Refine
Has Fulltext
- yes (39)
Is part of the Bibliography
- yes (39)
Year of publication
Document Type
- Journal article (24)
- Doctoral Thesis (7)
- Conference Proceeding (5)
- Preprint (3)
Keywords
- PET (39) (remove)
Institute
- Klinik und Poliklinik für Nuklearmedizin (33)
- Medizinische Klinik und Poliklinik I (8)
- Medizinische Klinik und Poliklinik II (6)
- Graduate School of Life Sciences (3)
- Institut für Anatomie und Zellbiologie (2)
- Institut für Pharmakologie und Toxikologie (2)
- Neurologische Klinik und Poliklinik (2)
- Institut für Pharmazie und Lebensmittelchemie (1)
- Institut für Theoretische Physik und Astrophysik (1)
- Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I) (1)
- Klinik und Poliklinik für Mund-, Kiefer- und Plastische Gesichtschirurgie (1)
- Neurochirurgische Klinik und Poliklinik (1)
- Pathologisches Institut (1)
- Physiologisches Institut (1)
Sonstige beteiligte Institutionen
- Johns Hopkins School of Medicine (9)
- Johns Hopkins School of Medicine, Baltimore, MD, U.S. (2)
- Johns Hopkins University School of Medicine (2)
- Hospital Augsburg, Augsburg, Germany (1)
- Johns Hopkins University School of Medicine, Baltimore, MD, U.S. (1)
- Johns Hopkins University, Baltimore, MD, U.S. (1)
- Johns Hopkis School of Medicine (1)
Das orale Plattenepithelkarzinom zählt zu den häufigen Krebserkrankungen in Deutschland. Das Vorhandensein von zervikalen Lymphknotenmetastasen ist dabei einer der wichtigsten prognostischen Faktoren.
Für die Therapieplanung ist eine zuverlässige präoperative Diagnostik unerlässlich. Etablierte bildgebende Stagingverfahren (Sonographie, MRT, CT) orientieren sich allein an morphologischen Kriterien. Die PET/CT verspricht durch die Kombination funktioneller und morphologischer Verfahren die Detektion lymphoregionärer Metastasen. Ein weiterer Vorteil scheint der Nachweis simultaner Zweitmalignome und Fernmetastasen zu sein.
135 Patienten mit einem primären oralen Plattenepithelkarzinom erhielten im Rahmen der präoperativen Staginguntersuchungen eine PET/CT-Untersuchung. Untersucht wurde der korrekte Nachweis (Sensitivität) bzw. Ausschluss (Spezifität) zervikaler Lymphknotenmetastasen sowie die Detektion (Trefferquote) von simultanen Zweitmalignomen durch die PET/CT.
Die PET/CT zeigte eine Sensitivität von 82,9 % und eine Spezifität von 84 %. Simultane Zweitmalignome wurden mit einer Trefferquote von 62,5 % durch die PET/CT erkannt.
Das diagnostische Potenzial konnte in unserer Studie bestätigt werden. Vergleichende Studien zu den etablierten bildgebenden Verfahren wären wünschenswert.
