entkoppelter Spulenelemente zeigt sich auch in den Resultaten coronal und sagittal orientierter NMR-Bildgebungsuntersuchungen der Wirbelsäule eines gesunden Probanden. Hierbei sind selbst bei Beschleunigungen von einem Faktor 4 keine Artefakte aufgrund einer schlecht konditionierten parallelen Bildrekonstruktion zu beobachten. N2 - In the presented work, alternative phased-array configurations were investigated. They provide smooth spatial distributions of surface coil sensitivities for 2D accelerated parallel NMR imaging as well as over a higher spatial density of sample-noise dominated coil elements than conventional array geometries. To this end, a novel 16-channel double-spiral array design was compared to a birdcage-like array of two rings with 8 elements each, which is commonly used for NMR studies on the human head in clinical routine. The encoding capabilities and the achievable intrinsic signal-to-noise ratio of the different array structures were determined and compared utilizing Biot-Savart calculations in the development environment Matlab. In addition, geometrical variations in the double-spiral array design were investigated regarding their influence on the intrinsic isolation between the inner +pi twisted and the outer -pi twisted single-spiral array coil. Furthermore, phased-array setups with 32 independent receive elements were evaluated. Within the scope of an experimental evaluation of the double-spiral array coil concept single coil elements of different 16-channel volume array setups were compared, before a double-spiral phased-array prototype coil was constructed. With this prototype the essential intrinsic isolation between both single-spiral coil arrays could be verified as well as the coil sensitivity variations could be demonstrated to be smoothly distributed in all three spatial directions by experiments within the NMR system. Thus a factor 4 accelerated NMR imaging of the human head using a 3D MP-RAGE imaging sequence became possible despite the rather small amount of six independent receive channels. This high acceleration could be achieved for any arbitrary orientation of encoding directions with likewise good image quality and hence proved independent of the desired positioning of the three-dimensional imaging volume. The by this means confirmed concept of a double-spiral array geometry provides not only a smooth sensitivity distribution along all spatial directions but also allows a higher local density of sample-noise dominated single coil elements. In a second approach, the concept of spatial more compacted quadrature array elements was introduced, which are formed by an appropriate geometrical combination of two single surface coil elements. The performance of such an array element configuration was evaluated by a comparison of an 8-channel phased-array coil built out of four quadrature array elements with a conventional 4-channel coil array, which consists of four horizontal coil elements in a row. The encoding capabilities of the individual phased-arrays as well as the available intrinsic SNR were again determined by Biot-Savart simulations in Matlab. They showed that with such a novel element configuration an increased SNR of 30 % can be attained. Moreover, a significant improvement of encoding performance became also apparent in consequence of the doubled number of single coil elements while keeping the basic size of the phased-array structure the same. For experimental evaluation a straightforward 8-channel phased-array coil constructed out of four quadrature array elements was used. So NMR experiments were performed in the NMR system, with which the gain in SNR and the considerable improvement of encoding abilities due to the quadrature elements could be confirmed in close correlation to the simulations. The performance of a common planar coil array, which is similarly enhanced through adding perpendicular, intrinsically decoupled coil elements, is also shown by coronal and sagittal NMR imaging results of the spine of a healthy volunteer. In this case, no image artifacts are recognizable due to ill-conditioned parallel imaging reconstructions even for acceleration of a factor of four. KW - NMR-Bildgebung KW - MR KW - Phased KW - Array KW - Spulen KW - MR KW - phased KW - array KW - coil Y1 - 2010 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-52399 ER - TY - THES A1 - Spanheimer, Daniela