Refine
Has Fulltext
- yes (28)
Is part of the Bibliography
- yes (28)
Year of publication
Document Type
- Journal article (28)
Keywords
- Coronavirus (2)
- Injury Severity Score (2)
- Intensivkapazitäten (2)
- MRI (2)
- Medizin (2)
- Pandemie (2)
- Polytrauma (2)
- accelerometer (2)
- classification (2)
- gait (2)
Institute
- Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II) (22)
- Lehrstuhl für Orthopädie (7)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (4)
- Institut für Anatomie und Zellbiologie (2)
- Klinik und Poliklinik für Anästhesiologie (ab 2004) (2)
- Deutsches Zentrum für Herzinsuffizienz (DZHI) (1)
- Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I) (1)
- Medizinische Klinik und Poliklinik I (1)
- Neurochirurgische Klinik und Poliklinik (1)
- Physiologisches Institut (1)
Operative treatment of ruptured pubic symphysis by plating is often accompanied by complications. Trans-obturator cable fixation might be a more reliable technique; however, have not yet been tested for stabilization of ruptured pubic symphysis. This study compares symphyseal trans-obturator cable fixation versus plating through biomechanical testing and evaluates safety in a cadaver experiment. APC type II injuries were generated in synthetic pelvic models and subsequently separated into three different groups. The anterior pelvic ring was fixed using a four-hole steel plate in Group A, a stainless steel cable in Group B, and a titan band in Group C. Biomechanical testing was conducted by a single-leg-stance model using a material testing machine under physiological load levels. A cadaver study was carried out to analyze the trans-obturator surgical approach. Peak-to-peak displacement, total displacement, plastic deformation and stiffness revealed a tendency for higher stability for trans-obturator cable/band fixation but no statistical difference to plating was detected. The cadaver study revealed a safe zone for cable passage with sufficient distance to the obturator canal. Trans-obturator cable fixation has the potential to become an alternative for symphyseal fixation with less complications.
Background
Locked dislocations of the glenohumeral joint are disabling and often painful conditions and the treatment is challenging. This study evaluates the functional outcome and the different prosthetic treatment options for chronic locked dislocations of the glenohumeral joint and a subclassification is proposed.
Methods
In this single-center retrospective case series, all patients with a chronic locked dislocation treated surgically during a four-year period were analyzed. Constant score (CS), Quick Disabilities of Shoulder and Hand Score (DASH), patient satisfaction (subjective shoulder value (SSV)), revision rate and glenoid notching were analyzed.
Results
26 patients presented a chronic locked dislocation of the glenohumeral joint. 16 patients (62%) with a mean age of 75 [61-83] years were available for follow-up at 24 ± 18 months. CS improved significantly from 10 ± 6 points to 58 ± 21 points (p < 0.0001). At the final follow-up, the mean DASH was 27 ± 23 and the mean SSV was 58 ± 23 points. The complication rate was 19% and the revision rate was 6%; implant survival was 94%. Scapular notching occurred in 2 (13%) cases (all grade 1).
Conclusion
With good preoperative planning and by using the adequate surgical technique, good clinical short-term results with a low revision rate can be achieved. The authors suggest extending the Boileau classification for fracture sequelae type 2 and recommend using a modified classification to facilitate the choice of treatment as the suggested classification system includes locked posterior and anterior dislocations with and without glenoid bone loss.
Introduction
Reverse shoulder arthroplasty (RSA) leads to medialization and distalization of the centre of rotation of the shoulder joint resulting in lengthening of the deltoid muscle. Shear wave ultrasound elastography (SWE) is a reliable method for quantifying tissue stiffness. The purpose of this study was to analyse if deltoid muscle tension after RSA correlates with the patients' pain level. We hypothesized that higher deltoid muscle tension would be associated with increased pain.
Material and methods
Eighteen patients treated with RSA were included. Constant score (CS) and pain level on the visual analogue scale (VAS) were analysed and SWE was performed on both shoulders. All three regions of the deltoid muscle were examined in resting position and under standardized isometric loading.
