TY - JOUR A1 - Sitter, Magdalena A1 - Pecks, Ulrich A1 - Rüdiger, Mario A1 - Friedrich, Sabine A1 - Fill Malfertheiner, Sara A1 - Hein, Alexander A1 - Königbauer, Josefine T. A1 - Becke-Jakob, Karin A1 - Zöllkau, Janine A1 - Ramsauer, Babett A1 - Rathberger, Katharina A1 - Pontones, Constanza A. A1 - Kraft, Katrina A1 - Meybohm, Patrick A1 - Härtel, Christoph A1 - Kranke, Peter T1 - Pregnant and postpartum women requiring intensive care treatment for COVID-19 — first data from the CRONOS-registry JF - Journal of Clinical Medicine N2 - (1) Background: Data on coronavirus 2 infection during pregnancy vary. We aimed to describe maternal characteristics and clinical presentation of SARS-CoV-2 positive women requiring intensive care treatment for COVID-19 during pregnancy and postpartum period based on data of a comprehensive German surveillance system in obstetric patients. (2) Methods: Data from COVID-19 Related Obstetric and Neonatal Outcome Study (CRONOS), a prospective multicenter registry for SARS-CoV-2 positive pregnant women, was analyzed with respect to ICU treatment. All women requiring intensive care treatment for COVID-19 were included and compared regarding maternal characteristics, course of disease, as well as maternal and neonatal outcomes. (3) Results: Of 2650 cases in CRONOS, 101 women (4%) had a documented ICU stay. Median maternal age was 33 (IQR, 30–36) years. COVID-19 was diagnosed at a median gestational age of 33 (IQR, 28–35) weeks. As the most invasive form of COVID-19 treatment interventions, patients received either continuous monitoring of vital signs without further treatment requirement (n = 6), insufflation of oxygen (n = 30), non-invasive ventilation (n = 22), invasive ventilation (n = 28), or escalation to extracorporeal membrane oxygenation (n = 15). No significant clinical differences were identified between patients receiving different forms of ventilatory support for COVID-19. Prevalence of preterm delivery was significantly higher in women receiving invasive respiratory treatments. Four women died of COVID-19 and six fetuses were stillborn. (4) Conclusions: Our cohort shows that progression of COVID-19 is rare in pregnant and postpartum women treated in the ICU. Preterm birth rate is high and COVID-19 requiring respiratory support increases the risk of poor maternal and neonatal outcome. KW - maternal critical care KW - COVID-19 KW - ARDS KW - SARS-CoV-2 KW - pregnancy KW - obstetrics Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-255257 SN - 2077-0383 VL - 11 IS - 3 ER - TY - JOUR A1 - Andelovic, Kristina A1 - Winter, Patrick A1 - Kampf, Thomas A1 - Xu, Anton A1 - Jakob, Peter Michael A1 - Herold, Volker A1 - Bauer, Wolfgang Rudolf A1 - Zernecke, Alma T1 - 2D Projection Maps of WSS and OSI Reveal Distinct Spatiotemporal Changes in Hemodynamics in the Murine Aorta during Ageing and Atherosclerosis JF - Biomedicines N2 - Growth, ageing and atherosclerotic plaque development alter the biomechanical forces acting on the vessel wall. However, monitoring the detailed local changes in wall shear stress (WSS) at distinct sites of the murine aortic arch over time has been challenging. Here, we studied the temporal and spatial changes in flow, WSS, oscillatory shear index (OSI) and elastic properties of healthy wildtype (WT, n = 5) and atherosclerotic apolipoprotein E-deficient (Apoe\(^{−/−}\), n = 6) mice during ageing and atherosclerosis using high-resolution 4D flow magnetic resonance imaging (MRI). Spatially resolved 2D projection maps of WSS and OSI of the complete aortic arch were generated, allowing the pixel-wise statistical analysis of inter- and intragroup hemodynamic changes over time and local correlations between WSS, pulse wave velocity (PWV), plaque and vessel wall characteristics. The study revealed converse differences of local hemodynamic profiles in healthy WT and atherosclerotic Apoe\(^{−/−}\) mice, and we identified the circumferential WSS as potential marker of plaque size and composition in advanced atherosclerosis and the radial strain as a potential marker for vascular elasticity. Two-dimensional (2D) projection maps of WSS and OSI, including statistical analysis provide