• Deutsch
  • Home
  • Search
  • Browse
  • Publish
  • Help
Schließen

Refine

Has Fulltext

  • yes (1)

Is part of the Bibliography

  • yes (1)

Year of publication

  • 2022 (1)

Document Type

  • Journal article (1)

Language

  • English (1)

Keywords

  • KWIC (1)
  • TT\(_{1rho}\) mapping (1)
  • T\(_{1P}\) dispersion (1)
  • T\(_{1P}\) mapping (1)
  • cardiac (1)
  • mice (1)
  • radial (1)
  • small animal (1)
  • spin lock (1)

Author

  • Arias-Loza, Paula Anahi (1)
  • Gensler, Daniel (1)
  • Gram, Maximilian (1)
  • Jakob, Peter Michael (1)
  • Nordbeck, Peter (1)
  • Oberberger, Johannes (1)
  • Seethaler, Michael (1)
  • Winter, Patrick (1)

Institute

  • Deutsches Zentrum für Herzinsuffizienz (DZHI) (1)
  • Klinik und Poliklinik für Nuklearmedizin (1)
  • Medizinische Klinik und Poliklinik I (1)
  • Physikalisches Institut (1)

1 search hit

  • 1 to 1
  • BibTeX
  • CSV
  • RIS
  • XML
  • 10
  • 20
  • 50
  • 100
Fast myocardial T\(_{1P}\) mapping in mice using k-space weighted image contrast and a Bloch simulation-optimized radial sampling pattern (2022)
Gram, Maximilian ; Gensler, Daniel ; Winter, Patrick ; Seethaler, Michael ; Arias-Loza, Paula Anahi ; Oberberger, Johannes ; Jakob, Peter Michael ; Nordbeck, Peter
Purpose T\(_{1P}\) dispersion quantification can potentially be used as a cardiac magnetic resonance index for sensitive detection of myocardial fibrosis without the need of contrast agents. However, dispersion quantification is still a major challenge, because T\(_{1P}\) mapping for different spin lock amplitudes is a very time consuming process. This study aims to develop a fast and accurate T\(_{1P}\) mapping sequence, which paves the way to cardiac T1ρ dispersion quantification within the limited measurement time of an in vivo study in small animals. Methods A radial spin lock sequence was developed using a Bloch simulation-optimized sampling pattern and a view-sharing method for image reconstruction. For validation, phantom measurements with a conventional sampling pattern and a gold standard sequence were compared to examine T\(_{1P}\) quantification accuracy. The in vivo validation of T\(_{1P}\) mapping was performed in N = 10 mice and in a reproduction study in a single animal, in which ten maps were acquired in direct succession. Finally, the feasibility of myocardial dispersion quantification was tested in one animal. Results The Bloch simulation-based sampling shows considerably higher image quality as well as improved T\(_{1P}\) quantification accuracy (+ 56%) and precision (+ 49%) compared to conventional sampling. Compared to the gold standard sequence, a mean deviation of - 0.46 ± 1.84% was observed. The in vivo measurements proved high reproducibility of myocardial T\(_{1P}\) mapping. The mean T\(_{1P}\) in the left ventricle was 39.5 ± 1.2 ms for different animals and the maximum deviation was 2.1% in the successive measurements. The myocardial T\(_{1P}\) dispersion slope, which was measured for the first time in one animal, could be determined to be 4.76 ± 0.23 ms/kHz. Conclusion This new and fast T\(_{1P}\) quantification technique enables high-resolution myocardial T\(_{1P}\) mapping and even dispersion quantification within the limited time of an in vivo study and could, therefore, be a reliable tool for improved tissue characterization.
  • 1 to 1

DINI-Zertifikat     OPUS4 Logo

  • Contact
  • |
  • Imprint
  • |
  • Sitemap