Refine
Has Fulltext
- yes (30)
Is part of the Bibliography
- yes (30)
Year of publication
Document Type
- Journal article (30)
Keywords
- fracture (4)
- surgery (4)
- Coronavirus (2)
- Injury Severity Score (2)
- Intensivkapazitäten (2)
- Pandemie (2)
- Polytrauma (2)
- arthritis (2)
- classification (2)
- fixation (2)
Institute
- Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II) (30)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (3)
- Klinik und Poliklinik für Anästhesiologie (ab 2004) (3)
- Institut für Anatomie und Zellbiologie (2)
- Lehrstuhl für Orthopädie (2)
- Abteilung für Funktionswerkstoffe der Medizin und der Zahnheilkunde (1)
- Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I) (1)
- Neurochirurgische Klinik und Poliklinik (1)
- Physiologisches Institut (1)
- Urologische Klinik und Poliklinik (1)
EU-Project number / Contract (GA) number
- 309962 (1)
Operative treatment of ruptured pubic symphysis by plating is often accompanied by complications. Trans-obturator cable fixation might be a more reliable technique; however, have not yet been tested for stabilization of ruptured pubic symphysis. This study compares symphyseal trans-obturator cable fixation versus plating through biomechanical testing and evaluates safety in a cadaver experiment. APC type II injuries were generated in synthetic pelvic models and subsequently separated into three different groups. The anterior pelvic ring was fixed using a four-hole steel plate in Group A, a stainless steel cable in Group B, and a titan band in Group C. Biomechanical testing was conducted by a single-leg-stance model using a material testing machine under physiological load levels. A cadaver study was carried out to analyze the trans-obturator surgical approach. Peak-to-peak displacement, total displacement, plastic deformation and stiffness revealed a tendency for higher stability for trans-obturator cable/band fixation but no statistical difference to plating was detected. The cadaver study revealed a safe zone for cable passage with sufficient distance to the obturator canal. Trans-obturator cable fixation has the potential to become an alternative for symphyseal fixation with less complications.
Background:
Pedicled perforator flaps have expanded reconstructive options in extremity reconstruction. Despite preoperative mapping, intraoperative findings may require microvascular tissue transfer when no adequate perforators can be found. The free peroneal artery perforator flap may serve as a reliable back-up plan in small defects.
Methods:
In 16 patients with small soft tissue defects on the upper and lower extremities, perforator-based propeller flaps were planned. The handheld Doppler device was used to localize potential perforators for a propeller flap in close proximity to the defect. Perforators of the proximal peroneal artery were also marked to allow conversion to microvascular tissue transfer.
Results:
In 6 cases, no adequate perforators were found intraoperatively. In 4 patients, the peroneal artery perforator flap was harvested and transferred. The pedicle length did not exceed 4 cm. No flap loss occurred.
Conclusions:
When no adequate perforator capable of nourishing a propeller flap can be found intraoperatively, the free peroneal artery flap is a good option to reconstruct small soft tissue defects in the distal extremities. The short vascular pedicle is less ideal in cases with a large zone of injury requiring a more distant site of anastomosis or when recipient vessels are located in deeper tissue planes.
Background
Barbed suture material offers the possibility of knotless flexor tendon repair, as suggested in an increasing number of biomechanical studies. There are currently two different absorbable barbed suture products available, V-Loc™ and Stratafix™, and both have not been compared to each other with regard to flexor tendon repair. The purpose of this study was to evaluate both suture materials for primary stability under static and cyclic loading in a biomechanical ex vivo model.
Methods
Forty fresh porcine flexor digitorum profundus tendons were randomized in two groups. A four-strand modified Kessler suture technique was used to repair the tendon either with a 3–0 V-Loc™ or 3–0 Stratafix™ without a knot. Parameters of interest were mode of failure, 2-mm gap formation force, displacement, stiffness and maximum load under static and cyclic testing.
