TY - THES A1 - Hafer [geb. Zailer], Elina T1 - Tagging - Development of new qNMR methods T1 - Tagging - Die Entwicklung neuer Quantifizierungmethoden in der NMR Spektroskopie N2 - High-resolution nuclear magnetic resonance (NMR) spectroscopy is used in structure elucidation and qualitative as well as quantitative examination of product components. Despite the worldwide development of numerous innovative NMR spectroscopic methods, several official methods that analyze specific substances and do not represent a holistic analysis, are still in use for the quality control of drugs, food and chemicals. Thus, counterfeit or contaminated products of inferior quality can be brought onto the market and distributed despite previous quality controls. To prevent this, three NMR spectroscopic methods have been developed within the scope of this work (1) to study the peroxide value in vegetable and animal oils, (2) for the qualitative and quantitative analysis of metal cations and (3) to determine the enantiomeric excess in chiral alcohols. In oil analysis, titration methods are used to determine the bulk quality parameters such as peroxide value, which represents the concentration of peroxides. Titrations show several drawbacks, such as the need of a large amount of sample and solvents, cross reactions and the low robustness. Thus, an alternative NMR spectroscopic method was developed to improve the peroxide analysis by using triphenylphosphine as a derivatization reagent, which reacts with peroxides in a stoichiometric ratio of 1:1 forming triphenylphosphine oxide. In the 1H-31P decoupled NMR spectrum, the signals of the unreacted triphenylphosphine and the reacted triphenylphosphine oxide are detected at 7.4 ppm and 7.8 ppm, respectively. The ratio of the two signals is used for the calculation of the peroxide concentration. 108 oil samples with a peroxide value between 1 meq/kg and 150 meq/kg were examined using the developed method. Oils with a very low peroxide value of less than 3 meq/kg showed a relative standard deviation of 4.9%, highly oxidized oils with a peroxide value of 150 meq/kg of 0.2%. The NMR method was demonstrated as a powerful technique for the analysis of vegetable and krill oils. Another 1H NMR spectroscopic method was developed for the qualitative determination of Be2+, Sr2+ and Cd2+, and for the qualitative and quantitative determination of Ca2+, Mg2+, Hg2+, Sn2+, Pb2+ and Zn2+ by using ethylenediamine tetraacetate (EDTA) as complexing agent. EDTA is a hexadentate ligand that forms stable chelate complexes with divalent cations. The known amount of added EDTA and the signal ratio of free and complexed EDTA are used to calculate the concentrations of the divalent cations, which makes the use of an internal standard obsolete. The use of EDTA with Be2+, Sr2+, Cd2+, Ca2+, Mg2+, Hg2+, Sn2+, Pb2+ and Zn2+ result in complexes whose signals are pH-independent, showing cation-specific chemical shifts and couplings in the 1H NMR spectrum that are used for identification and quantification. In the presented NMR method, the limit of quantification of the cations Ca2+, Mg2+, Hg2+, Sn2+, Pb2+, and Zn2+ was determined with 5-22 μg/mL. This method is applicable in the food and drug sectors. The third NMR spectroscopic method introduced an alternative determination of the enantiomer excess (ee) of the chiral alcohols menthol, borneol, 1-phenylethanol and linalool using phosgene as a derivatizing reagent. Phosgene reacts with a chiral alcohol to form carboxylic acid diesters, made of two identical (RR, SS) or two different enantiomers (RS, SR). These two different types of diastereomers can be examined by the difference of their chemical shifts. In the presented method, the integration values of the carbonyl signals in the 13C NMR spectrum are used for the determination of the enantiomer excess. The limit of quantification depends, among others, on the sample and on the non-labelled or 13C-labelled phosgene used for the analysis. In the case of menthol, a quantification limit of ee=99.1% was determined using non-labelled phosgene and ee=99.9% using 13C-labelled phosgene. The 13C NMR method was also applied for the quality control of the enantiomeric purity of borneol, 1-phenylethanol and linalool. The developed 13C NMR method represents a powerful alternative to Mosher’s reagent for investigating the enantiomeric excess in chiral alcohols. This work demonstrates the variety of possibilities of applications for the quantitative nuclear magnetic resonance spectroscopy in the chemical analysis of drugs, food and chemicals using tagging reactions such as derivatizations and complexations. The nuclear resonance spectroscopic methods developed in this research work represent powerful alternatives to the previously used quality control techniques. N2 - Die hochauflösende Kernresonanzspektroskopie findet heute primär Anwendung in derStrukturaufklärung und der qualitativen sowie quantitativen Untersuchung von Produkt-inhaltsstoffen. Trotz der weltweiten Entwicklung von innovativen kernresonanzspektrosko-pischen Methoden sind noch zahlreiche, offiziell anerkannte Methoden zur Qualitätskon-trolle von Arzneimitteln, Lebensmitteln und Chemikalien in Verwendung, die spezifischeSubstanzen kontrollieren und keine ganzheitliche Untersuchung darstellen. Somit könnenverunreinigte, qualitativ minderwertige oder gefälschte Produkte trotz vorheriger Quali-tätskontrollen auf den Markt gebracht und vertrieben werden. Um dies zu verhindern,wurden im Rahmen dieser Arbeit drei kernresonanzspektroskopische Methoden entwickelt,die zur (1) Bestimmung der primären Oxidation in pflanzlichen und tierischen Ölen anhandder Peroxidzahl, (2) zur qualitativen und quantitativen Analyse von Metallkationen und(3) zur Ermittlung des Enantiomerüberschusses in chiralen Alkoholen dienen.In der Ölanalytik werden Titrationsverfahren zur Bestimmung der Bulkqualitätsparameterwie auch der Peroxidzahl, welche die Konzentration an Peroxiden aufzeigt, eingesetzt. Dadie Titration neben dem Einsatz von größeren Mengen an Probenmaterial und Lösungsmit-teln, auch Kreuzreaktionen und eine geringe Robustheit aufweist, wurde eine kernreso-nanzspektroskopische Methode entwickelt, in der Triphenylphosphin als Derivatisierungs-reagenz eingesetzt wird, welches mit Peroxiden im stöchiometrischen Verhältnis von 1:1zu Triphenylphosphinoxid reagiert. Im1H-31P entkoppelten Kernresonanzspektrum wer-den die Signale des nicht reagierten Triphenylphosphins bei 7,4 ppm und des reagiertenTriphenylphosphinoxid bei 7,8 ppm detektiert. Das Verhältnis beider Signale wird in dieKonzentration der Peroxide umgerechnet. 108 Ölproben mit einer Peroxidzahl zwischen 1meq/kg und 170 meq/kg wurden mit der entwickelten Methode untersucht. Hierbei zeigtenÖle mit einer sehr geringen Peroxidzahl von weniger als 3 meq/kg eine relative Standard-abweichung von 4,9%, hochoxidierte Öle mit einer Peroxidzahl von 150 meq/kg 0,2%. Diekernresonanzspektroskopische Methode findet Anwendung in der Untersuchung von Krill-und pflanzlichen Ölen.Eine weitere1H kernresonanzspektroskopische Methode wurde zur qualitativen Analyse. Zusammenfassungvon Be2+, Sr2+und Cd2+und zur qualitatitativen sowie quantitativen Bestimmung vonCa2+, Mg2+, Hg2+, Sn2+, Pb2+und Zn2+entwickelt. Hierbei wurde Ethylendiamintetra-acetat (EDTA) als Komplexbildner verwendet. EDTA ist ein sechszähniger-Ligand, derstabile Chelatkomplexe mit zweiwertigen Kationen bildet. Die definierte Menge an EDTAund das Verhältnis von freier und komplexierter EDTA nach Zugabe der Probe werdenfür die Rückrechnung der Konzentration der Kationen verwendet. Somit ist der Einsatzeines internen Standards obsolet. EDTA komplexiert Be2+, Sr2+, Cd2+, Ca2+, Mg2+, Hg2+,Sn2+, Pb2+und Zn2+zu stabilen Komplexen, deren Signale im Protonen-Kernresonanz-spektrum pH-unabhängige und kationenspezifische chemische Verschiebungen und Kop-plungen aufweisen, die zur Identifizierung und Quantifizierung verwendet werden. DieKoaleszenz der∆undΛKonfigurationen des EDTA-Komplexes mit Be2+, Sr2+und Cd2+führt bei 298K zu einer Signalverbreiterung, die eine Quantifizierung bei den vorliegendenParametern unmöglich macht. Die Kationen Ca2+, Mg2+, Hg2+, Sn2+, Pb2+und Zn2+sindab einer Konzentration von 5-22μg/mL quantitativ in wässriger Lösung quantifizierbar.Diese Methode kann im Lebensmittel- und Arzneimittelbereich eingesetzt werden.Die dritte kernresonanzspektroskopische Methode stellt eine neue Bestimmung des Enan-tiomerüberschusses (ee) in den chiralen Alkoholen Menthol, Borneol, 1-Phenylethanol undLinalool unter Einsatz von Phosgen als Derivatisierungsreagenz vor. Phosgen reagiert miteinem chiralen Alkohol zu Carbonsäurediestern, die aus zwei gleichen (RR, SS) oder zweiunterschiedlichen Enantiomeren (RS, SR) entstehen. Diese zwei Diastereomertypen kön-nen anhand der unterschiedlichen, chemischen Verschiebungen ihrer Signale identifiziertwerden. In der vorgestellten Methode wird das Carbonylsignal integriert und zur Bes-timmung des Enantiomerenüberschusses eingesetzt. Die Bestimmungsgrenze ist hierbeiu. a. von dem