Cornelia T1 - Dynamische Leistungsverstärkung bei GHz Frequenzen und Speichereigenschaften von nanoelektronischen GaAs/AlGaAs Transistoren T1 - Dynamic power gain at GHz frequencies and memory effects of nanoelectronic GaAs/AlGaAs transistors N2 - Es wurde gezeigt, dass durch die Vorpositionierung von Quantenpunkten, diese mit einem gezielten Abstand im Bereich von einigen 100 nm zueinander und daher mit einer definierten Dichte in Speicherbauelemente eingebracht werden können. Es wurde bei tiefen Temperaturen wohldefinierte Coulombblockade demonstriert. Durch die Analyse der Coulomb-Rauten war es möglich, auf die Größe und Ladeenergie von Quantenpunkten im Kanal zu schliessen. Es wurde gezeigt, dass vorpositionierte Quantenpunkte sehr gut als Floating Gate eingesetzt werden können. Die Speichereigenschaften dieser Quantenpunkte wurden im Hinblick auf die Hysteresebreite DeltaVth in Abhängigkeit der Kanalbreite, der Drainspannung und der Temperatur untersucht und diskutiert. Hierbei konnte eine deutliche Abhängigkeit der Thresholdspannung von der Kanalbreite der Struktur ermittelt werden. Für Strukturen mit einem breiten Kanal wurde festgestellt, dass der Stromfluss bereits bei negativen Gatespannungen einsetzt, während für schmale Strukturen positive Gatespannungen nötig sind, um einen Ladungstransport hervorzurufen. Zur Bestimmung der Temperaturstabilität der Ladezustände wurde sowohl die Thresholdspannung als auch die Hysteresebreite als Funktion der Probentemperatur im Bereich von 4.2K bis Raumtemperatur bei verschiedenen Drainspannungen bestimmt. Hierbei wurde festgestellt, dass die Hysteresebreite bis zu einer kritischen Temperatur stufenförmig abnimmt und danach wieder leicht ansteigt. Bei der Untersuchung der Threshold- Spannung wurde ein Unterschied Vth,zu und Vth,auf festgestellt. Erstmals konnte ein lateral und vertikal positionierter InAs Quantenpunkt als Speicher für den Betrieb bei Raumtemperatur demonstriert werden. Ferner wurde die Wirkung eines Gate-Leckstromes auf den gemessenen Drain- Strom eines monolithischen Drei-Kontakt-Struktur untersucht und diskutiert. Die untersuchten Proben basieren auf einem neuen Parallel-Design, in welchem das Gate nicht wie üblich zwischen Source und Drain positioniert wurde, sondern in serieller Verbindung mit dem Drain- oder Sourcekontakt, d.h. mit einem zentralen Drain zwischen Source und Gate, gesetzt wurde. Hierdurch konnte eine merkliche Reduzierung des Probeninnenwiderstandes erreicht werde. Zu Beginn wurden zur Charakterisierung der Probe Transportmessungen bei Raumtemperatur durchführt. Hierbei konnte verglichen mit herkömmlichen Quantendrahttranistoren realisiert auf demselbenWafer, zum einen eine deutlich höhere Transconductance durch das parallele Design erreicht werden. Zum anderen zeigte die ermittelte Transconductance nicht den erwarteten linearen Verlauf in Abhängigkeit der Drainspannung, sondern einen quadratischen. Die Messungen zeigten außerdem einen Abfall des Drain-Stromes ab einer kritischen Größe des Gate-Leckstromwertes, welcher auf ein dynamisches Gate, hervorgerufen durch die Ladungsträger aus dem Gate, zurückgeführt wird. Diese zusätzliche virtuelle Kapazität addiert sich in paralleler Anordnung zum geometrischen Gate-Kondensator und verbessert die Transistoreigenschaften. Zum Abschluss der Arbeit wurden Hochfrequenzmessungen zur Ermittlung einer Leistungsverstärkung von Drei-Kontakt-Strukturen bei Raumtemperatur für unterschiedliche Gate- und Drainspannungen durchgeführt. Um die Hochfrequenzeigenschaften der untersuchten Probe zu erhöhen, wurde hierfür ein Design gewählt, in welchem die Goldkontakte zur Kontaktierung sehr nahe an die aktive Region heranragen. Für diese Spannungskombination konnte für eine Frequenz im Gigaherz-Bereich eine positive Spannungsverstärkung > 1 dB gemessen werden. Höhere Spannungen führen zu einem Sättigungswert in der Leistungsverstärkung. Dies wird zurückgeführt auf den maximal zur Verfügung stehenden Strom in der aktiven Region zwischen den nahen Goldkontakten. Zudem wurde eine Lösung vorgestellt, um das fundamentale Problem der Impedanzfehlanpassung für Hochfrequenzmessungen von nanoelektronischen Bauelementen mit einem hohen Innerwiderstand zu lösen. Eine Anpassung der unterschiedlichen Impedanzen zwischen Bauelement und Messapparatur ist unbedingt notwendig, um Reflexionen bei der Übertragung zu vermeiden und somit die Gewinnoptimierung