Results
The maximum load was 42.3 ± 7.2 for the Stratafix™ group and 50.7 ± 8.8 N for the V-Loc™ group. Thus, the ultimate tensile strength was significantly higher for V-Loc™ (p < 0.05). The 2-mm gap occurred at 24.8 ± 2.04 N in the Stratafix™ group in comparison to 26.5 ± 2.12 N in the V-Loc™ group (n.s.). Displacement was 2.65 ± 0.56 mm in the V-Loc™ group and 2.71 ± 0.59 mm in the Stratafix™ group (n.s.). Stiffness was 4.24 ± 0.68 (N/mm) in the V-Loc™ group and 3.85 ± 0.55 (N/mm) the Stratafix™ group (n.s.). Those measured differences were not significant.
Conclusion
V-Loc™ demonstrates a higher maximum load in tendon reconstruction. The differences in 2-mm gap formation force, displacement and stiffness were not significant. Hereby, the V-Loc™ has an advantage when used as unidirectional barbed suture for knotless flexor tendon repair.
We report on a 14 months old toddler who sustained a traumatic hemipelvectomy by being crushed between a car and a stone wall. After stabilization in the resuscitation room he was treated operatively by laparotomy, osteosynthesis of the pelvic ring, reconstruction of the both external iliac vessels and the urethra and reposition of the testicles. After 66 days he was discharged into rehabilitation. Implants were removed after eight months. 20 months after the injury, the leg was plegic, initial radiological signs of femoral head necrosis showed up but the infant was able to walk with an orthesis and a walker.
Up to our knowledge, this is the youngest patient described in the literature with a survived traumatic hemipelvectomy and salvaged limb.
The calcaneal beak fracture is a rare avulsion fracture of the tuber calcanei characterized by a solid bony fragment at the Achilles tendon insertion. Treatment usually requires osteosynthesis. However, lack of biomechanical understanding of the ideal fixation technique persists. A beak fracture was simulated in synthetic bones and assigned to five different groups of fixation: A) 6.5-mm partial threaded cannulated screws, B) 4.0-mm partial threaded cannulated screws, C) 5.0-mm headless cannulated compression screws, D) 2.3-mm locking plate, and E) 2.8-mm locking plate. Different traction force levels were applied through an Achilles tendon surrogate in a material-testing machine on all stabilized synthetic bones. Outcome measures were peak-to-peak displacement, total displacement, plastic deformation, stiffness, visual-fracture-line displacement, and mode of implant failure. The 2.3- and 2.8-mm plating groups showed a high drop-out rate at 100 N tension force and failed under higher tension levels of 200 N. The fracture fixation using 4.0-mm partial threaded screws showed a significantly higher repair strength and was able to withhold cyclic loading up to 300 N. The lowest peak-to-peak displacement and the highest load-to-failure and stiffness were provided by fracture fixation using 6.5-mm partial threaded cannulated screws or 5.0-mm headless cannulated compression screws. As anticipated, large 6.5-mm screw diameters provide the best biomechanical fixation. Surprisingly, the 5.0-mm headless cannulated compression screws yield reliable stability despite the absent screw head and washer. When such large screws cannot be applied, 4.0-mm screws also allow reasonable fixation strength. Plate fixation should be implemented with precaution and in combination with a restrictive postoperative motion protocol. Finally, clinical cases about the surgical application and recovery are included.
Purpose
Displaced midshaft clavicular fractures can be treated conservatively as well as operatively by titan elastic nail (TEN) or plate fixation. This survey was performed to evaluate the clinical results of each treatment method and elaborate advantages or possible complications of each modality.
Methods
Between 2008 and 2013, 102 patients were prospectively included in our study—37 patients for conservative treatment with a rucksack bandage for 4 to 6 weeks, 41 patients for plate osteosynthesis, and 24 for intramedullary stabilization with TEN. Disabilities of the Arm, Shoulder and Hand (DASH), Constant Murley Score (CMS), and visual analog scale (VAS) for pain and function as well as time of invalidity were recorded over a 1-year period.
Results
The clinical data collected reveals that all three different therapies lead to good or excellent clinical results after 1 year. However, one can observe advantages of operative treatment in comparison to conservative therapy in some characteristics.
