TY - THES A1 - Soares Machado, Jéssica T1 - Dosimetry-based Assessment of Radiation-associated Cancer risk for \(^9\)\(^9\)\(^m\)Tc-MAG3 Scans in Infants and Optimization of Administered Activities for \(^6\)\(^8\)Ga-labelled Peptides in Children and Adolescents T1 - Dosimetrie-basierte Abschätzung des strahlungsassoziierten Krebsrisikos für \(^9\)\(^9\)\(^m\)Tc-MAG3-Scans bei Säuglingen und Optimierung der verabreichten Aktivitäten für \(^6\)\(^8\)Ga-markierte Peptide bei Kindern und Jugendlichen N2 - In 2006, 0.18 Mio pediatric nuclear medicine diagnostic exams were performed worldwide. However, for most of the radiopharmaceuticals used data on biokinetics and, as a consequence on dosimetry, are missing or have not been made publicly available. Therefore, most of the dosimetry assessments presented today for diagnostic agents in children and adolescents rely on the biokinetics data of adults. Even for one of the most common nuclear medicine exams for this patient group, renal scintigraphy with 99mTc-MAG3 for assessing renal function measured data on biokinetics is available only from a study performed on four children of different ages. In particular, renal scans are among the most frequent exams performed on infants and toddlers. Due to the young age, this patient group can be classified as a risk group with a higher probability of developing stochastic radiation effects compared to adults. As there are only limited data on biokinetics and dosimetry in this patient group, the aim of this study is to reassess the dosimetry and the associated radiation risk for a larger number of infants undergoing 99mTc-MAG3 renal scans based on a retrospective analysis of existing patient data. Data were collected retrospectively from 34 patients younger than 20 months with normal (20 patients) and abnormal renal function (14 patients) undergoing 99mTc-MAG3 scans. The patient-specific organ activity was estimated based on a retrospective calibration which was performed based on a set of two 3D-printed infant kidneys (newborns: 8.6 ml; 1-year-old: 23.4 ml) filled with known activities. Both phantoms were scanned at different positions along the anteroposterior axis inside a water phantom, providing depth- and size-dependent attenuation correction factors for planar imaging. Time-activity curves were determined by drawing kidney, bladder, and whole body regions-of-interest for each patient, and subsequently applying the calibration factor for conversion of counts to activity. Patient-specific time-integrated activity coefficients were obtained by integrating the organ-specific time-activity curves. Absorbed and effective dose coefficients for each patient were assessed with OLINDA/EXM for the provided newborn and 1-year-old phantom. Based on absorbed dose values, the radiation risk estimation was performed individually for each of the 34 patients with the National Cancer Institute’s Radiation Risk Assessment Tool. The patients’ organ-specific mean absorbed dose coefficients for the patients with normal renal function were 0.04±0.03 mGy/MBq for the kidneys and 0.27±0.24 mGy/MBq for the bladder. This resulted in a mean effective dose coefficient of 0.02±0.02 mSv/MBq. Based on the dosimetry results, the evaluation of the excess lifetime risk (ELR) for the development of radiation-induced cancer showed that the group of newborns has an ELR of 16.8 per 100,000 persons, which is higher in comparison with the 1-year-old group with an ELR of 14.7 per 100,000 persons. With regard to the 14 patients with abnormal renal function, the mean values for the organ absorbed dose coefficients for the patients were: 0.40±0.34 mGy/MBq for the kidneys and 0.46±0.37 mGy/MBq for the bladder. The corresponding effective dose coefficients (mSv/MBq) was: 0.05±0.02 mSv/MBq. The mean ELR (per 100,000 persons) for developing cancer from radiation exposure for patients with abnormal renal function was 29.2±18.7 per 100,000 persons. As a result, the radiation-associated stochastic risk increases with the organ doses, taking age- and gender-specific influences into account. Overall, the lifetime radiation risk associated with the 99mTc-MAG3 scans is very low in comparison to the general population risk for developing cancer. Furthermore, due to the increasing demand for PET-scans in children and adolescents with 68Ga-labelled peptides, in this work published data sets for those compounds were analyzed to derive recommendations for the administered activities in children and adolescents. The recommendation for the activities to be administered were based on the weight-independent effective dose model, proposed by the EANM Pediatric Dosage Card for application in pediatric nuclear medicine. The aim was to derive recommendations on administered activities for obtaining age-independent effective doses. Consequently, the corresponding weight-dependent effective dose coefficients were rescaled according to the formalism of the EANM dosage card, to determine the radiopharmaceutical class of 68Ga-labeled peptides (“multiples”), and to calculate the baseline activities based on the biokinetics of these compounds and an upper limit of the administered activity of 185 MBq for an adult. Analogous to 18F-fluoride, a minimum activity of 14 MBq is recommended. As a result, for those pediatric nuclear medicine applications involving 68Ga-labeled peptides, new values for the EANM dosage card were proposed and implemented based on the results derived in this work. Overall, despite the low additional radiation-related cancer risk, all efforts should be undertaken to optimize administered activities in children and adolescents for obtaining sufficient diagnostic information with minimal associated radiation risk. N2 - Im Jahr 2006 wurden weltweit 0,18 Mio. nuklearmedizinische Diagnostikuntersuchungen bei Kindern durchgeführt. Für die meisten Radiopharmazeutika fehlen jedoch Daten zur Biokinetik und damit zur Dosimetrie oder diese wurden nicht öffentlich zugänglich gemacht. Daher basieren die meisten der heute vorgestellten Dosimetriedaten für Diagnostika bei Kindern und Jugendlichen auf den biokinetischen Daten von Erwachsenen. Selbst für eine der häufigsten nuklearmedizinischen Untersuchungen für diese Patientengruppe, die Nierenszintigraphie mit 99mTc-MAG3 für Bestimmung der Nierenfunktion, wurden Daten zur Biokinetik bisher nur für vier Kinder unterschiedlichen Alters erhoben. Insbesondere Nierenuntersuchungen gehören zu den häufigsten Untersuchungen bei Säuglingen und Kleinkindern. Aufgrund des jungen Alters kann diese Patientengruppe als Hochrisikogruppe mit einer höheren Wahrscheinlichkeit für das Eintreten stochastischer Strahlenwirkungen im Vergleich zu Erwachsenen eingestuft werden. Da es in dieser Patientengruppe nur begrenzte Daten zur Biokinetik und Dosimetrie gibt, ist das Ziel dieser Arbeit, die Dosimetrie und das damit verbundene Strahlenrisiko für eine größere Anzahl von Kleinkindern, die sich 99mTc-MAG3-Nierenscans unterziehen, auf der Grundlage einer retrospektiven Analyse bestehender Patientendaten neu zu bewerten. Die Daten wurden retrospektiv von 34 Patienten unter 20 Monaten mit normaler (20 Patienten) und eingeschränkter Nierenfunktion (14 Patienten) erhoben, bei denen 99mTc-MAG3-Scans durchgeführt wurden. Die patientenspezifische Organaktivität wurde basierend auf einer retrospektiven Kalibrierung abgeschätzt. Diese Kalibrierung basiert auf einem Satz von zwei 3D-gedruckten Säuglingsnieren, die mit bekannten Aktivitäten gefüllt wurden. Beide Phantome wurden an verschiedenen Positionen entlang der anteroposterioren Achse innerhalb eines Wasserphantoms gescannt und lieferten tiefen- und größenabhängige Schwächungskorrekturfaktoren für die planare Bildgebung. Die Zeit-Aktivitäts-Kurven wurden bestimmt, indem für jeden Patienten Nieren-, Blasen- und Ganzkörperregionen eingezeichnet und anschließend der entsprechende Kalibrierfaktor für die Umwandlung der Zählraten in Aktivität angewendet wurde. Patientenspezifische zeitintegrierte Aktivitätskoeffizienten wurden durch Integration der organspezifischen Zeit-Aktivitätskurven ermittelt. Die Energie- und effektiven Dosiskoeffizienten für jeden Patienten wurden mit OLINDA/EXM für das bereitgestellte Neugeborenen- und 1-Jahres-Phantom ermittelt. Basierend auf diesen Werten für die Energiedosen wurde eine individuelle Abschätzung des Strahlenrisikos für jeden der 34 Patienten mit dem Radiation Risk Assessment Tool des National Cancer Institute durchgeführt. Die organspezifischen mittleren Energiedosiskoeffizienten der Patienten mit normaler Nierenfunktion lagen bei 0,04±0,03 mGy/MBq für die Nieren und 0,27±0,24 mGy/MBq für die Blase, was in einem mittleren effektiven Dosiskoeffizienten von 0,02±0,02 mSv/MBq resultiert. Basierend auf den Ergebnissen der Dosimetrie, zeigte die Auswertung des zusätzlichen Lebenszeitrisikos ("excess lifetime risk", ELR) für die Entwicklung von strahleninduziertem Krebs, dass die Gruppe der Neugeborenen ein ELR von 16,8 pro 100.000 Personen aufweist, was höher ist als das der Gruppe der 1-jährigen mit 14,7 pro 100.000 Personen. Bei den 14 Patienten mit abnormaler Nierenfunktion waren die Mittelwerte für die Koeffizienten der organspezifischen Energiedosen für die Patienten: 0,40±0,34 mGy/MBq für die Nieren; 0,46±0,37 mGy/MBq für die Blase. Der effektivendosiskoeffizienten (mSv/MBq) waren: 0,05±0,02 mSv/MBq. Der mittlere ELR (pro 100.000 Personen) für die Entstehung von Krebs durch die Strahlenexposition von Patienten mit abnormaler Nierenfunktion betrug 29,2±18,7 pro 100.000 Personen. Das mit der Strahlung verbundene stochastische Risiko steigt mit den Organdosen unter Berücksichtigung alters- und geschlechtsspezifischer Einflüsse. Im Allgemeinen ist das mit den 99mTc-MAG3-Scans verbundene lebenslange Strahlenrisiko im Vergleich zum allgemeinen Bevölkerungsrisiko für die Entstehung von Krebs sehr gering. Aufgrund der steigenden Nachfrage nach PET-Scans bei Kindern und Jugendlichen mit 68Ga-markierten Peptiden wurden zusätzlich publizierte Datensätze für diese Verbindungen analysiert, um Empfehlungen für zu verabreichende Aktivitäten bei Kindern und Jugendlichen abzuleiten. Die Dosisberechnungen dazu basierten auf dem Modell einer gewichtsunabhängigen effektiven Dosis, das von der EANM Pediatric Dosage Card für den Einsatz in der pädiatrischen Nuklearmedizin vorgeschlagen wurde. Ziel war es, Empfehlungen zu verabreichenden Aktivitäten so aufzuteilen, dass sich altersunabhängige effektive Dosen ergeben. Dazu wurden die entsprechenden gewichtsabhängigen effektiven Dosiskoeffizienten gemäß dem Formalismus der EANM-Dosierungsempfehlung neu berechnet, um die radiopharmazeutische Klasse der 68Ga-markierten Peptide ("Multiples") zu bestimmen und die Werte für Basisaktivität zu berechnen. Diese basierend auf den Biokinetiken dieser Verbindungen und einer Obergrenze der verabreichten Aktivität von 185 MBq für einen Erwachsenen. Analog zu 18F-Fluorid, wird eine Mindestaktivität von 14 MBq empfohlen. Darauf basierend wurden für die pädiatrischen nuklearmedizinischen Anwendungen mit 68Ga-markierten Peptiden neue Werte für die EANM-Dosierungsempfehlung vorgeschlagen. Insgesamt sollten, trotz des geringen zusätzlichen strahlenbedingten Krebsrisikos, alle Anstrengungen unternommen werden, um die verabreichten Aktivitäten bei Kindern und Jugendlichen zu optimieren, um ausreichende diagnostische Informationen bei minimalem zusätzlichem Strahlenrisiko zu erhalten. KW - Biokinetics KW - Absorbed Doses KW - Risk Assessment KW - Pediatric Patients KW - Dosimetry KW - Nuclear Medicine KW - Pediatric Nuclear Medicine KW - Diagnostic Imaging Exams KW - Radiation Protection KW - Administered Activities KW - Radiation-associated Cancer Risk KW - Ga-68-labelled Peptides KW - Tc-99m-MAG3 Scans Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-192640 ER - TY - THES A1 - Hilbert, Fabian Michael T1 - Neue Methoden und Modelle für die diffusionsgewichtete Magnetresonanztomographie der Niere T1 - New methods and models for diffusion-weighted magnetic resonance imaging of the kidney N2 - Diffusionsgewichtete MR-Bilder sind ein wichtiger Bestandteil für die klinische Diagnostik verschiedener Pathologien, wie z.B. bei Schlaganfall oder Tumoren. Meistens wird ein mono-exponentielles Diffusionsmodell verwendet und über verschiedene Raumrichtungen gemittelt. Der Einfluss von Fluss auf das diffusionsgewichtete Signal und eine mögliche Richtungsabhängigkeit werden dabei vernachlässigt. Dabei machen Diffusionsmodelle, die mehr Eigenschaften des Signals abbilden, unter Umständen eine genauere Diagnostik möglich. Mit DTI wird die Richtungsabhängigkeit der Diffusion erfasst und bei IVIM wird der Beitrag von Fluss zum Signal berücksichtigt. Die Niere ist ein stark strukturiertes Organ und weist Anisotropie in der Diffusion auf. Außerdem ist die Niere ein sehr gut durchblutetes Organ. DTI und IVIM beschreiben also unabhängig voneinander zwei wichtige Aspekte des diffusionsgewichteten Signals in der Niere, ohne dass der Vorteil des jeweils anderen Modells Beachtung findet. In dieser Arbeit wurde das Modell IVOF zur umfassenden Beschreibung von Diffusionssignal vorgestellt, bei dem sowohl die Richtungsabhängigkeit der Diffusion, als auch das Signal der fließenden Spins und deren Richtungsabhängigkeit abgebildet wird. Die Vorteile von DTI und IVIM werden also in IVOF vereint und darüber hinaus auch die mögliche Anisotropie die Flusssignals berücksichtigt. Es konnte gezeigt werden, dass dieses Modell das diffusionsgewichtete Signal in der menschlichen Niere besser beschreibt als die herkömmlichen Modelle (DTI und IVIM) und auch besser als eine Kombination von DTI und IVIM, bei der ein isotroper Flussanteil des Signals angenommen wird. Es wurde weiterhin gezeigt, dass selbst wenn der Flussanteil im verwendeten Diffusionsmodell berücksichtigt wird, der tatsächlich gemessene Flussanteil in der Niere von der Art der Messung, d.h. Bewegungsempfindlichkeit des Gradientenschemas abhängt. Das bedeutet, dass der mikroskopische Fluss in der Niere nicht, wie häufig angenommen, komplett zeitlich inkohärent ist. Bei Vergleichen von IVIM Studien an der Niere ist es deshalb notwendig, die Bewegungsempfindlichkeit der jeweiligen Gradientenschemata zu berücksichtigen. Wie groß das absolute Verhältnis von kohärent zu inkohärent fließendem Signal ist, konnte nicht festgestellt werden. Ebenso wenig konnte die absolute Flussgeschwindigkeit bzw. die Art des Flusses (Laminare Strömung, Pfropfenströmung, oder andere) ermittelt werden. TSE hat sich als vielversprechendes, artefaktfreies Verfahren für die Aufnahme diffusionsgewichteter Bilder der Niere gezeigt. Im Vergleich mit dem Standardverfahren EPI wurden ähnliche Werte der Parameter von DTI und IVIM gefunden. Abweichungen zwischen EPI und TSE sind vor allem durch die Unschärfe der TSE Bilder aufgrund von T2-Zerfall zu erklären. Bis zur klinischen Anwendbarkeit diffusionsgewichteter TSE Bilder bzw. Parameterkarten sind noch einige Weiterentwicklungen der Methode nötig. Vor allem sind schärfere TSE Bilder erstrebenswert und es sollten mehrere Schichten in einer klinisch vertretbaren Zeitspanne aufgenommen werden, ohne dass dabei die zulässigen SAR Grenzwerte überschritten werden. Bei allen Untersuchungen in dieser Arbeit handelt es sich um Machbarkeitsstudien. Daher wurden alle Messungen nur an erwachsenen, gesunden Probanden durchgeführt, um zu zeigen, dass das jeweilige vorgeschlagene Modell zu den Daten passt bzw. dass die vorgeschlagene Methode prinzipiell funktioniert. Bei welchen Pathologien die hier vorgeschlagenen Methoden und Modelle einen diagnostischen Nutzen haben, muss in zukünftigen Studien erforscht werden. Außerdem wurden keine b- Werte zwischen 0 und 200 s/mm2 aufgenommen, bei denen fließende Spins noch signifikant zum Signal beitragen. Betrachtet man die Ergebnisse der Diffusionsbildgebung mit verschiedenen m1 in dieser Arbeit, dann ist neben dem b-Wert auch die Bewegungsempfindlichkeit m1 nötig, um das Signal in diesem Bereich korrekt zu beschreiben. Alles in allem sollte der Beitrag von Fluss zum diffusionsgewichteten MR-Signal in der Niere immer berücksichtigt werden. Die vielfältigen Einflüsse, die unterschiedliche Parameter auf das Signal von Mikrofluss haben, wurden in dieser Arbeit untersucht und präsentieren weiterhin ein spannendes Feld für kommende Studien. Diffusionsgewichtete TSE Sequenzen sind auch für die klinische Diagnostik eine potentielle Alternative zu Artefakt-anfälligen EPI Sequenzen. Bis dahin sollten jedoch die Bildschärfe und Abdeckung der diffusionsgewichteten TSE Sequenz weiter verbessert werden. N2 - Diffusion-weighted magnetic resonance (MR) imaging plays an important role in clinical diagnosis of various pathologies, such as stroke or tumors. Oftentimes a mono-exponential diffusion model is used and multiple diffusion directions are averaged. The potential influence of flow and a possible anisotropy of the signal are then neglected. Diffusion models that take these properties of the signal into account may allow a more accurate diagnosis. Diffusion tensor imaging (DTI) captures the directional dependence of diffusion, while the Intravoxel Incoherent Motion (IVIM) model accounts for the contribution of flow to the signal. Kidneys are strongly structured organs and exhibit anisotropic diffusion. Furthermore, kidneys are well perfused organs. DTI and IVIM both describe independently two important features of the diffusion-weighted signal in the kidneys, but neglect the advantages of the other model. The here presented work introduces a comprehensive diffusion model named Intravoxel Oriented Flow (IVOF). IVOF includes the possibilities of anisotropic diffusion and of flow. This way IVOF combines the advantages of DTI and IVIM and furthermore, accredits the possibility of anisotropic flow signal. It was shown that this model fits diffusion-weighted signal in the human kidney better than the standard diffusion models DTI and IVIM. IVOF even performs better than a combination of DTI and IVIM with an isotropic flow fraction. Moreover, it was shown that the actually measured flow fraction of the diffusionweighted signal in the kidneys depends on the imaging protocol, i.e. on the first gradient moment m1 of the diffusion gradient scheme. This means that the microscopic flow in the kidneys is not completely temporally incoherent, in contrast to what is often assumed. Therefore, a comparison of renal IVIM studies needs to pay attention to the used gradient schemes and their respective m1. The absolute ratio of coherent to incoherent flow signal could not be determined in this work and is subject to future work. The flow profile (whether laminar flow, plug flow or other) and the mean flow velocity should also be investigated in further studies. Turbo-Spin-Echo (TSE) proofed to be an artifact-free and promising tool for acquiring diffusion-weighted images of the kidney. Similar DTI and IVIM parameters were found when images where acquired with TSE compared to Echo-Planar Imaging (EPI). Differences between parameters acquired with EPI and TSE may be explained by blurring in the TSE images, which is caused by T2 -decay. Before diffusion-weighted TSE images and parameter maps can be used for clinical diagnosis, some further improvements of the method are necessary. Sharper TSE images are preferable and multiple slices need to be acquired within a clinically reasonable scan time without exceeding specific absorption rate limits. All studies described in this work are feasibility studies. For this reason, all measurements were performed on healthy, adult volunteers to show that the proposed diffusion model fits the data or that the proposed acquisition method works in principle. The diagnostic value of the here proposed methods and models should be investigated in future studies. No b-values between 0 and 200 s/mm2 were acquired. In this range, the signal of flowing spins contributes significantly to the total signal. With regard to the results in this work concerning diffusion-weighted imaging with multiple first gradient moments it is likely that the b-value is not sufficient to describe the signal in this regime. The first gradient moment of the diffusion-weighting gradients may be crucial to describe the signal correctly. All in all it is important to always consider the contribution of flow to the diffusionweighted MR signal in the kidneys. Manifold influences of acquisition parameters to the signal of micro flow were presented in this work and provide an interesting field for further research. Diffusion-weighted TSE sequences are a potential alternative to artifact-prone EPI sequences. However, for clinical application of diffusion-weighted TSE blurring needs to be reduced and 3-dimensional coverage should be increased. KW - Diffusionsgewichtete Magnetresonanztomografie KW - Niere KW - Diffusion Tensor Imaging KW - Intravoxel Incoherent Motion KW - Kidney KW - Turbo Spin Echo Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-141149 ER - TY - THES A1 - Fuchs, Kilian T1 - Absolutquantifizierung der myokardialen Perfusion mit hochauflösender MRT bei 3 Tesla T1 - Absolute Quantification of Myocardial Perfusion Using High-Resolution MRI at 3 T N2 - In den letzten Jahren hat die myokardiale MR-Perfusionsbildgebung als nichtinvasives Verfahren zur Darstellung von funktionellen Veränderungen des Myokards für die Diagnostik der KHK zunehmend an Bedeutung gewonnen. Während in den letzten 20 Jahren die kardiale MRT überwiegend bei einer Magnetfeldstärke von 1,5 T durchge-führt wurde und dies auch immer noch wird, findet aktuell eine rasante Verbreitung von MR-Systemen höherer Feldstärken statt. Von der neuen Hochfeldtechnik erhofft man sich vor allem, je nach Anwendung, eine deutliche Verbesserung der Bildqualität mit höherer räumlicher und zeitlicher Auflösung, wodurch der diagnostische Nutzen noch weiter gesteigert werden könnte. In der vorliegenden Arbeit wurden mittels First-Pass-MR-Bildgebung bei einer Magnet-feldstärke von 3 T quantitative Werte für die myokardiale Perfusion von 20 gesunden Probanden unter Ruhebedingungen bestimmt. Sowohl die erhobenen absoluten Perfusionswerte (0,859 ml/g/min im Mittel) als auch die Standardabweichung des mittleren MBF (0,298 ml/g/min) entsprechen den Messungen aus den früheren Publikationen dieser Arbeitsgruppe. In der Gesamtzusammenschau bisher veröffentlichter Perfusionsstudien zeigt sich eine relativ große Variabilität der publizierten Ruheflüsse. Dabei liegt der absolute MBF dieser Arbeit im mittleren Wertebereich dieser Streubreite. Er lässt sich auch mit den in PET-Studien ermittelten Ergebnissen in Einklang bringen, welche als Goldstandard zur Bestimmung der absoluten myokardialen Perfusion beim Menschen gelten. Die vorliegende Arbeit bestätigt die bereits in anderen 3 T-Studien untersuchten Vorteile der Hochfeld-MRT. Die höhere Magnetfeldstärke ermöglicht durch das größere SNR eine signifikant bessere räumliche Auflösung und besticht vor allem durch die hohe Bildqualität. Dies könnte bei der Erkennung kleiner, subendokardial gelegener Perfusionsdefekte sowie der Erstellung von transmuralen Perfusionsgradienten von Bedeutung sein und verspricht neben einer Reduktion