eingesetzten Phosgen und der Probe abhängig. Bei Menthol wurdeeine Bestimmungsgrenze mittels nicht markiertem Phosgen von ee = 99,1% und mit-tels13C-markiertem Phosgen von ee = 99,9% ermittelt. Die13C Methode wurde zudemzur Qualitätskontrolle der Enantiomerreinheit von Borneol, 1-Phenylethanol sowie vonLinalool eingesetzt. Hierbei enthielten die käuflich erworbenen Chemikalien (-)-Borneolund (S)-1-Phenylethanol jeweils 1,7% des anderen Enantiomers (+)-Borneol bzw. (R)-1-Phenylethanol. Bei (-)-Linalool konnte ein Enantiomerüberschuss von ee = 66,4% undsomit eine größere Verunreinigung durch (+)-Linalool identifiziert werden. Bei Proben,die einen Enantiomerüberschuss von ee < 95,0% aufweisen, sollte eine potentielle, asym-metrische Induktion mittels Kalibrationskurven anhand von künstlichen Enantiomeren-mischungen vorab untersucht werden. Die entwickelte13C kernresonanzspektroskopischeMethode präsentiert eine leistungsstarke Alternative zur Analyse mittels Mosher’s Reagenzfür die Untersuchung des Enantiomerüberschusses in chiralen Alkoholen.Diese Arbeit weist eine Vielfalt an Möglichkeiten der Anwendungen der quantitativen Kern-resonanzspektroskopie in der chemischen Untersuchung von Arzneimitteln, Lebensmittelnund Chemikalien unter Einsatz von Tagging, wie Derivatisierungen und Komplexierun-gen auf. Die hierbei entwickelten kernresonanzspektroskopischen Methoden repräsentierenleistungsstarke Alternativen zu bisher eingesetzten Techniken der Qualitätskontrolle KW - NMR Spektroskopie KW - EDTA KW - Lipid-Peroxide KW - Chiralität KW - Derivsatisierung KW - Peroxidzahl KW - Enantiomerüberschuss KW - qNMR Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-219583 ER - TY - THES A1 - Pawellek, Ruben T1 - Charged Aerosol Detector Performance Evaluation and Development of Optimization Strategies for the Analysis of Amino Acids T1 - Leistungsbeurteilung des Charged Aerosol Detektors und Entwicklung von Optimierungsstrategien für die Analyse von Aminosäuren N2 - The charged aerosol detector (CAD) is an aerosol-based detector employed in liquid chromatography which has become established in the field of pharmaceutical analysis due to its outstanding performance characteristics, e.g. the almost uniform response for nonvolatile analytes. Owing to its principle of detection, the response of the CAD depends on the volatility of a compound and is inherently nonlinear. However, the newly implemented instrumental settings evaporation temperature and power function value (PFV) are valuable tools to overcome some of these drawbacks and can even enhance the detector’s capabilities when adjusted properly. This thesis aimed to evaluate the impact of the new instrumental settings on the CAD performance. Additionally, the influence of modern separation techniques for small polar compounds on the CAD was assessed and the applicability of hyphenated UV-CAD techniques explored. The optimization strategies derived from the evaluation procedures and the conjunction of the instrumental and chromatographic techniques investigated were utilized for the challenging impurity profiling of amino acids and amino acid-like drugs. The results of the method validation procedures confirmed the broad applicability of the CAD in the pharmaceutical analysis of nonvolatile compounds, supported by satisfactory sensitivity and reproducibility for meeting the regulatory requirements with respect to the ICH guidelines Q2(R1) and Q3A(R2). The limits of applicability include the analysis of semivolatile compounds, and the method transfer between current and legacy CAD models. Further advances in the definition and standardization of allowed ranges for the instrumental settings and the establishment of general optimization procedures in the method development could lead to a more widespread use of the detection technique in compendial methods. N2 - Der “charged aerosol detectorˮ (CAD) ist ein aerosol-basierter Detektor in der Flüssigchromatographie, der sich im Bereich der pharmazeutischen Analytik etabliert hat, da er über herausragende Leistungsmerkmale verfügt, wie das annährend einheitliche Signal für nichtflüchtige Analyte. Aufgrund des Detektionsprinzips ist das Signal des Detektors abhängig von der Flüchtigkeit einer Verbindung und zudem nichtlinear. Die neu eingeführten Geräteparameter Verdampfungstemperatur und „power function value” (PFV) stellen hierbei wertvolle Werkzeuge dar, um einige der mit dem Detektionsprinzip verbundenen Nachteile auszugleichen und können darüber hinaus die Detektionsmöglichkeiten erweitern, sofern sie auf geeignete Weise eingestellt wurden. Die vorliegende Arbeit hatte zum Ziel, die Auswirkungen der neuen Geräteparameter auf die Leistungsfähigkeit des Detektors zu untersuchen. Zusätzlich wurde der Einfluss moderner Trenntechniken auf den CAD beurteilt und die Anwendbarkeit gekoppelter UV-CAD Techniken erforscht. Die sich aus den Evaluierungsprozeduren ergebenden Optimierungsstrategien und die Verknüpfung der untersuchten instrumentellen und chromatographischen Techniken wurden anschließend verwendet, um Methoden für die herausfordernde Verunreinigungsanalyse von Aminosäuren und Arzneistoffen mit Aminosäurestruktur zu entwickeln. Die Ergebnisse der Validierungsverfahren bestätigten die weitgehende Anwendbarkeit des CAD in der pharmazeutischen Analyse nichtflüchtiger Verbindungen, unterstützt durch zufriedenstellende Empfindlichkeit und Reproduzierbarkeit, wodurch die Vorgaben der ICH-Leitfäden Q2(R1) und Q3A(R2) erfüllt werden konnten. Einschränkungen der Anwendbarkeit bestehen in der Analyse halbflüchtiger Verbindungen, sowie im Methodentransfer zwischen gegenwärtigen und alten CAD-Modellen. Weitere Fortschritte in der Definition und Standardisierung erlaubter Bereiche für die Einstellung der Geräteparameter und die Etablierung allgemeiner Optimierungsverfahren in der Methodenentwicklung könnten zu einer umfassenderen Nutzung der Detektionstechnik für Arzneibuchmethoden führen. KW - Instrumentelle Analytik KW - HPLC KW - Chemische Reinheit KW - Chromatographischer Detektor KW - Pharmaceutical Analysis KW - Charged Aerosol Detection KW - Impurity Profiling KW - Amino Acids KW - Aminosäuren Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-243197 ER - TY - THES A1 - Höllein, Ludwig T1 - Entwicklung vereinfachter flüssigchromatographischer 
Untersuchungsmethoden zur Qualitätskontrolle essentieller Antimalaria-Medikamente in Entwicklungs- und 
Schwellenländern N2 - Im Rahmen dieser Arbeit wurden sehr einfache, flüssigchromatographische Methoden zur Qualitätsanalytik gebräuchlicher Antimalaria-Medikamente (Amodiaquin, Mefloquin, Proguanil sowie die Kombination Artemether/Lumefantrin) entwickelt, die nur wenige, günstig erhältliche Chemikalien (Phosphatpuffer, Methanol) sowie gewöhnliche, kommerzielle RP-18-Säulen benötigen. Sie sind insbesondere zur Anwendung in Laboratorien in Entwicklungsländern geeignet und erfordern keine komplexen HPLC-Instrumente wie beispielsweise Gradientenpumpen oder Säulenthermostate. Der Verzicht auf Ionenpaarreagenzien ermöglicht es, dass eine stationäre Phase für mehr als nur einen einzigen Einsatzzweck verwendet werden kann und dass langwierige Äquilibrier- bzw. Spülschritte nicht notwendig sind. Alle Methoden arbeiten im isokratischen Elutionsmodus und durch die Verwendung kurzer Säulen (125 mm) konnten die jeweiligen Analysenzeiten zusätzlich verringert werden. Hierdurch ist zudem eine Reduzierung des Fließmittelverbrauches möglich. Während der Methodenentwicklung wurden charakteristische, aus dem Herstellungsweg des jeweiligen Arzneistoffes stammende potentielle Verunreinigungen berücksichtigt. Ihre Bestimmung erlaubt eine Aussage über die Herkunft eines Wirkstoffes bzw. eines Arzneimittels, da das Verunreinigungsmuster einer Substanz oftmals die Zuordnung zu einem bestimmten Herstellungs- bzw. Reinigungsprozess ermöglicht. Alle Methoden wurden hinsichtlich der Linearität innerhalb des Arbeitsbereiches sowie der Wiederholpräzision charakterisiert. Es wurde eine gute Reproduzierbarkeit gefunden. Die Nachweis- und Bestimmungsgrenzen der untersuchten Verunreinigungen lagen bei einem Level von je 0.1 %. Durch gezielte Variation wurde der Einfluss wechselnder Trenntemperaturen sowie schwankender pH-Werte der jeweiligen mobilen Phase und die hieraus resultierenden Effekte untersucht. Hierbei zeigte sich, dass die Methoden sehr robust gegenüber diesen Einflussgrößen sind und somit für die Anwendung mit einfach ausgestatteten HPLC-Systemen sowie besonders für den Einsatz in tropische Gebieten mit wechselnden klimatischen Bedingungen gut geeignet sind. Flüssigchromatographische Methoden spielen heute in der pharmazeutischen Analytik vor allem zur Bestimmung der Reinheit eines Arzneistoffes eine herausragende Rolle und sind in nahezu jeder Monographie der wichtigsten Arzneibücher (z. B. im Ph. Eur.) zu finden. Einfach durch-führbare Untersuchungsmethoden, wie beispielsweise die im GPHF-Minilab® angewandte Dünnschichtchromatographie, erfordern im Vergleich zur HPLC weniger komplexe und teure Instrumente und können selbst in entlegenen