Conclusion
Our data shows that there are several indications where operative treatment has advantages compared to conservative treatment. In special fracture types (Robinson 2B1), TEN gives the best results. Plate fixation is extraordinarily sufficient in pain reduction within the first 5 weeks and indicated in more-part fractures (Robinson 2B2). Nevertheless, conservative treatment is always a good and promising way to treat clavicular fractures, so that individual indications and thorough patient informative talks are inevitable.
When aiming at cell‐based therapies in osteoarthritis (OA), proinflammatory conditions mediated by cytokines such as IL‐1β need to be considered. In recent studies, the phytoalexin resveratrol (RSV) has exhibited potent anti‐inflammatory properties. However, long‐term effects on 3D cartilaginous constructs under inflammatory conditions with regard to tissue quality, especially extracellular matrix (ECM) composition, have remained unexplored. Therefore, we employed long‐term model cultures for cell‐based therapies in an in vitro OA environment and evaluated effects of RSV. Pellet constructs made from expanded porcine articular chondrocytes were cultured with either IL‐1β (1–10 ng/ml) or RSV (50 μM) alone, or a cotreatment with both agents. Treatments were applied for 14 days, either directly after pellet formation or after a preculture period of 7 days. Culture with IL‐1β (10 ng/ml) decreased pellet size and DNA amount and severely compromised glycosaminoglycan (GAG) and collagen content. Cotreatment with RSV distinctly counteracted the proinflammatory catabolism and led to partial rescue of the ECM composition in both culture systems, with especially strong effects on GAG. Marked MMP13 expression was detected in IL‐1β‐treated pellets, but none upon RSV cotreatment. Expression of collagen type I was increased upon IL‐1β treatment and still observed when adding RSV, whereas collagen type X, indicating hypertrophy, was detected exclusively in pellets treated with RSV alone. In conclusion, RSV can counteract IL‐1β‐mediated degradation and distinctly improve cartilaginous ECM deposition in 3D long‐term inflammatory cultures. Nevertheless, potential hypertrophic effects should be taken into account when considering RSV as cotreatment for articular cartilage repair techniques.
Hintergrund
Die Fotodokumentation von offenen Frakturen, Wunden, Dekubitalulzera, Tumoren oder Infektionen ist ein wichtiger Bestandteil der digitalen Patientenakte. Bisher ist unklar, welchen Stellenwert diese Fotodokumentation bei der Abrechnungsprüfung durch den Medizinischen Dienst der Krankenkassen (MDK) hat.
Fragestellung
Kann eine Smartphone-basierte Fotodokumentation die Verteidigung von erlösrelevanten Diagnosen und Prozeduren sowie der Verweildauer verbessern?
Material und Methoden
Ausstattung der Mitarbeiter mit digitalen Endgeräten (Smartphone/Tablet) in den Bereichen Notaufnahme, Schockraum, OP, Sprechstunden sowie auf den Stationen. Retrospektive Auswertung der Abrechnungsprüfung im Jahr 2019 und Identifikation aller Fallbesprechungen, in denen die Fotodokumentation eine Erlösveränderung bewirkt hat.
Ergebnisse
Von insgesamt 372 Fallbesprechungen half die Fotodokumentation in 27 Fällen (7,2 %) zur Bestätigung eines Operationen- und Prozedurenschlüssels (OPS) (n = 5; 1,3 %), einer Hauptdiagnose (n = 10; 2,7 %), einer Nebendiagnose (n = 3; 0,8 %) oder der Krankenhausverweildauer (n = 9; 2,4 %). Pro oben genanntem Fall mit Fotodokumentation ergab sich eine durchschnittliche Erlössteigerung von 2119 €. Inklusive Aufwandpauschale für die Verhandlungen wurde somit ein Gesamtbetrag von 65.328 € verteidigt.
Diskussion
Der Einsatz einer Smartphone-basierten Fotodokumentation kann die Qualität der Dokumentation verbessern und Erlöseinbußen bei der Abrechnungsprüfung verhindern. Die Implementierung digitaler Endgeräte mit entsprechender Software ist ein wichtiger Teil des digitalen Strukturwandels in Kliniken.
