Refine
Has Fulltext
- yes (3)
Is part of the Bibliography
- yes (3)
Document Type
- Journal article (2)
- Doctoral Thesis (1)
Keywords
- APERIO (1)
- APERIO Hybrid (1)
- Hyperkapnie (1)
- Phase II trials (1)
- Subarachnoidalblutung (1)
- cerebrovascular disorders (1)
- clinical trials (1)
- mechanical thrombectomy (1)
- neurology (1)
- neurovascular disorders (1)
Temporary hypercapnia has been shown to increase cerebral blood flow (CBF) and might be used as a therapeutical tool in patients with severe subarachnoid hemorrhage (SAH). It was the aim of this study was to investigate the optimum duration of hypercapnia. This point is assumed to be the time at which buffer systems become active, cause an adaptation to changes of the arterial partial pressure of carbon dioxide (PaCO2) and annihilate a possible therapeutic effect. In this prospective interventional study in a neurosurgical ICU the arterial partial pressure of carbon dioxide (PaCO\(_2\)) was increased to a target range of 55 mmHg for 120 min by modification of the respiratory minute volume (RMV) one time a day between day 4 and 14 in 12 mechanically ventilated poor-grade SAH-patients. Arterial blood gases were measured every 15 min. CBF and brain tissue oxygen saturation (StiO\(_2\)) were the primary and secondary end points. Intracranial pressure (ICP) was controlled by an external ventricular drainage. Under continuous hypercapnia (PaCO\(_2\) of 53.17 ± 5.07), CBF was significantly elevated between 15 and 120 min after the start of hypercapnia. During the course of the trial intervention, cardiac output also increased significantly. To assess the direct effect of hypercapnia on brain perfusion, the increase of CBF was corrected by the parallel increase of cardiac output. The maximum direct CBF enhancing effect of hypercapnia of 32% was noted at 45 min after the start of hypercapnia. Thereafter, the CBF enhancing slowly declined. No relevant adverse effects were observed. CBF and StiO\(_2\) reproducibly increased by controlled hypercapnia in all patients. After 45 min, the curve of CBF enhancement showed an inflection point when corrected by cardiac output. It is concluded that 45 min might be the optimum duration for a therapeutic use and may provide an optimal balance between the benefits of hypercapnia and risks of a negative rebound effect after return to normal ventilation parameters.
Background
It is unknown whether technological advancement of stent-retriever devices influences typical observational indicators of safety or effectiveness.
Methods
Observational retrospective study of APERIO® (AP) vs. new generation APERIO® Hybrid (APH) (Acandis®, Pforzheim, Germany) stent-retriever device (01/2019–09/2020) for mechanical thrombectomy (MT) in large vessel occlusion (LVO) stroke. Primary effectiveness endpoint was successful recanalization eTICI (expanded Thrombolysis In Cerebral Ischemia) ≥ 2b67, primary safety endpoint was occurrence of hemorrhagic complications after MT. Secondary outcome measures were time from groin puncture to first pass and successful reperfusion, and the total number of passes needed to achieve the final recanalization result.
Results
A total of 298 patients with LVO stroke who were treated by MT matched the inclusion criteria: 148 patients (49.7%) treated with AP vs. 150 patients (50.3%) treated with new generation APH. Successful recanalization was not statistically different between both groups: 75.7% for AP vs. 79.3% for APH; p = 0.450. Postinterventional hemorrhagic complications and particularly subarachnoid hemorrhage as the entity possibly associated with stent-retriever device type was significantly less frequent in the group treated with the APH: 29.7% for AP and 16.0% for APH; p = 0.005; however, rates of symptomatic hemorrhage with clinical deterioration and in domo mortality were not statistically different. Neither the median number of stent-retriever passages needed to achieve final recanalization, time from groin puncture to first pass, time from groin puncture to final recanalization nor the number of cases in which successful recanalization could only be achieved by using a different stent-retriever as bail-out device differed between both groups.
Conclusion
In the specific example of the APERIO® stent-retriever device, we observed that further technological developments of the new generation device were not associated with disadvantages with respect to typical observational indicators of safety or effectiveness.
In einer vorangegangenen Phase-1-Studie wurde beobachtet, dass bei Patienten mit schwerer aneurysmatischer SAB, die CBF durch intermittierende kontrollierte Hyperkapnie erhöht werden kann. Zudem zeigte sich in dieser vorherigen Studie nach dem Zurücksetzen der mechanischen Beatmung auf die Ausgangsparameter eine langsame und asymptotische Rückkehr der CBF zu den Ausgangsniveaus ohne einen negativen Rebound-Effekt. Diese Beobachtung legte nahe, dass eine längere Dauer der Hyperkapnie den CBF-erhöhenden Effekt verlängern kann.
Die vorliegende Studie wurde als Dosisoptimierungsstudie geplant, um den Zeitpunkt zu bestimmen, zu dem der CBF ein Maximum erreicht, und unter der Annahme, dass nach diesem Maximum Puffermechanismen in Blut und Liquor zu Anpassungsmechanismen führen können, die nach dem Abbruch zu einem negativen Rebound-Effekt führen.
Es ergab sich eine "Netto" - Optimaldauer der Hyperkapnieintervention von 45 Minuten.