Refine
Has Fulltext
- yes (79)
Is part of the Bibliography
- yes (79)
Year of publication
Document Type
- Journal article (63)
- Doctoral Thesis (14)
- Master Thesis (1)
- Report (1)
Keywords
- Hadron-Hadron scattering (experiments) (17)
- hadron-hadron scattering (15)
- High energy physics (14)
- systematic uncertainty (9)
- jet energy scale (7)
- Higgs physics (5)
- high energy physics (5)
- transverse momentum (5)
- jet energy resolution (4)
- ATLAS (3)
- Atlas detector (3)
- MC simulation (3)
- SM background (3)
- jet energy scale uncertainty (3)
- light quark jet (3)
- multijet background (3)
- non-prompt lepton (3)
- top quark mass (3)
- top quark pair (3)
- (Ga,Mn)As (2)
- ATLAS detector (2)
- Anti-k Jet (2)
- Beyond Standard Model (2)
- Cl Lowe limit (2)
- Exotics (2)
- Galliumarsenid (2)
- JES uncertainty (2)
- MC event generator (2)
- Manganarsenide (2)
- Nernst-Effekt (2)
- Organischer Halbleiter (2)
- Pp Collision (2)
- Quantenpunkt (2)
- Seebeck-Effekt (2)
- Spintronik (2)
- acceptance time efficiency (2)
- anti-k jet (2)
- fake lepton (2)
- jet channel (2)
- jet reconstruction efficiency (2)
- jet transverse momentum (2)
- multi-jet background (2)
- muon channel (2)
- partial decay width (2)
- primary vertex (2)
- signal cross section (2)
- simulated signal event (2)
- single top event (2)
- single top production (2)
- single top quark (2)
- single top quark production (2)
- top quark decay (2)
- visible cross section (2)
- 7000 GeV-cms (1)
- ARPES (1)
- ATLAS <Teilchendetektor> (1)
- Actinoide (1)
- Adaptive Optics (1)
- Adaptive Optik (1)
- B physics (1)
- B-tagged jet (1)
- Blazar (1)
- Bose gas (1)
- Bose-Fermi (1)
- CERN LHC Coll (1)
- CT (1)
- Caloritronic (1)
- Chiral-sensitive Specktroskopie (1)
- Chiralität <Chemie> (1)
- DMS (1)
- Einzelmolekülmikroskopie (1)
- Einzelphotonenemission (1)
- Electroweak interaction (1)
- Elektrooptische Eigenschaft (1)
- Experimentelle Bildgebung (1)
- Fabrication (1)
- Femtosekundenspektroskopie (1)
- Fermi liquid (1)
- Flavour changing neutral currents (1)
- Fotovoltaik (1)
- GMSB model (1)
- Gammastrahlung (1)
- Giant Zeeman splitting (1)
- Hadron Hadron scattering (experiments) (1)
- Hadron-Hadron Scattering (1)
- Herstellung (1)
- HgTe (1)
- Hidden-Order of URu2Si2 (1)
- Higgs boson signal (1)
- Hochenergieastronomie (1)
- II-VI (1)
- Interbandübergang (1)
- Intermediate Band Solar Cell (1)
- Interventionelle Radiologie (1)
- Interventionsradiologie (1)
- JES (1)
- Jet physics (1)
- Kaloritronik (1)
- Kosmische Strahlung (1)
- Large Hadron Collider (1)
- Leerlaufspannung (1)
- Leptoquark (1)
- Lichtsensor (1)
- MC expectation (1)
- MC program (1)
- MPI (1)
- MPI <Bildgebendes Verfahren> (1)
- Magnetic Particle Imaging (1)
- Magnetische Eigenschaft (1)
- Magnetpartikelbildgebung (1)
- Mathematisches Modell (1)
- Medizinische Radiologie (1)
- Monte Carlo (1)
- Monte Carlo methods (1)
- Nanoröhre (1)
- Nanostructures (1)
- Nanostruktur (1)
- Nernst effect (1)
- Nukleosynthese (1)
- ODMR-Spektroskopie (1)
- Organische Solarzelle (1)
- PDF set (1)
- Particle Physics (1)
- Phasenumwandlung (1)
- Polarimetrie (1)
- QCD background (1)
- QD-IBSC (1)
- Quantenstatistik (1)
- Quantum Mechanics (1)
- Quecksilbertellurid (1)
- ROI (1)
- RTD (1)
- Rauschen (1)
- Rekombination (1)
- Resonanz-Tunneldiode (1)
- Resonanztunneldiode (1)