Older patients sustaining tibial head depression fractures often cannot follow the post-operative rehabilitation protocols with partial weight-bearing of the affected limb, leading to osteosynthesis failure, cartilage step-off and arthritis development. Therefore, the aim of this study was to analyse the biomechanical performance of different types of osteosyntheses alone and in combination with bone cement simulating cyclically high loading conditions of tibial head depression fractures. Lateral tibial head depression fractures (AO: 41-B2.2; Schatzker type III) were created in synthetic bones and stabilized using three different osteosyntheses alone and in combination with a commonly used bone cement (chronOS™): 2 screws, 4 screws in the jail technique and a lateral angle-stable buttress plate. After fixation, the lateral tibial plateau was axially loaded in two, from each other independent testing series: In the first test protocol, 5000 cycles with 500 N and in the end load-to-failure tests were performed. In the second test protocol, the cyclic loading was increased to 1000 N. Parameters of interest were the displacement of the articular fracture fragment, the stiffness and the maximum load. The osteosyntheses revealed a higher stiffness in combination with bone cement compared to the same type of osteosynthesis alone (e.g., 500 N level: 2 screws 383 ± 43 N/mm vs. 2 screws + chronOs 520 ± 108 N/mm, increase by 36%, p < 0.01; 4 screws 368 ± 97 N/mm vs. 4 screws + chronOS 516 ± 109 N/mm, increase by 40%, p < 0.01; plate: 509 ± 73 N/mm vs. plate + chronOs 792 ± 150 N/mm, increase by 56%, p < 0.01). Bone cement reduced the displacement of the plate significantly (500 N level: plate: 8.9 ± 2.8 mm vs. plate + chronOs: 3.1 ± 1.4 mm, reduction by 65%, p < 0.01; 1000 N level: 16.9 ± 3.6 mm vs 5.6 ± 1.3 mm, reduction by 67%, p < 0.01). Thus, the highest stiffness and lowest displacement values were found when using the plate with bone cement in both loading conditions (500 N level: 2 screws + chronOs 3.7 ± 1.3 mm, 4 screws + chronOs 6.2 ± 2.4 mm; 1000 N level: 2 screws + chronOs 6.5 ± 1.2 mm, 4 screws + chronOs 5.7 ± 0.8 mm). From a biomechanical perspective, plate osteosynthesis of tibial head depression fractures should always be combined with bone cement, provides higher stability than 2-screw and 4-screw fixation and is a valid treatment option in cases where extraordinary stability is required.
Background
Postoperative pulmonary complications (PPCs) increase morbidity and mortality of surgical patients, duration of hospital stay and costs. Postoperative atelectasis of dorsal lung regions as a common PPC has been described before, but its clinical relevance is insufficiently examined. Pulmonary electrical impedance tomography (EIT) enables the bedside visualization of regional ventilation in real-time within a transversal section of the lung. Dorsal atelectasis or effusions might cause a ventral redistribution of ventilation. We hypothesized the existence of ventral redistribution in spontaneously breathing patients during their recovery from abdominal and peripheral surgery and that vital capacity is reduced if regional ventilation shifts to ventral lung regions.
Methods
This prospective observational study included 69 adult patients undergoing elective surgery with an expected intermediate or high risk for PPCs. Patients undergoing abdominal and peripheral surgery were recruited to obtain groups of equal size. Patients received general anesthesia with and without additional regional anesthesia. On the preoperative, the first and the third postoperative day, EIT was performed at rest and during spirometry (forced breathing). The center of ventilation in dorso-ventral direction (COVy) was calculated.