von Partialvolumeneffekten auch eine Verminderung von „dark rim“-Artefakten. Um diese Vorteile entsprechend nutzen zu können, wird die Entwicklung von Methoden zur pixelweisen Bestimmung der absoluten Flüsse und farblich kodierten Darstellung derselben in Form von Perfusionskarten ein weiterer Schritt in Richtung klinisch einsetzbare Diagnostik sein. Eine Voraussetzung hierfür ist die Entwicklung einer exakten und sehr stabilen Bewegungskorrektur in weiterführenden Studien. Durch den Wechsel zu einer höheren Magnetfeldstärke von 3 T und den sich daraus ergebenden Vorteilen kann das Potential der MR-Perfusionsbildgebung, insbesondere der Bestimmung quantitativer Perfusionswerte, im Bereich der nichtinvasiven KHK-Diagnostik zukünftig weiter gesteigert werden. N2 - Absolute Quantification of Myocardial Perfusion Using High-Resolution MRI at 3 T KW - Kernspintomographie KW - Perfusion KW - Feldstärke KW - Quantifizierung KW - Absolutquantifizierung KW - myokardiale Perfusion KW - 3 Tesla KW - Hochfeld KW - Magnetresonanztomographie Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-107015 ER - TY - THES A1 - Eberlein, Uta T1 - Zusammenhang zwischen physikalischer Dosimetrie und DNA Doppelstrangbrüchen in Lymphozyten nach Radionuklidtherapie T1 - Relationship between internal dosimetry and DNA double strand breaks in lymphocytes after radionuclide therapy N2 - In der nuklearmedizinischen Therapie werden Radiopharmaka meist systemisch verabreicht. Primär werden dafür, wegen der kurzen Reichweite, beta-Strahler eingesetzt. Als Folge davon verteilt sich das Radiopharmakon im Körper, reichert sich in Organen und Zielstrukturen an und bestrahlt somit den Körper intern, im Gegensatz zur externen Bestrahlung bei der Strahlentherapie. Das Verteilungsmuster der verabreichten Aktivität im Körper wird durch die chemischen und physikalischen Eigenschaften des Radiopharmakons bestimmt. Außerdem sind die Aktivität und die Art der Anreicherung ausschlaggebend für die durch ionisierende Strahlung deponierte Energie im Körper, der Energiedosis. Gemeinsam haben externe und interne Bestrahlungsverfahren, dass der Patient ionisierender Strahlung ausgesetzt ist, die nicht nur die kranken Zellen zerstört, sondern auch gesunde Zellen schädigen kann. Dies geschieht durch direkte oder indirekte Wechselwirkung der Strahlung mit der DNA, die zur Schädigung der DNA-Struktur führt. Am häufigsten sind dabei Einzelstrangbrüche und Basenschäden. Die Doppelstrangbrüche sind im Vergleich zu Einzelstrangbrüchen und Basenschäden sehr selten aber sehr viel schädlicher für die Zelle, da die Reparatur komplizierter ist. Somit sind diese primär für den Zelltod oder für die Folgen nach fehlerhafter Reparatur verantwortlich. Eine sehr schnelle Antwort auf strahleninduzierte oder durch andere Stoffe, wie z.B. zytotoxische Substanzen, induzierte Doppelstrangbrüche ist die Phosphorylierung der Histon H2 Variante H2AX, die gamma-H2AX genannt wird. Zusätzlich reichert sich das Protein 53BP1 nach dem Erkennen eines Doppelstrangbruches durch Sensorproteine sofort am Chromatin, das den Doppelstrang umgibt, an. Damit ist 53BP1 ein weiterer Biomarker, der strahleninduzierte Doppelstrangbrüche sehr effektiv nachweisen kann und der auf sehr verlässliche Weise mit gamma-H2AX kolokalisiert. Mittels Immunfluoreszenzfärbung lassen sich gamma-H2AX und 53BP1 als umschriebene „Foci“, im Zellkern mikroskopisch darstellen und zählen. Unter der Annahme, dass ein Focus einem Doppelstrangbruch entspricht, kann die Anzahl der Foci im Zellkern als quantitativer Biomarker für DNA Doppelstrangbrüche und damit für die Strahlenexposition und Strahlenwirkung verwendet werden. Zudem zeigen Studien der Induktion von gamma-H2AX nach externer Bestrahlung von unterschiedlichen Gewebearten Linearität zwischen der Energiedosis und der Zahl der Foci im Zellkern. Weitere Studien beschäftigen sich mit den Auswirkungen externer Bestrahlung auf Patienten, aber nur wenige mit offenen radioaktiven Substanzen. Ziele dieser Arbeit waren daher: 1. Die Generierung einer bisher noch nicht beschriebenen in-vitro Kalibrierkurve nach interner Bestrahlung von Vollblut mit den in der Therapie eingesetzten beta-Strahlern. 2. Die gleichzeitige Bestimmung der physikalischen Dosis sowie der strahleninduzierten Anzahl der Foci in Lymphozyten, gewonnen aus Blutproben von Patienten nach Radiopeptidtherapie mit Lu-177 und Radioiodtherapie mit I-131. 3. Eine umfassende Beschreibung der Induktion und der Abnahme der Foci in den Lymphozyten aus den Blutproben der Patienten unter Einbeziehung der in-vitro Kalibrierung, um den dosis- und zeitabhängigen Verlauf der Anzahl der strahleninduzierten Foci zu bestimmen. Für die in-vitro Kalibrierung mit I-131 und Lu-177 wurden bei Probanden Blutproben gewonnen und mit unterschiedlichen Aktivitätskonzentrationen ergänzt. Das Ziel war, eine Energiedosis bis 100mGy zu erhalten. Das Ergebnis war, dass sich die Zahl der strahleninduzierten Foci in Abhängigkeit von der Energiedosis gut durch eine lineare Funktion beschreiben lässt, so wie es auch für die externe Bestrahlung bereits gezeigt wurde. Die Patientenstudien befassten sich mit dem Zusammenhang zwischen der im Blut deponierten Energiedosis und der Anzahl und dem zeitlichen Verlauf der induzierten Doppelstrangbrüche im peripheren Blut von Patienten unter Peptidrezeptor-Radionuklidtherapie mit Lu-177 DOTATATE/-TOC und Patienten unter Radioiodtherapie mit I-131 bei Ablationstherapien nach Operation eines differenzierten Schilddrüsenkarzinoms. Die durchschnittliche Anzahl induzierter DSB-Foci zeigte in den frühen Zeitpunkten einen linearen dosisabhängigen Anstieg. In den ersten Stunden nach Therapie stimmten die in-vitro Kalibrierung und die Zahl der strahleninduzierten Foci sowohl für Lu-177 als auch für I-131 für die Patientendaten gut überein. Die späteren Zeitpunkte werden durch eine Abnahme der Dosisrate und der Foci-Anzahl, bedingt durch Reparatur der DNA-Schäden, charakterisiert. Überstiegen die Blutdosiswerte in der ersten Stunde jedoch 20mGy (nur nach I-131-Gabe beobachtet), dann war die Induktion eines schnellen Reparaturprozesses festzustellen. Diese experimentellen Ergebnissen und Modellierungen beschreiben erstmalig die Dosisabhängigkeit und den zeitlichen Verlauf der in-vitro und in-vivo DNA-Schadensantwort nach Inkorporation von beta-emittierenden Radionukliden. N2 - In radionuclide therapy radiopharmaceuticals are administered mostly systemically. Primarily, beta-emitters are used because of their short range in tissue. As a result the radiopharmaceutical distributes within the human body and accumulates in organs and target structures. Thus, the body is irradiated internally, in contrast to external irradiation in radiotherapy. The pattern of the activity distribution within the human body is determined by the physical and chemical properties of the radiopharmaceutical. Furthermore, the amount of activity and its accumulation in organs or tissues is essential for the calculation of the absorbed dose which defines the energy deposited in the body by ionizing radiation. During internal or external irradiation, patients are exposed to ionizing radiation which does not only destroy the malignant cells but also damages healthy tissue and cells. This is mainly caused by direct and indirect interaction of the radiation with the DNA which damages the DNA structure. Most frequently, there are single strand breaks and base damages. DNA double strand breaks (DSBs) are rare; nevertheless, they are the most critical lesions for cells as repairing the damage is difficult. Unrepaired or misrepaired DNA could cause mutations, chromosomal aberrations or lead to cell death. The formation of a DNA DSB in nuclear chromatin results in the rapid phosphorylation of the histone H2 variant H2AX, then called gamma-H2AX. Furthermore, DSBs also recruit the damage sensor 53BP1 to the chromatin surrounding the DSBs, which leads to 53BP1 and gamma-H2AX co-localization in the chromatin surrounding a DSB. By immunofluorescence staining with gamma-H2AX and 53BP1 antibodies those biomarkers can be addressed by microscopically visible DNA damage protein foci, this is also known as the DNA damage focus assay. With progression of DSB repair, gamma-H2AX and 53BP1 foci disappear. It is assumed that one focus corresponds to one DSB. Therefore, the number of foci per cell can be used as a quantitative biomarker for DNA double strand breaks and hence for radiation exposure and radiation effects. Most studies dealing with the DNA damage focus assay performed in the last years were looking only on the effect of external irradiation after external radiation therapy or after diagnostic radiology procedures, but only few with the effects after administration of radiopharmaceuticals. Therefore, the aims of this thesis were: 1. To develop a method to generate an in-vitro calibration curve for the DSB focus assay after internal irradiation with beta-emitting radionuclides by creating a low dose and low dose-rate blood irradiation situation in-vitro, at dose-rates that are similar to the ones that have been observed in nuclear medicine patients. 2. To determine the absorbed dose and the number of radiation-induced foci in lymphocytes by sampling blood from patients after radiopeptide therapy with Lu-177 and radioiodine therapy with I-131. 3. To describe comprehensively the temporal and dose-dependent behavior of the DNA damage focus assay in radiation treatment-naive patients after their first radionuclide therapy using the results of the in-vitro calibration. For the in-vitro calibration with I-131 and Lu-177 blood samples For the in-vitro calibration with I-131 and Lu-177 blood samples were drawn from volunteers. Different activity concentrations were added to the samples for achieving absorbed doses up to 100mGy. As a result it was shown that the number of radiation-induced foci were linearly dependent of the absorbed dose. This is the same result that has been shown after external irradiation. The patient studies addressed the relationship between the absorbed dose to the blood and the number and temporal behavior of radiation-induced DNA double strand breaks in peripheral blood samples under radiopeptide therapy and under radioiodine therapy. The average number of radiation-induced foci showed a linear dose-response relationship within the first hours after administration of the radiopharmaceutical. The slope of the in-vitro calibration curve was in good agreement with the slopes of the linear functions fitted to the in-vivo data for Lu-177 and I-131. Later time points were characterized by a diminishing number of radiation-induced foci which was in accordance with the progression of DNA repair and the declining dose rates. Most patients treated with I-131 exceeded 20mGy in the first hour and in these patients the onset of a fast repair component was observed. With the experimental results and model calculations presented in this work, for the first time a dose-response relationship and a description of the time course of the in-vitro and in-vivo damage response after internal irradiation of beta-emitters could be established. KW - DNS-Doppelstrangbruch KW - gamma-H2AX KW - 53BP1 KW - DNA Doppelstrangbrüche KW - Dosimetrie KW - Medizinphysik KW - Radionuklidtherapie KW - Nuklearmedizin KW - DNA double strand breaks KW - dosimetry KW - medical physics KW - radionuclide therapy KW - nuclear medicine KW - Dosimetrie KW - Radionuklid KW - Therapie Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-120440 ER - TY - THES A1 - Schumann, Sarah T1 - Zeit- und Dosisabhängigkeit