- Röntgenstrahlung (1)
- SM Background (1)
- SUSY breaking scale (1)
- Seebeck effect (1)
- Siliciumcarbid (1)
- Single Molecule Localization Microscopy (1)
- Solarzelle (1)
- Spintronic (1)
- Statistical Physics (1)
- Stochastische Resonanz (1)
- Strahlung (1)
- Störstellen (1)
- Supernova (1)
- Supersymmetry (1)
- TAMT (1)
- Top physics (1)
- Topologischer Isolator (1)
- Transluminale Angioplastie (1)
- Traveling Wave Magnetic Particle Imaging (1)
- Trigger System (1)
- Tunneldiode (1)
- Ultrakurzzeitspektroskopie (1)
- Ultraschnelle Photochemie (1)
- VMH (1)
- Verbindungen (1)
- WZ production (1)
- X-ray (1)
- X-rays (1)
- Zirkulardichroismus Spektroskopie (1)
- Zwei-Sechs-Halbleiter (1)
- Zwischenbandsolarzelle (1)
- additional jet (1)
- anomaly mediation (1)
- artificial atom (1)
- background (1)
- background cross section (1)
- background expectation (1)
- brain swelling (1)
- calorimeter (1)
- calorimeter response (1)
- charge misidentification (1)
- charged hadron response (1)
- chargino --> neutralino pi (1)
- chargino decay (1)
- chargino lifetime (1)
- chargino mass (1)
- charingo mass (1)
- chemistry (1)
- chiral boson (1)
- chirality-sensitive spectroscopy (1)
- circular dichroism spectroscopy (1)
- computed tomography (1)
- cosmic rays (1)
- coupling strength (1)
- cross section measurement (1)
- cross section time (1)
- dSTORM (1)
- dead region (1)
- decay channels (1)
- detector track (1)
- diffractive dissociation (1)
- dilepton channel (1)
- dilepton invariant mass (1)
- dilepton invariant mass, (1)
- dilepton mass (1)
- diluted magnetic semiconductor (1)
- diphoton invariant mass (1)
- direct pair production (1)
- dissociation process, (1)
- dry etching (1)
- electron beam lithography (1)
- electron energy deposition (1)
- electroweak background (1)
- energy scale (1)
- energy scale uncertainty (1)
- event selcetion cut (1)
- event shape observable (1)
- event shape variable (1)
- experimental cerebral malaria (1)
- experimental imaging (1)
- experimental physics (1)
- experimental results (1)
- experimental systematic uncertainty (1)
- extrapolation factor (1)
- fabrication (1)
- femtosecond spectroscopy (1)
- fiducial cross section (1)
- flavour changing (1)
- gamma rays (1)
- good agreement (1)
- hadron hadron scattering (1)
- hadronic calorimeter (1)
- hadronic final state (1)
- hadronic physics (1)
- hadronisation model (1)
- heavy fermions (1)
- heavy flavour (1)
- heavy flavour quark (1)
- heavy neutrino (1)
- helicity fraction (1)
- heterostructure (1)
- hidden-order (1)
- high jet multiplicity (1)
- holotomography (1)
- identified particle response (1)
- inclusive jet sample (1)
- individual systematic uncertainty (1)
- insulator (1)
- interventional radiology (1)
- invariant mass (1)
- invariant mass distribution (1)
- invariant mass resolution (1)
- isolation requirement (1)
- jet axis (1)
- jet background (1)
- jet calibration (1)
- jet cross section (1)
- jet energy (1)
- jet energy measurement (1)
- jet multiplicity (1)
- jet response (1)
- jet sample (1)
- jet scale energy (1)
- large rapidity gap (1)
- lepton flavour (1)
- leptonic final state (1)
- light-matter coupling (1)
- magnetic fields (1)
- magnetic particle imaging (1)
- molecular beam epitaxy (1)
- momentum scale (1)
- multijet event (1)
- multiscalar holotomography (1)
- muon decay channel (1)
