Refine
Has Fulltext
- yes (15)
Is part of the Bibliography
- yes (15)
Year of publication
Document Type
- Journal article (15)
Keywords
- Coronavirus (2)
- Injury Severity Score (2)
- Intensivkapazitäten (2)
- Pandemie (2)
- Polytrauma (2)
- classification (2)
- AO (1)
- AS clavicle plate (1)
- Beckenfraktur (1)
- Beckenring (1)
Institute
- Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II) (15)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (3)
- Institut für Anatomie und Zellbiologie (2)
- Klinik und Poliklinik für Anästhesiologie (ab 2004) (2)
- Neurochirurgische Klinik und Poliklinik (1)
- Physiologisches Institut (1)
- Urologische Klinik und Poliklinik (1)
Purpose
Displaced midshaft clavicular fractures can be treated conservatively as well as operatively by titan elastic nail (TEN) or plate fixation. This survey was performed to evaluate the clinical results of each treatment method and elaborate advantages or possible complications of each modality.
Methods
Between 2008 and 2013, 102 patients were prospectively included in our study—37 patients for conservative treatment with a rucksack bandage for 4 to 6 weeks, 41 patients for plate osteosynthesis, and 24 for intramedullary stabilization with TEN. Disabilities of the Arm, Shoulder and Hand (DASH), Constant Murley Score (CMS), and visual analog scale (VAS) for pain and function as well as time of invalidity were recorded over a 1-year period.
Results
The clinical data collected reveals that all three different therapies lead to good or excellent clinical results after 1 year. However, one can observe advantages of operative treatment in comparison to conservative therapy in some characteristics.
Conclusion
Our data shows that there are several indications where operative treatment has advantages compared to conservative treatment. In special fracture types (Robinson 2B1), TEN gives the best results. Plate fixation is extraordinarily sufficient in pain reduction within the first 5 weeks and indicated in more-part fractures (Robinson 2B2). Nevertheless, conservative treatment is always a good and promising way to treat clavicular fractures, so that individual indications and thorough patient informative talks are inevitable.
Background
The Goutallier Classification is a semi quantitative classification system to determine the amount of fatty degeneration in rotator cuff muscles. Although initially proposed for axial computer tomography scans it is currently applied to magnet-resonance-imaging-scans. The role for its clinical use is controversial, as the reliability of the classification has been shown to be inconsistent. The purpose of this study was to compare the semi quantitative MRI-based Goutallier Classification applied by 5 different raters to experimental MR spectroscopic quantitative fat measurement in order to determine the correlation between this classification system and the true extent of fatty degeneration shown by spectroscopy.
Methods
MRI-scans of 42 patients with rotator cuff tears were examined by 5 shoulder surgeons and were graduated according to the MRI-based Goutallier Classification proposed by Fuchs et al. Additionally the fat/water ratio was measured with MR spectroscopy using the experimental SPLASH technique. The semi quantitative grading according to the Goutallier Classification was statistically correlated with the quantitative measured fat/water ratio using Spearman’s rank correlation.
Results
Statistical analysis of the data revealed only fair correlation of the Goutallier Classification system and the quantitative fat/water ratio with R = 0.35 (p < 0.05). By dichotomizing the scale the correlation was 0.72. The interobserver and intraobserver reliabilities were substantial with R = 0.62 and R = 0.74 (p < 0.01).
Conclusion
The correlation between the semi quantitative MRI based Goutallier Classification system and MR spectroscopic fat measurement is weak. As an adequate estimation of fatty degeneration based on standard MRI may not be possible, quantitative methods need to be considered in order to increase diagnostic safety and thus provide patients with ideal care in regard to the amount of fatty degeneration. Spectroscopic MR measurement may increase the accuracy of the Goutallier classification and thus improve the prediction of clinical results after rotator cuff repair. However, these techniques are currently only available in an experimental setting.
