Refine
Has Fulltext
- yes (3)
Is part of the Bibliography
- yes (3)
Document Type
- Journal article (3)
Language
- English (3)
Keywords
- Aplastic anemia (1)
- Chirurgie (1)
- Hematopoietic cell transplant (1)
- Survival (1)
- aggregation (1)
- bead models (1)
- biopharmaceuticals (1)
- field flow fractionation (1)
- fluorescence-detected sedimentation (1)
- hydrodynamics (1)
Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304\(\pm\)0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of \(\pm\)0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies.
We report on 499 patients with severe aplastic anemia aged >= 50 years who underwent hematopoietic cell transplantation (HCT) from HLA-matched sibling (n = 275, 55%) or HLA-matched (8/8) unrelated donors (n =187, 37%) between 2005 and 2016. The median age at HCT was 57.8 years; 16% of patients were 65 to 77 years old. Multivariable analysis confirmed higher mortality risks for patients with performance score less than 90% (hazard ratio HR], 1.41; 95% confidence interval [CI], 1.03 to 1.92; P= .03) and after unrelated donor transplantation (HR, 1.47; 95% CI,1 to 2.16; P = .05). The 3-year probabilities of survival for patients with performance scores of 90 to 100 and less than 90 after HLA-matched sibling transplant were 66% (range, 57% to 75%) and 57% (range, 47% to 76%), respectively. The corresponding probabilities after HLA-matched unrelated donor transplantation were 57% (range, 48% to 67%) and 48% (range, 36% to 59%). Age at transplantation was not associated with survival, but grades II to IV acute graft-versus-host disease (GVHD) risks were higher for patients aged 65 years or older (subdistribution HR [sHR], 1.7; 95% confidence interval, 1.07 to 2.72; P= .026). Chronic GVHD was lower with the GVHD prophylaxis regimens calcineurin inhibitor (CNI) + methotrexate (sHR, .52; 95% CI, .33 to .81; P= .004) and CNI alone or with other agents (sHR, .27; 95% CI, .14 to .53; P < .001) compared with CNI + mycophenolate. Although donor availability is modifiable only to a limited extent, choice of GVHD prophylaxis and selection of patients with good performance scores are key for improved outcomes. (C) 2018 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.