zu erhöhen. Zur Behebung der Fehlanpassung wurde im Rahmen dieser Arbeit ein Impedanz-Anpassungs-Netzwerk auf einer PCB-Platine realisiert, welches mit der Probe verbunden wurde. Die Anpassung wurde durch eingebaute Strichleitungen in das Layout des Anpassungsboards vorgenommen. Durchgeführte Simulationen der Probe in Verbindung mit dem Anpassungs-Netzwerk bestätigten die experimentellen Ergebnisse. Durch die Anpassung konnte der simulierte Reflexionskoeffizient deutlich reduziert werden, bei gleichzeitiger Erhöhung des Transmissionskoeffizienten. Ebenfalls zeigten die Messungen an einer Drei-Kontakt-Struktur mit Anpassungs-Board eine signifikante Verbesserung der Leistungsverstärkung. N2 - Dynamical Charging and Discharging of laterally aligned quantum dot structures We can demonstrate that the direct positioning enables us to embed quantum dots with given periods to each other of only a few 100 nm and therefore with a defined density into the memory-structures. For low temperatures, well defined Coulombblockade can be observed. The analysis of the measured diamond patterns allows the determination of the dimension and the charging energy of the embedded quantum dots in the channel. The memory properties of these quantum dots were analyzed and discussed in terms of the hysteresis width DeltaVth which depends on the channel width, the applied drain voltage and the device temperature. The measurements reveal a dependence of the threshold voltage on the channel width of the structure. For devices with a wide channel the current transport sets in with negative applied gate voltages, in contrast to structures with narrow channels, requiring positive gate voltages to cause a current flow through the channel. To explain these results we assume that in large channels a higher negative voltage is necessary to deplete the charges out of the channel due to the higher charge density. To analyze the temperature stability of the charge states the threshold voltage as well as the hysteresis width is detected as a function of the temperature for different drain voltages in the range of 4.2K up to room temperature. It is determined that the hysteresis width decreases to a critical temperature before it rises again. For the investigation of the threshold voltage a difference between Vth,up and Vth,down is demonstrated. We assume that this difference is caused by the different charging behavior for increasing charge energies. In this work, lateral and vertical positioned InAs quantum dots could be demonstrated as a memory device operated at room temperature for the first time. Improved transistor functionality caused by gate leakage currents in nanoscaled Three Terminal Structures Further we investigate the role of gate leakage on the drain current in a monolithic, unipolar GaAs/AlGaAs heterostructure based on three leaky coupled contacts. Two in-plane barriers, defined by rows of etched holes in a two-dimensional electron gas, separate the leaky gate from the central drain and the drain from the source. Because of this the internal resistance of the structure can be appreciably decreased. It should be noted that the observed differential voltage amplification in the gate leakage regime of the studied structure is by far larger compared to the voltage amplification of any in-plane wire transistor fabricated from the same wafer, which were controlled by two non-leaking in-plane gates. The calculated transconductance increases quadratically and not in a non-linear manner, as expected. A pronounced reduction of the drain current sets in when the gate starts to leak, pointing at a large parallel gate capacitor. We associate the gate-leakage current induced gating with a virtual floating gate induced by the space charge injected from the gate. The space charge can hereby be described by a parallel gate capacitor that can control a low dimensional channel lying nearby. High frequency measurements on Three Terminal Structures High frequency measurements for determination of the power gain in Three Terminal Structures are carried out at room temperature. To improve the high frequency properties of the investigated structures a special design was chosen, where the gold contacts for contacting the sample approach very closely the active switching region. The measurements show that negative gate voltages are much more efficient to the power gain than positive