TY - JOUR A1 - Fuchs, Andreas A1 - Kreczy, Dorothea A1 - Brückner, Theresa A1 - Gbureck, Uwe A1 - Stahlhut, Philipp A1 - Bengel, Melanie A1 - Hoess, Andreas A1 - Nies, Berthold A1 - Bator, Julia A1 - Klammert, Uwe A1 - Linz, Christian A1 - Ewald, Andrea T1 - Bone regeneration capacity of newly developed spherical magnesium phosphate cement granules JF - Clinical Oral Investigations N2 - Objectives Magnesium phosphate-based cements begin to catch more attention as bone substitute materials and especially as alternatives for the more commonly used calcium phosphates. In bone substitutes for augmentation purposes, atraumatic materials with good biocompatibility and resorbability are favorable. In the current study, we describe the in vivo testing of novel bone augmentation materials in form of spherical granules based on a calcium-doped magnesium phosphate (CaMgP) cement. Materials and Methods Granules with diameters between 500 and 710 μm were fabricated via the emulsification of CaMgP cement pastes in a lipophilic liquid. As basic material, two different CaMgP formulations were used. The obtained granules were implanted into drill hole defects at the distal femoral condyle of 27 New Zealand white rabbits for 6 and 12 weeks. After explantation, the femora were examined via X-ray diffraction analysis, histological staining, radiological examination, and EDX measurement. Results Both granule types display excellent biocompatibility without any signs of inflammation and allow for proper bone healing without the interposition of connective tissue. CaMgP granules show a fast and continuous degradation and enable fully adequate bone regeneration. Conclusions Due to their biocompatibility, their degradation behavior, and their completely spherical morphology, these CaMgP granules present a promising bone substitute material for bone augmentation procedures, especially in sensitive areas. Clinical Relevance The mostly insufficient local bone supply after tooth extractions complicates prosthetic dental restoration or makes it even impossible. Therefore, bone augmentation procedures are oftentimes inevitable. Spherical CaMgP granules may represent a valuable bone replacement material in many situations. KW - implantation KW - calcium-magnesium phosphate cement KW - cement pastes KW - prefabricated granules KW - bone replacement material Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-268872 SN - 1436-3771 VL - 26 IS - 3 ER - TY - JOUR A1 - Gerhard-Hartmann, Elena A1 - Goergen, Helen A1 - Bröckelmann, Paul J. A1 - Mottok, Anja A1 - Steinmüller, Tabea A1 - Grund, Johanna A1 - Zamò, Alberto A1 - Ben-Neriah, Susana A1 - Sasse, Stephanie A1 - Borchmann, Sven A1 - Fuchs, Michael A1 - Borchmann, Peter A1 - Reinke, Sarah A1 - Engert, Andreas A1 - Veldman, Johanna A1 - Diepstra, Arjan A1 - Klapper, Wolfram A1 - Rosenwald, Andreas T1 - 9p24.1 alterations and programmed cell death 1 ligand 1 expression in early stage unfavourable classical Hodgkin lymphoma: an analysis from the German Hodgkin Study Group NIVAHL trial JF - British Journal of Haematology N2 - High programmed cell death 1 ligand 1 (PD-L1) protein expression and copy number alterations (CNAs) of the corresponding genomic locus 9p24.1 in Hodgkin- and Reed–Sternberg cells (HRSC) have been shown to be associated with favourable response to anti-PD-1 checkpoint inhibition in relapsed/refractory (r/r) classical Hodgkin lymphoma (cHL). In the present study, we investigated baseline 9p24.1 status as well as PD-L1 and major histocompatibility complex (MHC) class I and II protein expression in 82 biopsies from patients with early stage unfavourable cHL treated with anti-PD-1-based first-line treatment in the German Hodgkin Study Group (GHSG) NIVAHL trial (ClinicalTrials.gov Identifier: NCT03004833). All evaluated specimens showed 9p24.1 CNA in HRSC to some extent, but with high intratumoral heterogeneity and an overall smaller range of alterations than reported in advanced-stage or r/r cHL. All but two cases (97%) showed PD-L1 expression by the tumour cells in variable amounts. While MHC-I was rarely expressed in >50% of HRSC, MHC-II