Results
Both groups received intraoperative low tidal volume ventilation. Postoperative ventral redistribution of ventilation (forced breathing COVy; preoperative: 16.5 (16.0–17.3); first day: 17.8 (16.9–18.2), p < 0.004; third day: 17.4 (16.2–18.2), p = 0.020) and decreased forced vital capacity in percentage of predicted values (FVC%predicted) (median: 93, 58, 64%, respectively) persisted after abdominal surgery. In addition, dorsal to ventral shift was associated with a decrease of the FVC%predicted on the third postoperative day (r = − 0.66; p < 0.001). A redistribution of pulmonary ventilation was not observed after peripheral surgery. FVC%predicted was only decreased on the first postoperative day (median FVC%predicted on the preoperative, first and third day: 85, 81 and 88%, respectively). In ten patients occurred pulmonary complications after abdominal surgery also in two patients after peripheral surgery.
Conclusions
After abdominal surgery ventral redistribution of ventilation persisted up to the third postoperative day and was associated with decreased vital capacity. The peripheral surgery group showed only minor changes in vital capacity, suggesting a role of the location of surgery for postoperative redistribution of pulmonary ventilation.
Background
To cover soft tissue defects, the perforator-based propeller flap offers the option to rotate healthy tissue into complex wounds. By rotating the flap, the perforator is torqued. As a result, perfusion changes are possible.
Methods
A retrospective data analysis of patients was done, who received a propeller flap to cover soft tissue defects of the lower extremity as well as a peri- and postoperative perfusion monitoring with a laser-Doppler-spectrophotometry system. Additionally, patient-specific data were collected.
Results
Seven patients were identified. Four patients experienced early complications, two epidermolysis of the distal flap areas, three wound healing disorders, and one partial flap necrosis. Intraoperative perfusion monitoring showed a decline of blood flow after incision of the flap, especially at distal flap site. In case of complications, there were prolonged blood flow declines up to the first postoperative day.
Conclusion
Torqueing the perforator by rotating the flap can cause an impairment in inflow and outflow. If the impairment is prolonged, perfusion-associated complications are possible. The identification of a viable perforator is particularly important. In addition, a conservative postoperative mobilization is necessary to compensate for the impaired and adapting outflow.
Background: The soft tissue of the central pretibial area is difficult to reconstruct often requiring free tissue transfer. Especially medi- cally compromised patients are not ideal candidates for free tissue transfer and may benefit from expeditiously harvested local flaps with limited donor site morbidity. As muscle flaps are rare, pedi- cled flaps based on lateral perforators represent an alternative as the arc of rotation can often be limited to 90 °.
Material and Methods: A retrospective analysis of patient data was conducted to identify patients over the age of 60 years with comor- bidities that underwent pretibial soft tissue reconstruction with a single-pedicle perforator flap. Patient demographics, size and cause of the defect, flap dimension, arc of rotation and complications were recorded.
Results: Five patients with an average age of 71.4 years were in- cluded. The arc of rotation was 69 °, all flaps healed. There were two recurrences of osteomyelitis.
Conclusion: Lateral perforators originating from the anterior tib- ial artery or peroneal artery are adequate source vessels for single pedicled perforator flaps even in medically compromised patients. A perforator located proximal to the defect allows limiting the arcof rotation to less than 90 °, which increases the safety of the flap. Patients benefit from a simple procedure without a microvascular anastomosis and a donor site confined to one extremity
Multiple-level amputations of the upper extremity represent a surgical challenge generally only attempted in young patients. This case demonstrates a successful replantation in an elderly woman. The postoperative course was complicated by disseminated intravascular coagulopathy most likely due to inadequate resuscitation. Hand trauma is often underestimated in its general severity. Upper extremity amputations need to be handled similar to polytraumatized patients.
Background:
Propeller flaps require torsion of the vascular pedicle of up to 180 degrees. Contrary to free flaps, where the relevance of an intact vascular pedicle has been documented, little is known regarding twisted pedicles of propeller flaps. As secondary surgeries requiring undermining of the flap are common in the extremities, knowledge regarding the necessity to protect the pedicle is relevant. The aim of this study was a long-term evaluation of the patency of vascular pedicle of propeller flaps.
Methods:
In a retrospective clinical study, 22 patients who underwent soft-tissue reconstruction with a propeller flap were evaluated after 43 months. A Doppler probe was used to locate and evaluate the patency of the vascular pedicle of the flap.
