• Contact
    • Imprint
    • Sitemap
      • Deutsch

UNIWUE UBWUE Universitätsbibliothek

  • Home
  • Search
  • Browse
  • Publish
  • Help
Schließen

Refine

Document Type

  • Journal article (1) (remove)

Keywords

  • DaTscan (1) (remove)

Author

  • Buck, Andreas K. (1)
  • Du, Yong (1)
  • Higuchi, Takahiro (1)
  • Javadi, Mehrbod S. (1)
  • Lapa, Constantin (1)
  • Leal, Jeffrey P. (1)
  • Marcus, Charles (1)
  • Rowe, Steven P. (1)
  • Sheikhbahaei, Sara (1)
  • Solnes, Lilja B. (1)
+ more

1 search hit

  • 1 to 1
  • BibTeX
  • CSV
  • RIS
  • XML
  • 10
  • 20
  • 50
  • 100
Visual and Semiquantitative Accuracy in Clinical Baseline 123I-Ioflupane SPECT/CT Imaging (2018)
Werner, Rudolf A. ; Marcus, Charles ; Sheikhbahaei, Sara ; Solnes, Lilja B. ; Leal, Jeffrey P. ; Du, Yong ; Rowe, Steven P. ; Higuchi, Takahiro ; Buck, Andreas K. ; Lapa, Constantin ; Javadi, Mehrbod S.
PURPOSE: We aimed to (a) elucidate the concordance of visual assessment of an initial I-ioflupane scan by a human interpreter with comparison to results using a fully automatic semiquantitative method and (b) to assess the accuracy compared to follow-up (f/u) diagnosis established by movement disorder specialists. METHODS: An initial I-ioflupane scan was performed in 382 patients with clinically uncertain Parkinsonian syndrome. An experienced reader performed a visual evaluation of all scans independently. The findings of the visual read were compared with semiquantitative evaluation. In addition, available f/u clinical diagnosis (serving as a reference standard) was compared with results of the human read and the software. RESULTS: When comparing the semiquantitative method with the visual assessment, discordance could be found in 25 (6.5%) of 382 of the cases for the experienced reader (ĸ = 0.868). The human observer indicated region of interest misalignment as the main reason for discordance. With neurology f/u serving as reference, the results of the reader revealed a slightly higher accuracy rate (87.7%, ĸ = 0.75) compared to semiquantification (86.2%, ĸ = 0.719, P < 0.001, respectively). No significant difference in the diagnostic performance of the visual read versus software-based assessment was found. CONCLUSIONS: In comparison with a fully automatic semiquantitative method in I-ioflupane interpretation, human assessment obtained an almost perfect agreement rate. However, compared to clinical established diagnosis serving as a reference, visual read seemed to be slightly more accurate as a solely software-based quantitative assessment.
  • 1 to 1

DINI-Zertifikat     OPUS4 Logo