expression in >50% of HRSC was found more frequently. No obvious impact of 9p24.1 CNA or PD-L1 and MHC-I/II expression on early response to the highly effective anti-PD-1-based NIVAHL first-line treatment was observed. Further studies evaluating an expanded panel of potential biomarkers are needed to optimally stratify anti-PD-1 first-line cHL treatment. KW - fluorescence in situ hybridisation KW - major histocompatibility complex KW - immune checkpoint blockade KW - classical Hodgkin lymphoma KW - CD274 Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-258358 VL - 196 IS - 1 ER - TY - JOUR A1 - Straub, Anton A1 - Vollmer, Andreas A1 - Lâm, Thiên-Trí A1 - Brands, Roman C. A1 - Stapf, Maximilian A1 - Scherf-Clavel, Oliver A1 - Bittrich, Max A1 - Fuchs, Andreas A1 - Kübler, Alexander C. A1 - Hartmann, Stefan T1 - Evaluation of advanced platelet-rich fibrin (PRF) as a bio-carrier for ampicillin/sulbactam JF - Clinical Oral Investigations N2 - Objectives Mechanisms of wound healing are often impaired in patients with osteonecrosis of the jaw (ONJ). According to the guidelines for the treatment of this disease, early surgical intervention is indicated. However, surgery often faces complications such as wound healing disorders. The application of platelet-rich fibrin (PRF) after necrosectomy between bone and mucosa may constitute a promising approach to improve surgical results. An aspect that was not investigated until now is that PRF acts as a “bio-carrier” for antibiotics previously applied intravenously. Materials and methods We investigated the antimicrobial properties of PRF in 24 patients presenting ONJ undergoing systemic antibiosis with ampicillin/sulbactam. We measured the concentration of ampicillin/sulbactam in plasma and PRF and performed agar diffusion tests. Ampicillin/sulbactam was applied intravenously to the patient 10 minutes for blood sampling for PRF. No further incorporation of patients’ blood or PRF product with antibiotic drugs was obtained. Four healthy patients served as controls. Results Our results revealed that PRF is highly enriched with ampicillin/sulbactam that is released to the environment. The antibiotic concentration in PRF was comparable to the plasma concentration of ampicillin/sulbactam. The inhibition zone (IZ) of PRF was comparable to the standard ampicillin/sulbactam discs used in sensitivity testing. Conclusions The results of our study demonstrated that PRF is a reliable bio-carrier for systemic applied antibiotics and exhibits a large antimicrobial effect. Clinical relevance We describe a clinically useful feature of PRF as a bio-carrier for antibiotics. Especially when applied to poorly perfused tissues and bone such as in ONJ, the local release of antibiotics can reduce wound healing disorders like infections. KW - osteonecrosis of the jaw KW - osteoradionecrosis KW - antiresorptive drug-related osteonecrosis of the jaw KW - ARONJ KW - oral microbiome KW - agar diffusion test Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-324515 VL - 26 IS - 12 ER - TY - JOUR A1 - Fuchs, Andreas A1 - Hartmann, Stefan A1 - Ernestus, Karen A1 - Mutzbauer, Grit A1 - Linz, Christian A1 - Brands, Roman C. A1 - Kübler, Alexander C. A1 - Müller-Richter, Urs D. A. T1 - Mandibular intraosseous pseudocarcinomatous hyperplasia: a case report JF - Journal of Medical Case Reports N2 - Background Mandibular pseudocarcinomatous hyperplasia is a rare and generally benign pathology. We report on one of these rare cases. Case presentation The case history of a 73-year-old white man stated that he had a carcinoma of the oropharynx, which was primarily treated with radiotherapy and chemotherapy 4 years prior. As a result of radiotherapy he developed an osteoradionecrosis of his mandible and a consecutive pathological fracture of his left mandibular angle. Subsequent osteosynthesis was performed with a reconstruction plate. When we first saw him, his reconstruction plate was partially exposed with intraoral and extraoral fistulation. The resected bone of his defect-bordering jaw showed the typical pathohistological findings of an intraosseous mandibular pseudocarcinomatous