Gebieten ohne Laboratorium durchführt werden. Sie verfügen allerdings über eine nur sehr geringe Genauigkeit und Reproduzierbarkeit, da sowohl die praktische Durchführung als auch die anschließende Auswertung rein manuell bzw. visuell erfolgt und somit in hohem Maße einer Beeinflussung durch den jeweiligen Analytiker unterworfen ist. Die entwickelten HPLC-Methoden wurden mit dünnschichtchromatographischen Verfahren verglichen, hierbei besonders unter dem Aspekt der visuellen und der instrumentellen Auswertung der Chromatogramme zur Bestimmung des Gehaltes einer unbekannten Probe. Hierbei konnte aufgezeigt werden, dass die Dünnschichtchromatographie der Flüssigchromatographie eindeutig unterlegen ist, insbesondere wenn die Auswertung nicht mittels eines entsprechenden Scanners sondern rein visuell erfolgt: Nur in den wenigsten Fällen ist es möglich, eine annähernd präzise Aussage über den Gehalt zu treffen und zudem ist die Bestimmung der Verwandten Substanzen nur sehr bedingt möglich. Durch den Einsatz von Auftragegeräten bzw. Plattenscannern kann die Genauigkeit zwar signifikant erhöht werden, allerdings sind solche Instrumente im Verhältnis wesentlich teurer als einfache, modulare HPLC-Systeme und zählen heute in den wenigsten Laboratorien zum Standardinventar. Vereinfachte chromatographische Methoden können ein wichtiges Hilfsmittel für Kontrolllaboratorien in Entwicklungsländern sein, wenn komplexe, etablierte Protokolle nur eingeschränkt angewendet werden können. Durch die Kombination aus dünnschichtchromatographischer Basisanalytik und einer flächendeckenden Untersuchung mittels HPLC lässt sich die Arzneimittelqualität sehr gut überprüfen, die regulatorischen Organe eines Landes entsprechend zu entlasten und die Versorgung der Bevölkerung mit qualitativ einwandfreien Medikamenten zu gewährleisten. Ein weiterer Teil der Arbeit befasst sich mit der Stabilitätsanalytik individuell hergestellter, Noradrenalin-haltiger Injektionslösungen. Solche Rezepturen werden oftmals in Krankenhausapotheken im Rahmen der Defektur auf Vorrat durch Verdünnen der entsprechenden kommerzieller Fertigarzneimittel mit isotonischer Kochsalzlösung zubereitet, um z. B. für Notfallsituationen am Wochenende die Rezepturen vorrätig zu haben. Durch die Untersuchungen wurde geprüft, inwieweit der übliche Verdünnungsgrad von 0.1 % einen Einfluss auf die Stabilität des Noradrenalins hat und welche Lagerungsbedingungen für die Zubereitungen empfohlen werden können. Nach der Lagerung unter verschiedenen Bedingungen (gekühlt, bei Raumtemperatur sowie jeweils mit bzw. ohne Lichtschutz) konnte gezeigt werden, dass die Gehalte an Noradrenalin bei keiner der untersuchten Lagerungsbedingungen unter einen Wert von 99.0 % fielen. Individuell hergestellte Noradrenalin-Injektionslösungen können somit bis zu sieben Tage im Voraus hergestellt und für die Anwendung am Patienten bereit gehalten werden. Die Lösungen sollten dennoch gekühlt und unter Lichtschutz aufbewahrt werden, um den Abbau des Arzneistoffes und eine mikrobielle Kontamination zu minimieren. N2 - This work focuses on the development of simple, liquid chromatographic methods for the quality analysis of common antimalarial medicines, i.e. amodiaquine, mefloquine, proguanil and the fix-dose combination of artemether and lumefantrine. They require a minimum of readily available, cheap chemicals (e.g. phosphate buffers or methanol) and commercially available RP-18 columns. They were designed for use in quality control laboratories in resource-restraint environments, e.g. in laboratories in the developing world, and do not require complex HPLC instrumentation which are either not available or affordable, e.g. with expensive gradient pumps or column ovens. Ion-pairing reagents were strictly avoided during method development which is a great advantage for routine application: long equilibration and flushing procedures are not necessary and a column can be used for more than one single method. An isocratic elution mode was applied and using short analytical columns (125 mm) allows reducing the analysis time and eluent consumption, respectively, to a minimum. During method development impurities being characteristic for the respective synthesis pathway(s) of the active substances were considered. Thus, determining the quality of a com-pound with regard to its content and purity is possible and distinct manufacturers or sources can be identified. Linearity and repeatability were assessed and a good reproducibility was found. Limits of detection and quantitation, respectively, were measured and the respective impurities can be determined to a level of 0.1 %. By varying the separation temperature and the pH-value of the respective mobile phases method ruggedness was investigated. A high grade of robustness towards these parameters could be confirmed, indicating that the methods are suitable for being used in tropical environments. Liquid chromatographic methods play an important role in pharmaceutical analysis today and they are widely applied for determining the purity of a compound. Respective protocols have been added to almost every monograph of the most important pharmacopoeias, e.g. the European Pharmacopoeia. Of note, those protocols may not be applied in every laboratory without limitations. Although very simple methods of analysis, e.g. thin-layer chromatography which is described in the manuals of the GPHF-Minilab®, require less expensive instruments and may even be applied in resource-restraint environments, they exhibit a poor accuracy and reproducibility. Preparing and evaluating the plates manually may strongly bias the results, and in addition this highly depends from the respective analyst who performs the tests. The comparison of thin-layer chromatographic assays applying a manual and an instrumental evaluation to results obtained from liquid chromatographic tests clearly exhibited the disadvantages particularly for determining the quality of a compound. It is almost impossible to exactly determine the content of a sample, and a comprehensive test for related substances cannot be carried out. Using application devices and plate readers may increase the accuracy, however such instruments are a lot more expensive than simple, modular HPLC systems and normally do not belong to the standard inventory of a quality control laboratory. Simplified HPLC methods may serve as helpful instruments for the regulatory infrastructure of developing countries. Combining them with basic thin-layer chromatographic tests and applying them comprehensively may enable the respective quality control laboratories to ensure the nationwide supply with immaculate medicines. In the second part of this work the stability of individually prepared dilutions of commercially available norepinephrine injectable solutions was investigated and recommendations for storage conditions were derived. In hospital pharmacies it is a common practice to prepare such solutions from proprietary products by diluting them with isotonic sodium chloride solution or other suitable buffer solutions, respectively, to a concentration of 0.01 mg/ml (1:100). This is important particularly in case of emergencies, e.g. on the weekend or during holidays, because the respective medication can be held in stock even when the pharmacy is closed. Within the framework of the experiments the influence on the stability of norepinephrine after diluting the respective proprietary product with sodium chloride solution was investigated. The samples were stored with and without refrigeration, and unprotected and protected from sunlight. The results showed that under none of the investigated storing conditions the content of norepineprhine decreased significantly. The lowest content which was found was 99.0 %. Thus, individual norepinephrine injectable solutions can be prepared in advance and storing them is possible for at least seven days. Although a degradation of the active ingredient or a diffusion in the primary packaging material (e.g. a syringe made from polyethylene) could not be observed, it is recommended to store the preparations in the refrigerator and protected from light. A microbial contamination may also be avoided like this. T2 - Development of simplified HPLC-methods for the detection of counterfeit antimalarials in developing countries KW - HPLC KW - Qualitätskontrolle KW - Chromatographie KW - Malaria KW - HPLC-Methodenentwicklung KW - Reinheitsanalytik KW - HPLC method development KW - Determination of compound purity Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-113194 ER - TY - THES A1 - Jakob-Rodamer, Verena T1 - Development and validation of LC-MS/MS methods to determine PK/PD parameters of anti-infectives T1 - Entwicklung und Validierung von LC-MS/MS Methoden zur Bestimmung von PK/PD-Parametern von Antiinfektiva N2 - In the present thesis the development and validation of bioanalytical LC-MS/MS methods for the quantification of erythromycin A, erythromycin ethylsuccinate, roxithromycin, clarithromycin, 14 hydroxy clarithromycin, flucloxacillin, piperacillin