von DNA-Schäden induziert durch interne Bestrahlung mit unterschiedlichen Radionukliden T1 - Time and dose dependence of DNA damage induced by internal irradiation with various radionuclides N2 - In der Nuklearmedizin werden radioaktive Substanzen eingesetzt, um zu therapeutischen Zwecken gezielt bösartiges Gewebe zu zerstören oder in diagnostischen Anwendungen Stoffwechselvorgänge bildlich darzustellen. Die ionisierende Strahlung der eingesetzten Radionuklide kann jedoch auch DNA-Schäden in gesunden Zellen verursachen. DNA-Doppelstrangbrüche gehören dabei zu den kritischsten Läsionen, da sie schwer zu reparieren sind und eine fehlerhafte Reparatur zu Mutationen oder zum Zelltod führen kann. Während Radionuklidtherapien ist daher in Risikoorganen darauf zu achten, dass die deponierte Energie pro Masse, die Energiedosis, bestimmte Werte nicht überschreitet. Zu diesen Risikoorganen gehört auch das blutbildende System. Da eine Abschätzung der Energiedosis im Knochenmark häufig über die Bestimmung der Energiedosis im Blut als Surrogat erfolgt, ist deren Kenntnis von besonderem Interesse. In dieser Arbeit wurden daher Berechnungen der Energiedosis im Blut nach interner Bestrahlung durchgeführt und die Ergebnisse mit der Anzahl an strahlungsinduzierten DNA-Doppelstrangbrüchen in PBMCs korreliert. Zur Quantifizierung der DNA-Schäden wurden die Biomarker \(\gamma\)-H2AX und 53BP1 verwendet, die nach Entstehung eines Doppelstrangbruchs um diesen akkumulieren und sich durch Immunfluoreszenzfärbung als mikroskopische Foci sichtbar machen und quantifizieren lassen. Dadurch ermöglicht der \(\gamma\)-H2AX+53BP1-Assay einen quantitativen Nachweis strahlungsinduzierter Doppelstrangbrüche. Somit konnten im Rahmen dieser Arbeit neue Kenntnisse über die Dosisabhängigkeit von DNA-Schäden in PBMCs während interner Bestrahlung mit unterschiedlichen Radionukliden sowohl ex vivo als auch in vivo gewonnen werden. Ex-vivo-Untersuchungen haben den Vorteil, dass sie unter gleichbleibenden, gut definierten Bedingungen durchgeführt werden können und somit eine Analyse der Induktion von Doppelstrangbrüchen bei festgelegten Energiedosen und einer konstanten Bestrahlungsdauer erlauben. In dieser Arbeit wurden Blutproben von gesunden Versuchspersonen durch Zugabe von Radionukliden in bestimmten Aktivitätskonzentrationen eine Stunde lang intern bestrahlt. Für die Bestrahlung wurden die \(\alpha\)-Emitter \(^{223}\)Ra und \(^{224}\)Ra, die \(\beta\)\(^{-}\)-Emitter \(^{177}\)Lu und \(^{90}\)Y, der \(\beta\)\(^{+}\)-Emitter \(^{68}\)Ga und der \(\gamma\)-Emitter \(^{99m}\)Tc verwendet. Der untersuchte Energiedosisbereich lag zwischen 5 mGy und 136 mGy. Nach der Bestrahlung von Blutproben mit \(\beta\)- beziehungsweise \(\gamma\)-Emittern wurde beobachtet, dass die Anzahl der strahlungsinduzierten \(\gamma\)-H2AX+53BP1-Foci (RIF) in den PBMCs linear mit der Energiedosis im Blut ansteigt. Zudem zeigte sich, dass die Induktion der RIF unabhängig vom verwendeten Radionuklid und unabhängig von der Versuchsperson ist. Nach der Bestrahlung von Blutproben mit \(\alpha\)-Emittern waren zusätzlich zu den nach Expositionen mit \(\beta\)- beziehungsweise \(\gamma\)-Emittern beobachteten kleinen, runden Foci auch \(\gamma\)-H2AX+53BP1 enthaltende Spuren \(\alpha\)-Spuren) in den Zellkernen erkennbar, welche die Trajektorien der emittierten \(\alpha\)-Teilchen darstellten. Es konnte gezeigt werden, dass die Anzahl dieser \(\alpha\)-Spuren linear mit der Energiedosis im Blut zunimmt und damit ein geeigneter Parameter für die Biodosimetrie nach Expositionen mit \(\alpha\)-emittierenden Radionukliden ist. Auch in vivo wurde die Dosisabhängigkeit der DNA-Doppelstrangbrüche während der internen Bestrahlung durch Radionuklide mit unterschiedlichen Emissionseigenschaften untersucht. Aufgrund der neuen, vielversprechenden Entwicklungen von Radiopharmaka zur Therapie und Diagnostik des Prostatakarzinoms in den letzten Jahren wurden dafür Blutproben von Prostatakarzinom-Patienten während Therapie mit [\(^{177}\)Lu]Lu-PSMA I&T, während PET/CT-Diagnostik mit [\(^{68}\)Ga]Ga-PSMA I&T und während Therapie mit [\(^{223}\)Ra]RaCl\(_2\) untersucht. Während Therapie mit [\(^{177}\)Lu]Lu-PSMA I&T zeigte sich, dass die Anzahl der RIF in den ersten Stunden nach Therapiebeginn durch eine lineare Anpassungskurve angenähert werden kann, die mit der Energiedosis im Blut ansteigt, gefolgt von einem Rückgang der RIF zu späteren Zeitpunkten, der durch die DNA-Reparatur erklärt werden kann. Die gesamte Energiedosis im Blut lag im Mittel bei (109 \(\pm\) 28) mGy. Der linear dosisabhängige Anstieg der RIF zu Therapiebeginn gleicht der dosisabhängigen Induktion der RIF ex vivo nach Bestrahlung mit \(\beta\)- und \(\gamma\)-emittierenden Radionukliden und kann gut mit der entsprechenden Ex-vivo-Kalibrierkurve beschrieben werden. Zu späteren Zeitpunkten (48 h und 96 h nach Verabreichung) konnte in dieser Arbeit eine lineare Korrelation zwischen der Anzahl der noch verbleibenden RIF und der Dosisleistung nachgewiesen werden. Eine signifikante Korrelation der Anzahl der RIF 96 h nach Verabreichung mit dem PSA-Wert deutet zudem darauf hin, dass ein Zusammenhang mit klinischen Parametern besteht. Ein signifikanter Anstieg der \(\gamma\)-H2AX+53BP1-Foci konnte auch nach Verabreichung von [\(^{68}\)Ga]Ga-PSMA I&T für diagnostische PET/CT-Untersuchungen beobachtet werden, obwohl die Energiedosen im Blut bis zum PET/CT-Scan nur < 3 mGy betrugen. Im Vergleich zur Ex-vivo-Kalibrierkurve war die Steigung der linearen Anpassungskurve in vivo im Bereich < 3 mGy in dieser Studie etwa um ein Zehnfaches höher, was auf eine mögliche Hypersensitivität im Niedrigdosisbereich hindeuten könnte. Der Beitrag der CT zur Energiedosis im Blut konnte durch Ex-vivo-Experimente auf etwa 12 mGy abgeschätzt werden. Auch während Therapie mit [\(^{223}\)Ra]RaCl\(_2\) lagen die berechneten Energiedosen im Blut im Niedrigdosisbereich < 17 mGy. Trotzdem konnten in dieser Studie erstmalig \(\alpha\)-Spuren in vivo nach der Verabreichung eines \(\alpha\)-emittierenden Radionuklids quantifiziert werden, deren Anzahl 3 h und 4 h nach Verabreichung des Radiopharmakons signifikant erhöht war. Auch zu späten Zeitpunkten, bis vier Wochen nach Therapiebeginn, waren noch \(\alpha\)-Spuren nachweisbar, was auf eine unvollständige Reparatur der komplexen, durch die \(\alpha\)-Teilchen induzierten DNA-Schäden hinweisen könnte. Leider erlaubte die geringe Anzahl an Patienten und Datenpunkten keine zuverlässigen Korrelationen mit der Energiedosis oder mit klinischen Parametern. Nachdem in dieser Arbeit gezeigt werden konnte, dass DNA-Schäden nach interner Bestrahlung mit \(\alpha\)-, \(\beta\)- und \(\gamma\)-emittierenden Radionukliden mit Hilfe des \(\gamma\)-H2AX+53BP1-Assays zuverlässig nachgewiesen und anhand der Schadensgeometrie unterschieden werden können, wäre es in Zukunft interessant, DNA-Schäden auch nach Bestrahlung mit Radionuklidgemischen zu untersuchen. Dies könnte sowohl im Hinblick auf den Nachweis von Inkorporationen bei Strahlenunfällen hilfreich sein als auch zu einem besseren Verständnis der Effekte bei Behandlungen mit Radionuklidgemischen beitragen, welche vielversprechende Möglichkeiten für nuklearmedizinische Therapien bieten. Zudem zeigen die Ergebnisse dieser Arbeit, dass insbesondere im für die Diagnostik relevanten Bereich sehr niedriger Energiedosen < 10 mGy weiterer Forschungsbedarf besteht. Durch die Untersuchung der dosisabhängigen Reparatur der durch interne Bestrahlung induzierten DNA-Schäden könnte beispielsweise analysiert werden, ob die Reparaturfähigkeit im Niedrigdosisbereich eingeschränkt ist. Außerdem wäre es gerade im Bereich niedriger Dosen von Interesse, zu untersuchen, inwiefern Beobachtungen ex vivo das Verhalten in vivo geeignet repräsentieren. Um die erhöhten statistischen Unsicherheiten im Niedrigdosisbereich zu reduzieren, könnten zukünftig Verbesserungen auf dem Gebiet der automatisierten Auswertung der \(\gamma\)-H2AX+53BP1 enthaltenden Foci und Spuren hilfreich sein. Weitere Ziele zukünftiger Forschungsvorhaben könnten gezielte Untersuchungen zu Korrelationen zwischen der dosisabhängigen Induktion und Reparatur von DNA-Schäden und klinischen Parametern sowie die Analyse von DNA-Schäden während mehrerer Therapiezyklen darstellen. In Zusammenhang mit der Analyse klinischer Parameter wäre es denkbar, dass biodosimetrische Auswertungen zukünftig auch zur personalisierten Therapieplanung oder auch zur Vorhersage des Therapieerfolgs dienen und somit langfristig zu einer Optimierung nuklearmedizinischer Therapien beitragen könnten. N2 - In nuclear medicine, radioactive substances are applied for therapeutic purposes to destroy malignant tissue, or in diagnostic applications to visualize metabolic processes. However, the ionizing radiation of the applied radionuclides can also cause DNA damage in healthy cells. Among these, DNA double-strand breaks belong to the most critical lesions because they are difficult to repair and misrepair can lead to mutations or cell death. Therefore, during radionuclide therapies, it is of great importance to ensure that the deposited energy per mass, the absorbed dose, does not exceed certain values in organs at risk. One of these organs at risk is the hematopoietic system. As the absorbed dose to the bone marrow is often estimated by determining the absorbed dose to the blood as a surrogate, knowledge of the latter is of particular interest. Therefore, in this thesis, calculations of the absorbed dose to the blood after internal irradiation were performed and the results were correlated with the number of radiation-induced DNA double-strand breaks in PBMCs. To quantify DNA damage, the biomarkers \(\gamma\)-H2AX and 53BP1 were used, which accumulate around a double-strand break after its formation and which can be visualized and quantified as microscopic foci by immunofluorescence staining. Consequently, the \(\gamma\)-H2AX+53BP1 assay allows a quantitative detection of radiation-induced double-strand breaks. Thus, by combining absorbed dose calculations with a quantitative analysis of DNA damage in PBMCs during internal irradiation with various radionuclides both ex vivo and in vivo, new knowledge was gained in the context of this work. Ex-vivo examinations have the advantage that they can be carried out under constant, well-defined conditions and thus allow an analysis of the induction of double-strand breaks at preset absorbed doses and a constant irradiation duration. In this work, blood samples from healthy test persons were internally irradiated for one hour by adding radionuclides at defined activity concentrations. For the irradiation, the \(\alpha\)-emitters \(^{223}\)Ra and \(^{224}\)Ra, the \(\beta\)\(^{-}\)-emitters \(^{177}\)Lu and \(^{90}\)Y, the \(\beta\)\(^{+}\)-emitter \(^{68}\)Ga and the \(\gamma\)-emitter \(^{99m}\)Tc were used. The absorbed dose ranged from 5 mGy to 136 mGy. After irradiating blood samples with \(\beta\)- and \(\gamma\)-emitters, it was observed that the number of radiation-induced \(\gamma\)-H2AX+53BP1 foci (RIF) in the PBMCs increases linearly with the absorbed dose to the blood. Furthermore, it was shown that the induction of RIF is independent of the radionuclide applied and the test person. After irradiating blood samples with \(\alpha\)-emitters, in addition to the small round foci observed after exposure to \(\beta\)- and \(\gamma\)-emitters, \(\gamma\)-H2AX+53BP1 containing tracks (\(\alpha\)-tracks) were visible in the nuclei, which represented the trajectories of the emitted \(\alpha\)-particles. It was shown that the number of these \(\alpha\)-tracks increases linearly with the absorbed dose to the blood and is, therefore, a suitable parameter for biodosimetry after exposure to \(\alpha\)-emitting radionuclides. The absorbed dose dependence of DNA double-strand breaks during internal irradiation with radionuclides with different emission properties was also investigated in vivo. Due to the promising new developments of radiopharmaceuticals for therapy and diagnostics of prostate cancer in recent years, blood samples from prostate cancer patients were examined during therapy with [\(^{177}\)Lu]Lu-PSMA I&T, during PET/CT diagnostics with [\(^{68}\)Ga]Ga-PSMA I&T and during therapy with [\(^{223}\)Ra]RaCl\(_2\). During therapy with [\(^{177}\)Lu]Lu-PSMA I&T, it was shown that the number of RIF in the first hours after therapy start can be approximated by a linear fitting curve, which increases with the absorbed dose to the blood, followed by a decrease in RIF at later time points, which can be explained by DNA repair. The total absorbed dose to the blood was (109 \(\pm\) 28) mGy on average. The linear absorbed dose-dependent increase in RIF at the beginning of therapy is similar to the absorbed dose-dependent induction of RIF ex vivo after irradiation with \(\beta\)- and \(\gamma\)-emitting radionuclides and can be well described with the corresponding ex-vivo calibration curve. At later time points (48 h and 96 h after administration), a linear correlation between the number of remaining RIF and the dose rate was demonstrated in this work. A significant correlation of the number of RIF 96 h after administration with PSA levels also suggests a link to clinical parameters. A significant increase in \(\gamma\)-H2AX+53BP1 foci was also observed after administration of [\(^{68}\)Ga]Ga-PSMA I&T for diagnostic PET/CT examinations, despite the fact that absorbed doses to the blood were only < 3 mGy by the time of the PET/CT scan. Compared to the ex-vivo calibration curve, the slope of the linear in-vivo fitting curve in the range < 3 mGy in this study was approximately ten times higher, which may indicate a possible hypersensitivity in the low dose range. The contribution of the CT to the absorbed dose to the blood was estimated at approximately 12 mGy by ex-vivo experiments. During therapy with [\(^{223}\)Ra]RaCl\(_2\), the calculated absorbed doses to the blood were also in the low dose range < 17 mGy. Nevertheless, this study was the first to quantify \(\alpha\)-tracks in vivo after the administration of an \(\alpha\)-emitting radionuclide, with a significantly increased number of \(\alpha\)-tracks 3 h and 4 h after administration of the radiopharmaceutical. Even at late time points, up to four weeks after therapy start, \(\alpha\)-tracks were still detectable, which could indicate incomplete repair of the complex DNA damage induced by \(\alpha\)-particles. Unfortunately, the small number of patients and data points did not allow reliable correlations with the absorbed dose or clinical parameters. In this thesis, it was shown that DNA damage after internal irradiation with \(\alpha\)-, \(\beta\)- and \(\gamma\)-emitting radionuclides can be reliably detected by applying the \(\gamma\)-H2AX+53BP1 assay and distinguished by damage geometry. For future work, it would be of interest to additionally investigate DNA damage after irradiation with mixtures of radionuclides. This could be helpful for the detection of incorporations after radiation accidents, and could also contribute to a better understanding of the effects of therapeutic applications of radionuclide mixtures, which offer promising opportunities for nuclear medicine therapies. Furthermore, the results of this work show that there is need for further research, especially in the very low dose range < 10 mGy, which is relevant for diagnostics. By investigating the absorbed dose-dependent repair of DNA damage induced by internal irradiation, for example, it could be analyzed whether the repair capability is limited in the low dose range. Particularly in the range of low doses, it would also be of interest to investigate to what extent observations ex vivo adequately represent the behavior in vivo. In order to reduce the increased statistical uncertainties in the low dose range, future improvements in the field of automated evaluation of \(\gamma\)-H2AX+53BP1 containing foci and tracks could be helpful. Further objectives of future research projects could be investigations focussing on correlations between the absorbed dose-dependent induction and repair of DNA damage and clinical parameters as well as an analysis of DNA damage over several therapy cycles. In the context of the analysis of clinical parameters, it is conceivable that biodosimetric assessments could enhance personalized treatment planning or the prediction of therapy success, thus contributing, in the long-term, to an optimization of nuclear medicine therapies. KW - Nuklearmedizin KW - Dosimetrie KW - Radionuklid KW - DNS-Doppelstrangbruch KW - Biomarker KW - Medizinphysik KW - gamma-H2AX KW - 53BP1 KW - nuclear medicine KW - dosimetry KW - radionuclide KW - DNA damage KW - medical physics Y1 - 2022 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-223904 ER - TY - THES A1 - Portmann, Johannes T1 - Accelerated inversion recovery MRI of the myocardium using spiral acquisition T1 - Beschleunigte Inversion-Recovery MR-Bildgebung des Myokards mit spiralen Auslesezügen N2 - This work deals with the acceleration of cardiovascular MRI for the assessment of functional information in steady-state contrast and for viability assessment during the inversion recovery of the magnetization. Two approaches are introduced and discussed in detail. MOCO-MAP uses an exponential model to recover dynamic image data, IR-CRISPI, with its low-rank plus sparse reconstruction, is related to compressed sensing. MOCO-MAP is a successor to model-based acceleration of parametermapping (MAP) for the application in the myocardial region. To this end, it was augmented with a motion correction (MOCO) step to allow exponential fitting the signal of a still object in temporal direction. Iteratively, this introduction of prior physical knowledge together with the enforcement of consistency with the measured data can be used to reconstruct an image series from distinctly shorter sampling time than the standard exam (< 3 s opposed to about 10 s). Results show feasibility of the method as well as detectability of delayed enhancement in the myocardium, but also significant discrepancies when imaging cardiac function and artifacts caused already by minor inaccuracy of the motion correction. IR-CRISPI was developed from CRISPI, which is a real-time protocol specifically designed for functional evaluation of image data in steady-state contrast. With a reconstruction based on the separate calculation of low-rank and sparse part, it employs a softer constraint than the strict exponential model, which was possible due to sufficient temporal sampling density via spiral acquisition. The low-rank plus sparse reconstruction is fit for the use on dynamic and on inversion recovery data. Thus, motion correction is rendered unnecessary with it. IR-CRISPI was equipped with noise suppression via spatial wavelet filtering. A study comprising 10 patients with cardiac disease show medical applicability. A comparison with performed traditional reference exams offer insight into diagnostic benefits. Especially regarding patients with difficulty to hold their breath, the real-time manner of the IR-CRISPI acquisition provides a valuable alternative and an increase in robustness. In conclusion, especially with IR-CRISPI in free breathing, a major acceleration of the cardiovascular MR exam could be realized. In an acquisition of less than 100 s, it not only includes the information of two traditional protocols (cine and LGE), which take up more than 9.6 min, but also allows adjustment of TI in retrospect and yields lower artifact level with similar image quality. N2 - Diese Arbeit behandelt die Beschleunigung der kardiovaskulären MRT zum Erfassen funktioneller Information bei Steady-State-Kontrast und zur Unter- suchung der Vitalität bei Wiederherstellung der Magnetisierung nach ihrer Inversion. Zwei Ansätze werden eingeführt und im Detail diskutiert: MOCO- MAP, welches ein exponentielles Modell nutzt, um dynamische Daten zu rekonstruieren, und IR-CRISPI, welches mit seinem “low-rank plus sparse"- Algorithmus mit Compressed Sensing verwandt ist. MOCO-MAP ist der Nachfolger der modellbasierten Beschleunigung des Parameter-Mappings (MAP) für die Anwendung im Bereich des Myokards. Hierzu wurde es mit einer Bewegungskorrektur (MOCO) versehen, um expo- nentielles Fitten eines unbewegten Objects in Zeitrichtung zu ermöglichen. Das Einbringen dieses physikalischen Vorwissens zusammen mit dem Erzwin- gen von Konsistenz mit den Messdaten wird dazu genutzt, iterativ eine Bildfolge aus Daten einer deutlich kürzeren Messung als herkömmlich zu rekonstruieren (< 3 s gegenüber ca. 10 s). Die Ergebnisse zeigen die Umsetz- barkeit der Methode sowie die Nachweisbarkeit von Delayed Enhancements im Myokard, aber deutliche funktionelle Abweichungen und Artefakte bereits aufgrund von kleinen Ungenauigkeiten der Bewegungskorrektur. IR-CRISPI geht aus CRISPI hervor, welches zur Auswertung von funk- tionellen Echtzeitdaten bei konstantem Kontrast dient. Mit der Rekon- struktion durch getrennte Berechnung von niedrigrangigem und dünnbe- setztem Matrixanteil wird hier bei der Datenrekonstruktion weniger stark eingeschränkt als bei einem strikten exponentiellen Modell. Die pirale Auf- nahmeweise erlaubt hierzu ausreichend effiziente k-Raumabdeckung. Die “low-rank plus sparse"-Rekonstruktion ist kompatibel mit dynamischen und mit Inversion-Recovery-Daten. Eine Bewegungskorrektur ist folglich nicht nötig. IR-CRISPI wurde mit einer Rauschunterdrückung durch räumliche Wavelet- Filterung versehen. Eine Studie, die 10 Patienten einschließt, zeigt die Eignung für die medizinische Anwendung. Der Vergleich mit herkömm- lichen Aufnahmetechniken lässt auf den gewonnenen diagnostischen Nutzen schließen. Besonders für Patienten, die Schwierigkeiten mit dem Luftanhal- ten haben, eröffnet diese Echtzeitaufnahmemethode eine wertvolle Alterna- tive und erhöhte Stabilität. Am Ende konnte gerade mittels IR-CRISPI eine bemerkenswerte Beschleu- nigung der kardiovaskulären MR-Untersuchung verwirklicht werden. Trotz der kurzen Aufnahmezeit von weniger als 100 s für den kompletten linken Ven- trikel schließt es nicht nur die Information zweier herkömmlicher Protokolle mit ein (Cine und LGE), die zusammen mehr als 9,6 min dauern, sondern es erlaubt zusätzlich auch das Einstellen der TI-Zeit im Nachhinein und liefert Ergebnisse mit geringerem Artefaktlevel bei ähnlicher Bildqualität KW - Kernspintomografie KW - Herzfunktion KW - Herzmuskel KW - Bildgebendes Verfahren KW - Echtzeit KW - cine loop KW - late enhancement KW - late gadolinium-enhancement KW - magnetic resonance imaging KW - real-time imaging KW - spiral trajectory Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-302822 ER - TY - THES A1 - Beykan, Seval T1 - Implementation and Optimization of Dosimetry for Theranostics in Radiopeptide Therapies T1 - Implementierung und Optimierung der Dosimetrie für die Theranostik in Radiopeptidtherapien N2 - Peptide receptor radionuclide therapy (PRRT) is a molecular targeted radiation therapy involving the systemic administration of radiolabeled somatostatin receptor binding peptides designed to target with high affinity and specificity receptors overexpressed on tumors. Peptides are applied which either target as agonist (with internalization) or antagonist (little to no internalization). Recently, two novel antagonistic agents have been developed for clinical use: OPS202 and OPS201. 