hyperplasia. After a first reconstruction attempt with an iliac crest graft failed, definitive reconstruction of his mandible with a microvascular anastomosed fibula graft was achieved. Conclusions Intraosseous pseudocarcinomatous hyperplasia of the mandible is a rare differential diagnosis in maxillofacial surgery. Besides other benign epithelial neoplasms, such as calcifying epithelial odontogenic tumor, squamous odontogenic tumor, or different forms of ameloblastoma, the far more frequent invasive squamous cell carcinoma needs to be excluded. A misinterpretation of pseudocarcinomatous hyperplasia as squamous cell carcinoma must be avoided because it can lead to a massive overtreatment. KW - intraosseous KW - case report KW - pseudocarcinomatous hyperplasia KW - mandible Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-146873 VL - 16 IS - 268 ER - TY - THES A1 - Fuchs, Andreas Rudolf T1 - 3D-Pulverdruck von Zellkulturträgern mit Magnesium-Phosphat-Chemie T1 - 3d powder printing of scaffolds with a magnesium phosphate chemistry N2 - In der vorliegenden Arbeit wurden erstmals im 3D-Pulerdruckverfahren hergestellte Struvit-Matrizes auf ihre Eignung als Trägermaterial für Knochenzellen in vitro untersucht. Hierzu wurde die Zytokompatibilität sowie die chemische Löslichkeit von gedruckten Struvit-Strukturen betrachtet. In einem zweiten Schritt wurde untersucht, ob die biologische Funktion von BMP-2-Lösungen nach Durchlaufen des Druckprozesses erhalten bleibt und ob es möglich ist, BMP-2 unter Beibehaltung seiner biologischen Wirksamkeit direkt in Struvit-Matrizes zu drucken. Als Reaktanten zur Herstellung der Struvit-Matrizes wurde modifiziertes Farringtonit-Pulver mit definierter Körnung und eine äquimolare Binder-Lösung aus DAHP und ADHP verwendet. Die untersuchten Zellkulturträger mit Magnesiumammoniumphosphatchemie zeigten eine ausreichende Zytokompatibilität in vitro. Außerdem wurde gezeigt, dass thermolabile Proteine wie BMP-2 im 3D-Pulverdruckverfahren unter weitgehender Beibehaltung ihrer biologischen Wirksamkeit in vitro grundsätzlich prozessierbar sind. Die Freisetzung direkt eingedruckter Proteine aus den Struvit-Matrizes blieb jedoch hinter den Erwartungen zurück. Mit Struvit steht ein alternatives Zementsystem für den 3D-Pulverdruck zur Verfügung, welches spezifische Vorteile gegenüber den etablierten Calciumphosphaten bietet. Weitere Untersuchungen sind erforderlich, um die Ursache für die geringe BMP-Freisetzung aus den Struvit-Matrizes zu ermitteln und die Vorteile der neutralen Abbindereaktion voll nutzen zu können. N2 - The purpose of the present study was the investigation of 3d powder printed struvite-scaffolds as a carrier material for osteoblastic cells in vitro. For this purpose, their cytocompatibility and their chemical solubility were observed. In a second step we analysed, if BMP-2 could pass through the whole printing process without losing its biological function and furthermore if it is possible to print BMP-2 directly into struvite-scaffolds without a significant loss of biological activity. As reactants for the fabrication of the struvite-scaffolds, we used a modified farringtonite-powder and a binder solution consisting of an equimolar mixture of DAHP and ADHP. The investigated struvite-scaffolds showed a sufficient cytocompatibility. It was also shown, that thermolabile proteins, such as BMP-2, could be processed in 3d powder printing without losing much of their biological activity in vitro. The release of directly imprinted proteins out of the struvite scaffolds remained unsatisfying. Struvite is an alternative hydraulic-setting cement for 3d powder printing with certain advantages over the established calcium phosphate cements. Further investigations are necessary to identify the reasons for the low BMP-release out of the struvite-scaffolds and to take full advantage of the neutral setting reaction of struvite-cements. KW - Struvit KW - Rapid Prototyping KW - Knochen-Morphogenese-Proteine KW - 3D-Pulverdruck KW - BMP KW - Scaffold KW - 3d powder printing KW - scaffold KW - BMP KW - struvite Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-77415 