- muon reconstruction efficiency (1)
- muon spectrometer (1)
- nanocavities (1)
- nanophotonics and plasmonics (1)
- neutral Higgs boson (1)
- neutral currents (1)
- noise (1)
- nucleosynthesis (1)
- open circuit voltage (1)
- organic solar cells (1)
- organische Solarzellen (1)
- pair invariant mass (1)
- particle level jet (1)
- parton shower (1)
- photo detector (1)
- photoelectron spectroscopy (1)
- photon energy scale (1)
- photonic devices (1)
- polarimetry (1)
- pp collision (1)
- pp collisions (1)
- producation cross section (1)
- production cross section (1)
- pythia parton shower (1)
- quantum center (1)
- quantum criticality (1)
- quantum dot (1)
- quantum spin Hall effect (1)
- quantum transport (1)
- quartic gauge couplings (QGCs) (1)
- rapidity interval (1)
- rare decays (1)
- recombination (1)
- reconstructed mass spectrum (1)
- reconstruction (1)
- region of interest (1)
- resonant tunneling diode (1)
- rostral-migratory-stream (1)
- scattering (1)
- sequential standard model (1)
- signal template (1)
- simulaed event sample (1)
- simulated event sample (1)
- sparticle cascade decay (1)
- sparticle pair production (1)
- stochastic resonance (1)
- supernovae (1)
- supersymmetry (1)
- symmetry breaking (1)
- systematic effect (1)
- top event dilepton invariant mass (1)
- top physics (1)
- top quark (1)
- top quark contribution (1)
- top quark masse (1)
- topological insulator (1)
- total systematic uncertainty (1)
- track data analysis (1)
- track momentum (1)
- track multipilicty (1)
- transport data (1)
- transverse momentum momentum spectrum (1)
- transverse momentum vector (1)
- transverse plane (1)
- trap states (1)
- traveling wave magnetic particle imaging (1)
- triboson production (1)
- triple gauge couplings (TGCs) (1)
- ultrafast photochemistry (1)
- unconverted photon (1)
- underlying event tune (1)
- validation region (1)
Institute
- Fakultät für Physik und Astronomie (79) (remove)
Sonstige beteiligte Institutionen
EU-Project number / Contract (GA) number
- 614623 (1)
Magnetic Particle Imaging (MPI) ist ein innovatives tomographisches Bildgebungsverfahren, mit dem Tracerpartikel äußerst sensitiv und schnell mehrdimensional abgebildet werden können. Die Methode basiert auf der nichtlinearen Magnetisierungsantwort superparamagnetischer Eisenoxidnanopartikel (SPION) in einem Messpunkt, welcher ein Messvolumen rastert. In vorliegender Arbeit wurde das sog. Traveling Wave MPI (TWMPI) Verfahren eingesetzt, wodurch im Vergleich zu konventionellen MPI-Scannern ein größeres Field of View (FOV) und eine geringere Latenz bis zur Bildanzeige erreicht werden konnte. TWMPI weist einige für medizinische Zwecke vielversprechende Eigenschaften auf: Es liefert zwei- und dreidimensionale Bildrekonstruktionen in Echtzeit mit hoher zeitlicher und räumlicher Auflösung. Dabei ist die Bildgebung von Grund auf hintergrundfrei und erfordert keinerlei ionisierende Strahlung. Zudem ist die Technik äußerst sensitiv und kann SPION-Tracer noch in mikromolaren Konzentrationen detektieren.
Ziel dieser Arbeit war es daher zu untersuchen, inwiefern es mittels TWMPI möglich ist, künstliche Stenosen im Gefäßmodell visuell in Echtzeit darzustellen und quantitativ zu beurteilen sowie überdies eine perkutane transluminale Angioplastie (PTA) im Gefäßmodell unter TWMPI-Echtzeit-Bildgebung durchzuführen.