and moxifloxacin in human plasma and human urine (piperacillin) is introduced. All methods were applied to analyze human plasma and urine samples from clinical trials and therefore, have been validated according to international guidelines. The methods were reliable in these studies and fulfilled all regulatory requirements known at the time of the study conduct. Moreover, the validation data of the macrolides were compared on three different mass spectrometers (API III Plus, API 3000™, API 5000™). The new innovations in the ion source (horizontal versus vertical electrospray), the ionpath (skimmer, QJet) and the diameter of the orifice resulted in better sensitivity and a larger linearity range for the majority of the analytes. Sensitivity was improved up to a factor of 12 (for clarithromycin) between API III Plus to API 3000™ and up to a factor of 8 (for erythromycin and roxithromycin) between API 3000™ and API 5000™, keeping the accuracy and precision data at about the same level. The high sensitivity was a benefit for example for the flucloxacillin study, because concentrations from all subject samples were detectable up to approximately eight half-lives, i.e. no concentrations needed to be reported below the quantification limit. Also the linearity range were extended from two orders of magnitude to up to four orders of magnitude, which increases the likelihood to allow to analyze all samples from a pharmacokinetic study in the same run. This is especially useful if a large concentration range needs to be analysed, for example, if the method shall be applied in an ascending dose study. Then, all low concentrations from the beginning of the study can be determined, as well as all high concentrations, without the need to dilute and analyse single samples repeatedly. The pharmacokinetic data were compared to previously reported literature data and correlated graphically with MIC values of popular microorganisms which might be a starting point for further PK/PD investigations. The PK/PD theory is a very helpful tool for prediction of the efficacy of given drugs against certain micro-organisms. Depending on the pharmacodynamic processes, e. g. the mode of action, three classes of drugs have been identified. In the same way this applies to adverse effects, which need to be minimised by reducing plasma concentrations. These coherences are not well-investigated, yet, and are not discussed further in this thesis. Still, a lot of research has to be done in this interdisciplinary field to minimise uncertainty in single values, like an AUC/MIC. These include: Improve accuracy and precision of bioanalytical methods determining total and free concentration data in biological matrices for calculation of AUC and Cmax These parameters are related to the MIC in pharmacodynamic considerations. Since the determination of the MIC often underlies significant variations and also differences between microbiological laboratories, the determination of concentrations of anti-infectives is particular important, being achievable by scientific exact techniques. Finally, from the volume of distribution of antibiotics can be used to derive information about intracellular concentrations and effectivity of antiinfectives. N2 - In der vorliegenden Arbeit wird die Entwicklung und Validierung von bioanalytischen LC-MS/MS-Methoden zur Quantifizierung von Erythromycin A, Erythromycin-ethylsuccinat, Roxithromycin, Clarithromycin, 14 Hydroxy-clarithromycin, Flucloxacillin, Piperacillin und Moxifloxacin in Humanplasma und Humanurin (Piperacillin) vorgestellt. Alle Methoden wurden für die Analyse von Plasma- und Urinproben aus klinischen Studien beim Menschen eingesetzt und deshalb nach international anerkannten Richtlinien validiert. In diesen Studien haben sich die Methoden bewährt und alle Anforderungen der zum Zeitpunkt der Studie bekannten behördlichen Ansprüche erfüllt. Die Validierungsdaten der Makrolid-Methoden konnten zudem an drei Massenspektrometern der selben Baureihe verglichen werden. Dabei zeigte sich, dass die Neuerungen an der Ionenquelle (horizontale versus vertikale ESI), dem Ionenpfad (Skimmer, QJet), sowie das immer größere Orifice in der Baureihe, nicht nur stetig verbesserte Sensitivität ermöglichen, sondern auch immer größere Linearitätsbereiche. So konnte ein Sensitivitätsgewinn bis zu Faktor 12 (Clarithromycin) von API III Plus auf API 3000™ und bis zu Faktor 8 (Erythromycin und Roxithromycin) von API 3000™ auf API 5000™ bei etwa gleichen Werten für die Präzision erreicht werden. Die hohe Sensitivität zeigte sich zum Beispiel bei der Flucloxacillin Studie von Vorteil, da alle Konzentrationen bis circa acht Halbwertszeiten nach Wirkstoffgabe bestimmt werden konnten, ohne dass einzelne Proben als „BLOQ“ (unter dem Quantifizierungslimit) berichtet werden mussten. Während früher noch Linearitätsbereiche um zwei Größenordnungen üblich waren, sind jetzt am API 5000™ Konzentrationsbereiche über bis zu vier Größenordnungen reproduzierbar linear. Das ist insbesondere von Nutzen, wenn bei einer Substanz ein größerer Konzentrationsbereich gemessen werden muss. Das ist beispielsweise dann der Fall, wenn die Methode für eine Dosissteigerungsstudie eingesetzt werden soll. Dann können sowohl alle kleinen Konzentrationen zu Beginn der Studie gemessen werden, als auch alle hohen Konzentrationen zum Ende der Studie, und zwar ohne, dass einzelne Proben gesondert verdünnt und wiederholt gemessen werden müssen. Die pharmakokinetischen Daten der Antibiotika wurden in den Kontext mit Literaturdaten gestellt und graphisch mit MHK-Werten für gängige Mikroorganismen verglichen, was den Ausgangspunkt für spätere PK/PD-Untersuchungen darstellt. Für die Vorhersage der Wirksamkeit einer verabreichten Substanz gegenüber bestimmten Mikroorganismen ist die PK/PD-Korrelation ein gutes Hilfsmittel. Anhand der pharmakodynamischen Parameter, wie der Wirkungsweise, können drei Antibiotikaklassen gebildet werden. In analoger Weise gilt für die Nebenwirkungen, dass die Plasma-Konzentrationen verringert werden müssen. Diese Zusammenhänge sind jedoch weniger gut untersucht und werden in dieser Dissertation nicht näher diskutiert. In diesem interdisziplinären Feld ist immer noch viel Forschung nötig um beispielsweise Unsicherheiten bei einzelnen Werten wie z.B. AUC/MIC zu minimieren. Diese beinhalten: Verbesserung der Genauigkeit und Präzision von bioanalytischen Methoden welche für die Bestimmung der Gesamtkonzentration und der freien Konzentration in biologischen Matrices verwendet werden um AUC und Cmax zu bestimmen. Diese Parameter werden in pharmakodynamischen Überlegungen in Beziehung zur MHK gesetzt. Da die MHK-Bestimmung oft erheblichen Schwankungen und auch Unterschieden zwischen verschiedenen mikrobiologischen Laboratorien unterliegt, kommt der Konzentrationsbestimmung der Antibiotika besondere Bedeutung zu, weil sie mit naturwissenschaftlich exakten Methoden möglich ist. Aus den Verteilungsvolumina von Antibiotika lassen sich schließlich auch noch Informationen über die intrazelluläre Konzentration und Wirksamkeit von Antibiotika ableiten. KW - Antimikrobieller Wirkstoff KW - Pharmakokinetik KW - Pharmakodynamik KW - LC-MS KW - LC-MS/MS KW - anti-infectives KW - Antiinfektiva KW - mass spectrometry KW - liquid chromatography KW - antibiotic KW - pharmacokinetic KW - clinical study Y1 - 2014 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-109215 ER - TY - THES A1 - Leistner, Adrian Dieter T1 - Improving the quality analysis of monographed drugs - dapsone, baclofen, acarbose and other selected APIs T1 - Verbesserung der Qualitätsanalyse von monographierten Arzneistoffen - Dapson, Baclofen, Acarbose und andere ausgewählte Wirkstoffe N2 - All presented studies aimed on the improvement of the quality analysis of already monographed drugs. Thereby different LC methods were applied and coupled to i.e., the UV/VIS detector, the CAD or a hyphenation of these detectors, respectively. The choice of the chromatographic system including the detector was largely dependent on the physicochemical properties of the respective analytes. With the risk-assessment report on the API cetirizine we presented an exemplary tool, that can help to minimize the risk of the occurrence of unexpected impurities. An in- deep analysis of each step within synthesis pathway by means of reaction matrices of all compounds was performed. It is essential to understand the complete impurity profile of all reactants, solvents, and catalysts and to include them in the matrix. Finally, the API of this synthesis was checked if all impurities are identified by this tool. Of note, a shortcoming of such a targeted approach is that impurities can still occur, but they are not captured. This disadvantage can be partially compensated by non-targeted approaches if they are performed in parallel with the other studies that represent most of the impurities. However, this work also shows that even in a supposedly simple synthesis, potentially hundreds of by-products can be formed. For each of them, it must be