Background
Suture pretension during tendon repair is supposed to increase the resistance to gap formation. However, its effects on the Bunnell suture technique are unknown. The purpose of this study was to determine the biomechanical effects of suture pretension on the Bunnell and cross-lock Bunnell techniques for tendon repair.
Methods
Eighty porcine hindlimb tendons were randomly assigned to four different tendon repair groups: those repaired with or without suture pretension using either a simple Bunnell or cross-lock Bunnell technique. Pretension was applied as a 10 % shortening of the sutured tendon. After measuring the cross-sectional diameter at the repair site, static and cyclic biomechanical tests were conducted to evaluate the initial and 5-mm gap formation forces, elongation during cyclic loading, maximum tensile strength, and mode of failure. The suture failure mechanism was also separately assessed fluoroscopically in two tendons that were repaired with steel wire.
Results
Suture pretension was accompanied by a 10 to 15 % increase in the tendon diameter at the repair site. Therefore, suture pretension with the Bunnell and cross-lock Bunnell repair techniques noticeably increased the resistance to initial gap formation and 5-mm gap formation. The tension-free cross-lock Bunnell repair demonstrated more resistance to initial and 5-mm gap formation, less elongation, and higher maximum tensile strength than the tension-free Bunnell repair technique. The only difference between the tensioned cross-lock Bunnell and tensioned Bunnell techniques was a larger resistance to 5-mm gap formation with the cross-lock Bunnell technique. Use of the simple instead of cross-lock suture configuration led to failure by suture cut out, as demonstrated fluoroscopically.
Conclusion
Based on these results, suture pretension decreases gapping and elongation after tendon repair, and those effects are stronger when using a cross-lock, rather than a regular Bunnell suture. However, pretension causes an unfavorable increase in the tendon diameter at the repair site, which may adversely affect wound healing.
Background
Morphology and glenoid involvement determine the necessity of surgical management in scapula fractures. While being present in only a small share of patients with shoulder trauma, numerous classification systems have been in use over the years for categorization of scapula fractures. The purpose of this study was to evaluate the established AO/OTA classification in comparison to the classification system of Euler and Rüedi (ER) with regard to interobserver reliability and confidence in clinical practice.
Methods
Based on CT imaging, 149 patients with scapula fractures were retrospectively categorized by two trauma surgeons and two radiologists using the classification systems of ER and AO/OTA. To measure the interrater reliability, Fleiss kappa (κ) was calculated independently for both fracture classifications. Rater confidence was stated subjectively on a five-point scale and compared with Wilcoxon signed rank tests. Additionally, we computed the intraclass correlation coefficient (ICC) based on absolute agreement in a two-way random effects model to assess the diagnostic confidence agreement between observers.
Results
In scapula fractures involving the glenoid fossa, interrater reliability was substantial (κ = 0.722; 95% confidence interval [CI] 0.676–0.769) for the AO/OTA classification in contrast to moderate agreement (κ = 0.579; 95% CI 0.525–0.634) for the ER classification system. Diagnostic confidence for intra-articular fracture patterns was superior using the AO/OTA classification compared to ER (p < 0.001) with higher confidence agreement (ICC: 0.882 versus 0.831). For extra-articular fractures, ER (κ = 0.817; 95% CI 0.771–0.863) provided better interrater reliability compared to AO/OTA (κ = 0.734; 95% CI 0.692–0.776) with higher diagnostic confidence (p < 0.001) and superior agreement between confidence ratings (ICC: 0.881 versus 0.912).
Conclusions
The AO/OTA classification is most suitable to categorize intra-articular scapula fractures with glenoid involvement, whereas the classification system of Euler and Rüedi appears to be superior in extra-articular injury patterns with fractures involving only the scapula body, spine, acromion and coracoid process.