(1) Background: We aimed to quantitatively investigate [\(^{68}\)Ga]Ga-FAPI-04 uptake in normal organs and to assess a relationship with the extent of FAPI-avid tumor burden. (2) Methods: In this single-center retrospective analysis, thirty-four patients with solid cancers underwent a total of 40 [\(^{68}\)Ga]Ga-FAPI-04 PET/CT scans. Mean standardized uptake values (SUV\(_{mean}\)) for normal organs were established by placing volumes of interest (VOIs) in the heart, liver, spleen, pancreas, kidneys, and bone marrow. Total tumor burden was determined by manual segmentation of tumor lesions with increased uptake. For tumor burden, quantitative assessment included maximum SUV (SUV\(_{max}\)), tumor volume (TV), and fractional tumor activity (FTA = TV × SUV\(_{mean}\)). Associations between uptake in normal organs and tumor burden were investigated by applying Spearman's rank correlation coefficient. (3) Results: Median SUV\(_{mean}\) values were 2.15 in the pancreas (range, 1.05–9.91), 1.42 in the right (range, 0.57–3.06) and 1.41 in the left kidney (range, 0.73–2.97), 1.2 in the heart (range, 0.46–2.59), 0.86 in the spleen (range, 0.55–1.58), 0.65 in the liver (range, 0.31–2.11), and 0.57 in the bone marrow (range, 0.26–0.94). We observed a trend towards significance for uptake in the myocardium and tumor-derived SUV\(_{max}\) (ρ = 0.29, p = 0.07) and TV (ρ = −0.30, p = 0.06). No significant correlation was achieved for any of the other organs: SUV\(_{max}\) (ρ ≤ 0.1, p ≥ 0.42), TV (ρ ≤ 0.11, p ≥ 0.43), and FTA (ρ ≤ 0.14, p ≥ 0.38). In a sub-analysis exclusively investigating patients with high tumor burden, significant correlations of myocardial uptake with tumor SUV\(_{max}\) (ρ = 0.44; p = 0.03) and tumor-derived FTA with liver uptake (ρ = 0.47; p = 0.02) were recorded. (4) Conclusions: In this proof-of-concept study, quantification of [\(^{68}\)Ga]Ga-FAPI-04 PET showed no significant correlation between normal organs and tumor burden, except for a trend in the myocardium. Those preliminary findings may trigger future studies to determine possible implications for treatment with radioactive FAP-targeted drugs, as higher tumor load or uptake may not lead to decreased doses in the majority of normal organs.
Aim
Recent advancements in PET technology have brought with it significant improvements in PET performance and image quality. In particular, the extension of the axial field of view of PET systems, and the introduction of semiconductor technology into the PET detector, initially for PET/MR, and more recently available long-field-of-view PET/CT systems (≥ 25 cm) have brought a step change improvement in the sensitivity of PET scanners. Given the requirement to limit paediatric doses, this increase in sensitivity is extremely welcome for the imaging of children and young people. This is even more relevant with PET/MR, where the lack of CT exposures brings further dose reduction benefits to this population. In this short article, we give some details around the benefits around new PET technology including PET/MR and its implications on the EANM paediatric dosage card.
Material and methods
Reflecting on EANM adult guidance on injected activities, and making reference to bed overlap and the concept of MBq.min bed\(^{-1}\) kg\(^{-1}\), we use published data on image quality from PET/MR systems to update the paediatric dosage card for PET/MR and extended axial field of view (≥ 25 cm) PET/CT systems. However, this communication does not cover the expansion of paediatric dosing for the half-body and total-body scanners that have recently come to market.
Results
In analogy to the existing EANM dosage card, new parameters for the EANM paediatric dosage card were developed (class B, baseline value: 10.7 MBq, minimum recommended activity 10 MBq). The recommended administered activities for the systems considered in this communication range from 11 MBq [\(^{18}\)F]FDG for a child with a weight of 3 kg to 149 MBq [\(^{18}\)F]FDG for a paediatric patient weight of 68 kg, assuming a scan of 3 min per bed position. The mean effective dose over all ages (1 year and older) is 2.85 mSv.
Conclusion
With this, recommendations for paediatric dosing are given for systems that have not been considered previously.
Die präklinische Forschung stellt den ersten wichtigen Meilenstein in der Klärung und Untersuchung klinisch-relevanter Erkrankungen dar. Darüber hinaus unterstützt die präklinische Forschung erheblich die Entwicklung von Therapien. Die Kleintier-Positronenemissionstomographie (µ-PET) spielt dabei eine wichtige Rolle, da sie in der Lage ist, funktionelle, physiologische und biochemische Prozesse in vivo darzustellen und zu quantifizieren. Trotz diverser etablierter PET-Datenauswertungs-Programme bleibt die Analyse von in vivo akquirierten Bilddaten aufgrund der Vielzahl an medizinischen Fragestellungen, der Komplexität der Krankheitsbilder, sowie der Etablierung neuer Radiotracer weiterhin eine große Herausforderung in der Medizin. Ziel dieser Doktorarbeit ist es daher, ein geeignetes, brauchbares Auswertungstool für eine einfache und effiziente Analyse von akquirierten µ-PET-Daten zu entwickeln und zu etablieren, welches das Spektrum bereits vorhandener Programme erweitert. Das entwickelte nuklearmedizinische Datenverarbeitungs-Analyseprogramm (engl. nuclear medicine data processing analysis tool, NU_DPA) wurde in Matlab implementiert und anhand dreier präklinischer Versuchs- bzw. Testreihen erprobt und etabliert. Bei den Datenreihen handelt es sich um µ-PET-Datensätze verschiedener Schlaganfall-Rattenhirnmodelle unter Verwendung folgender Radiotracer. Zum einen die im Gehirn homogen akkumulierende 2-[18F]Fluor-2-desoxy-glukose ([18F]FDG) zum anderen das spezifisch an P-Selektin anreichernde [68Ga]Fucoidan.