ER - TY - JOUR A1 - Astakhov, Georgy V. A1 - Kraus, Hannes A1 - Soltamov, V. A. A1 - Fuchs, Franziska A1 - Simin, Dimitrij A1 - Sperlich, Andreas A1 - Baranov, P. G. A1 - Dyakonov, Vladimir T1 - Magnetic field and temperature sensing with atomic-scale spin defects in silicon carbide N2 - Quantum systems can provide outstanding performance in various sensing applications, ranging from bioscience to nanotechnology. Atomic-scale defects in silicon carbide are very attractive in this respect because of the technological advantages of this material and favorable optical and radio frequency spectral ranges to control these defects. We identified several, separately addressable spin-3/2 centers in the same silicon carbide crystal, which are immune to nonaxial strain fluctuations. Some of them are characterized by nearly temperature independent axial crystal fields, making these centers very attractive for vector magnetometry. Contrarily, the zero-field splitting of another center exhibits a giant thermal shift of −1.1 MHz/K at room temperature, which can be used for thermometry applications. We also discuss a synchronized composite clock exploiting spin centers with different thermal response. KW - condensed-matter physics KW - quantum physics Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-113025 ER - TY - JOUR A1 - Stojanović, Stevan D. A1 - Fuchs, Maximilian A1 - Fiedler, Jan A1 - Xiao, Ke A1 - Meinecke, Anna A1 - Just, Annette A1 - Pich, Andreas A1 - Thum, Thomas A1 - Kunz, Meik T1 - Comprehensive bioinformatics identifies key microRNA players in ATG7-deficient lung fibroblasts JF - International Journal of Molecular Sciences N2 - Background: Deficient autophagy has been recently implicated as a driver of pulmonary fibrosis, yet bioinformatics approaches to study this cellular process are lacking. Autophagy-related 5 and 7 (ATG5/ATG7) are critical elements of macro-autophagy. However, an alternative ATG5/ATG7-independent macro-autophagy pathway was recently discovered, its regulation being unknown. Using a bioinformatics proteome profiling analysis of ATG7-deficient human fibroblasts, we aimed to identify key microRNA (miR) regulators in autophagy. Method: We have generated ATG7-knockout MRC-5 fibroblasts and performed mass spectrometry to generate a large-scale proteomics dataset. We further quantified the interactions between various proteins combining bioinformatics molecular network reconstruction and functional enrichment analysis. The predicted key regulatory miRs were validated via quantitative polymerase chain reaction. Results: The functional enrichment analysis of the 26 deregulated proteins showed decreased cellular trafficking, increased mitophagy and senescence as the major overarching processes in ATG7-deficient lung fibroblasts. The 26 proteins reconstitute a protein interactome of 46 nodes and miR-regulated interactome of 834 nodes. The miR network shows three functional cluster modules around miR-16-5p, miR-17-5p and let-7a-5p related to multiple deregulated proteins. Confirming these results in a biological setting, serially passaged wild-type and autophagy-deficient fibroblasts displayed senescence-dependent expression profiles of miR-16-5p and miR-17-5p. Conclusions: We have developed a bioinformatics proteome profiling approach that successfully identifies biologically relevant miR regulators from a proteomics dataset of the ATG-7-deficient milieu in lung fibroblasts, and thus may be used to elucidate key molecular players in complex fibrotic pathological processes. The approach is not limited to a specific cell-type and disease, thus highlighting its high relevance in proteome and non-coding RNA research. KW - bioinformatics KW - miR KW - proteomics KW - functional network analysis KW - senescence KW - lung fibrosis KW - autophagy Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-285181 SN - 1422-0067 VL - 21 IS - 11 ER - TY - JOUR A1 - Jordan, Martin C. A1 - Jovic, Sebastian A1 - Gilbert, Fabian A1 - Kunz, Andreas A1 - Ertl, Maximilian A1 - Strobl, Ute A1 - Jakubietz, Rafael G. A1 - Jakubietz, Michael G. A1 - Meffert, Rainer