decided individually whether their formation is probable or how their quantity can be minimized in order to obtain APIs, that are as pure as possible. In the dapsone project it was aimed to replace the existing old Ph. Eur. TLC method with a modern RP-HPLC method. This was successful and since Ph. Eur. 10.6, the method developed in this work, became a valid monograph. Within the revision process of the monograph, the individual limits for impurities were tightened. However, this new method needs HPLC instrumentation, suitable to perform gradients. As this is not always available in all control laboratories, we also developed an alternative, more simple method using two different isocratic runs for the impurity analysis. The obtained batch results of both, the new pharmacopoeial method and the more simple one, were in a comparable order of magnitude. Furthermore, within the method development stage of the Ph. Eur. method, we could identify one unknown impurity of the impurity reference by high-resolution MS/MS analysis. Also, in the baclofen project it was aimed to replace the existing Ph. Eur. method with the introduction of an additional impurity to be quantified. A corresponding method was developed and validated. However, due to the harmonization process of the pharmacopoeias, it is currently not used. In addition, we tried to find further, non- 116 SUMMARY chromophoric impurities by means of the CAD. However, except for one counterion of an impurity, no further impurities were found. Also, the aforementioned new impurity could not be detected above the reporting threshold in the batches analyzed. As the only individually specified impurity A is also present at a low level, it can be concluded that the examined batches of baclofen are very pure. The use of universal detectors, such as the CAD can be particularly interesting for compounds with no chromophore or those with only a weak chromophore. Therefore, we decided to take a closer look at the impurity profile of acarbose. Currently, acarbose and its impurities are being studied by low wavelength UV detection at 210 nm. Therefore, the question arose whether there are no other impurities in the API that do not show absorption at this wavelength. CAD, which offers consistent detection properties for all non-volatile compounds, is ideally suited for this purpose. However, it was not so easy to use the CAD together with the UV detector, for example, as a hyphenated detection technique, because the Ph. Eur. method uses phosphate buffers. However, this is non-volatile and therefore inappropriate for the CAD. Therefore, an attempt was made to replace the buffer with a volatile one. However, since this did not lead to satisfactory results and rather the self-degradation process of the stationary phase used could be observed by means of the CAD, it was decided to switch to alternative stationary phases. A column screening also revealed further difficulties with acarbose and its impurities: they show an epimerization reaction at the end of the sugar chain. However, since one wanted to have uniform peaks in the corresponding chromatograms, one had to accelerate this reaction significantly to obtain only one peak for each component. This was best achieved by using two stationary phases: PGC and Amide-HILIC. Impurity-profiling methods could be developed on each of the two phases. In addition, as expected, new impurities could be detected, albeit at a low level. Two of them could even be identified by spiking experiments as the sugar fragments maltose and maltotriose. Taken together, it can be concluded, that this work has contributed significantly to the improvement of the quality analysis of monographed drugs. In addition to the presented general tool for the identification of potential impurities, one of the methods developed, had already been implemented to the Ph. Eur. In an effort to improve the CAD's universal detection capabilities, additional methods have also been developed. Further, new improved methods for the impurity profiling are ready to use. N2 - Alle vorgestellten Arbeiten zielten auf die Verbesserung der Qualitätsanalyse von im Europäischen Arzneibuch monographierten Wirkstoffen ab. Dabei wurden verschiedene flüssig-chromatographische Methoden angewandt und z.B. mit dem UV/VIS-Detektor, dem CAD oder einer Kombination dieser Detektoren gekoppelt. Die Wahl des chromatographischen Systems einschließlich des Detektors war weitgehend von den physikochemischen Eigenschaften der jeweiligen Analyten abhängig. Mit dem Bericht zur Risikoanalyse des Wirkstoffs Cetirizin haben wir ein beispielhaftes Instrument vorgestellt, das helfen kann, das Risiko des Auftretens unerwarteter Verunreinigungen zu minimieren. Es wurde eine eingehende Analyse der einzelnen Syntheseschritte anhand der Reaktionsmatrizen aller Verbindungen durchgeführt. Dabei ist wichtig, das vollständige Verunreinigungsprofil aller Reaktanten, Lösungsmittel und Katalysatoren zu verstehen und in die Matrix mit aufzunehmen. Schließlich wurde produzierte Arzneistoff-Chargen überprüft, ob alle Verunreinigungen mit diesem Werkzeug identifiziert werden konnten. Es soll aber nicht unerwähnt bleiben, dass ein Nachteil eines solch gezielten Ansatzes darin besteht, dass Verunreinigungen im Wirkstoff dennoch vorkommen können, sie aber nicht durch das Tool erfasst werden. Dieser Nachteil kann z.B. durch nicht-zielgerichtete Ansätze kompensiert werden, wenn sie parallel zu den anderen Untersuchungen durchgeführt werden, die bereits den Großteil der Verunreinigungen abbilden können. Diese Arbeit zeigt aber auch, dass selbst bei einer vermeintlich einfachen Synthese potenziell Hunderte von Nebenprodukten gebildet werden können. Für jedes von ihnen muss individuell entschieden werden, ob ihre Bildung wahrscheinlich ist und wie ihre Menge im Endprodukt minimiert werden kann, um möglichst reine Wirkstoffe zu erhalten. Im Dapsonprojekt wurde versucht, die bestehende dünnschichtchromatographische Ph.Eur.-Methode durch eine moderne HPLC-Methode zu ersetzen. Dies war erfolgreich und seit Ph. Eur. 10.6 wurde die in dieser Arbeit entwickelte Methode zu einer gültigen Monographie. Im Rahmen der Überarbeitung der Monographie sind auch die einzelnen Grenzwerte für Verunreinigungen verschärft worden. Die neue Methode erfordert jedoch ein HPLC-Gerät, mit dem man eine Gradientenelution durchführen kann. Da dies aber nicht immer in allen Kontrolllabors verfügbar ist, haben wir ein alternatives, einfacheres Prozedere entwickelt, bei dem zwei verschiedene isokratische Methoden für die Verunreinigungsanalyse verwendet werden. Die Batch- Ergebnisse der neuen und der einfacheren Methode lagen dabei in einer 118 ZUSAMMENFASSUNG vergleichbaren Größenordnung wie die Ph. Eur.-Methode. Darüber hinaus konnten wir eine unbekannte Verunreinigung der Verunreinigungsreferenz durch hochauflösende Massenspektrometrie identifizieren. Im Rahmen des Baclofen-Projekts sollte die bestehende Ph. Eur.-Methode ersetzt werden und die Monographie durch eine zusätzlich zu quantifizierende Verunreinigung ergänzt werden. Eine entsprechende Methode wurde entwickelt und validiert. Aufgrund des Harmonisierungsprozesses der Pharmakopöen wird sie jedoch derzeit nicht verwendet. Darüber hinaus haben wir versucht, mit Hilfe des CAD weitere, nicht- chromophore Verunreinigungen zu finden. Bis auf ein Gegenion einer Verunreinigung wurden jedoch keine weiteren Verunreinigungen gefunden. Auch die oben erwähnte neue Verunreinigung konnte in den untersuchten Chargen nicht oberhalb des Berichtsgrenzwert nachgewiesen werden. Da auch die sonst einzig individuell zu spezifizierende Verunreinigung A nur in geringem Maße vorhanden ist, kann der Schluss gezogen werden, dass die untersuchten Baclofen-Chargen sehr rein sind. Der Einsatz von universellen Detektoren wie dem CAD kann besonders für Verbindungen ohne Chromophor oder solche mit nur schwachem Chromophor interessant sein. Daher wurde das Verunreinigungsprofil von Acarbose genauer untersucht. Derzeit werden Acarbose und ihre Verunreinigungen mit Hilfe der UV- Detektion bei 210 nm untersucht. Daher stellte sich die Frage, ob es nicht noch anderen Verunreinigungen im Wirkstoff gibt, die keine Absorption bei dieser Wellenlänge zeigen. Die Detektion mittels CAD, der für alle nichtflüchtigen Verbindungen gleichbleibende Werte liefert, ist für diesen Zweck gut geeignet. Allerdings war es nicht so einfach, den CAD zusammen mit dem UV-Detektor z. B. als gekoppeltes Detektionsverfahren zu verwenden, da die Ph.Eur.