Das NU_DPA umfasst die automatische Selektion des Zielvolumens (volume-of-interest, VOI) aus dem vollständigen PET-Bild und die anschließende Ausrichtung des VOI mit Hilfe eines PET-Templates (gemittelter PET-Datensatz). Dieses PET Template wird aus den eigenen akquirierten PET-Daten erstellt. Durch das Einbinden eines geeigneten anatomischen MRT-Atlas‘ (anpassbar) können die ausgerichteten PET-Daten einzelnen, Atlas-spezifischen Teilregionen zugeordnet werden. Eine solche Subklassifikation des VOI erlaubt eine genauere Betrachtung und Auswertung der Radiotracer-Akkumulation.
Des Weiteren bietet NU_DPA die Möglichkeit einer semiquantitativen Auswertung der PET-Bilddaten anhand von drei unterschiedlichen Parametern, der normalisierten Aktivität, dem Standardized Uptake Value und der Uptake Ratio. Durch die Matlab-integrierten Statistik-Algorithmen ist zusätzlich eine Möglichkeit der statistischen Auswertung der zuvor berechneten Parameter gegeben. Das NU_DPA-Programm stellt somit ein semi-automatisiertes Datenauswertungs-Programm dar, das sowohl die Registrierung als auch die semiquantitative Auswertung von PET-Bilddaten innerhalb einer Versuchsreihe ermöglicht und bereits erfolgreich für die Radiotracer [18F]FDG und [68Ga]Fucoidan in Tiermodellen getestet wurde. Nach derzeitigem Kenntnisstand ist kein Datenauswertungs-Programm bekannt, das PET-Bilddaten unter Verwendung des hinzugefügten Atlas‘ semi-automatisiert analysieren kann und potenziell für homogene und Target-spezifisch akkumulierende Radiotracer geeignet ist.
Serotonin (5-hydroxytryptamine, 5-HT) as well as noradrenaline (NA) are key modulators of various fundamental brain functions including the control of appetite. While manipulations that alter brain serotoninergic signaling clearly affect body weight, studies implicating 5-HT transporters and NA transporters (5-HTT and NAT, respectively) as a main drug treatment target for human obesity have not been conclusive. The aim of this positron emission tomography (PET) study was to investigate how these central transporters are associated with changes of body weight after 6 months of dietary intervention or Roux-en-Y gastric bypass (RYGB) surgery in order to assess whether 5-HTT as well as NAT availability can predict weight loss and consequently treatment success. The study population consisted of two study cohorts using either the 5-HTT-selective radiotracer [\(^{11}\)C]DASB to measure 5-HTT availability or the NAT-selective radiotracer [\(^{11}\)C]MRB to assess NAT availability. Each group included non-obesity healthy participants, patients with severe obesity (body mass index, BMI, >35 kg/m\(^2\)) following a conservative dietary program (diet) and patients undergoing RYGB surgery within a 6-month follow-up. Overall, changes in BMI were not associated with changes of both 5-HTT and NAT availability, while 5-HTT availability in the dorsal raphe nucleus (DRN) prior to intervention was associated with substantial BMI reduction after RYGB surgery and inversely related with modest BMI reduction after diet. Taken together, the data of our study indicate that 5-HTT and NAT are involved in the pathomechanism of obesity and have the potential to serve as predictors of treatment outcomes.
Background
CXCR4-directed positron emission tomography/computed tomography (PET/CT) has been used as a diagnostic tool in patients with solid tumors. We aimed to determine a potential correlation between tumor burden and radiotracer accumulation in normal organs.