Operative treatment of ruptured pubic symphysis by plating is often accompanied by complications. Trans-obturator cable fixation might be a more reliable technique; however, have not yet been tested for stabilization of ruptured pubic symphysis. This study compares symphyseal trans-obturator cable fixation versus plating through biomechanical testing and evaluates safety in a cadaver experiment. APC type II injuries were generated in synthetic pelvic models and subsequently separated into three different groups. The anterior pelvic ring was fixed using a four-hole steel plate in Group A, a stainless steel cable in Group B, and a titan band in Group C. Biomechanical testing was conducted by a single-leg-stance model using a material testing machine under physiological load levels. A cadaver study was carried out to analyze the trans-obturator surgical approach. Peak-to-peak displacement, total displacement, plastic deformation and stiffness revealed a tendency for higher stability for trans-obturator cable/band fixation but no statistical difference to plating was detected. The cadaver study revealed a safe zone for cable passage with sufficient distance to the obturator canal. Trans-obturator cable fixation has the potential to become an alternative for symphyseal fixation with less complications.
Introduction
Reverse shoulder arthroplasty (RSA) leads to medialization and distalization of the centre of rotation of the shoulder joint resulting in lengthening of the deltoid muscle. Shear wave ultrasound elastography (SWE) is a reliable method for quantifying tissue stiffness. The purpose of this study was to analyse if deltoid muscle tension after RSA correlates with the patients' pain level. We hypothesized that higher deltoid muscle tension would be associated with increased pain.
Material and methods
Eighteen patients treated with RSA were included. Constant score (CS) and pain level on the visual analogue scale (VAS) were analysed and SWE was performed on both shoulders. All three regions of the deltoid muscle were examined in resting position and under standardized isometric loading.
Results
Average patient age was 76 (range 64-84) years and average follow-up was 15 months (range 4-48). The average CS was 66 points (range 35-89) and the average pain level on the VAS was 1.8 (range 0.5-4.7). SWE revealed statistically significant higher muscle tension in the anterior and middle deltoid muscle region in patients after RSA compared to the contralateral non-operated side. There was a statistically significant correlation between pain level and anterior deltoid muscle tension.
Conclusion
SWE revealed increased tension in the anterior and middle portion of the deltoid muscle after RSA in a clinical setting. Increased tension of the anterior deltoid muscle portion significantly correlated with an increased pain level. SWE is a powerful, cost-effective, quick, dynamic, non-invasive, and radiation-free imaging technique to evaluate tissue elasticity in the shoulder with a wide range of applications.
Background
Traumatic separation of the pubic symphysis can destabilize the pelvis and require surgical fixation to reduce symphyseal gapping. The traditional approach involves open reduction and the implantation of a steel symphyseal plate (SP) on the pubic bone to hold the reposition. Despite its widespread use, SP-fixation is often associated with implant failure caused by screw loosening or breakage.
Methods
To address the need for a more reliable surgical intervention, we developed and tested two titanium cable-clamp implants. The cable served as tensioning device while the clamp secured the cable to the bone. The first implant design included a steel cable anterior to the pubic symphysis to simplify its placement outside the pelvis, and the second design included a cable encircling the pubic symphysis to stabilize the anterior pelvic ring. Using highly reproducible synthetic bone models and a limited number of cadaver specimens, we performed a comprehensive biomechanical study of implant stability and evaluated surgical feasibility.
Results
We were able to demonstrate that the cable-clamp implants provide stability equivalent to that of a traditional SP-fixation but without the same risks of implant failure. We also provide detailed ex vivo evaluations of the safety and feasibility of a trans-obturator surgical approach required for those kind of fixation.
Conclusion
We propose that the developed cable-clamp fixation devices may be of clinical value in treating pubic symphysis separation.
Background:
Flap reconstruction of the distal lower extremity is challenging. Especially, the concept of perforator surgery has increased available surgical options. Although results are generally judged in terms of objective facts, patients-perceived quality of life has largely remained unexamined. The aim of the study was to compare quality of life after lower extremity reconstruction with pedicled and free flaps.
