Refine
Has Fulltext
- yes (19)
Is part of the Bibliography
- yes (19)
Year of publication
Document Type
- Journal article (19)
Keywords
- surgery (4)
- Barbed suture (1)
- Barbed suture material (1)
- Blepharoplastik (1)
- Digitalisierung (1)
- Elderly patients (1)
- Flexor tendon repair (1)
- Gesundheits-App (1)
- Knotless tendon repair (1)
- Künstliche Intelligenz (1)
Institute
- Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II) (18)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (3)
- Abteilung für Funktionswerkstoffe der Medizin und der Zahnheilkunde (1)
- Institut für Anatomie und Zellbiologie (1)
- Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I) (1)
- Klinik und Poliklinik für Dermatologie, Venerologie und Allergologie (1)
- Klinik und Poliklinik für Mund-, Kiefer- und Plastische Gesichtschirurgie (1)
- Lehrstuhl für Orthopädie (1)
- Lehrstuhl für Tissue Engineering und Regenerative Medizin (1)
- Medizinische Klinik und Poliklinik II (1)
Die operative Verjüngung des Auges stellt einen der am häufigsten nachgefragten Eingriffe im ästhetischen Spektrum dar. Die multikulturelle Bevölkerungsstruktur bedingt, dass auch „asiatisch“ imponierende Augen behandelt werden. „Asiatische“ Augen sind aber nicht nur bei Asiaten anzutreffen, sondern in unterschiedlicher Ausprägung auch bei Patienten aus dem Nahen und Mittleren Osten. Das asiatische Auge stellt in Bezug auf Verjüngungsmöglichkeiten eine eigene Entität dar. Während die klassische „Korrektur“ des asiatischen Auges eine etablierte und durch eine Vielzahl von verschiedenen Techniken mit vorhersehbaren Ergebnissen verbundene Methode ist, ist eine „verjüngende“ Blepharoplastik des asiatischen Auges komplexer zu bewerten [1, 3, 5, 10]. Die Operationsmethoden für das „asiatische“ Auge sind für jüngere Patienten intendiert, bei denen es überwiegend um die Korrektur des Epikanthus geht. Diese Techniken ziehen eine gewünschte Veränderung des periorbitalen Erscheinungsbildes nach sich, wobei das asiatische Aussehen teilweise zugunsten eines vermehrt „europäischen“ Aussehens beeinflusst wird. Fraglich bleibt, ob eine Veränderung zu einem europäischen Aussehen hin auch bei einem alternden Patienten einer Verjüngung gleichkommt. Prinzipiell imponiert ein derart operiertes asiatisches Auge „künstlich“, eine Tatsache die bei alternden Patienten als noch störender als der Alterungsprozess selbst empfunden werden dürfte. Daher ist der Wunsch nach einer Verjüngung ohne Verlust des typischen asiatischen Erscheinungsbildes des Auges chirurgisch nicht mit der klassischen Technik bei Europäern umzusetzen. Während die Behandlung durch eine klassische Blepharoplastik ein unnatürliches Aussehen zur Folge hat, kann unter Respektierung der asiatischen anatomischen Besonderheiten eine natürlich wirkende Verjüngung erreicht werden.
Background:
Pedicled perforator flaps have expanded reconstructive options in extremity reconstruction. Despite preoperative mapping, intraoperative findings may require microvascular tissue transfer when no adequate perforators can be found. The free peroneal artery perforator flap may serve as a reliable back-up plan in small defects.
Methods:
In 16 patients with small soft tissue defects on the upper and lower extremities, perforator-based propeller flaps were planned. The handheld Doppler device was used to localize potential perforators for a propeller flap in close proximity to the defect. Perforators of the proximal peroneal artery were also marked to allow conversion to microvascular tissue transfer.
Results:
In 6 cases, no adequate perforators were found intraoperatively. In 4 patients, the peroneal artery perforator flap was harvested and transferred. The pedicle length did not exceed 4 cm. No flap loss occurred.