Methods
Ninety patients with histologically proven solid cancers underwent CXCR4-targeted [\(^{68}\)Ga]Ga-PentixaFor PET/CT. Volumes of interest (VOIs) were placed in normal organs (heart, liver, spleen, bone marrow, and kidneys) and tumor lesions. Mean standardized uptake values (SUV\(_{mean}\)) for normal organs were determined. For CXCR4-positive tumor burden, maximum SUV (SUV\(_{max}\)), tumor volume (TV), and fractional tumor activity (FTA, defined as SUV\(_{mean}\) x TV), were calculated. We used a Spearman's rank correlation coefficient (ρ) to derive correlative indices between normal organ uptake and tumor burden.
Results
Median SUV\(_{mean}\) in unaffected organs was 5.2 for the spleen (range, 2.44 – 10.55), 3.27 for the kidneys (range, 1.52 – 17.4), followed by bone marrow (1.76, range, 0.84 – 3.98), heart (1.66, range, 0.88 – 2.89), and liver (1.28, range, 0.73 – 2.45). No significant correlation between SUV\(_{max}\) in tumor lesions (ρ ≤ 0.189, P ≥ 0.07), TV (ρ ≥ -0.204, P ≥ 0.06) or FTA (ρ ≥ -0.142, P ≥ 0.18) with the investigated organs was found.
Conclusions
In patients with solid tumors imaged with [\(^{68}\)Ga]Ga-PentixaFor PET/CT, no relevant tumor sink effect was noted. This observation may be of relevance for therapies with radioactive and non-radioactive CXCR4-directed drugs, as with increasing tumor burden, the dose to normal organs may remain unchanged.
AimIn PET imaging, the different types of radiotracers and accumulations, as well as the diversity of disease patterns, make the analysis of molecular imaging data acquired in vivo challenging. Here, we evaluate and validate a semi-automated MRI template-based data analysis tool that allows preclinical PET images to be aligned to a self-created PET template. Based on the user-defined volume-of-interest (VOI), image data can then be evaluated using three different semi-quantitative parameters: normalized activity, standardized uptake value, and uptake ratio.
Materials and MethodsThe nuclear medicine Data Processing Analysis tool (NU_DPA) was implemented in Matlab. Testing and validation of the tool was performed using two types of radiotracers in different kinds of stroke-related brain diseases in rat models. The radiotracers used are 2-[\(^{18}\)F]fluoro-2-deoxyglucose ([\(^{18}\)F]FDG), a metabol\(^{68}\)Ga]Ga-Fucoidan, a target-selective radioligand specifically binding to p-selectin. After manual image import, the NU_DPA tool automatically creates an averaged PET template out of the acquired PET images, to which all PET images are then aligned onto. The added MRI template-based information, resized to the lower PET resolution, defines the VOI and also allows a precise subdivision of the VOI into individual sub-regions. The aligned PET images can then be evaluated semi-quantitatively for all regions defined in the MRI atlas. In addition, a statistical analysis and evaluation of the semi-quantitative parameters can then be performed in the NU_DPA tool.
ResultsUsing ischemic stroke data in Wistar rats as an example, the statistical analysis of the tool should be demonstrated. In this [\(^{18}\)F]FDG-PET experiment, three different experimental states were compared: healthy control state, ischemic stroke without electrical stimulation, ischemic stroke with electrical stimulation. Thereby, statistical data evaluation using the NU_DPA tool showed that the glucose metabolism in a photothrombotic lesion can be influenced by electrical stimulation.
ConclusionOur NU_DPA tool allows a very flexible data evaluation of small animal PET data in vivo including statistical data evaluation. Using the radiotracers [\(^{18}\)F]FDG and [\(^{68}\)Ga]Ga-Fucoidan, it was shown that the semi-automatic MRI-template based data analysis of the NU_DPA tool is potentially suitable for both metabolic radiotracers as well as target-selective radiotracers.
Background and Objectives
To analyze the impact of humidity and temperature on excimer laser ablation of polyethylene terephthalate (PET), polymethylmethacrylate (PMMA) and porcine corneal tissue, and an ablation model to compensate for the temperature and humidity changes on ablation efficiency.