Alle Experimente wurden in einem speziell angefertigten TWMPI-Scanner durchgeführt (JMU Würzburg, Experimentelle Physik V (Biophysik), FOV: 65 x 29 x 29 mm³, Auflösung: ca. 1.5 - 2 mm). Die Lumen-Darstellungen erfolgten mittels des SPION-Tracers Ferucarbotran in einer Verdünnung von 1 : 50 (entspr. 10 mmol [Fe]/l). Das PTA-Instrumentarium wurde mit eigens hergestelltem ferucarbotranhaltigem Lack (100 mmol [Fe]/l) markiert. Für die verschiedenen Teilexperimente wurden den jeweiligen speziellen Anforderungen entsprechend mehrere Gefäßmodelle handgefertigt.
Für die visuelle Stenosequantifizierung wurden fünf starre Stenosephantome unterschiedlicher Stenosierung (0%, 25%, 50%, 75%, 100%) aus Polyoxymethylen hergestellt (l: 40 mm, ID: 8 mm). Die Gefäßmodelle wurden mehrfach zentral im FOV platziert und das stenosierte Lumen mittels sog. Slice-Scanning Modus (SSM, Einzelaufnahme inkl. 10 Mittelungen: 200 ms, Bildfrequenz: 5 Bilder pro Sekunde, Latenz: ca. 100 ms) als zweidimensionale Quasi-Projektionen abgebildet. Diese Aufnahmen (n = 80, 16 je Phantom) wurden mit einer einheitlichen Grauskalierung versehen und anschließend entsprechend den NASCET-Kriterien visuell ausgewertet.
Alle achtzig Aufnahmen waren unabhängig vom Stenosegrad aufgrund einheitlicher Fensterung sowie konstanter Scannerparameter untereinander gut vergleichbar. Niedriggradige Stenosen konnten insgesamt genauer abgebildet werden als höhergradige, was sich neben der subjektiven Bildqualität auch in geringeren Standardabweichungen zeigte (0%: 3.70 % ± 2.71, 25%: 18.64 % ± 1.84, 50%: 52.82 % ± 3.66, 75%: 77.84 % ± 14.77, 100%: 100 % ± 0). Mit zunehmendem Stenosegrad kam es vermehrt zu geometrischen Verzerrungen im Zentrum, sodass bei den 75%-Stenosen eine breitere Streuung der Messwerte mit einer höheren Standardabweichung von 14.77% einherging. Leichte, randständige Artefakte konnten bei allen Datensätzen beobachtet werden.
Für die PTA wurden drei interaktive Gefäßmodelle aus Polyvinylchlorid (l: 100 mm, ID: 8 mm) mit zu- und abführendem Schlauchsystem entwickelt, welche mittels Kabelband von außen hochgradig eingeengt werden konnten. Analog zu einer konventionellen PTA mittels röntgenbasierter digitaler Subtraktionsangiographie (DSA), wurden alle erforderlichen Arbeitsschritte (Gefäßdarstellung, Drahtpassage, Ballonplatzierung, Angioplastie, Erfolgskontrolle) unter (TW)MPI-Echtzeit-Bildgebung (Framerate: 2 - 4 FPS, Latenz: ca. 100 ms) abgebildet bzw. durchgeführt.
Im Rahmen der PTA war eine Echtzeit-Visualisierung der Stenose im Gefäßmodell durch Tracer-Bolusgabe sowie die Führung des markierten Instrumentariums zum Zielort möglich. Die Markierung der Instrumente hielt der Beanspruchung während der Prozedur stand und ermöglichte eine genaue Platzierung des Ballonkatheters. Die Stenose konnte mittels Angioplastie-Ballons unter Echtzeit-Darstellung gesprengt werden und der Interventionserfolg im Anschluss durch erneute Visualisierung des Lumens validiert werden.
Insgesamt zeigt sich MPI somit als adäquate Bildgebungstechnik für die beiden in der Fragestellung bzw. Zielsetzung definierten experimentellen Anwendungen. Stenosen im Gefäßmodell konnten erfolgreich in Echtzeit visualisiert und bildmorphologisch nach NASCET-Kriterien quantifiziert werden. Ebenso war eine PTA im Gefäßmodell unter TWMPI-Echtzeit-Bildgebung machbar. Diese Ergebnisse unterstreichen das grundlegende Potenzial von MPI für medizinische Zwecke. Um zu den bereits etablierten Bildgebungsmethoden aufzuschließen, ist jedoch weitere Forschung im Bereich der Scanner-Hard- und -Software sowie bezüglich SPION-Tracern nötig.