Refine
Has Fulltext
- yes (25)
Is part of the Bibliography
- yes (25)
Year of publication
Document Type
- Journal article (24)
- Conference Proceeding (1)
Language
- English (25)
Keywords
- PRRT (6)
- dosimetry (6)
- 53BP1 (3)
- γ-H2AX (3)
- 177Lu (2)
- CXCR4 (2)
- PET/CT (2)
- biodosimetry (2)
- chemokine receptor (2)
- neuroendocrine tumor (2)
- positron emission tomography (2)
- quantitative SPECT/CT (2)
- repair (2)
- 131I (1)
- 133Ba (1)
- 177Lu SPECT/CT imaging (1)
- 177Lu-DOTATATE (1)
- 177Lu-DOTATOC (1)
- 223Ra (1)
- 224Ra (1)
- 3D printing (1)
- 5IA-SPECT (1)
- BSS directive (1)
- Barium-133 (1)
- Biokinetics (1)
- Combination (1)
- DNA Breaks (1)
- DNA damage (1)
- DNA double-strand breaks (1)
- DNA repair (1)
- DOTATOC (1)
- DSB damage (1)
- DSB focus substructure (1)
- Deep learning (1)
- Denoising (1)
- Diagnostic radiopharmaceuticals (1)
- Dosimetry (1)
- EANM dosage card (1)
- EBRT (1)
- Effective dose (1)
- Ga-68 (1)
- JR11 (1)
- Lu-177 (1)
- Lutetium (1)
- MAG3 (1)
- Medizin (1)
- Meningioma (1)
- Monte Carlo (1)
- Neuroendocrine Tumor (1)
- OPS201 (1)
- PET (1)
- PET/MR systems (1)
- PSMA (1)
- Parkinson disease (1)
- Peptide receptor radionuclide therapy (1)
- Positronen-Emissions-Tomografie (1)
- Ra-224 (1)
- Radiotherapy (1)
- Radium (1)
- SPECT (1)
- SPECT/CT (1)
- SSTR (1)
- Single Molecule Localization Microscopy (SMLM) (1)
- [\(^{68}\)Ga]Pentixafor (1)
- \(^{177}\)Lu-OPS201 (1)
- absorbed dose to the blood (1)
- acute myeloid leukemia (1)
- alpha particles (1)
- alpha-emitters (1)
- antagonist (1)
- biokinetics (1)
- biological dosimetry (1)
- biomarkers (1)
- blood (1)
- bone-targeting radiopharmaceuticals (1)
- calibration (1)
- cancer treatment (1)
- chromatin mobility (1)
- cognitive decline (1)
- comparison exercise (1)
- complex DNA damage (1)
- contrast agent (1)
- damage (1)
- dopamine acetylcholine (1)
- dose response (1)
- double-stranded (1)
- epidemiology (1)
- gamma rays (1)
- harmonization of SPECT/CT imaging (1)
- health care (1)
- healthy volunteers (1)
- high LET irradiation (1)
- histone H2AX (1)
- humans (1)
- in vivo formation (1)
- in vivo imaging (1)
- international multicenter comparison exercise (1)
- irradiation (1)
- isotopes (1)
- leukocytes (1)
- lutetium-177 (1)
- lymphoma (1)
- medicine (1)
- molecular radiotherapy (1)
- molecular radiotherapy (MRT) (1)
- multi-centre (1)
- neuroendocrine tumor (NET) (1)
- neuroendocrine tumors (1)
- nicotinic receptors (1)
- nuclear medicine (1)
- nuclear medicine therapy (1)
- optimization (1)
- peptide receptor radionuclide therapy (1)
- phantom (1)
- phosphorylation (1)
- photons (1)
- pig model (1)
- prognostic value (1)
- prostate cancer (1)
- quantitative imaging (1)
- radiation effects (1)
- radiobiology (1)
- radioiodine (1)
- radioiodine therapy (1)
- radionuclide therapy (1)
- radium (1)
- renal scintigraphy (1)
- signal to noise ratio (1)
- solid surrogate source (1)
- standardization of SPECT/CT imaging (1)
- super ultraviolet (1)
- theranostics (1)
- therapeutic target (1)
- thyroid cancer (1)
- thyroid carcinomas (1)
- traceability of SPECT/CT imaging (1)
- α-Particle (1)
- α-emitter (1)
Institute
Sonstige beteiligte Institutionen
EU-Project number / Contract (GA) number
- 701983 (2)
Introduction
Commissioning, calibration, and quality control procedures for nuclear medicine imaging systems are typically performed using hollow containers filled with radionuclide solutions. This leads to multiple sources of uncertainty, many of which can be overcome by using traceable, sealed, long-lived surrogate sources containing a radionuclide of comparable energies and emission probabilities. This study presents the results of a quantitative SPECT/CT imaging comparison exercise performed within the MRTDosimetry consortium to assess the feasibility of using 133Ba as a surrogate for 131I imaging.
Materials and methods
Two sets of four traceable 133Ba sources were produced at two National Metrology Institutes and encapsulated in 3D-printed cylinders (volume range 1.68–107.4 mL). Corresponding hollow cylinders to be filled with liquid 131I and a mounting baseplate for repeatable positioning within a Jaszczak phantom were also produced. A quantitative SPECT/CT imaging comparison exercise was conducted between seven members of the consortium (eight SPECT/CT systems from two major vendors) based on a standardised protocol. Each site had to perform three measurements with the two sets of 133Ba sources and liquid 131I.
Results
As anticipated, the 131I pseudo-image calibration factors (cps/MBq) were higher than those for 133Ba for all reconstructions and systems. A site-specific cross-calibration reduced the performance differences between both radionuclides with respect to a cross-calibration based on the ratio of emission probabilities from a median of 12–1.5%. The site-specific cross-calibration method also showed agreement between 133Ba and 131I for all cylinder volumes, which highlights the potential use of 133Ba sources to calculate recovery coefficients for partial volume correction.
Conclusion
This comparison exercise demonstrated that traceable solid 133Ba sources can be used as surrogate for liquid 131I imaging. The use of solid surrogate sources could solve the radiation protection problem inherent in the preparation of phantoms with 131I liquid activity solutions as well as reduce the measurement uncertainties in the activity. This is particularly relevant for stability measurements, which have to be carried out at regular intervals.