-Methode Phosphatpuffer verwendet. Dieser ist jedoch nicht flüchtig und daher für CAD ungeeignet. Es wurde daher versucht, den Puffer durch einen flüchtigen Puffer zu ersetzen. Da dies jedoch nicht zu befriedigenden Ergebnissen führte und vielmehr die Selbstzersetzung der verwendeten stationären Phase mit Hilfe der CAD beobachtet werden konnte, wurde auf alternative stationäre Phasen ausgewichen. Eine Auswahl von verschiedenen Säulen zeigte zudem weitere analytische Schwierigkeiten mit Acarbose und ihren Verunreinigungen: Sie zeigen die Epimerisierungsreaktion am Ende der Zuckeralkohole. Da man für jede Komponente einen Peak in den entsprechenden Chromatogrammen haben wollte, wurde die beschriebene Reaktion durch Temperaturerhöhung beschleunigt. Dies wurde am besten durch die 119 ZUSAMMENFASSUNG Verwendung mit folgenden stationären Phasen erreicht: PGC und Amid-HILIC. Auf jeder der beiden Phasen konnten Methoden zur Erfassung der Verunreinigungsprofile entwickelt werden. Darüber hinaus konnten erwartungsgemäß neue Verunreinigungen nachgewiesen werden, wenn auch auf niedrigem Niveau. Zwei von ihnen konnten durch „Spiking“-Experimente als die Zuckerfragmente Maltose und Maltotriose identifiziert werden. Zusammenfassend lässt sich sagen, dass diese Arbeit einen wesentlichen Beitrag zur Verbesserung der Qualitätsanalyse von monographierten Arzneimitteln geleistet hat. Zusätzlich zu dem vorgestellten allgemeinen Werkzeug zur Identifizierung potenzieller Verunreinigungen wurde eine der entwickelten Methoden bereits in die Ph. Eur. aufgenommen. In dem Versuch, die universellen Detektionsmöglichkeiten des CAD zu verbessern, wurden auch ergänzende Methoden entwickelt. Außerdem sind neue verbesserte Methoden für die Analyse von Verunreinigungsprofilen einsatzbereit. KW - Instrumentelle Analytik KW - HPLC KW - Chemische Reinheit KW - Charged Aerosol Detection KW - Impurity Profiling KW - Pharmaceutical Analysis Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-303318 ER - TY - JOUR A1 - Salgarella, Alice Rita A1 - Zahoranová, Anna A1 - Šrámková, Petra A1 - Majerčíková, Monika A1 - Pavlova, Ewa A1 - Luxenhofer, Robert A1 - Kronek, Juraj A1 - Lacík, Igor A1 - Ricotti, Leonardo T1 - Investigation of drug release modulation from poly(2-oxazoline) micelles through ultrasound JF - Scientific Reports N2 - Among external stimuli used to trigger release of a drug from a polymeric carrier, ultrasound has gained increasing attention due to its non-invasive nature, safety and low cost. Despite this attention, there is only limited knowledge about how materials available for the preparation of drug carriers respond to ultrasound. This study investigates the effect of ultrasound on the release of a hydrophobic drug, dexamethasone, from poly(2-oxazoline)-based micelles. Spontaneous and ultrasound-mediated release of dexamethasone from five types of micelles made of poly(2-oxazoline) block copolymers, composed of hydrophilic poly(2-methyl-2-oxazoline) and hydrophobic poly(2-n-propyl-2-oxazoline) or poly(2-butyl-2-oxazoline-co-2-(3-butenyl)-2-oxazoline), was studied. The release profiles were fitted by zeroorder and Ritger-Peppas models. The ultrasound increased the amount of released dexamethasone by 6% to 105% depending on the type of copolymer, the amount of loaded dexamethasone, and the stimulation time point. This study investigates for the first time the interaction between different poly(2-oxazoline)-based micelle formulations and ultrasound waves, quantifying the efficacy of such stimulation in modulating dexamethasone release from these nanocarriers. KW - Acoustics KW - Biomedical engineering KW - Drug delivery KW - Materials chemistry Y1 - 2018 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-227277 VL - 8 ER - TY - THES A1 - Schmidt, Sebastian T1 - A closer look at long-established drugs: enantioselective protein binding and stability studies T1 - Lang-etablierte Arzneistoffe genauer unter die Lupe genommen: Enantioselektive Proteinbindung und Stabilitätsstudien N2 - The aim of this work was to investigate older, established drugs. The extent of the protein binding of chiral ephedra alkaloids to AGP and of ketamine to albumin was determined. Since enantiomers of these drugs are individual available, the focus was on possible enantioselective binding and structural moieties involved in the binding. Previously published work suggested that ephedrine and pseudoephedrine can bind stereoselectively to proteins other than albumin in serum. For the determination of the extent of protein binding, the established ultrafiltration with subsequent chiral CE analysis was used. To determine the influence of basicity on binding, the drugs methylephedrine and norephedrine were also analyzed. Drug binding to AGP increased with increasing basicity as follows: norephedrine < methylephedrine < ephedrine < pseudoephedrine. pKaff was determined both graphically using the Klotz plot and mathematical indicating a low affinity of the ephedra alkaloids to AGP. Using STD-NMR spectroscopy experiments the aromatic protons and the C-CH3 side chain were shown to be most strongly involved in binding, which could be confirmed by molecular docking experiments in more detail. For all drugs, van der Waals-, π π , cationic interactions, hydrogen bonds, and a formation of a salt bridge were observed. The individual enantiomers showed no significant differences and thus the binding of ephedra alkaloids to AGP is not significant. In contrast to the ephedra alkaloids, the possible enantioselective binding to albumin was investigated for R and S ketamine. Again, ultrafiltration followed by CE analysis was performed. The binding of ketamine to one main binding site could be identified. A non-linear fit was used for the determination of pKaff. Using the NMR methods STD-NMR, waterLOGSY-NMR, and CPMG-NMRspectroscopy: the aromatic protons as well as the protons of the NCH3 methyl group showed the largest signal intensity changes, while the cyclohexanone protons showed the smallest changes. pKaff was also determined by the change in the chemical shift at different drug-protein ratios. These obtained values confirm the values obtained from ultrafiltration. Based on this, ketamine is classified as a low-affinity ligand to albumin. There were no significant differences between the individual enantiomers and thus the binding of ketamine to albumin is not a stereoselective process. Using statistical design of experiments an efficient chiral CE method for determining the extent of protein binding of R and S ketamine to albumin was developed and validated according to ICH Q2 (R1) guideline. The stability of ketamine was also investigated because a yellowish discoloration of an aqueous solution of ketamine developed under heat. XRPD investigations showed the same crystal structure for all batches examined. An untargeted screening using LC HRMS as well as LC UV measurements showed no degradation of ketamine or the presence of impurities in stress and non-stressed ketamine solutions, confirming the stability of ketamine under the stress conditions investigated. The lower the quality of the water used in the stress tests, the more intense the yellow discoloration occurred. The impurity or the mechanism that causes the yellow discoloration could not be identified. N2 - Ziel dieser Arbeit war es ältere, etablierte Arzneistoffe zu untersuchen. Das Ausmaß der Proteinbindung von chiralen Ephedra-Alkaloiden an AGP und von Ketamin an Albumin wurde bestimmt. Da Enantiomere dieser Wirkstoffe individuell verfügbar sind, lag der Fokus auf möglichen enantioselektiven Bindungen und strukturellen Funktionalitäten, die an der Bindung beteiligt sind. Zuvor veröffentlichte Arbeiten deuteten darauf hin, dass Ephedrin und Pseudoephedrin stereoselektiv an andere Proteine als Albumin im Serum binden können. Zur Bestimmung des Ausmaßes der Proteinbindung wurde die etablierte Ultrafiltration mit anschließender chiraler CE-Analyse eingesetzt. Um den Einfluss der Basizität auf die Bindung zu bestimmen, wurden auch die Wirkstoffe Methylephedrin und Norephedrin analysiert. Die Bindung des Wirkstoffs an AGP nahm mit zunehmender Basizität wie folgt zu: Norephedrin < Methylephedrin < Ephedrin < Pseudoephedrin. pKaff wurde sowohl grafisch mit Hilfe des Klotz-Plots als auch mathematisch bestimmt, was auf eine geringe Affinität der Ephedra-Alkaloide zu AGP hinweist. Mittels STD-NMR Spektroskopie Experimenten konnte gezeigt werden, dass die aromatischen Protonen und die C-CH3-Seitenkette am stärksten an der Bindung beteiligt sind, was durch molekulare Docking-Experimente detailliert bestätigt werden konnte. Für alle Wirkstoffe wurden van-der-Waals-, π π , kationische Wechselwirkungen, Wasserstoffbrückenbindungen und die Bildung einer Salzbrücke beobachtet. Die einzelnen Enantiomere zeigten keine signifikanten Unterschiede, so dass die Bindung von Ephedra-Alkaloiden an AGP nicht signifikant ist. Im Gegensatz zu den Ephedra-Alkaloiden wurde die mögliche enantioselektive Bindung an Albumin für R und S Ketamin untersucht. Auch hier wurde eine Ultrafiltration mit anschließender CE-Analyse durchgeführt. Die Bindung von Ketamin an eine Hauptbindungsstelle konnte identifiziert werden. Für die Bestimmung von pKaff wurde eine nichtlineare Anpassung verwendet. Mit den NMR-Methoden STD-NMR, waterLOGSY NMR und CPMG-NMR Spektroskopie zeigten sowohl die aromatischen Protonen als auch die Protonen der NCH3-Methylgruppe die größten Änderungen der Signalintensität, während die Cyclohexanon-Protonen die geringsten Änderungen afuwiesen. pKaff wurde auch durch die Änderung der chemischen Verschiebung