Results:
The flaps were used in the lower extremity in 19 cases, on the trunk in 3 cases. All flaps had healed. In all patients, an intact vascular pedicle could be found. Flap size, source vessel, or infection could therefore not be linked to an increased risk of pedicle loss.
Conclusions:
The vascular pedicle of propeller flaps remains patent in the long term. This allows reelevation and undermining of the flap. We therefore recommend protecting the pedicle in all secondary cases to prevent later flap loss.
Background
Morphology and glenoid involvement determine the necessity of surgical management in scapula fractures. While being present in only a small share of patients with shoulder trauma, numerous classification systems have been in use over the years for categorization of scapula fractures. The purpose of this study was to evaluate the established AO/OTA classification in comparison to the classification system of Euler and Rüedi (ER) with regard to interobserver reliability and confidence in clinical practice.
Methods
Based on CT imaging, 149 patients with scapula fractures were retrospectively categorized by two trauma surgeons and two radiologists using the classification systems of ER and AO/OTA. To measure the interrater reliability, Fleiss kappa (κ) was calculated independently for both fracture classifications. Rater confidence was stated subjectively on a five-point scale and compared with Wilcoxon signed rank tests. Additionally, we computed the intraclass correlation coefficient (ICC) based on absolute agreement in a two-way random effects model to assess the diagnostic confidence agreement between observers.
Results
In scapula fractures involving the glenoid fossa, interrater reliability was substantial (κ = 0.722; 95% confidence interval [CI] 0.676–0.769) for the AO/OTA classification in contrast to moderate agreement (κ = 0.579; 95% CI 0.525–0.634) for the ER classification system. Diagnostic confidence for intra-articular fracture patterns was superior using the AO/OTA classification compared to ER (p < 0.001) with higher confidence agreement (ICC: 0.882 versus 0.831). For extra-articular fractures, ER (κ = 0.817; 95% CI 0.771–0.863) provided better interrater reliability compared to AO/OTA (κ = 0.734; 95% CI 0.692–0.776) with higher diagnostic confidence (p < 0.001) and superior agreement between confidence ratings (ICC: 0.881 versus 0.912).
Conclusions
The AO/OTA classification is most suitable to categorize intra-articular scapula fractures with glenoid involvement, whereas the classification system of Euler and Rüedi appears to be superior in extra-articular injury patterns with fractures involving only the scapula body, spine, acromion and coracoid process.
Traumatic brain injury (TBI) is the leading cause of death and disability in polytrauma and is often accompanied by concomitant injuries. We conducted a retrospective matched-pair analysis of data from a 10-year period from the multicenter database TraumaRegister DGU\(^®\) to analyze the impact of a concomitant femoral fracture on the outcome of TBI patients. A total of 4508 patients with moderate to critical TBI were included and matched by severity of TBI, American Society of Anesthesiologists (ASA) risk classification, initial Glasgow Coma Scale (GCS), age, and sex. Patients who suffered combined TBI and femoral fracture showed increased mortality and worse outcome at the time of discharge, a higher chance of multi-organ failure, and a rate of neurosurgical intervention. Especially those with moderate TBI showed enhanced in-hospital mortality when presenting with a concomitant femoral fracture (p = 0.037). The choice of fracture treatment (damage control orthopedics vs. early total care) did not impact mortality. In summary, patients with combined TBI and femoral fracture have higher mortality, more in-hospital complications, an increased need for neurosurgical intervention, and inferior outcome compared to patients with TBI solely. More investigations are needed to decipher the pathophysiological consequences of a long-bone fracture on the outcome after TBI.
Hintergrund
Intensiv- und Beatmungskapazitäten sind für die Behandlung COVID-19-erkrankter Patienten essenziell. Unabhängig davon beanspruchen auch schwer verletzte Patienten häufig Intensiv- und Beatmungskapazitäten. Daraus ergibt sich folgende Fragestellung: Führt eine Ausgangsbeschränkung zu einer Reduktion schwer verletzter Patienten, und kann hierdurch mit frei werdenden Intensivkapazitäten gerechnet werden?