a powerful tool to monitor local aortic hemodynamics during ageing and atherosclerosis. The correlation of spatially resolved hemodynamics and plaque characteristics could significantly improve our understanding of the impact of hemodynamics on atherosclerosis, which may be key to understand plaque progression towards vulnerability. KW - atherosclerosis KW - mouse KW - 4D flow MRI KW - aortic arch KW - flow dynamics KW - WSS KW - mapping KW - PWV KW - plaque characteristics Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-252164 SN - 2227-9059 VL - 9 IS - 12 ER - TY - JOUR A1 - Kaireit, Till F. A1 - Sorrentino, Sajoscha A. A1 - Renne, Julius A1 - Schoenfeld, Christian A1 - Voskrebenzev, Andreas A1 - Gutberlet, Marcel A1 - Schulz, Angela A1 - Jakob, Peter M. A1 - Hansen, Gesine A1 - Wacker, Frank A1 - Welte, Tobias A1 - Tümmler, Burkhard A1 - Vogel-Claussen, Jens T1 - Functional lung MRI for regional monitoring of patients with cystic fibrosis JF - PLoS ONE N2 - Purpose To test quantitative functional lung MRI techniques in young adults with cystic fibrosis (CF) compared to healthy volunteers and to monitor immediate treatment effects of a single inhalation of hypertonic saline in comparison to clinical routine pulmonary function tests. Materials and methods Sixteen clinically stable CF patients and 12 healthy volunteers prospectively underwent two functional lung MRI scans and pulmonary function tests before and 2h after a single treatment of inhaled hypertonic saline or without any treatment. MRI-derived oxygen enhanced T1 relaxation measurements, fractional ventilation, first-pass perfusion parameters and a morpho-functional CF-MRI score were acquired. Results Compared to healthy controls functional lung MRI detected and quantified significantly increased ventilation heterogeneity in CF patients. Regional functional lung MRI measures of ventilation and perfusion as well as the CF-MRI score and pulmonary function tests could not detect a significant treatment effect two hours after a single treatment with hypertonic saline in young adults with CF (p>0.05). Conclusion This study shows the feasibility of functional lung MRI as a non-invasive, radiation-free tool for monitoring patients with CF. KW - Physics KW - Magnetic resonance imaging KW - Functional magnetic resonance imaging KW - Cystic fibrosis KW - Oxygen KW - Pulmonary imaging KW - Hypertonic KW - Pulmonary function KW - Quantum chronodynamics Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-172457 VL - 12 IS - 12 ER - TY - JOUR A1 - Triphan, Simon M. F. A1 - Jobst, Bertram J. A1 - Anjorin, Angela A1 - Sedlaczek, Oliver A1 - Wolf, Ursula A1 - Terekhov, Maxim A1 - Hoffmann, Christian A1 - Ley, Sebastian A1 - Düber, Christoph A1 - Biederer, Jürgen A1 - Kauczor, Hans-Ulrich A1 - Jakob, Peter M. A1 - Wielpütz, Mark O. T1 - Reproducibility and comparison of oxygen-enhanced T\(_1\) quantification in COPD and asthma patients JF - PLoS ONE N2 - T\(_1\) maps have been shown to yield useful diagnostic information on lung function in patients with chronic obstructive pulmonary disease (COPD) and asthma, both for native T\(_1\) and ΔT\(_1\), the relative reduction while breathing pure oxygen. As parameter quantification is particularly interesting for longitudinal studies, the purpose of this work was both to examine the reproducibility of lung T\(_1\) mapping and to compare T\(_1\) found in COPD and asthma patients using IRSnapShotFLASH embedded in a full MRI protocol. 12 asthma and 12 COPD patients (site 1) and further 15 COPD patients (site 2) were examined on two consecutive days. In each patient, T\(_1\) maps were acquired in 8 single breath-hold slices, breathing first room air, then pure oxygen. Maps were partitioned into 12 regions each to calculate average values. In asthma patients, the average T\(_{1,RA}\) = 1206ms (room air) was reduced to T\(_{1,O2}\) = 1141ms under oxygen conditions (ΔT\(_1\) = 5.3%, p < 5⋅10\(^{−4})\), while in COPD patients both native T\(_{1,RA}\) = 1125ms was significantly shorter (p < 10\(^{−3})\) and the relative reduction to T\(_{1,O2}\) = 1081ms on average ΔT\(_1\) = 4.2%(p < 10\(^{−5}\)). On the second day, with T\(_{1,RA}\) = 