Results
Average patient age was 76 (range 64-84) years and average follow-up was 15 months (range 4-48). The average CS was 66 points (range 35-89) and the average pain level on the VAS was 1.8 (range 0.5-4.7). SWE revealed statistically significant higher muscle tension in the anterior and middle deltoid muscle region in patients after RSA compared to the contralateral non-operated side. There was a statistically significant correlation between pain level and anterior deltoid muscle tension.
Conclusion
SWE revealed increased tension in the anterior and middle portion of the deltoid muscle after RSA in a clinical setting. Increased tension of the anterior deltoid muscle portion significantly correlated with an increased pain level. SWE is a powerful, cost-effective, quick, dynamic, non-invasive, and radiation-free imaging technique to evaluate tissue elasticity in the shoulder with a wide range of applications.
Background
Traumatic separation of the pubic symphysis can destabilize the pelvis and require surgical fixation to reduce symphyseal gapping. The traditional approach involves open reduction and the implantation of a steel symphyseal plate (SP) on the pubic bone to hold the reposition. Despite its widespread use, SP-fixation is often associated with implant failure caused by screw loosening or breakage.
Methods
To address the need for a more reliable surgical intervention, we developed and tested two titanium cable-clamp implants. The cable served as tensioning device while the clamp secured the cable to the bone. The first implant design included a steel cable anterior to the pubic symphysis to simplify its placement outside the pelvis, and the second design included a cable encircling the pubic symphysis to stabilize the anterior pelvic ring. Using highly reproducible synthetic bone models and a limited number of cadaver specimens, we performed a comprehensive biomechanical study of implant stability and evaluated surgical feasibility.
Results
We were able to demonstrate that the cable-clamp implants provide stability equivalent to that of a traditional SP-fixation but without the same risks of implant failure. We also provide detailed ex vivo evaluations of the safety and feasibility of a trans-obturator surgical approach required for those kind of fixation.
Conclusion
We propose that the developed cable-clamp fixation devices may be of clinical value in treating pubic symphysis separation.
Background
Avascular necrosis of the humeral head after proximal humeral fracture i.e. type 1 fracture sequelae (FS) according to the Boileau classification is a rare, often painful condition and treatment still remains a challenge. This study evaluates the treatment of FS type 1 with anatomic and reverse shoulder arthroplasty and a new subclassification is proposed.
Methods
This single-center, retrospective, comparative study, included all consecutive patients with a proximal humeral FS type 1 treated surgically in a four-year period. All patients were classified according to the proposed 3 different subtypes.
Constant score (CS), Quick DASH score, subjective shoulder value (SSV) as well as revision and complication rate were analyzed. In the preoperative radiographs the acromio-humeral interval (AHI) and greater tuberosity resorption were examined.
Results
Of 27 with a FS type 1, 17 patients (63%) with a mean age of 64 ± 11 years were available for follow-up at 24 ± 10 months. 7 patients were treated with anatomic and 10 with reverse shoulder arthroplasty. CS improved significantly from 16 ± 7 points to 61 ± 19 points (p < 0.0001). At final follow-up the mean Quick DASH Score was 21 ± 21 and the mean SSV was 73 ± 21 points. The mean preoperative AHI was 9 ± 3 mm, however, 8 cases presented an AHI < 7 mm. 4 cases had complete greater tuberosity resorption.
The complication and revision rate was 19%; implant survival was 88%.
Conclusion
By using the adequate surgical technique good clinical short-term results with a relatively low complication rate can be achieved in FS type 1. The Boileau classification should be extended for fracture sequelae type 1 and the general recommendation for treatment with hemiarthroplasty or total shoulder arthroplasty has to be relativized. Special attention should be paid to a decreased AHI and/or resorption of the greater tuberosity as indirect signs for dysfunction of the rotator cuff. To facilitate the choice of the adequate prosthetic treatment method the suggested subclassification system should be applied.
