Refine
Has Fulltext
- yes (14)
Is part of the Bibliography
- yes (14)
Year of publication
Document Type
- Journal article (13)
- Doctoral Thesis (1)
Keywords
- Medizin (4)
- Radiosurgery (3)
- Stereotactic body radiotherapy (2)
- spine radiosurgery (2)
- vertebral metastases (2)
- ACR practice guidelines (1)
- Couch tracking (1)
- Extended field irradiation (1)
- Follicular lymphoma (1)
- Frame-based (1)
- Frame-less (1)
- Genom (1)
- Gimbaled tracking (1)
- Head and neck cancer (1)
- Hitzeschock (1)
- Image-guidance (1)
- Locoregional recurrence (1)
- MLC tracking (1)
- Microarray (1)
- NSCLC (1)
- Neisseria (1)
- Normal tissue tolerance (1)
- Organ motion (1)
- Pain (1)
- Pelvic tumors (1)
- Phase II trial (1)
- Re-irradiation (1)
- Robotic tracking (1)
- Spinal metastases (1)
- Spinal metastasis (1)
- Stereotactic (1)
- Strahlentherapie (1)
- Total nodal irradiation (1)
- advanced technology (1)
- cancer (1)
- clinical trials (1)
- cone beam CT (1)
- conformal radiotherapy (1)
- credentialing (1)
- cyberknife radiosurgery (1)
- delineation (1)
- dose escalation (1)
- heat (1)
- high-dose-rate brachytherapy boost (1)
- hypofractionation (1)
- image-guided radiation therapy (1)
- intensity modulated radiotherapy (1)
- intensity-modulated radiation therapy (1)
- intensity-modulated radiotherapy (1)
- long-term outcome (1)
- megavoltage computed-tomography (1)
- meningitidis (1)
- methods (1)
- paraspinal tumors (1)
- planning variability (1)
- propensity score matching (1)
- quality assurance (1)
- questionnaire (1)
- radiation therapy (1)
- risk (1)
- shock (1)
- simultaneous integrated boost (1)
- spine Radiosurgery (1)
- spine tumors (1)
- stereotactic body radiotherapy (1)
- strategies (1)
- toxicity (1)
- variability (1)
Purpose: A study of real-time adaptive radiotherapy systems was performed to test the hypothesis that, across delivery systems and institutions, the dosimetric accuracy is improved with adaptive treatments over non-adaptive radiotherapy in the presence of patient-measured tumor motion. Methods and materials: Ten institutions with robotic(2), gimbaled(2), MLC(4) or couch tracking(2) used common materials including CT and structure sets, motion traces and planning protocols to create a lung and a prostate plan. For each motion trace, the plan was delivered twice to a moving dosimeter; with and without real-time adaptation. Each measurement was compared to a static measurement and the percentage of failed points for gamma-tests recorded. Results: For all lung traces all measurement sets show improved dose accuracy with a mean 2%/2 mm gamma-fail rate of 1.6% with adaptation and 15.2% without adaptation (p < 0.001). For all prostate the mean 2%/2 mm gamma-fail rate was 1.4% with adaptation and 17.3% without adaptation (p < 0.001). The difference between the four systems was small with an average 2%/2 mm gamma-fail rate of <3% for all systems with adaptation for lung and prostate. Conclusions: The investigated systems all accounted for realistic tumor motion accurately and performed to a similar high standard, with real-time adaptation significantly outperforming non-adaptive delivery methods.