1186ms in asthma and T\(_{1,RA}\) = 1097ms in COPD, observed values were slightly shorter on average in all patient groups. ΔT\(_1\) reduction was the least repeatable parameter and varied from day to day by up to 23% in individual asthma and 30% in COPD patients. While for both patient groups T\(_1\) was below the values reported for healthy subjects, the T\(_1\) and ΔT\(_1\) found in asthmatics lies between that of the COPD group and reported values for healthy subjects, suggesting a higher blood volume fraction and better ventilation. However, it could be demonstrated that lung T\(_1\) quantification is subject to notable inter-examination variability, which here can be attributed both to remaining contrast agent from the previous day and the increased dependency of lung T\(_1\) on perfusion and thus current lung state. KW - Medicine KW - Chronic obstrusive pulmonary disease KW - Asthma KW - Oxygen KW - Magnetic resonance imaging KW - Breathing KW - Pulmonary imaging KW - Protons KW - Diagnostic medicine Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-171833 VL - 12 IS - 2 ER - TY - JOUR A1 - Munz, Eberhard A1 - Jakob, Peter M. A1 - Borisjuk, Ljudmilla T1 - The potential of nuclear magnetic resonance to track lipids in planta JF - Biochimie N2 - Nuclear Magnetic Resonance (NMR) provides a highly flexible platform for non invasive analysis and imaging biological samples, since the manipulation of nuclear spin allows the tailoring of experiments to maximize the informativeness of the data. MRI is capable of visualizing a holistic picture of the lipid storage in living plant/seed. This review has sought to explain how the technology can be used to acquire functional and physiological data from plant samples, and how to exploit it to characterize lipid deposition in vivo. At the same time, we have referred to the current limitations of NMR technology as applied to plants, and in particular of the difficulty of transferring methodologies optimized for animal/medical subjects to plant ones. A forward look into likely developments in the field is included, anticipating its key future role in the study of living plant. KW - coconut cocos-nucifera KW - H-1-NMR spectroscopy KW - NMR-spectroscopy KW - camelina-sativa KW - high-throughput KW - oil storage KW - seeds KW - accumulation KW - field KW - metabolism KW - NMR KW - Lipid KW - MRI KW - CSI KW - Plants KW - Seeds Y1 - 2016 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-186828 VL - 130 ER - TY - JOUR A1 - Jende, Johann M. E. A1 - Kender, Zoltan A1 - Rother, Christian A1 - Alvarez-Ramos, Lucia A1 - Groener, Jan B. A1 - Pham, Mirko A1 - Morgenstern, Jakob A1 - Oikonomou, Dimitrios A1 - Hahn, Artur A1 - Juerchott, Alexander A1 - Kollmer, Jennifer A1 - Heiland, Sabine A1 - Kopf, Stefan A1 - Nawroth, Peter P. A1 - Bendszus, Martin A1 - Kurz, Felix T. T1 - Diabetic Polyneuropathy Is Associated With Pathomorphological Changes in Human Dorsal Root Ganglia: A Study Using 3T MR Neurography JF - Frontiers in Neuroscience N2 - Diabetic neuropathy (DPN) is one of the most severe and yet most poorly understood complications of diabetes mellitus. In vivo imaging of dorsal root ganglia (DRG), a key structure for the understanding of DPN, has been restricted to animal studies. These have shown a correlation of decreased DRG volume with neuropathic symptom severity. Our objective was to investigate correlations of DRG morphology and signal characteristics at 3 Tesla (3T) magnetic resonance neurography (MRN) with clinical and serological data in diabetic patients with and without DPN. In this cross-sectional study, participants underwent 3T MRN of both L5 DRG using an isotropic 3D T2-weighted, fat-suppressed sequence with subsequent segmentation of DRG volume and analysis of normalized signal properties. Overall, 55 diabetes patients (66 ± 9 years; 32 men; 30 with DPN) took part in this study. DRG volume was smaller in patients with severe DPN when compared to patients with mild or moderate DPN (134.7 ± 21.86 vs 170.1 ± 49.22; p = 0.040). In DPN patients, DRG volume was negatively correlated with the neuropathy disability score (r = −0.43; 95%CI = −0.66 to −0.14; p = 0.02), a measure