H. A1 - Fuchs, Konrad F. T1 - Qualitätssteigerung der Abrechnungsprüfung durch Smartphone-basierte Fotodokumentation in der Unfall-, Hand-, und Plastischen Chirurgie JF - Der Unfallchirurg N2 - Hintergrund Die Fotodokumentation von offenen Frakturen, Wunden, Dekubitalulzera, Tumoren oder Infektionen ist ein wichtiger Bestandteil der digitalen Patientenakte. Bisher ist unklar, welchen Stellenwert diese Fotodokumentation bei der Abrechnungsprüfung durch den Medizinischen Dienst der Krankenkassen (MDK) hat. Fragestellung Kann eine Smartphone-basierte Fotodokumentation die Verteidigung von erlösrelevanten Diagnosen und Prozeduren sowie der Verweildauer verbessern? Material und Methoden Ausstattung der Mitarbeiter mit digitalen Endgeräten (Smartphone/Tablet) in den Bereichen Notaufnahme, Schockraum, OP, Sprechstunden sowie auf den Stationen. Retrospektive Auswertung der Abrechnungsprüfung im Jahr 2019 und Identifikation aller Fallbesprechungen, in denen die Fotodokumentation eine Erlösveränderung bewirkt hat. Ergebnisse Von insgesamt 372 Fallbesprechungen half die Fotodokumentation in 27 Fällen (7,2 %) zur Bestätigung eines Operationen- und Prozedurenschlüssels (OPS) (n = 5; 1,3 %), einer Hauptdiagnose (n = 10; 2,7 %), einer Nebendiagnose (n = 3; 0,8 %) oder der Krankenhausverweildauer (n = 9; 2,4 %). Pro oben genanntem Fall mit Fotodokumentation ergab sich eine durchschnittliche Erlössteigerung von 2119 €. Inklusive Aufwandpauschale für die Verhandlungen wurde somit ein Gesamtbetrag von 65.328 € verteidigt. Diskussion Der Einsatz einer Smartphone-basierten Fotodokumentation kann die Qualität der Dokumentation verbessern und Erlöseinbußen bei der Abrechnungsprüfung verhindern. Die Implementierung digitaler Endgeräte mit entsprechender Software ist ein wichtiger Teil des digitalen Strukturwandels in Kliniken. N2 - Background Photographic documentation of wounds, decubitus ulcers, tumors, open fractures and infections is an important part of digital patient files. It is unclear whether the photographic documentation has an effect on medical accounting with health insurance companies. Objective It was hypothesized that Smartphone-based systematic photographic documentation can improve the confirmation of proceeds-relevant diagnoses and procedures as well as the duration. Material and methods Staff in the emergency room, operating theater, outpatient clinic and on the wards were equipped with digital devices (Smartphone, tablet) including a photo-app. Medical accounting with the health insurance companies and identification of all case conferences in which the photographic documentation had effected a change in proceeds were analyzed for 2019 in a retrospective manner. Results Overall, 372 cases were discussed of which 27 cases were affected by the digital photographic documentation. Photographic documentation was used for clarification of the operative procedure (n = 5), primary diagnosis (n = 10), secondary diagnosis (n = 3), and length of hospitalization (n = 9). An average of 2119 € was negotiated and added per case affected by photographic documentation. Hereby, a level 1 trauma center gained an estimated 65,328 € in revenue. Discussion The use of Smartphone based photographic documentation can improve the overall quality of patient files and thus avoid loss of revenue. The implementation of digital devices with corresponding software is an important component of the digital structural change in hospitals. KW - Digitalisierung KW - Gesundheits-App KW - Künstliche Intelligenz KW - Plattform KW - Strukturwandel KW - artificial intelligence KW - database KW - digital transformation KW - photo app KW - surgery Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-232415 SN - 0177-5537 VL - 124 ER - TY - JOUR A1 - Kerwagen, Fabian A1 - Fuchs, Konrad F. A1 - Ullrich, Melanie A1 - Schulze, Andres A1 - Straka, Samantha A1 - Krop, Philipp A1 - Latoschik, Marc E. A1 - Gilbert, Fabian A1 - Kunz, Andreas A1 - Fette, Georg A1 - Störk, Stefan A1 - Ertl, Maximilian T1 - Usability of a mHealth solution using speech recognition for point-of-care diagnostic management JF - Journal of Medical Systems