Material und Methoden
Es erfolgte eine retrospektive Auswertung schwer verletzter Patienten mit einem Injury Severity Score (ISS) ≥16 zwischen dem 17.03.2020 und 30.04.2020 (landesweiter Shutdown) an einem überregionalen Traumazentrum. Erfasst wurden der Unfallmechanismus, ISS, Versicherungsträger (BG vs. GKV/PKV), ob es sich um einen dokumentierten Suizidversuch handelte, und ob eine operative Intervention innerhalb der ersten 24 h erforderlich war. Als Kontrollgruppe wurden die Daten des gleichen Zeitraums der Jahre 2018 und 2019 ausgewertet.
Ergebnisse
Es konnte keine wesentliche Veränderung bezüglich der Anzahl an schwer verletzten Patienten festgestellt werden (2018 n = 30, 2019 n = 23, 2020 n = 27). Es zeigten sich insgesamt keine deutlichen Veränderungen der absoluten Zahlen bezüglich der Intensivpflichtigkeit in den ersten 24 h und der Beatmungspflichtigkeit beim Verlassen des Schockraums. Die Anzahl an Patienten, die eine Operation innerhalb der ersten 24 h nach Eintreffen im Schockraum benötigten, war 2020 sogar leicht erhöht, jedoch nicht statistisch signifikant. Der durchschnittliche ISS blieb konstant. Bezüglich der Unfallursache zeigte sich 2020 kein Motorradfahrer, der einen nicht berufsgenossenschaftlich versicherten Unfall erlitt (2018 n = 5, 2019 n = 4, 2020 n = 0). Es wurde 2020 ein erhöhter Anteil an Arbeitsunfällen mit einem ISS ≥16 festgestellt (2018: 10 %, 2019: 26,1 %, 2020: 44,4 %).
Diskussion
Eine Ausgangsbeschränkung führte zu keiner Reduktion verletzter- und intensivpflichtiger Patienten am untersuchten Zentrum. Auch unter einer landesweiten Ausgangsbeschränkung muss für dieses Patientenkollektiv eine ausreichende Menge an Intensiv- und OP-Kapazitäten vorgehalten werden. Die Bestätigung dieser Ergebnisse durch Auswertung nationaler Register steht noch aus.
Hintergrund
Intensiv- und Beatmungskapazitäten sind für die Behandlung COVID-19-erkrankter Patienten essenziell. Unabhängig davon beanspruchen auch schwer verletzte Patienten häufig Intensiv- und Beatmungskapazitäten. Daraus ergibt sich folgende Fragestellung: Führt eine Ausgangsbeschränkung zu einer Reduktion schwer verletzter Patienten, und kann hierdurch mit frei werdenden Intensivkapazitäten gerechnet werden?
Material und Methoden
Es erfolgte eine retrospektive Auswertung schwer verletzter Patienten mit einem Injury Severity Score (ISS) ≥16 zwischen dem 17.03.2020 und 30.04.2020 (landesweiter Shutdown) an einem überregionalen Traumazentrum. Erfasst wurden der Unfallmechanismus, ISS, Versicherungsträger (BG vs. GKV/PKV), ob es sich um einen dokumentierten Suizidversuch handelte, und ob eine operative Intervention innerhalb der ersten 24 h erforderlich war. Als Kontrollgruppe wurden die Daten des gleichen Zeitraums der Jahre 2018 und 2019 ausgewertet.