Methods:
Patients were evaluated retrospectively after reconstruction of defects of the distal lower extremity either with distally based adipofascial sural flap (pedicled reverse sural flap) or an anterior lateral thigh (ALT) flap. A specific questionnaire was developed to measure the patient’s quality of life, based on short form health survey-12, Dresden Body Image Score-35, Patient Health Questionnaire-4, and XSMFA questionnaires with additional specific questions. Furthermore, results, secondary surgeries, and complications were analyzed.
Results:
Thirty-seven patients with reconstruction of lower limb defects treated with a pedicled reverse sural flap and 34 patients treated with an ALT flap were included in the study. There was no statistical significant difference in the overall satisfaction with the procedure in the long-term follow-up between both groups, but patients with ALT showed a higher satisfaction with the treatment in the initial postoperative period. Both groups demonstrated approximately similar results in the long term for self-acceptance and vitality.
Conclusions:
Although anatomic situation may dictate flap choice coverage with free flaps, a less-complicated flap is by no means regarded as an inferior treatment option in patient’s estimation. Despite the intuitive speculation that patients with more advanced reconstruction methods should have better function and subsequently higher quality of life, this assumption was clearly not supported by data in this study.
Background:
Reverse oblique distal radio-ulnar joint (DRUJ) configuration is assumed to show inferior postoperative results in ulnar-shortening osteotomy due to osteoarthritis, as the joint force pressure in the DRUJ may be increased. An evaluation and comparison of the postoperative functional results with regard to clinical and radiographic signs of arthritis among different DRUJ configurations was carried out retrospectively.
Methods:
Sixty-two patients after ulnar shortening osteotomy were included. The minimum follow-up was 5 years. Preoperative x-rays were assessed for the DRUJ configuration according to the Tolat classification, whereas postoperative radiographs were evaluated with regard to signs of osteoarthritis using the Kallgren-Lawrence-Score. Functional results were evaluated using the disabilities of the arm, shoulder and hand (DASH) and Mayo Wrist Score and measuring range of motion and grip strength.
Results:
Significantly better functional results were found in patients with parallel configuration of the DRUJ (Tolat type 1 configuration) with regard to DASH score, grip strength, and supination compared with nonparallel configurations. In the Tolat type 1, configurated DRUJ mean DASH score was 9 compared with 18 in the Tolat type 2 and 3 groups. Apart from supination, no differences were observed in range of motion among groups.
Conclusion:
Although long-term postoperative range of motion failed to display statistically significant differences between DRUJ configurations except for supination, better results regarding grip strength and DASH scores were seen in a parallel-aligned DRUJ configuration. Although onset of osteoarthritis does not seem to become apparent within the observation period, nonparallel aligned configuration predisposes to inferior results.
Background:
Propeller flaps require torsion of the vascular pedicle of up to 180 degrees. Contrary to free flaps, where the relevance of an intact vascular pedicle has been documented, little is known regarding twisted pedicles of propeller flaps. As secondary surgeries requiring undermining of the flap are common in the extremities, knowledge regarding the necessity to protect the pedicle is relevant. The aim of this study was a long-term evaluation of the patency of vascular pedicle of propeller flaps.
Methods:
In a retrospective clinical study, 22 patients who underwent soft-tissue reconstruction with a propeller flap were evaluated after 43 months. A Doppler probe was used to locate and evaluate the patency of the vascular pedicle of the flap.
Results:
The flaps were used in the lower extremity in 19 cases, on the trunk in 3 cases. All flaps had healed. In all patients, an intact vascular pedicle could be found. Flap size, source vessel, or infection could therefore not be linked to an increased risk of pedicle loss.
Conclusions:
The vascular pedicle of propeller flaps remains patent in the long term. This allows reelevation and undermining of the flap. We therefore recommend protecting the pedicle in all secondary cases to prevent later flap loss.