68Ga-labelled OPS202 is used for diagnostic purposes with positron emission tomography and 177Lu-labelled OPS201 is used for the therapy in patients with neuroendocrine tumors (NETs). Both agents are presently under clinical evaluation. Despite the very low internalization rate, the use of somatostatin receptor antagonists which target more binding sites on receptors are expected to result in higher specificity, more favorable pharmacokinetics and higher tumor retention and better visualization than the agonists. The main goal of this thesis was analyzing the biodistribution, biokinetics and internal dosimetry of the recently developed somatostatin receptor antagonists (OPS201 and OPS202) for therapeutic and diagnostic purposes in different species (mice, pigs and patients). In addition, an analysis of the influence of image quantification and the integration of time activity curves on kidney dosimetry in a pig model was carried out. Furthermore, extrapolation methods, which are used for predicting organ absorbed doses for humans based on preclinical animal models, were systematically compared for blood, liver, and kidneys of OPS201 injected species. Based on the OPS202 injected patients’ investigations, 68Ga-OPS202 shows promising biodistribution and imaging properties with tumor contrast which is optimal one hour after injection of the radiotracer. OPS202 is well tolerated and delivers absorbed doses to organs that are lower than those by 18F-FDG and similar to other 68Ga-labeled somatostatin receptor ligands. As a result of 68Ga OPS202 injection, the highest absorbed doses were observed in the urinary bladder (0.10 mGy/MBq) and kidneys (0.84 mGy/MBq). The calculated mean effective dose coefficient of 68Ga-OPS202 injected patients was 0.024 mSv/MBq (3.6 mSv for 150 MBq 68Ga-OPS202 injection) which is similar to other 68Ga-labeled compounds. Based on the OPS201 biokinetics and dosimetry investigations, after the injection of 177Lu-OPS201, a fast blood clearance of the compound is observed in the first phase (half-life: 1.83 h) for each species. 10 min after injection, less than 5% of the injected activity per milliliter of blood circulates in pigs and humans. The analysis of the mice, pig and preliminary patient data provides evidence that, patients enrolled in a phase 1 177Lu-OPS201 trial would not be at risk of overexposure. Based on our results, for 177Lu labelled studies, late time points after 72 h have a great impact on absorbed dose calculations. That is why follow-up times especially at late time points (more than 72 h) are required for the time-integrated activity coefficient (TIAC) calculations in order to represent the area under the curve appropriately and to analyze both biokinetics and dosimetry accurately. In addition, to find the most adequate extrapolation methods that minimize the interspecies differences of dosimetry data, several extrapolation methods from animal to human have been tested. For OPS201 time scaling or combination of relative mass and time scaling results in most similar TIAC values, if the organ mass ratios between the species are high. In time scaling, the scan/sampling time is scaled by using the ratio of the whole body masses of the respective species. In relative mass scaling, the TIACs are scaled based on the ratio of the whole body and organ mass of respective species. Other methods tested showed higher deviations. For the study on the influence of image quantification and the choice of the optimal scanning time points, a study in a pig model, which was performed in collaboration with Aalborg University and Octreopharm Sciences GmbH, was reanalyzed. As kidneys are organs-at-risk in PRRT with 177Lu labelled peptides, several quantification methods, based on 2D and 3D quantitative imaging were chosen. For this purpose, a 3D printed pig kidney phantom was prepared and measured with/without background activities representing the activities in the pig SPECT/CT scans. The phantom dosimetry data based on multiple SPECT/CT images and based on multiple planar images in combination with one SPECT/CT scan (MP1S Imaging) were compared to the pig dosimetry. The calculated TIACs of the phantom with background based on multiple SPECT/CT and MP1S imaging were quite similar to the multiple SPECT/CT based pig TIAC. In addition, in order to investigate the effect of late time points on dosimetry and absorbed dose values in 177Lu therapies, the difference, associated with eliminating the late two scan time points, on the TIACs was analyzed. When the TIACs (including all time points) of the pig based on multiple SPECT/CT and MP1S imaging were investigated, the use of MP1S imaging results in considerably lower TIAC values to the kidney (by a factor of 1.4). With eliminating late time points from the created time activity curve, the factor increases up to 2.4 times with a corresponding increase in TIAC uncertainties. As a consequence, further evaluation of 68Ga-OPS202 for PET/CT imaging and 177Lu-OPS201 for the treatments of NET patients is necessary. In particular, a head-to-head comparison of agonists and OPS peptides with respect to biokinetics, biodistribution and dosimetry would be helpful. In addition, the influence of the late scan time points on dosimetry needs further attention in particular for kidney dosimetry N2 - Die Peptidrezeptor-Radionuklidtherapie (PRRT) beinhaltet die systemische Verabreichung von radioaktiv markierten Somatostatinrezeptor-bindende Peptiden. Sie zielt darauf ab, Rezeptoren, die in Tumoren überexprimiert sind, mit hoher Affinität und Spezifität anzusprechen. Es werden Peptide eingesetzt, die entweder als Agonist (mit Internalisierung) oder Antagonist (wenig bis gar keine Internalisierung) wirken. Vor kurzem wurden zwei neue antagonistische Wirkstoffe für den klinischen Einsatz entwickelt: OPS202 und OPS201. 68Ga markiertes OPS202 wird für diagnostische Zwecke mit der Positronen-Emissions-Tomographie und 177Lu markiertes OPS201 für die Therapie von Patienten mit neuroendokrinen Tumoren (NETs) verwendet. Beide Wirkstoffe befinden sich derzeit in der klinischen Erprobung. Trotz der sehr niedrigen Internalisierungsrate wird erwartet, dass der Einsatz von Somatostatinrezeptor-Antagonisten, die mehr Bindungsstellen an Rezeptoren ansprechen, zu einer höheren Spezifität, einer günstigeren Pharmakokinetik und einer höheren Tumorretention und besseren Visualisierung als die Agonisten führt. Das Hauptziel dieser Arbeit war die Analyse der Biodistribution, Biokinetik und der internen Dosimetrie der neu entwickelten Somatostatinrezeptor-Antagonisten (OPS201 und OPS202) für therapeutische und diagnostische Zwecke in verschiedenen Spezies (Mäuse, Schweine und Patienten). Darüber hinaus wurde eine Analyse des Einflusses der Bildquantifizierung und der Integration von Zeitaktivitätskurven auf die Nierendosimetrie in einem Schweinemodell durchgeführt. Zudem wurden Extrapolationsmethoden, die zur Vorhersage der Energiedosen für das Blut, die Leber und die Nieren für den Menschen auf der Grundlage präklinischer Tiermodelle, die mit OPS201 injiziert wurden, systematisch verglichen. Basierend auf den Patientenuntersuchungen mit OPS202 zeigt 68Ga-OPS202 vielversprechende Biodistributions- und Abbildungseigenschaften mit einem Tumorkontrast, der eine Stunde nach Injektion des Radiotracers optimal ist. OPS202 ist gut verträglich; die Energiedosen in den Organen sind niedriger als die von 18F-FDG und ähnlich wie andere 68Ga-markierte Somatostatinrezeptorliganden. Nach einer Injektion von OPS202, das mit 68Ga markiert wurde, wurden die höchsten Energiedosen in der Harnblase (0.10 mGy/MBq) und den Nieren (0.84 mGy/MBq) beobachtet. Der berechnete mittlere effektive Dosiskoeffizienten von Patienten, die mit 68Ga-OPS202 injiziert wurden, betrug 0.024 mSv/MBq (3.6 mSv für 150 MBq 68Ga-OPS202), ähnlich wie bei anderen 68Ga-markierten Verbindungen. Basierend auf den biokinetischen und dosimetrischen Untersuchungen von OPS201 wird nach der Injektion von 177Lu-OPS201 in der ersten Phase (Halbwertszeit: 1.83 h) für jede Spezies eine schnelle Ausscheidung der Verbindung beobachtet. 10 Minuten nach der Injektion zirkulieren weniger als 5% der injizierten Aktivität pro Milliliter Blut bei Schweinen und Menschen. Die Analyse der Daten von Mäusen, Schweinen und vorläufigen Patienten liefert Hinweise darauf, dass Patienten, die in eine 177Lu-OPS201-Studie aufgenommen werden, nicht dem Risiko für eine Überexposition ausgesetzt wären. Basierend auf unseren Ergebnissen werden für 177Lu markierte Studien Nachbeobachtungszeiten insbesondere zu späten Zeitpunkten (mehr als 72 h) für die Berechnungen des zeitintegrierten Aktivitätskoeffizienten (TIAC) benötigt, um die Fläche unter der Kurve angemessen darzustellen und sowohl die Biokinetik als auch die Dosimetrie genau zu analysieren. Späte Zeitpunkte (nach 72 h) haben einen großen Einfluss auf die Berechnung der Energiedosis. Darüber hinaus wurden mehrere Extrapolationsmethoden vom Tier auf den Menschen getestet, um die geeignetsten Extrapolationsmethoden zu finden, die die Unterschiede zwischen den verschiedenen Spezies von Dosimetrie-Daten minimieren. Für OPS201 ergibt die Zeitskalierung oder die Kombination von relativer Masse und Zeitskalierung die ähnlichsten TIAC-Werte, wenn die Organmassenverhältnisse zwischen den Spezies hoch sind. Bei der Zeitskalierung wird die Scan-/Samplingzeit durch das Verhältnis der Ganzkörpermassen der jeweiligen Spezies skaliert. Bei der relativen Massenskalierung werden die TIACs basierend auf dem Verhältnis der Ganzkörper- und Organmasse der jeweiligen Spezies skaliert. Andere getestete Methoden zeigten höhere Abweichungen. Um den Einfluss der Bildquantifizierung und die Wahl der optimalen Scanzeitpunkte zu untersuchen, wurde eine Studie in einem Schweinemodell, die in Zusammenarbeit mit der Universität Aalborg und der Octreopharm Sciences GmbH durchgeführt wurde, neu analysiert. Da die Nieren bei PRRT mit 177Lu markierten Peptiden Risikoorgane sind, wurden mehrere Quantifizierungsmethoden ausgewählt, die auf 2D- und 3D-Bildgebung basieren. Zu diesem Zweck wurde ein 3D gedrucktes Schweine-Nierenphantom vorbereitet und, mit und ohne Hintergrundaktivitäten, die den Aktivitäten in den Schweinescans entsprechen, gemessen und quantifiziert,. Dosimetrie-Daten, die aus dem Schweinescan basierend auf mehreren 3D-Bildern und basierend auf mehreren 2D-Planarbildern in Kombination mit einem SPECT/CT-Bild („MP1S-Imaging“) gewonnen wurden, wurden mit den Ergebnissen der Phantomscans verglichen. Die so ermittelten TIACs des Phantoms mit Hintergrund, basierend auf beiden Bildgebungstechniken, entsprachen in etwa den Ergebnissen derjenigen Schweinedaten, die auf mehrfachen SPECT/CT-Aufnahmen basierten. Um die Auswirkungen der späten Zeitpunkte auf die Dosimetrie und die Werte der Energiedosen in 177Lu Therapien zu untersuchen, wurde außerdem der Unterschied, der mit der Eliminierung der späten zwei Scanzeitpunkte verbunden ist, auf die TIACs analysiert. Wenn auf mehreren SPECT/CT- und Hybrid-Bildern basierten TIACs des Schweins untersucht wurden, war die berechnete TIAC (einschließlich aller Zeitpunkte) basierend auf mehreren SPECT/CT-Bildern im Vergleich zur Hybrid Imaging um den Faktor 1.4 höher. Durch die Eliminierung von späten Zeitpunkten aus der erstellten Zeitaktivitätskurve erhöht sich der TIAC um den Faktor 