Study Design/Materials and Methods
The study was conducted using an AMARIS 1050RS (Schwind eye‐tech‐solutions) placed inside a climate chamber at ACTS. Ablations were performed on PET, PMMA, and porcine cornea. The impact of a wide range of temperature (~18°C to ~30°C) and relative humidity (~25% to ~80%) on laser ablation outcomes was tested using nine climate test settings. For porcine eyes, change in defocus was calculated from the difference of post‐ablation to pre‐ablation average keratometry readings. Laser scanning deflectometry was performed to measure refractive change achieved in PMMA. Multiple linear regression was performed using the least square method with predictive factors: temperature, relative humidity, time stamp. Influence of climate settings was modeled for pulse energy, pulse fluence, ablation efficiency on PMMA and porcine cornea tissue.
Results
Temperature changes did not affect laser pulse energy, pulse fluence (PET), and ablation efficiency (on PMMA or porcine corneal tissue) significantly. Changes in relative humidity were critical and significantly affected laser pulse energy, high fluence and low fluence. The opposite trend was observed between the ablation performance on PMMA and porcine cornea.
Conclusions
The proposed well‐fitting multi‐linear model can be utilized for compensation of temperature and humidity changes on ablation efficiency. Based on this model, a working window for optimum operation has been found (temperature 18°C to 28°C and relative humidity 25% to 65%) for a maximum deviation of ±2.5% in ablation efficiency in PMMA and porcine corneal tissue.
Objective: We investigated cerebral opioid receptor binding potential in patients with fibromyalgia syndrome (FMS) using positron-emission-tomography (PET) and correlated our results with patients’ systemic interleukin-4 (IL-4) gene expression.
Methods: In this pilot study, seven FMS patients (1 man, 6 women) agreed to participate in experimental PET scans. All patients underwent neurological examination, were investigated with questionnaires for pain, depression, and FMS symptoms. Additionally, blood for IL-4 gene expression analysis was withdrawn at two time points with a median latency of 1.3 years. Patients were investigated in a PET scanner using the opioid receptor ligand F-18-fluoro-ethyl-diprenorphine ([18F]FEDPN) and results were compared with laboratory normative values.
Results: Neurological examination was normal in all FMS patients. Reduced opioid receptor binding was found in mid cingulate cortex compared to healthy controls (p < 0.005). Interestingly, three patients with high systemic IL-4 gene expression had increased opioid receptor binding in the fronto-basal cortex compared to those with low IL-4 gene expression (p < 0.005).
Conclusion: Our data give further evidence for a reduction in cortical opioid receptor availability in FMS patients as another potential central nervous system contributor to pain in FMS.
Background: Precise regional quantitative assessment of renal function is limited with conventional \(^{99m}\)Tc-labeled renal radiotracers. A recent study reported that the positron emission tomography (PET) radiotracer 2-deoxy-2-(\(^{18}\)F-fluorosorbitol (\(^{18}\)F-FDS) has ideal pharmacokinetics for functional renal imaging. Furthermore, (\(^{18}\)F-FDS is available via simple reduction from routinely used 2-deoxy-2-(\(^{18}\)F-fluoro-D-glucose ((\(^{18}\)F-FDG). We aimed to further investigate the potential of (\(^{18}\)F-FDS PET as a functional renal imaging agent using rat models of kidney diseases.
Methods: Two different rat models of renal impairment were investigated: Glycerol induced acute renal failure (ARF) by intramuscular administration of glycerol in hind legs and unilateral ureteral obstruction (UUO) by ligation of the left ureter. 24h after these treatments, dynamic 30 min 18F-FDS PET data were acquired using a dedicated small animal PET system. Urine 18F-FDS radioactivity 30 min after radiotracer injection was measured together with co-injected \(^{99m}\)Tc-diethylenetriaminepentaacetic acid (\(^{99m}\)Tc-DTPA) urine activity. Results: Dynamic PET imaging demonstrated rapid (\(^{18}\)F-FDS accumulation in the renal cortex and rapid radiotracer excretion via kidneys in control healthy rats. On the other hand, significantly delayed renal radiotracer uptake (continuous slow uptake) was observed in ARF rats and UUO-treated kidneys. Measured urine radiotracer concentrations of (\(^{18}\)F-FDS and \(^{99m}\)Tc-DTPA were well correlated (R=0.84, P<0.05).
Conclusions: (\(^{18}\)F-FDS PET demonstrated favorable kinetics for functional renal imaging in rat models of kidney diseases. Advantages of high spatiotemporal resolution of PET imaging and simple tracer production could potentially complement or replace conventional renal scintigraphy in select cases and significantly improve the diagnostic performance of renal functional imaging.