ones. For these voltage combinations a power gain > 1 dB for frequencies in the GHz range is detected, whereas the power gain saturates for higher voltages. This is interpreted in terms of the maximum number of charges in the active region between the gold contacts. Furthermore an answer to the fundamental obstacle of the impedance mismatch for high frequency measurements on nanoelectronic structures with high internal resistance is given. Such a matching between the device and the measurement setup is necessary to reduce signal reflections and therefore increase the gain. To match the impedances, an impedancematching- network on a PCB-plate (printed circuit board) via integrated stubs was realized. Simulation data of the sample in connection with the matching-network is in very good agreement with the experimental data. Using the network reduces the simulated reflection coefficient and simultaneously raises the transmission coefficient. The measurements also show a significant improvement of the power gain behaviour. KW - Verstärkung KW - Hochfrequenz KW - Nanoelektronik KW - HEMT KW - Quantenpunkt KW - Coulomb-Blockade KW - Leistungsverstärkung KW - power gain Y1 - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-37589 ER - TY - THES A1 - Junglas, Michael T1 - Dynamische Wechselwirkungen zwischen festkörperunterstützten kationischen Lipidbilayern und oligo-DNA T1 - Dynamic interactions between solid supported cationic lipid bilayers and oligo-DNA N2 - Das Aufbringen eines Lipidbilayers, den man als artifizielle Zellmembran ansehen kann, auf eine Festkörperoberfläche ist eine häufig genutzte Methode, um ihn mit physikalischen Messmethoden, wie zum Beispiel ATR-FTIR, FRAP, Neutronenstreuung oder wie in der vorliegenden Arbeit NMR, einfacher untersuchen zu können. Darüber hinaus ist die so präparierte Oberfläche, in Kombination mit vorhandener Halbleitertechnik, ein idealer Sensor, um das Verhalten von Biomolekülen in Wechselwirkung mit dem Lipidbilayer zu untersuchen. Das Fernziel dieser Entwicklung ist die Herstellung eines biokompatiblen Chips mit dem sich bisher sehr aufwendige Messungen stark vereinfachen und schneller durchführen lassen (Stichwort: lab on a chip). Für die zuverlässige Interpretation der durch einen solchen Sensor gewonnenen Informationen ist es allerdings unerlässlich vorher zum einen die Wechselwirkungen zwischen der Festkörperoberfläche und dem ihn bedeckenden Lipidbilayer und zum anderen die Wechselwirkung zwischen Biomolekülen und dem Lipidbilayer genauer zu untersuchen. Dazu wurden in der vorliegenden Arbeit Silicakugeln (Durchmesser im Submikrometerbereich) als Festkörpersubstrat verwendet und mit verschiedenen Lipidbilayern beschichtet. Um die Wechselwirkung dieses Systems mit Biomolekülen zu erforschen wurden DNA-Moleküle eingesetzt. Als Messmethode kam Festkörper-Deuterium-NMR zum Einsatz. Zunächst wurde der Einfluss der Festkörperoberfläche auf die Verteilung geladener Lipide in den beiden Hälften eines Bilayers, der aus geladenen und ungeladenen Lipiden zusammengesetzt war, ermittelt. Es zeigte sich, dass das negativ geladene Silica-Substrat eine Anreicherung der positiv geladenen Lipide in der dem Substrat zugewandten Seite des Bilayers bewirkte. Darüber hinaus reichert sich während des Aufbringes des Bilayers der Anteil der positiv geladenen Lipide in Abhängigkeit von der Inkubationszeit zu einer höheren Gesamtkonzentration als der Ausgangskonzentration an. Ein vor der Präparation eingestelltes Konzentrationsverhältnis aus verschiedenen Lipiden muss also nicht im festkörperunterstützten Bilayer vorliegen und die jeweiligen Lipidarten müssen nicht zwischen beiden Monolayern gleich verteilt sein. In weiteren Messungen wurden die Auswirkungen auf einen festkörperunterstützten Bilayer aus positiv geladenen Lipiden beim Ankoppeln von kurzen DNA-Strängen untersucht. Die DNA ist im Gegensatz zu den kationischen Lipiden unter Standardbedingungen negativ geladen. Es wurde nicht nur das Ankoppelverhalten einer DNA-Doppelhelix sondern auch das von einzelsträngig vorliegender DNA untersucht. Während die als Einzelstrang vorliegende DNA den molekularen Ordnungsparameter der Lipidfettsäureketten deutlich erhöhte, war die Erhöhung für die DNA-Doppelhelix geringer. Ein Vergleich der Eigendiffusionskoeffizienten der kationischen Lipide in Wechselwirkung mit den beiden DNA-Formen ergab keinen Änderung der Diffusion, wenn