bei verschiedenen Wirkstoff-Protein-Verhältnissen bestimmt. Die Werte bestätigen die durch die Ultrafiltration erhaltenen Werte. Auf dieser Grundlage wird Ketamin als Ligand mit niedriger Affinität zu Albumin eingestuft. Es zeigten sich keine signifikanten Unterschiede zwischen den einzelnen Enantiomeren und somit ist die Bindung von Ketamin an Albumin kein stereoselektiver Prozess. Mit Hilfe der statistischen Versuchsplanung wurde eine effiziente chirale CE-Methode zur Bestimmung des Ausmaßes der Proteinbindung von R und S Ketamin an Albumin entwickelt und gemäß der ICH Q2 (R1) Richtlinie validiert. Die Stabilität von Ketamin wurde ebenfalls untersucht, da sich unter Hitze eine gelbliche Verfärbung einer wässrigen Ketaminlösung entwickelte. XRPD-Untersuchungen zeigten für alle untersuchten Chargen die gleiche Kristallstruktur. Ein nicht zielgerichtetes Screening mittels LC HRMS sowie LC UV-Messungen zeigte keinen Abbau von Ketamin oder das Vorhandensein von Verunreinigungen in Stress- und nicht gestressten Ketaminlösungen, was die Stabilität von Ketamin unter den untersuchten Bedingungen bestätigt. Je schlechter die Qualität des in den Stresstests verwendeten Wassers war, desto intensiver trat die Gelbverfärbung auf. Die Verunreinigung oder der Mechanismus, der die gelbe Verfärbung verursacht, konnte nicht identifiziert werden. KW - Proteinbindung KW - Ephedrin KW - Ketamin KW - Stabilitätsstudien KW - Arzneistoffanalytik KW - Enantioselektivität Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-345945 ER - TY - THES A1 - Bach, Tobias T1 - Electromechanical interactions in lithium-ion batteries: Aging effects and analytical use T1 - Elektromechanische Wechselwirkungen in Lithium-Ionen Batterien: Alterungseffekte und analytische Anwendungsmöglichkeiten N2 - In the first part of his work, the causes for the sudden degradation of useable capacity of lithium-ion cells have been studied by means of complementary methods such as computed tomography, Post-Mortem studies and electrochemical analyses. The results obtained point unanimously to heterogeneous aging as a key-factor for the sudden degradation of cell capacity, which in turn is triggered by differences in local compression. At high states of health, the capacity fade rate is moderate but some areas of the graphite electrode degrade faster than others. Still, the localized changes are hardly noticeable on cell level due to averaging effects. Lithium plating occurs first in unevenly compressed areas, creating patterns visible to the human eye. As lithium plating leads to rapid consumption of active lithium, a sudden drop in capacity is observed on cell level. Lithium plating appears to spread out from the initial areas over the whole graphite electrode, quickly consuming the remaining useful lithium and active graphite. It can be hypothesized that a self-amplifying circle of reciprocal acceleration of local lithium loss and material loss causes rapid local degradation. Battery cell designers can improve cycle life by homogeneous pressure distribution in the cell and using negative active materials that are resilient to elevated discharge potentials such as improved carbons or lithium titanate. Also, a sufficiently oversized negative electrode and suitable electrolyte additives can help to avoid lithium plating. When packs are designed, care must be taken not to exert local pressure on parts of cells and to avoid both very high and low states of charge. In the second part of this dissertation the resilience of cylindrical and pouchbag cells to shocks and different vibrations was investigated. Stresses inflicted by vibration and shock tests according to the widely recognized UN38.3 transport test were compared to a long-time test that exposed cells to a 186 days long ordeal of sine sweep vibrations with a profile based on real-world applications. All cells passed visual and electric inspection performed by TU München after the vibration tests. Only cylindrical cells subjected to long-term vibrations in axial direction showed an increase in impedance and a loss of capacity that could be recuperated in part. The detailed analyses presented in this thesis gave more details on the damages inflicted by vibrations and shocks and revealed drastic damages in some cases. In cylindrical cells, only movement in axial direction caused damage. Long term vibrations were found to be especially detrimental. No damage whatsoever could be detected for pouch cells, regardless of the test protocol and the direction of movement. The extreme resilience of pouchbag cells shows that the electrode stack of lithium-ion cells is resistant to vibrations, and that damages are caused by design imperfections that can be improved at low cost. The findings of this work, and the general state of research show that it is most crucial to control the lithiation and thus potential of the graphite electrode. In the last part of this work, a new, direct method for charge estimation based on changing transmission is presented. A correlation between transmission of short ultrasonic pulses and state of charge is found. This new technology allows direct measurement of the state of charge. The method is demonstrated for batteries with different positive active materials, showing its versatility. As the observed changes can be traced to the lithiation of graphite, it can be determined without a reference electrode. Already at this early stage of development, the found correlations allow estimation of state of charge. The present hysteresis in the signal height of the slow wave, which is unneglectable especially during discharging at higher currents, will be subject to further investigation. The observed effects can be explained by effects on different length scales. Biot’s theory explains the second wave’s slowness based on the active material particles size in the range of 0.01 mm and electrolyte-filled pores. Lithiation of graphite changes the porosity of the electrode and thereby the velocity and wavelength of the impulse. When the wavelength approaches the length scale of the layers, 0.1 mm, scattering effects dampen the transmitted signal. Finally, the wavelength of the pulse should be shorter than the transducers diameter to obtain a homogeneous wave front. To conclude, the new method allows the control of each individual cell in a pack independent from the electrical connections of the cells. As the method shows great promise, further studies regarding factors such as long-term behavior, temperature and current rates should be conducted. In this thesis hysteresis was observed and a deeper understanding of the reasons behind it may allow further improvements of measurement precision. N2 - Im ersten Teil dieser Doktorarbeit wurden die Ursachen des plötzlichen Kapazitätseinbruchs von Lithium-Ionen Zellen untersucht. Die mittels sich ergänzender Methoden wie Röntgentomographie, Post-Mortem Untersuchungen und elektrochemischer Analysen gewonnenen Ergebnisse weisen darauf hin, dass heterogene Alterungseffekte eine Schlüsselrolle für den beschleunigten Kapazitätsverlust spielen. Die beobachteten Ungleichmäßigkeiten auf gealterten Elektroden konnten wiederum auf Kompressionsunterschiede zurückgeführt werden. Im frühen Alterungsstadium war zwar nur ein moderater Kapazitätsverlust zu verzeichnen, einige Bereiche der Graphitelektrode altern jedoch schneller als andere. Diese lokalen Alterungseffekte sind auf Zellebene aufgrund von Mittelungseffekten zunächst schwer nachweisbar, sobald jedoch in Bereichen abweichender Kompression Lithiumplating auftritt, entstehen Muster welche nach Öffnen der Zelle gut zu erkennen sind. Inaktives Lithium, dicke Passivschichten sowie erhöhte Mengen an abgelagertem Mangan und anderen Metallen die aus dem positiven Aktivmaterial herausgewaschen wurden, konnten in geschädigten Bereichen der Zellen B und C, welche direkt beim Einsetzen beziehungsweise 150 Zyklen später geöffnet wurden, nachgewiesen werden. Da Lithiumplating zu raschem Verbrauch von aktivem Lithium führt, kann ein plötzlicher Einbruch der Zellkapazität beobachtet werden. Das Lithiumplating scheint sich von den geschädigten Bereichen über die gesamte Elektrode auszubreiten, wobei rasch das verbleibende aktive Lithium und teilweise auch das negative Aktivmaterial verbraucht wird. Daher wird die Hypothese aufgestellt, dass durch lokales Lithiumplating ein sich selbst verstärkender Kreislauf in Gang gesetzt wird, wobei sich lokaler Lithium- und Aktivmaterialverlust gegenseitig beschleunigen. Im zweiten Teil der Arbeit wurde die Widerstandsfähigkeit von zylindrischen und Pouchbagzellen gegenüber Schocks und Vibrationen untersucht. Belastungen durch Vibrationen und Schocks gemäß des weitläufig anerkannten Transporttests UN38.3 wurden mit 186 Tage dauernden Langzeittests verglichen. Alle Zellen bestanden die visuellen und elektrischen Überprüfungen die an der TU München nach Durchführung der Vibrationstests durchgeführt wurden. Nur die zylindrischen Zellen zeigten einen Anstieg des Innenwiderstands sowie einen weitgehend reversiblen