of neuropathy severity. DRG volume showed negative correlations with triglycerides (r = −0.40; 95%CI = −0.57 to −0.19; p = 0.006), and LDL cholesterol (r = −0.33; 95%CI = −0.51 to −0.11; p = 0.04). There was a strong positive correlation of normalized MR signal intensity (SI) with the neuropathy symptom score in the subgroup of patients with painful DPN (r = 0.80; 95%CI = 0.46 to 0.93; p = 0.005). DRG SI was positively correlated with HbA1c levels (r = 0.30; 95%CI = 0.09 to 0.50; p = 0.03) and the triglyceride/HDL ratio (r = 0.40; 95%CI = 0.19 to 0.57; p = 0.007). In this first in vivo study, we found DRG morphological degeneration and signal increase in correlation with neuropathy severity. This elucidates the potential importance of MR-based DRG assessments in studying structural and functional changes in DPN. KW - diabetic polyneuropathy KW - dorsal root ganglion KW - magnetic resonance neurography KW - neuropathic pain KW - peripheral nervous system Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-212459 VL - 14 ER - TY - JOUR A1 - Winter, Patrick M. A1 - Andelovic, Kristina A1 - Kampf, Thomas A1 - Hansmann, Jan A1 - Jakob, Peter Michael A1 - Bauer, Wolfgang Rudolf A1 - Zernecke, Alma A1 - Herold, Volker T1 - Simultaneous measurements of 3D wall shear stress and pulse wave velocity in the murine aortic arch JF - Journal of Cardiovascular Magnetic Resonance N2 - Purpose Wall shear stress (WSS) and pulse wave velocity (PWV) are important parameters to characterize blood flow in the vessel wall. Their quantification with flow-sensitive phase-contrast (PC) cardiovascular magnetic resonance (CMR), however, is time-consuming. Furthermore, the measurement of WSS requires high spatial resolution, whereas high temporal resolution is necessary for PWV measurements. For these reasons, PWV and WSS are challenging to measure in one CMR session, making it difficult to directly compare these parameters. By using a retrospective approach with a flexible reconstruction framework, we here aimed to simultaneously assess both PWV and WSS in the murine aortic arch from the same 4D flow measurement. Methods Flow was measured in the aortic arch of 18-week-old wildtype (n = 5) and ApoE\(^{−/−}\) mice (n = 5) with a self-navigated radial 4D-PC-CMR sequence. Retrospective data analysis was used to reconstruct the same dataset either at low spatial and high temporal resolution (PWV analysis) or high spatial and low temporal resolution (WSS analysis). To assess WSS, the aortic lumen was labeled by semi-automatically segmenting the reconstruction with high spatial resolution. WSS was determined from the spatial velocity gradients at the lumen surface. For calculation of the PWV, segmentation data was interpolated along the temporal dimension. Subsequently, PWV was quantified from the through-plane flow data using the multiple-points transit-time method. Reconstructions with varying frame rates and spatial resolutions were performed to investigate the influence of spatiotemporal resolution on the PWV and WSS quantification. Results 4D flow measurements were conducted in an acquisition time of only 35 min. Increased peak flow and peak WSS values and lower errors in PWV estimation were observed in the reconstructions with high temporal resolution. Aortic PWV was significantly increased in ApoE\(^{−/−}\) mice compared to the control group (1.7 ± 0.2 versus 2.6 ± 0.2 m/s, p < 0.001). Mean WSS magnitude values averaged over the aortic arch were (1.17 ± 0.07) N/m\(^2\) in wildtype mice and (1.27 ± 0.10) N/m\(^2\) in ApoE\(^{−/−}\) mice. Conclusion The post processing algorithm using the flexible reconstruction framework developed in this study permitted quantification of global PWV and 3D-WSS in a single acquisition. The possibility to assess both parameters in only 35 min will markedly improve the analyses and information content of in vivo measurements. KW - 4D flow KW - pulse wave velocity KW - wall shear stress KW - radial KW - self-navigation KW - mouse KW - aortic arch KW - atherosclerosis KW - mice KW - flow KW - plaque KW - CMR KW - quantification KW - microscopy Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-259152 VL - 23 IS - 1 ER -