Background:
Flap reconstruction of the distal lower extremity is challenging. Especially, the concept of perforator surgery has increased available surgical options. Although results are generally judged in terms of objective facts, patients-perceived quality of life has largely remained unexamined. The aim of the study was to compare quality of life after lower extremity reconstruction with pedicled and free flaps.
Methods:
Patients were evaluated retrospectively after reconstruction of defects of the distal lower extremity either with distally based adipofascial sural flap (pedicled reverse sural flap) or an anterior lateral thigh (ALT) flap. A specific questionnaire was developed to measure the patient’s quality of life, based on short form health survey-12, Dresden Body Image Score-35, Patient Health Questionnaire-4, and XSMFA questionnaires with additional specific questions. Furthermore, results, secondary surgeries, and complications were analyzed.
Results:
Thirty-seven patients with reconstruction of lower limb defects treated with a pedicled reverse sural flap and 34 patients treated with an ALT flap were included in the study. There was no statistical significant difference in the overall satisfaction with the procedure in the long-term follow-up between both groups, but patients with ALT showed a higher satisfaction with the treatment in the initial postoperative period. Both groups demonstrated approximately similar results in the long term for self-acceptance and vitality.
Conclusions:
Although anatomic situation may dictate flap choice coverage with free flaps, a less-complicated flap is by no means regarded as an inferior treatment option in patient’s estimation. Despite the intuitive speculation that patients with more advanced reconstruction methods should have better function and subsequently higher quality of life, this assumption was clearly not supported by data in this study.
Background:
Fatty Degeneration (FD) of the rotator cuff muscles influences functional and anatomical outcome after rotator cuff repair. The MRI based estimation of fatty degeneration is the gold standard. There is some evidence that Ultrasound elastography (EUS) can detect local differences of tissue stiffness in muscles and tendons. Shear-wave elastography (SWE) was evaluated to determine the extent to which shear wave velocity was associated with measures of fatty degeneration. MRI-spectroscopic fat measurement was used as a reference to quantify the amount of fat in the muscle belly.
Methods:
Forty-two patients underwent SWE of the supraspinatus muscles at its thickest diameter. After ultrasound evaluation an MRI-spectroscopic fat measurement of the supraspinatus muscle was performed using the SPLASH-technique. A gel filled capsule was used to locate the measured area in the MRI. The values of shear wave velocity (SWV) measured with SWE and spectroscopic fat measurement were correlated statistically using Pearson’s correlation test.
Results:
Correlation of the fat amount measured with MRI-spectroscopy and the SWV measured with SWE was ρ =0.82. Spectroscopic measured fat ratio of the supraspinatus muscle ranged from 0% to 77.41% and SWV from 1.59 m/s to 5.32 m/s. In 4 patients no sufficient SWE could be performed, these individuals showed a larger diameter of the overlying soft tissue. SWV measured with SWE showed a good correlation with MRI spectroscopic fat amount of the supraspinatus muscle.
Conclusion:
These preliminary data suggest that SWE may be a sufficient tool in detecting and estimating the amount of fatty degeneration in the supraspinatus muscle in real time. Large overlying soft tissue may be a limitation in performing sufficient EUS.
Background:
Reverse oblique distal radio-ulnar joint (DRUJ) configuration is assumed to show inferior postoperative results in ulnar-shortening osteotomy due to osteoarthritis, as the joint force pressure in the DRUJ may be increased. An evaluation and comparison of the postoperative functional results with regard to clinical and radiographic signs of arthritis among different DRUJ configurations was carried out retrospectively.
Methods:
Sixty-two patients after ulnar shortening osteotomy were included. The minimum follow-up was 5 years. Preoperative x-rays were assessed for the DRUJ configuration according to the Tolat classification, whereas postoperative radiographs were evaluated with regard to signs of osteoarthritis using the Kallgren-Lawrence-Score. Functional results were evaluated using the disabilities of the arm, shoulder and hand (DASH) and Mayo Wrist Score and measuring range of motion and grip strength.