die DNA-Doppelhelix an den Bilayer koppelte. Die als Einzelstrang vorliegende DNA erniedrigt dagegen die Diffusion der Lipide. Die gemessenen Unterschiede der beiden DNA-Formen, sowohl bezüglich ihrer Auswirkung auf die molekulare Ordnung der Lipidketten, als auch auf die Eigendiffusion der Lipidmoleküle legen ein unterschiedliches Ankopplungsverhalten der beiden Formen nahe. Bei Experimenten, die versuchten das Ankoppeln der DNA für ein System aus zwei Lipidkomponenten genauer zu anaylsieren, zeigte sich der starke Einfluss des Substrats, der es unmöglich machte die Ergebnisse mit einem rein kationischen Lipidbilayer zu vergleichen. Die Ergebnisse der Messungen tragen zum besseren Verständnis der Wechselwirkungen zwischen Lipidbilayer und Festkörpersubstrat und zwischen Lipidbilayer und ankoppelnden Biomolekülen bei. N2 - The coating of a solid surface with a lipid bilayer, which can be regarded as an artificial cell membrane, is a widely used method to simplify the examination of the bilayer with physical measurement methods (e.g. ATR-FTIR, FRAP, neutron scattering or as in this thesis NMR). In addition, such a prepared surface in combination with present semiconductor technology, is an ideal sensor to examine the interaction of a lipid bilayer with biomolecules. The long-term objective of this development is the production of a biocompatible chip (also referred to as a lab on a chip) which simplifies and accelerates present day extensive measurements. For the reliable interpretation of the information gathered from such a chip, it is essential to closely examine on one hand the interaction between the solid surface and the coated lipid bilayer and on the other hand the interaction between the biomolecules and the lipid bilayer. To address this subject, silica beads with a diameter in the submicrometer range were used as a solid substrate and coated with various lipid bilayers. DNA molecules were used to examine the interaction of this system with biomolecules. Solid-state deuterium NMR was used as the measurement method. The effect of the solid surface on the distribution of charged lipids in the two monolayers of a lipid bilayer, which was composed of charged and neutral lipids, was examined first. It was shown that the negatively charged silica substrate caused an enrichment of positively charged lipids in the monolayer facing the substrate. In addition, the total concentration of positively charged lipids rose with respect to the initial concentration, depending on the incubation time. A concentration percentage adjusted prior to the preparation therefore does not necessarily exist in the solid supported bilayer and is not necessarily distributed equally between the two monolayers. Further experiments were made to study the influence of the coupling of short DNA strands to a solid supported bilayer composed of positively charged lipids. DNA has a negative charge in standard conditions, as opposed to the cationic lipids. The coupling behavior was not only studied for a DNA double helix but also for a single stranded DNA. The single stranded DNA gave a distinctive rise to the molecular order parameter of the lipids fatty acid chains. The increase for the DNA double helix was less distinct. Comparison of the self diffusion coefficients of the cationc lipids interacting with both forms of DNA showed no change for the diffusion when the DNA double helix coupled to the bilayer. In contrast the single stranded DNA decreased the diffusion of the lipids. The different effects of the two DNA forms both for their effect on the molecular order parameter of the lipid chains and for the self diffusion of the lipid molecules, suggests a different coupling behavior. Experiments to further analyze the coupling of DNA to a system containing two lipid components showed the strong influence of the substrate, which made it impossible to compare the results with respect to a pure cationic lipid bilayer. The results of the experiments contribute to a better comprehension of the interaction between lipid bilayers and solid substrates and between lipid bilayers and coupling biomolecules. KW - Lipidmembran KW - Festkörperoberfläche KW - DNS KW - Wechselwirkung KW - Kationische Lipidbilayer KW - Festkörpersupport KW - oligo-DNA KW - cationic lipid bilayer KW - solid support KW - oligo-DNA Y1 - 2004 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-16053 ER -