Conclusions:
When no adequate perforator capable of nourishing a propeller flap can be found intraoperatively, the free peroneal artery flap is a good option to reconstruct small soft tissue defects in the distal extremities. The short vascular pedicle is less ideal in cases with a large zone of injury requiring a more distant site of anastomosis or when recipient vessels are located in deeper tissue planes.
Objectives
Triangular fibrocartilage complex (TFCC) injuries frequently cause ulnar-sided wrist pain and can induce distal radioulnar joint instability. With its complex three-dimensional structure, diagnosis of TFCC lesions remains a challenging task even in MR arthrograms. The aim of this study was to assess the added diagnostic value of radial reformatting of isotropic 3D MRI datasets compared to standard planes after direct arthrography of the wrist.
Methods
Ninety-three patients underwent wrist MRI after fluoroscopy-guided multi-compartment arthrography. Two radiologists collectively analyzed two datasets of each MR arthrogram for TFCC injuries, with one set containing standard reconstructions of a 3D thin-slice sequence in axial, coronal and sagittal orientation, while the other set comprised an additional radial plane view with the rotating center positioned at the ulnar styloid. Surgical reports (whenever available) or radiological reports combined with clinical follow-up served as a standard of reference. In addition, diagnostic confidence and assessability of the central disc and ulnar-sided insertions were subjectively evaluated.
Results
Injuries of the articular disc, styloid and foveal ulnar attachment were present in 20 (23.7%), 10 (10.8%) and 9 (9.7%) patients. Additional radial planes increased diagnostic accuracy for lesions of the styloid (0.83 vs. 0.90; p = 0.016) and foveal (0.86 vs. 0.94; p = 0.039) insertion, whereas no improvement was identified for alterations of the central cartilage disc. Readers' confidence (p < 0.001) and assessability of the ulnar-sided insertions (p < 0.001) were superior with ancillary radial reformatting.
Conclusions
Access to the radial plane view of isotropic 3D sequences in MR arthrography improves diagnostic accuracy and confidence for ulnar-sided TFCC lesions.
Hintergrund
Die Fotodokumentation von offenen Frakturen, Wunden, Dekubitalulzera, Tumoren oder Infektionen ist ein wichtiger Bestandteil der digitalen Patientenakte. Bisher ist unklar, welchen Stellenwert diese Fotodokumentation bei der Abrechnungsprüfung durch den Medizinischen Dienst der Krankenkassen (MDK) hat.
Fragestellung
Kann eine Smartphone-basierte Fotodokumentation die Verteidigung von erlösrelevanten Diagnosen und Prozeduren sowie der Verweildauer verbessern?
Material und Methoden
Ausstattung der Mitarbeiter mit digitalen Endgeräten (Smartphone/Tablet) in den Bereichen Notaufnahme, Schockraum, OP, Sprechstunden sowie auf den Stationen. Retrospektive Auswertung der Abrechnungsprüfung im Jahr 2019 und Identifikation aller Fallbesprechungen, in denen die Fotodokumentation eine Erlösveränderung bewirkt hat.
Ergebnisse
Von insgesamt 372 Fallbesprechungen half die Fotodokumentation in 27 Fällen (7,2 %) zur Bestätigung eines Operationen- und Prozedurenschlüssels (OPS) (n = 5; 1,3 %), einer Hauptdiagnose (n = 10; 2,7 %), einer Nebendiagnose (n = 3; 0,8 %) oder der Krankenhausverweildauer (n = 9; 2,4 %). Pro oben genanntem Fall mit Fotodokumentation ergab sich eine durchschnittliche Erlössteigerung von 2119 €. Inklusive Aufwandpauschale für die Verhandlungen wurde somit ein Gesamtbetrag von 65.328 € verteidigt.
Diskussion
Der Einsatz einer Smartphone-basierten Fotodokumentation kann die Qualität der Dokumentation verbessern und Erlöseinbußen bei der Abrechnungsprüfung verhindern. Die Implementierung digitaler Endgeräte mit entsprechender Software ist ein wichtiger Teil des digitalen Strukturwandels in Kliniken.