2.4 mit entsprechend höheren TIAC Unsicherheiten. Daher ist zu folgern, dass eine weitere Evaluierung von 68Ga-OPS202 für die PET/CT-Bildgebung und 177Lu-OPS201 für die Behandlung von NET-Patienten erforderlich ist. Insbesondere wäre ein direkter Vergleich von Agonisten und OPS-Peptiden in Bezug auf Biokinetik, Biodistribution und Dosimetrie hilfreich. Darüber hinaus bedarf der Einfluss der späten Zeitpunkte bei Dosimetrie-Scans weiterer Aufmerksamkeit, insbesondere bei der Nierendosimetrie. KW - biodistribution KW - biokinetics KW - internal dosimetry KW - somatostatin receptor antagonists KW - 177Lu-OPS201 KW - therapy KW - 68Ga-OPS202 KW - diagnostics Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-199553 ER - TY - THES A1 - Mendes Pereira, Lenon T1 - Morphological and Functional Ultrashort Echo Time (UTE) Magnetic Resonance Imaging of the Human Lung T1 - Morphologische und funktionelle Magnetresonanztomographie der menschlichen Lunge mit ultrakurzen Echozeiten (UTE) N2 - In this thesis, a 3D Ultrashort echo time (3D-UTE) sequence was introduced in the Self-gated Non-Contrast-Enhanced Functional Lung Imaging (SENCEFUL) framework. The sequence was developed and implemented on a 3 Tesla MR scanner. The 3D-UTE technique consisted of a nonselective RF pulse followed by a koosh ball quasi-random sampling order of the k-space. Measurements in free-breathing and without contrast agent were performed in healthy subjects and a patient with lung cancer. A gating technique, using a combination of different coils with high signal correlation, was evaluated in-vivo and compared with a manual approach of coil selection. The gating signal offered an estimation of the breathing motion during measurement and was used as a reference to segment the acquired data into different breathing phases. Gradient delays and trajectory errors were corrected during post-processing using the Gradient Impulse Response Function. Iterative SENSE was then applied to determine the fully sampled data. In order to eliminate signal changes caused by motion, a 3D image registration was employed, and the results were compared to a 2D image registration method. Ventilation was assessed in 3D and regionally quantified by monitoring the signal changes in the lung parenchyma. Finally, image quality and quantitative ventilation values were compared to the standard 2D-SENCEFUL technique. 3D-UTE, combined with an automatic gating technique and SENCEFUL MRI, offered ventilation maps with high spatial resolution and SNR. Compared to the 2D method, UTE-SENCEFUL greatly improved the clinical quality of the structural images and the visualization of the lung parenchyma. Through‐plane motion, partial volume effects and ventilation artifacts were also reduced with a three-dimensional method for image registration. UTE-SENCEFUL was also able to quantify regional ventilation and presented similar results to previous studies. N2 - In dieser Arbeit wurde eine 3D-UTE (ultrashort echo time) Sequenz mit SENCEFUL-MRI kombiniert. Die Sequenz wurde für einen 3 T MR-Scanner entwickelt und implementiert. Die 3D-UTE-Technik bestand aus einem nichtselektiven HF- Impuls, gefolgt von einer quasi-zufälligen Abtastung des k-Raums. Messungen in freier Atmung und ohne Kontrastmittel wurden bei gesunden Probanden und einem Patienten mit Lungenkrebs durchgeführt. Zur Zuordnung der Daten zu verschiedene Atemphasen wurde eine Technik verwendet, die verschiedene Spulen mit hoher Signalkorrelation kombiniert. Die Ergebnisse wurden in einer in-vivo Messung bewertet und mit einem manuellen Ansatz der Spulenselektion verglichen. Die Technik ermöglichte eine Visualisierung der Atembewegung und wurde als Referenz verwendet, um die erfassten Daten in mehrere Atemphasen zu segmentieren. Gradientenverzögerungen und Trajektorienfehler wurden mit der "Gradient Impulse Response Function - GIRF" korrigiert. Bei der Bildrekonstruktion kam Iteratives SENSE zum Einsatz. Eine 3D-Bildregistrierung erlaubte es, Signaländerungen durch Bewegung zu eliminieren. Es erfolgte ein Vergleich der Ergebnisse mit einem 2D- Bildregistrierungsverfahren. Die Lungenventilation wurde in 3D gemessen und anhand der Signaländerungen im Lungenparenchym quantifiziert. Schließlich, wurden die Werte für die Bildqualität und Lungenventilation mit der Standard-2D-SENCEFUL-Technik verglichen. Die 3D-UTE-Sequenz in Kombination mit einer automatischen Gating-Technik und SENCEFUL-MRI, ermöglichte die Akquise von Ventilationskarten mit hoher räumlicher Auflösung und SNR. Im Vergleich zur 2D-Methode, verbesserte UTE- SENCEFUL die klinische Qualität der Morphologischen Bilder. Bewegung, Partialvolumeneffekte und Ventilationsartefakte wurden ebenfalls mit einer dreidimensionalen Methode zur Bildregistrierung reduziert. Insgesamt konnten mit der 3D-UTE Technik die Ergebnisse vorangegangener Studien reproduziert und die Bildqualität verbessert werden. KW - Kernspintomografie KW - Lunge KW - MRI KW - Ultrashort echo time - UTE KW - Magnetic Resonance Imaging KW - Lung Y1 - 2019 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-183176 ER - TY - THES A1 - Salas Ramirez, Maikol T1 - Methods to Improve Bone Marrow Dosimetry in Molecular Radiotherapy T1 - Methoden zur Verbesserung der Knochenmarkdosimetrie in der molekularen Strahlentherapie N2 - Bone marrow dosimetry is a topic of high interest in molecular radiotherapy. Predicting the level of hematological toxicity is one of the most important goals of nuclear medicine radiation dosimetry. To achieve this, it is necessary to quantify the absorbed dose to the active bone marrow, thus aiming at administering the most efficient therapy with a minimum level of adverse effects in the patient. The anatomical complexity of trabecular bone and bone marrow leads to the need of applying non-nuclear medicine imaging methods for determining the spatial distribution of soft tissue, adipose tissue, and bone in spongiosa. Therefore, the two objectives of this dissertation are: i) to apply magnetic resonance imaging (MRI) for quantification of the fat volume fraction, and ii) to validate a method based on dual-energy quantitative computed tomography (DEQCT) for quantification of the trabecular bone volume fraction. In a first step, an MRI sequence (two-point Dixon) for fat-water separation was validated in a 3 Tesla system by quantifying the fat volume fraction in a phantom and the lumbar vertebrae of volunteers and comparing with magnetic resonance spectroscopy (MRS). After successful validation, the fat volume fraction was retrospectively measured in the five lumbar vertebrae of 44 patient images acquired in the clinical routine. The two-point Dixon showed a good quantification of the fat volume fraction in the phantom experiment (-9.8% maximum relative error with respect to the nominal values). In the volunteers, a non-significant difference between MRI and MRS was found for the quantification of the fat volume fraction in volumes-of-interest with similar dimensions and position in both quantification methodologies (MRI and MRS). In the study with patient data, the marrow conversion (red → yellow marrow) was found to be age-dependent, and slower in males (0.3% per year) than in females (0.5% per year). Also, considerable variability of the fat volume fraction in patients of similar ages and the same gender was observed. These results enable the use of two-point Dixon MRI in the quantification of the fat volume fraction in the bone marrow. Additionally, the constant marrow conversion during adulthood suggests that a patient-specific approach should replace the assumption of a constant cellularity volume fraction of 0.7 (reference man) (1,2) as proposed by the International Commission on Radiological Protection (ICRP). In a second step, a quantification method based on DEQCT was validated in two CT systems: i) a clinical CT integrated into a SPECT/CT and ii) a dual-source computed tomography (DSCT) system. The method was applied in two phantoms: the first was used to validate the DEQCT method by the quantification of the hydroxyapatite volume fraction in three vials of 50 ml each and three different hydroxyapatite concentrations (100 mg/cm3, 200 mg/cm3, 300 mg/cm3). The second phantom was the European spine phantom (ESP), an anthropomorphic spine phantom. It was used to quantify the bone mineral content (BMC) on the whole vertebra and the hydroxyapatite volume fraction (VFHA) in the spongiosa region of each vertebra of the phantom. Lastly, the BMC of lumbar vertebrae 1 (LV1) and 2 (LV2) was measured in a patient using DEQCT and dual-energy X-ray absorptiometry (DEXA). Furthermore, the hydroxyapatite volume fraction (VFHA) and the bone volume fraction (VFB) was calculated for both the whole vertebrae and the spongiosa region of LV1 and LV2. The measured and nominal hydroxyapatite volume fraction in the vial phantom showed a good correlation (maximum relative error: 14.2%). The quantification of the BMC on the whole vertebra and the VFHA on the spongiosa region showed larger relative errors than in the validation phantom. The quantification of BMC on LV1 and LV2 showed relative errors between DEXA and DSCT equal to 7.6% (LV1) and -8.4% (LV2). Also, the values of the VFHA (mineral bone) were smaller than the VFB. This result is consistent with the bone composition (mineral bone plus organic material). The DEQCT method enables the quantification of hydroxyapatite (mineral bone) and bone (mineral bone plus organic material) in a clinical setting. However, the method showed an overestimation of the quantified mineral bone volume fraction. This overestimation might be related to the lack of detailed information on the CT X-ray spectra and detector sensitivity. Also, the DEQCT method showed a dependency on the CT reconstruction kernel and the chemical description of the materials to be quantified. Based on the results of this work, the feasibility for quantifying the fat volume fraction and the bone volume fraction in the spongiosa in a clinical setting has been demonstrated/proven. Furthermore, the differences in fat volume fraction in females and males, as well as the variability of the fat volume fraction in subjects of similar ages, questions the approximation of the cellularity volume fraction by only a single ICRP reference value in bone marrow dosimetry for molecular radiotherapy. Lastly, this study presents the first approach for non-invasive quantification of the bone volume fraction (mineral bone plus organic material) for improved bone marrow dosimetry. N2 - Die Knochenmarkdosimetrie ist von großem Interesse für die Radionuklidtherapie. Die Vorhersage des Grades der hämatologischen Toxizität ist eines der wichtigsten Ziele der nuklearmedizinischen Dosimetrie. Um dieses Ziel zu erreichen, ist es erforderlich, die Energiedosis des aktiven Knochenmarks zu quantifizieren, um dem Patienten so eine möglichst effiziente Therapie mit einem minimalen Maß an unerwünschten Nebenwirkungen verabreichen zu können. Die anatomische Komplexität von Knochentrabekel und Knochenmark macht es erforderlich, nicht-nuklearmedizinische bildgebende Verfahren anzuwenden, um die räumliche Verteilung von Weichgewebe, Fettgewebe und Knochen in der Spongiosa zu bestimmen. Daher sind die zwei Ziele dieser Dissertation: i) die Anwendung der Magnetresonanztomographie (MRT) zur Quantifizierung des Fettvolumenanteils und ii) die Validierung einer auf der quantitativen Dual-Energy Computertomographie (engl. Dual-energy quantitative computed tomography, DEQCT) basierenden Methode zur Quantifizierung des Knochentrabekelvolumenanteils. In einem