Ergebnisse
Es konnte keine wesentliche Veränderung bezüglich der Anzahl an schwer verletzten Patienten festgestellt werden (2018 n = 30, 2019 n = 23, 2020 n = 27). Es zeigten sich insgesamt keine deutlichen Veränderungen der absoluten Zahlen bezüglich der Intensivpflichtigkeit in den ersten 24 h und der Beatmungspflichtigkeit beim Verlassen des Schockraums. Die Anzahl an Patienten, die eine Operation innerhalb der ersten 24 h nach Eintreffen im Schockraum benötigten, war 2020 sogar leicht erhöht, jedoch nicht statistisch signifikant. Der durchschnittliche ISS blieb konstant. Bezüglich der Unfallursache zeigte sich 2020 kein Motorradfahrer, der einen nicht berufsgenossenschaftlich versicherten Unfall erlitt (2018 n = 5, 2019 n = 4, 2020 n = 0). Es wurde 2020 ein erhöhter Anteil an Arbeitsunfällen mit einem ISS ≥16 festgestellt (2018: 10 %, 2019: 26,1 %, 2020: 44,4 %).
Diskussion
Eine Ausgangsbeschränkung führte zu keiner Reduktion verletzter- und intensivpflichtiger Patienten am untersuchten Zentrum. Auch unter einer landesweiten Ausgangsbeschränkung muss für dieses Patientenkollektiv eine ausreichende Menge an Intensiv- und OP-Kapazitäten vorgehalten werden. Die Bestätigung dieser Ergebnisse durch Auswertung nationaler Register steht noch aus.
Background:
Although indocyanine-green fluorescence angiography (ICG-FA) has been established as a useful tool to assess perfusion in free tissue transfer, only few studies have applied this modality to pedicled perforator flaps. As both volume and reach of pedicled perforator flaps are limited and tip necrosis often equals complete flap failure, ICG-FA may help to detect hypoperfusion in pedicled flaps.
Methods:
In 5 patients, soft tissue reconstruction was achieved with pedicled perforator flaps. ICG-FA was utilized intraoperatively to visualize flap perfusion.
Results:
Three pedicled anterolateral thigh flap flaps and 2 propeller flaps were transferred. ICG-FA detected hypoperfusion in 2 flaps. No flap loss occurred; in 2 cases, prolonged wound healing was encountered.
Conclusions:
ICG-FA confirmed clinical findings and reliably detected tissue areas with hypoperfusion. A clear cut-off point between nonvital tissue and such that stabilized in the following clinical course could not be found. ICG-FA is a promising technology which could also be used in pedicled perforator flaps.
Hintergrund
Die Symphysensprengung mit entsprechender Diastase kann durch eine Symphysenplatte stabilisiert werden.
Fragestellung
Welche Beckenverletzungen werden mit einer Symphysenplatte stabilisiert und wie ist das Outcome?
Material und Methoden
Retrospektive Auswertung von 64 Patienten über einen Untersuchungszeitraum von 24 Monaten.
Ergebnisse
Es waren 56 Patienten männlich, 8 weiblich und das mittlere Alter betrug 44 Jahre (SD ± 17). Unfälle im Straßenverkehr waren der führende Grund für die Beckenverletzung. Die Verteilung nach AO-Klassifikation zeigte sich wie folgt: 14-mal B1-, 10-mal B2-, 5‑mal B3-, 23-mal C1-, 9‑mal C2- und 3‑mal C3-Verletzungen. Die Verteilung nach Young und Burgess ergab: 9‑mal APC-I-, 18-mal APC-II-, 13-mal APC-III-, 9‑mal LC-I-, 3‑mal LC-II-, 2‑mal LC-III- und 10-mal VS-Verletzungen. Der mittlere Injury Severity Score (ISS) betrug 32 und die mittlere stationäre Verweildauer 29 Tage (pos. Korrelation p ≤ 0,001). Im Verlauf war eine radiologische Implantatlockerung bei 52 Patienten nachweisbar. Therapierelevante Komplikationen gab es in 14 Fällen. Hierbei war das Implantatversagen (n = 8) der Hauptgrund für eine operative Revision.
Diskussion
Obwohl die radiologische Implantatlockerung häufig beobachtet wird, ist sie nur selten Grund für einen Revisionseingriff. Kommt es hingegen zum vollständigen Implantatversagen, tritt dies meist innerhalb der ersten postoperativen Wochen auf und ist revisionsbedürftig. Eine frühzeitige Abklärung durch Röntgenbildgebung sollte bei Verdacht erfolgen.