Background: The soft tissue of the central pretibial area is difficult to reconstruct often requiring free tissue transfer. Especially medi- cally compromised patients are not ideal candidates for free tissue transfer and may benefit from expeditiously harvested local flaps with limited donor site morbidity. As muscle flaps are rare, pedi- cled flaps based on lateral perforators represent an alternative as the arc of rotation can often be limited to 90 °.
Material and Methods: A retrospective analysis of patient data was conducted to identify patients over the age of 60 years with comor- bidities that underwent pretibial soft tissue reconstruction with a single-pedicle perforator flap. Patient demographics, size and cause of the defect, flap dimension, arc of rotation and complications were recorded.
Results: Five patients with an average age of 71.4 years were in- cluded. The arc of rotation was 69 °, all flaps healed. There were two recurrences of osteomyelitis.
Conclusion: Lateral perforators originating from the anterior tib- ial artery or peroneal artery are adequate source vessels for single pedicled perforator flaps even in medically compromised patients. A perforator located proximal to the defect allows limiting the arcof rotation to less than 90 °, which increases the safety of the flap. Patients benefit from a simple procedure without a microvascular anastomosis and a donor site confined to one extremity
Background:
Flap reconstruction of the distal lower extremity is challenging. Especially, the concept of perforator surgery has increased available surgical options. Although results are generally judged in terms of objective facts, patients-perceived quality of life has largely remained unexamined. The aim of the study was to compare quality of life after lower extremity reconstruction with pedicled and free flaps.
Methods:
Patients were evaluated retrospectively after reconstruction of defects of the distal lower extremity either with distally based adipofascial sural flap (pedicled reverse sural flap) or an anterior lateral thigh (ALT) flap. A specific questionnaire was developed to measure the patient’s quality of life, based on short form health survey-12, Dresden Body Image Score-35, Patient Health Questionnaire-4, and XSMFA questionnaires with additional specific questions. Furthermore, results, secondary surgeries, and complications were analyzed.
Results:
Thirty-seven patients with reconstruction of lower limb defects treated with a pedicled reverse sural flap and 34 patients treated with an ALT flap were included in the study. There was no statistical significant difference in the overall satisfaction with the procedure in the long-term follow-up between both groups, but patients with ALT showed a higher satisfaction with the treatment in the initial postoperative period. Both groups demonstrated approximately similar results in the long term for self-acceptance and vitality.
Conclusions:
Although anatomic situation may dictate flap choice coverage with free flaps, a less-complicated flap is by no means regarded as an inferior treatment option in patient’s estimation. Despite the intuitive speculation that patients with more advanced reconstruction methods should have better function and subsequently higher quality of life, this assumption was clearly not supported by data in this study.
Background:
Although indocyanine-green fluorescence angiography (ICG-FA) has been established as a useful tool to assess perfusion in free tissue transfer, only few studies have applied this modality to pedicled perforator flaps. As both volume and reach of pedicled perforator flaps are limited and tip necrosis often equals complete flap failure, ICG-FA may help to detect hypoperfusion in pedicled flaps.
Methods:
In 5 patients, soft tissue reconstruction was achieved with pedicled perforator flaps. ICG-FA was utilized intraoperatively to visualize flap perfusion.
Results:
Three pedicled anterolateral thigh flap flaps and 2 propeller flaps were transferred. ICG-FA detected hypoperfusion in 2 flaps. No flap loss occurred; in 2 cases, prolonged wound healing was encountered.
Conclusions:
ICG-FA confirmed clinical findings and reliably detected tissue areas with hypoperfusion. A clear cut-off point between nonvital tissue and such that stabilized in the following clinical course could not be found. ICG-FA is a promising technology which could also be used in pedicled perforator flaps.