ersten Schritt wurde eine Zweipunkt-Dixon-Sequenz der MRT zur Fett-Wasser-Trennung in einem 3 Tesla-System validiert, indem der Fettvolumenanteil in einem Phantom und in den Lendenwirbeln von Probanden quantifiziert und mit mittels der Magnetresonanzspektroskopie (MRS) ermittelten Werten verglichen wurde. Nach erfolgreicher Validierung wurde der Fettvolumenanteil retrospektiv an den fünf Lendenwirbeln von 44 in der im klinischen Routine aufgenommenen Patientendatensätzen gemessen. Die Zweipunkt-Dixon-Methode zeigte eine gute Quantifizierung des Fettvolumenanteils im Phantomexperiment (-9,8% maximaler relativer Fehler in Bezug auf die Nennwerte). Bei den Probanden wurde ein nicht signifikanter Unterschied zwischen MRT und MRS für die Quantifizierung des Fettvolumenanteils in einem Zielvolumen mit ähnlichen Dimensionen und ähnlicher Orientierung festgestellt. In der Patientenstudie wurde festgestellt, dass die Umwandlung des Knochenmarks (rotes Knochenmark → gelbes Knochenmark) altersabhängig und bei Männern (0,3% pro Jahr) langsamer als bei Frauen (0,5% pro Jahr) voranschreitet. Es wurde allerdings auch eine beträchtliche Variabilität des Fettvolumenanteils bei Patienten ähnlichen Alters und gleichen Geschlechts beobachtet. Diese Ergebnisse ermöglichen die Verwendung der Zweipunkt-Dixon-MRT zur Quantifizierung des Fettvolumenanteils im Knochenmark. Darüber hinaus legt die konstante Umwandlung des Knochenmarks im Erwachsenenalter nahe, dass der von der Internationalen Strahlenschutzkommission (engl. International Commission on Radiological Protection, ICRP) vorgeschlagene konstante Zellvolumenanteil von 0,7 (Referenzwert für einen männlichen Erwachsenen) (1,2) durch einen patientenspezifischen Ansatz ersetzt werden sollte. In einem zweiten Schritt wurde eine auf DEQCT basierende Quantifizierungsmethode in zwei CT-Systemen validiert: i) ein in ein SPECT/CT integriertes klinisches CT und ii) ein Dual-Source-Computertomographie-System (DSCT). Die Methode wurde an zwei Phantomen erprobt: Das erste diente zur Validierung der DEQCT-Methode, wobei der Hydroxylapatit-Volumenanteil in drei 50-Milliter-Phiolen mit drei verschiedenen Hydroxylapatit-Konzentrationen (100 mg/cm3, 200 mg/cm3, 300 mg/cm3) quantifiziert wurde. Das zweite Phantom war das European Spine Phantom (ESP), ein anthropomorphes Wirbelsäulenphantom. Es wurde verwendet, um den Knochenmineralgehalt (engl. Bone Mineral Content, BMC) des gesamten Wirbels und den Hydroxylapatit-Volumenanteil (VFHA) in der Spongiosa-Region jedes Phantomwirbels zu quantifizieren. Schließlich wurde der BMC der Lendenwirbel 1 (LV1) und 2 (LV2) bei einem Patienten unter Verwendung von DEQCT und Dual-Röntgen-Absorptiometrie (engl. dual-energy X-ray absorptiometry, DEXA) gemessen. Darüber hinaus wurden der Hydroxylapatit-Volumenanteil (VFHA) und der Knochenvolumenanteil (VFB) sowohl für die gesamten Wirbel als auch für die Spongiosa-Region von LV1 und LV2 berechnet. Der gemessene und der nominelle Hydroxylapatit-Volumenanteil in den Phiolen zeigten eine gute Korrelation (maximaler relativer Fehler: 14,2%). Die Quantifizierung des BMC im gesamten Wirbel und des VFHA in der Spongiosa-Region zeigten größere relative Fehler als im Validierungsphantom: Die BMC-Quantifizierung für LV1 und LV2 ergaben relative Fehler zwischen DEXA und DSCT in Höhe von 7,6% (LV1) und -8,4% (LV2). Auch die Werte des VFHA (mineralischer Knochen) waren kleiner als die des VFB. Dieses Ergebnis steht im Einklang mit der Knochenzusammensetzung (Knochenmineral plus organisches Material). Die DEQCT-Methode ermöglicht die Quantifizierung von Hydroxylapatit (mineralischer Knochen) und Knochen (mineralischer Knochen plus organisches Material) in einem klinischen Umfeld. Die Methode zeigte jedoch eine Überschätzung des quantifizierten mineralischen Knochenvolumenanteils. Diese Überschätzung könnte mit dem Mangel an detaillierten Informationen über die CT-Röntgenspektren und die Detektorempfindlichkeit zusammenhängen. Auch die DEQCT-Methode zeigte eine Abhängigkeit vom verwendeten CT-Rekonstruktionsalgorithmus und der chemischen Beschreibung der zu quantifizierenden Materialien. Die Ergebnisse dieser Dissertation zeigen die Machbarkeit einer Quantifizierung des Fettvolumenteils und des Knochenvolumenteils in der Spongiosa in einem klinischen Kontext. Darüber hinaus geben die Unterschiede im Fettvolumenanteil von Frauen und Männern sowie die Variabilität des Fettvolumenanteils bei Individuen ähnlichen Alters Grund zur kritischen Auseinandersetzung mit der Näherung des Zellvolumenanteils durch nur einen einzelnen ICRP-Referenzwert in der Knochenmarkdosimetrie bei Radionuklidtherapien. Zusätzlich wird in dieser Arbeit der erste Ansatz für eine nicht-invasive Quantifizierung des Volumenanteils des Knochens (Knochenmineral plus organisches Material) für eine verbesserte Dosimetrie des Knochenmarks vorgestellt. KW - 2-point Dixon KW - MRI KW - DEQCT KW - Bone Quantification KW - Fat Quantification KW - Molecular Radiotherapy KW - Internal Dosimetry KW - Bone Marrow Dosimetry KW - Nuclar Medicine Y1 - 2020 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-208503 ER - TY - THES A1 - Kleineisel, Jonas T1 - Variational networks in magnetic resonance imaging - Application to spiral cardiac MRI and investigations on image quality T1 - Variational Networks in der Magnetresonanztomographie - Anwendung auf spirale Herzbildgebung und Untersuchungen zur Bildqualität N2 - Acceleration is a central aim of clinical and technical research in magnetic resonance imaging (MRI) today, with the potential to increase robustness, accessibility and patient comfort, reduce cost, and enable entirely new kinds of examinations. A key component in this endeavor is image reconstruction, as most modern approaches build on advanced signal and image processing. Here, deep learning (DL)-based methods have recently shown considerable potential, with numerous publications demonstrating benefits for MRI reconstruction. However, these methods often come at the cost of an increased risk for subtle yet critical errors. Therefore, the aim of this thesis is to advance DL-based MRI reconstruction, while ensuring high quality and fidelity with measured data. A network architecture specifically suited for this purpose is the variational network (VN). To investigate the benefits these can bring to non-Cartesian cardiac imaging, the first part presents an application of VNs, which were specifically adapted to the reconstruction of accelerated spiral acquisitions. The proposed method is compared to a segmented exam, a U-Net and a compressed sensing (CS) model using qualitative and quantitative measures. While the U-Net performed poorly, the VN as well as the CS reconstruction showed good output quality. In functional cardiac imaging, the proposed real-time method with VN reconstruction substantially accelerates examinations over the gold-standard, from over 10 to just 1 minute. Clinical parameters agreed on average. Generally in MRI reconstruction, the assessment of image quality is complex, in particular for modern non-linear methods. Therefore, advanced techniques for precise evaluation of quality were subsequently demonstrated. With two distinct methods, resolution and amplification or suppression of noise are quantified locally in each pixel of a reconstruction. Using these, local maps of resolution and noise in parallel imaging (GRAPPA), CS, U-Net and VN reconstructions were determined for MR images of the brain. In the tested images, GRAPPA delivers uniform and ideal resolution, but amplifies noise noticeably. The other methods adapt their behavior to image structure, where different levels of local blurring were observed at edges compared to homogeneous areas, and noise was suppressed except at edges. Overall, VNs were found to combine a number of advantageous properties, including a good trade-off between resolution and noise, fast reconstruction times, and high overall image quality and fidelity of the produced output. Therefore, this network architecture seems highly promising for MRI reconstruction. N2 - Eine Beschleunigung des Bildgebungsprozesses ist heute ein wichtiges Ziel von klinischer und technischer Forschung in der Magnetresonanztomographie (MRT). Dadurch könnten Robustheit, Verfügbarkeit und Patientenkomfort erhöht, Kosten gesenkt und ganz neue Arten von Untersuchungen möglich gemacht werden. Da sich die meisten modernen Ansätze hierfür auf eine fortgeschrittene Signal- und Bildverarbeitung stützen, ist die Bildrekonstruktion ein zentraler Baustein. In diesem Bereich haben Deep Learning (DL)-basierte Methoden in der jüngeren Vergangenheit bemerkenswertes Potenzial gezeigt und eine Vielzahl an Publikationen konnte deren Nutzen in der MRT-Rekonstruktion feststellen. Allerdings besteht dabei das Risiko von subtilen und doch kritischen Fehlern. Daher ist das Ziel dieser Arbeit, die DL-basierte MRT-Rekonstruktion weiterzuentwickeln, während gleichzeitig hohe Bildqualität und Treue der erzeugten Bilder mit den gemessenen Daten gewährleistet wird. Eine Netzwerkarchitektur, die dafür besonders geeignet ist, ist das Variational Network (VN). Um den Nutzen dieser Netzwerke für nicht-kartesische Herzbildgebung zu untersuchen, beschreibt der erste Teil dieser Arbeit eine Anwendung von VNs, welche spezifisch für die Rekonstruktion von beschleunigten Akquisitionen mit spiralen Auslesetrajektorien angepasst wurden. Die vorgeschlagene Methode wird mit einer segmentierten Rekonstruktion, einem U-Net, und einem Compressed Sensing (CS)-Modell anhand von qualitativen und quantitativen Metriken verglichen. Während das U-Net schlecht abschneidet, zeigen die VN- und CS-Methoden eine gute Bildqualität. In der funktionalen Herzbildgebung beschleunigt die vorgeschlagene Echtzeit-Methode mit VN-Rekonstruktion die Aufnahme gegenüber dem Goldstandard wesentlich, von etwa zehn zu nur einer Minute. Klinische Parameter stimmen im Mittel überein. Die Bewertung von Bildqualität in der MRT-Rekonstruktion ist im Allgemeinen komplex, vor allem für moderne, nichtlineare Methoden. Daher wurden anschließend forgeschrittene Techniken zur präsizen Analyse von Bildqualität demonstriert. Mit zwei separaten Methoden wurde einerseits die Auflösung und andererseits die Verstärkung oder Unterdrückung von Rauschen in jedem Pixel eines untersuchten Bildes lokal quantifiziert. Damit wurden lokale Karten von Auflösung und Rauschen in Rekonstruktionen durch Parallele Bildgebung (GRAPPA), CS, U-Net und VN für MR-Aufnahmen des Gehirns berechnet. In den untersuchten Bildern zeigte GRAPPA gleichmäßig eine ideale Auflösung, aber merkliche Rauschverstärkung. Die anderen Methoden verhalten sich lokal unterschiedlich je nach Struktur des untersuchten Bildes. Die gemessene lokale Unschärfe unterschied sich an den Kanten gegenüber homogenen Bildbereichen, und Rauschen wurde überall außer an Kanten unterdrückt. Insgesamt wurde für VNs eine Kombination von verschiedenen günstigen Eigenschaften festgestellt, unter anderem ein guter Kompromiss zwischen Auflösung und Rauschen, schnelle Laufzeit, und hohe Qualität und Datentreue der erzeugten Bilder. Daher erscheint diese Netzwerkarchitektur als ein äußerst vielversprechender Ansatz für MRT-Rekonstruktion. KW - Kernspintomografie KW - Convolutional Neural Network KW - Maschinelles Lernen KW - Bildgebendes Verfahren KW - magnetic resonance imaging KW - convolutional neural network KW - variational network KW - cardiac imaging KW - machine learning KW - local point-spread function KW - resolution KW - g-factor Y1 - 2024 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-347370 ER -