Kapazitätsverlust. Die in dieser Arbeit vorgestellte tiefergehenden Analysen gaben ein detaillierteres Bild der beobachteten Effekte auf und zeigten teilweise schwere versteckte Schäden auf, wobei ausschließlich in axialer Richtung belastete Rundzellen Schäden aufwiesen. Langzeitvibrationen führten zu besonders schweren Schadensbildern. An den untersuchten Pouchzellen konnte keinerlei Schädigung durch die Vibration festgestellt werden. Die Widerstandsfähigkeit der Pouchzellen zeigt, dass der Elektrodenstapel, der die Grundlage jeder Lithium-Ionen Zelle bildet, äußerst vibrationsstabil ist und auftretende Schäden auf ungenügendes Zelldesign zurückzuführen sind. Die hier vorgestellten Ergebnisse und der Stand der Wissenschaft zeigen die Bedeutung des Lithiierungsgrad der Graphitelektrode für die Alterung auf. Im letzten Teil der Arbeit wurde daher eine neue Methode zur Ladezustandsbestimmung mittels Ultraschall vorgestellt. Die beobachteten Amplituden- und Laufzeitänderungen erlauben die direkte Bestimmung des Ladezustands von Lithium-Ionen Zellen und die Anwendbarkeit konnte an Zellen mit verschiedenen positiven Aktivmaterialien gezeigt werden. Die beobachteten Effekte können auf Vorgänge auf verschiedenen Längenskalen zurückgeführt werden. Biots Theorie bietet eine Erklärung der geringen Geschwindigkeit der zweiten Welle aufgrund der Ausbreitungsmodi der Schallwellen im porösen, elektrolytgefüllten Aktivmaterial. Die im Vergleich zur Wellenlänge kleine Längenskala der Aktivpartikel und der elektrolytgefüllten Poren von 0,01 mm führt hierbei dazu, dass sich das Material als Effektivmedium verhält. Durch die Lithiierung der Graphitpartikel ändern sich Eigenschaften und Porosität der Elektrode. Insbesondere die Porositätsänderung kann laut Biots Theorie die Geschwindigkeit und somit die Wellenlänge der zweiten Welle wesentlich verändern. Wenn die Wellenlänge auf die Größenordnung der Schichtdicken der Zelle, 0,1 mm, reduziert wird, treten Streuungseffekte auf, die die transmittierte Welle abschwächen. Schlussendlich muss der Durchmesser der eingesetzten Schallwandler größer als die Wellenlänge der Pulse sein um ein homogenes Schallfeld zu erzeugen. Da der Einsatz von Ultraschallpulsen vielversprechend erscheint, sollten in weiteren Studien Faktoren wie Langzeitverhalten, Temperatur- und Rateneinflüsse untersucht werden. In dieser Arbeit wurde weiterhin Hysterese beobachtet deren tieferes Verständnis nicht nur die Ladezustandsbestimmung, sondern auch das Verständnis der dynamischen Prozesse in Lithium-Ionen Zellen verbessern könnte. KW - Lithium-Ionen-Akkumulator KW - Lithium-Plating KW - Alterung KW - Ultraschall KW - Ultraschallsensor KW - vibration testing KW - mechanical shock KW - heterogeneous compression Y1 - 2017 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-153325 ER - TY - THES A1 - Vogg, Nora Johanna T1 - Mass spectrometry-based quantification of steroids for the diagnostic workup of adrenal tumors T1 - Massenspektrometrische Quantifizierung von Steroiden zur Diagnostik von Nebennierentumoren N2 - Tumors of the adrenal gland belong to the most frequent neoplasms in humans with a prevalence of 3–10 % in adults. The aim of the diagnostic workup is the identification of potentially hormone-secreting and / or malignant tumors, because most of these tumors will require surgical resection. Malignant adrenocortical carcinomas (ACC) are very rare and associated with a poor prognosis in advanced stages, therefore, an early and accurate diagnosis is crucial. Within this thesis, two liquid chromatography tandem mass spectrometry (LC-MS/MS) methods for the quantification of steroids in different biomaterials were developed to improve the diagnostic workup of adrenal tumors. First, an LC-MS/MS method for the simultaneous quantification of cortisol and dexamethasone in serum samples after dexamethasone suppression test (DST) was developed, validated, and applied to 400 clinical samples. Newly established method-specific threshold concentrations for cortisol and dexamethasone increased DST specificity from 67.5 % to 92.4 % while preserving 100 % sensitivity. Second, an LC-MS/MS method for the quantification of eleven urinary steroids was developed and validated to improve the differentiation between ACC and adrenocortical adenomas (ACA). A decision tree requiring only two steroids was trained for classification and tested based on 24 h urine samples from 268 patients with adrenal tumor. Malignancy was excluded with a negative predictive value of 100 % in an independent validation cohort of 84 samples of 24-h urine. A newly proposed simplified diagnostic workflow with urinary steroid profiling as first tier test could obviate additional adrenal-specific imaging in 42 of 64 patients with ACA. The new DST method is already in clinical use at the University Hospital Würzburg, whereas the classification model based on urinary steroid profiling will require prospective validation in a larger cohort. N2 - Nebennierentumoren gehören zu den häufigsten Neoplasmen beim Menschen und treten mit einer Prävalenz von 3–10 % bei Erwachsenen über 50 Jahren auf. Häufig wird die Raumforderung zufällig im Rahmen einer bildgebenden Untersuchung erkannt. Die meisten dieser sogenannten Inzidentalome sind gutartige und hormoninaktive Nebennierenrindenadenome (ACA), die keine therapeutische Intervention erfordern. Das Ziel der Nebennierentumor-Diagnostik ist die Abklärung potentieller Hormonaktivität und Malignität, denn diese Tumoren müssen zum Großteil operativ entfernt werden. Hormonaktive Tumoren können benigne oder maligne sein und sind durch die autonome Sekretion von Steroidhormonen charakterisiert. Maligne Nebennierenrindenkarzinome (ACC) sind sehr selten, aber aggressiv und mit einer schlechten Prognose im fortgeschrittenen Tumorstadium assoziiert. Da die therapeutischen Möglichkeiten für das ACC limitiert sind, ist eine schnelle und sichere Diagnostik erforderlich. Im Rahmen dieser Doktorarbeit wurden zwei Flüssigchromatographie-Tandemmassenspektrometrie (LC-MS/MS) Methoden zur Quantifizierung von Steroiden in Biomaterialien entwickelt, um damit die Diagnostik von Nebennierentumoren zu verbessern. Der 1 mg-Dexamethason-Hemmtest (DST) ist ein häufig durchgeführter Screening-Test zur Untersuchung auf autonome Cortisolsekretion. Dabei wird die Supprimierbarkeit der Cortisolsekretion durch die orale Einnahme von Dexamethason überprüft. Eine LC-MS/MS Methode zur simultanen Quantifizierung von Cortisol und Dexamethason im Serum wurde entwickelt, validiert und zur Messung von 400 DST-Patientenproben genutzt. Durch methodenspezifische Schwellenwertkonzentrationen für Cortisol und Dexamethason konnte die klinische Testspezifität von 67.5 % auf 92.4 % bei unveränderter Sensitivität von 100.0 % erhöht werden. Der zweite Teil dieser Arbeit befasst sich mit der Verbesserung der Unterscheidung von ACC und ACA. Dafür wurde eine LC-MS/MS Methode zur Quantifizierung von elf Steroiden im Urin entwickelt und validiert. Über die Messung von 24 h Sammelurinproben von 268 Nebennierenrindentumor-Patienten wurde ein Klassifikationsmodell, das auf nur zwei Steroiden basiert, trainiert und getestet. Sowohl die analytische Methode als auch das Klassifikationsmodell wurden hinsichtlich Robustheit und Zeiteffizienz optimiert, um sich möglichst gut in die klinische Routine implementieren zu lassen. Außerdem lag der Fokus auf einer einfachen, nachvollziehbaren und direkten Datenauswertung und -interpretation. Als ein Hauptergebnis konnte Malignität in einer unabhängigen Validierungskohorte von 84 Patienten mit einem negativen prädiktiven Wert von 100 % ausgeschlossen werden. Nach einem vereinfachten diagnostischen Schema mit der Urin-Steroid-Analytik als erstem Screening-Test könnte bei 42 von 64 Patienten mit ACA auf eine zusätzliche nebennierenspezifische Bildgebung verzichtet werden. Des Weiteren wurden erstmals Spontanurinproben als Surrogatmatrix für 24 h Sammelurin in der Validierungskohorte getestet. Dabei unterschied sich der positive prädiktive Wert der Spontanurine mit 86.7 % kaum von den 87.5 % der 24-h Sammelurine, während auch mit Spontanurin ein negativer prädiktiver Wert von 100 % erzielt werden konnte, was einen wichtigen Schritt in die Richtung einer vereinfachten Probensammlung darstellt. Sowohl die simultane Quantifizierung von Cortisol und Dexamethason als auch die 24-h Urin-Steroid-Methode haben ihre Eignung für die klinische Routineanwendung bewiesen. Der Transfer der Urinmethode auf den deutlich einfacheren Spontanurin erfordert jedoch eine prospektive Validierung in einer größeren Patientenkohorte. Die neue DST-Methode wurde bereits im September 2021 in die klinische Routine am Universitätsklinikum Würzburg eingeführt. KW - Nebennierentumor KW - HPLC-MS KW - Steroide KW - adrenal incidentaloma KW - adrenocortical carcinoma KW - adrenocortical adenoma KW - dexamethasone suppression test Y1 - 2023 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:bvb:20-opus-293438 N1 - A revised version of this manuscript has been published in Clinica Chimica Acta 2023 ER -