Background: Intraarticular distal radius fractures can be treated with many methods. While internal fixation with angle stable implants has become increasingly popular, the use of bone graft substitutes has also been recommended to address comminution zones and thus increase stability. Whether a combination of both methods will improve clinical outcomes was the purpose of the study Methods: The study was thus conducted as a prospective randomized clinical trial. 39 patients with unilateral, intraarticular fractures of the distal radius were included and randomized to 2 groups, one being treated with internal fixation only, while the second group received an additional bone graft substitute. Results: There was no statistical significance between both groups in functional and radiological results. The occurrence of complications did also not show statistical significance. Conclusions: No advantage of additional granular bone graft substitutes could be seen in this study. Granular bone graft substitutes do not seem to provide extra stability if dorsal angle stable implants are used. Dorsal plates have considerable complication rates such as extensor tendon ruptures and development of CRPS.
Muscle cuff in distal pedicled adipofascial sural artery flaps: a retrospective case control study
(2021)
Background:
Amputation after open tibial fracture occurs in 3% of cases. The rate increases when flap reconstruction is required. The standard care involves microsurgical tissue transfer although the pedicled reverse sural artery adipofascial flap (PRSAF) is a local alternative in patients endangered by a prolonged operative time. Incorporation of a gastrocnemius muscle cuff in this flap can be used to fill dead space and increase healing potential. Literature shows superior survival rates for both PRSAF and inclusion of a muscle cuff in comparison with the cutaneous version. The aim of the study was to compare the outcome of the PRSAF and the musculoadipofascial version (PRSMAF). We hypothesize that the PRSMAF provides similar lap viability and flap-related complication rates as does the adipofascial version. The muscle component may reduce the long-term osteomyelitis rate.
Methods:
Patients were evaluated retrospectively after reconstruction with either PRSAF or PRSMAF. Preoperative osteomyelitis, flap survival, complications and osteomyelitis clearance were analyzed.
Results:
The study shows preliminary results supporting the potential use of the PRSMAF. We compare either 23 PRSMAF or 20 PRSAF flaps. We found no statistically significant differences in flap survival or in complication rate.
Conclusions:
Although the anatomical situation may sometimes dictate the use of a free flap, a technically less-complicated option may in some cases offer a viable alternative. This study shows that the PRSMAF can serve as an alternative for complex bone defects in the limb, though it does not provide statistical improvement to the PRSAF.
Background:
Bone-ligament-bone grafts for reconstruction of the scapholunate ligament are a valuable tool to prevent disease progression to carpal collapse. Locally available grafts do not require an additional donor site. The first extensor compartment was evaluated biomechanically regarding its possible use as an autograft.
Methods:
Twelve native fresh-frozen, human cadaver specimens were tested by applying axial tension in a Zwick Roell machine. Load to failure, transplant elongation, and bony avulsion were recorded. The load to failure was quantitated in newtons (N) and the displacement in length (millimeters). Parameters were set at distinct points as start of tension, 1 mm stretch and 1.5 mm dissociation, failure and complete tear, and were evaluated under magnified visual control. Although actual failure occurred at higher tension, functional failure was defined at a stretch of 1.5 mm.
Results:
Mean load at 1 mm elongation was 44.1 ± 28 N and at 1.5 mm elongation 57.5 ± 42 N. Failure occurred at 111 ± 83.1 N. No avulsion of the bony insertion was observed. Half the transplants failed in the central part of the ligament, while the rest failed near the insertion but not at the insertion itself. Analysis of tension strength displayed a wide range from 3.8 to 83.7 N/mm at a mean of 33.4 ± 28.4 N/mm.
Conclusions:
The biomechanical tensile properties of the first dorsal extensor compartment are similar to those of the dorsal part of the scapholunate ligament. A transplant with a larger bone stock and a longer ligament may display an advantage, as insertion is possible in the dorsal, easily accessible part of the carpal bones rather than in the arête-like region adjacent to the insertion of the scapholunate ligament. In this study, 1.5 mm lengthening of the bone–ligament–bone transplant was defined as clinical failure, as such elongation will cause severe gapping and is considered as failure of the transplant.