Results:
Significantly better functional results were found in patients with parallel configuration of the DRUJ (Tolat type 1 configuration) with regard to DASH score, grip strength, and supination compared with nonparallel configurations. In the Tolat type 1, configurated DRUJ mean DASH score was 9 compared with 18 in the Tolat type 2 and 3 groups. Apart from supination, no differences were observed in range of motion among groups.
Conclusion:
Although long-term postoperative range of motion failed to display statistically significant differences between DRUJ configurations except for supination, better results regarding grip strength and DASH scores were seen in a parallel-aligned DRUJ configuration. Although onset of osteoarthritis does not seem to become apparent within the observation period, nonparallel aligned configuration predisposes to inferior results.
Background:
Propeller flaps require torsion of the vascular pedicle of up to 180 degrees. Contrary to free flaps, where the relevance of an intact vascular pedicle has been documented, little is known regarding twisted pedicles of propeller flaps. As secondary surgeries requiring undermining of the flap are common in the extremities, knowledge regarding the necessity to protect the pedicle is relevant. The aim of this study was a long-term evaluation of the patency of vascular pedicle of propeller flaps.
Methods:
In a retrospective clinical study, 22 patients who underwent soft-tissue reconstruction with a propeller flap were evaluated after 43 months. A Doppler probe was used to locate and evaluate the patency of the vascular pedicle of the flap.
Results:
The flaps were used in the lower extremity in 19 cases, on the trunk in 3 cases. All flaps had healed. In all patients, an intact vascular pedicle could be found. Flap size, source vessel, or infection could therefore not be linked to an increased risk of pedicle loss.
Conclusions:
The vascular pedicle of propeller flaps remains patent in the long term. This allows reelevation and undermining of the flap. We therefore recommend protecting the pedicle in all secondary cases to prevent later flap loss.
Hintergrund
Die Fotodokumentation von offenen Frakturen, Wunden, Dekubitalulzera, Tumoren oder Infektionen ist ein wichtiger Bestandteil der digitalen Patientenakte. Bisher ist unklar, welchen Stellenwert diese Fotodokumentation bei der Abrechnungsprüfung durch den Medizinischen Dienst der Krankenkassen (MDK) hat.
Fragestellung
Kann eine Smartphone-basierte Fotodokumentation die Verteidigung von erlösrelevanten Diagnosen und Prozeduren sowie der Verweildauer verbessern?
Material und Methoden
Ausstattung der Mitarbeiter mit digitalen Endgeräten (Smartphone/Tablet) in den Bereichen Notaufnahme, Schockraum, OP, Sprechstunden sowie auf den Stationen. Retrospektive Auswertung der Abrechnungsprüfung im Jahr 2019 und Identifikation aller Fallbesprechungen, in denen die Fotodokumentation eine Erlösveränderung bewirkt hat.
Ergebnisse
Von insgesamt 372 Fallbesprechungen half die Fotodokumentation in 27 Fällen (7,2 %) zur Bestätigung eines Operationen- und Prozedurenschlüssels (OPS) (n = 5; 1,3 %), einer Hauptdiagnose (n = 10; 2,7 %), einer Nebendiagnose (n = 3; 0,8 %) oder der Krankenhausverweildauer (n = 9; 2,4 %). Pro oben genanntem Fall mit Fotodokumentation ergab sich eine durchschnittliche Erlössteigerung von 2119 €. Inklusive Aufwandpauschale für die Verhandlungen wurde somit ein Gesamtbetrag von 65.328 € verteidigt.
Diskussion
Der Einsatz einer Smartphone-basierten Fotodokumentation kann die Qualität der Dokumentation verbessern und Erlöseinbußen bei der Abrechnungsprüfung verhindern. Die Implementierung digitaler Endgeräte mit entsprechender Software ist ein wichtiger Teil des digitalen Strukturwandels in Kliniken.