N2 - The administrative burden for physicians in the hospital can affect the quality of patient care. The Service Center Medical Informatics (SMI) of the University Hospital Würzburg developed and implemented the smartphone-based mobile application (MA) ukw.mobile1 that uses speech recognition for the point-of-care ordering of radiological examinations. The aim of this study was to examine the usability of the MA workflow for the point-of-care ordering of radiological examinations. All physicians at the Department of Trauma and Plastic Surgery at the University Hospital Würzburg, Germany, were asked to participate in a survey including the short version of the User Experience Questionnaire (UEQ-S) and the Unified Theory of Acceptance and Use of Technology (UTAUT). For the analysis of the different domains of user experience (overall attractiveness, pragmatic quality and hedonic quality), we used a two-sided dependent sample t-test. For the determinants of the acceptance model, we employed regression analysis. Twenty-one of 30 physicians (mean age 34 ± 8 years, 62% male) completed the questionnaire. Compared to the conventional desktop application (DA) workflow, the new MA workflow showed superior overall attractiveness (mean difference 2.15 ± 1.33), pragmatic quality (mean difference 1.90 ± 1.16), and hedonic quality (mean difference 2.41 ± 1.62; all p < .001). The user acceptance measured by the UTAUT (mean 4.49 ± 0.41; min. 1, max. 5) was also high. Performance expectancy (beta = 0.57, p = .02) and effort expectancy (beta = 0.36, p = .04) were identified as predictors of acceptance, the full predictive model explained 65.4% of its variance. Point-of-care mHealth solutions using innovative technology such as speech-recognition seem to address the users’ needs and to offer higher usability in comparison to conventional technology. Implementation of user-centered mHealth innovations might therefore help to facilitate physicians’ daily work. KW - mHealth KW - digital Health KW - speech recognition KW - usability KW - user-centered design KW - clinical systems Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-324002 VL - 47 IS - 1 ER - TY - JOUR A1 - Ewald, Andrea A1 - Fuchs, Andreas A1 - Boegelein, Lasse A1 - Grunz, Jan-Peter A1 - Kneist, Karl A1 - Gbureck, Uwe A1 - Hoelscher-Doht, Stefanie T1 - Degradation and bone-contact biocompatibility of two drillable magnesium phosphate bone cements in an in vivo rabbit bone defect model JF - Materials N2 - The use of bone-cement-enforced osteosynthesis is a growing topic in trauma surgery. In this context, drillability is a desirable feature for cements that can improve fracture stability, which most of the available cement systems lack. Therefore, in this study, we evaluated a resorbable and drillable magnesium-phosphate (MgP)-based cement paste considering degradation behavior and biocompatibility in vivo. Two different magnesium-phosphate-based cement (MPC) pastes with different amounts of phytic acid (IP 6) as setting retarder (MPC 22.5 and MPC 25) were implanted in an orthotopic defect model of the lateral femoral condyle of New Zealand white rabbits for 6 weeks. After explantation, their resorption behavior and material characteristics were evaluated by means of X-ray diffraction (XRD), porosimetry measurement, histological staining, peripheral quantitative computed tomography (pQCT), cone-beam computed tomography (CBCT) and biomechanical load-to-failure tests. Both cement pastes displayed comparable results in mechanical strength and resorption kinetics. Bone-contact biocompatibility was excellent without any signs of inflammation. Initial resorption and bone remodeling could be observed. MPC pastes with IP 6 as setting retardant have the potential to be a valuable alternative in distinct fracture patterns. Drillability, promising resorption potential and high mechanical strength confirm their suitability for use in clinical routine. KW - magnesium phosphate cement KW - phytic acid KW - drillability KW - bone replacement material Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-362824 SN - 1996-1944 VL - 16 IS - 13 ER -