Refine
Has Fulltext
- yes (4)
Is part of the Bibliography
- yes (4)
Document Type
- Journal article (4)
Language
- English (4)
Keywords
- Biochemie (1)
- Cytoskeleton (1)
- GAAS (1)
- blood gas analysis (1)
- data display (1)
- diagnostic correctness (1)
- homeostasisIon channels (1)
- point-of-care (1)
- situation awareness (1)
- thrombopoiesis (1)
Institute
Sonstige beteiligte Institutionen
The human gene encoding the myogenic determination factor myf3 (mouse MyoD1) has been mapped to the short arm of chromosome 11. Analysis of several somatic cell hybrids containing various derivatives with deletions or translocations revealed that the human MyoD (MYF3) gene is not associated with the WAGR locus at chromosomal band 11pl3 nor with the loss of the heterozygosity region at 11p15.5 related to the Beckwith-Wiedemann syndrome. Subregional mapping by in situ hybridization with an myf3 specific probe shows that the gene resides at the chromosomal band llp14, possibly at llp14.3.
In this letter we study the influence of temperature and excitation power on the emission linewidth from site-controlled InGaAs/GaAs quantum dots grown on nanoholes defined by electron beam lithography and wet chemical etching. We identify thermal electron activation as well as direct exciton loss as the dominant intensity quenching channels. Additionally, we carefully analyze the effects of optical and acoustic phonons as well as close-by defects on the emission linewidth by means of temperature and power dependent micro-photoluminescence on single quantum dots with large pitches. (C) 2014 Author(s).
Mg\(^{2+}\) plays a vital role in platelet function, but despite implications for life-threatening conditions such as stroke or myocardial infarction, the mechanisms controlling [Mg\(^{2+}\)]i in megakaryocytes (MKs) and platelets are largely unknown. Transient receptor potential melastatin-like 7 channel (TRPM7) is a ubiquitous, constitutively active cation channel with a cytosolic α-kinase domain that is critical for embryonic development and cell survival. Here we report that impaired channel function of TRPM7 in MKs causes macrothrombocytopenia in mice (Trpm7\(^{fl/fl-Pf4Cre}\)) and likely in several members of a human pedigree that, in addition, suffer from atrial fibrillation. The defect in platelet biogenesis is mainly caused by cytoskeletal alterations resulting in impaired proplatelet formation by Trpm7\(^{fl/fl-Pf4Cre}\) MKs, which is rescued by Mg\(^{2+}\) supplementation or chemical inhibition of non-muscle myosin IIA heavy chain activity. Collectively, our findings reveal that TRPM7 dysfunction may cause macrothrombocytopenia in humans and mice.
Interpreting blood gas analysis results can be challenging for the clinician, especially in stressful situations under time pressure. To foster fast and correct interpretation of blood gas results, we developed Visual Blood. This computer-based, multicentre, noninferiority study compared Visual Blood and conventional arterial blood gas (ABG) printouts. We presented six scenarios to anaesthesiologists, once with Visual Blood and once with the conventional ABG printout. The primary outcome was ABG parameter perception. The secondary outcomes included correct clinical diagnoses, perceived diagnostic confidence, and perceived workload. To analyse the results, we used mixed models and matched odds ratios. Analysing 300 within-subject cases, we showed noninferiority of Visual Blood compared to ABG printouts concerning the rate of correctly perceived ABG parameters (rate ratio, 0.96; 95% CI, 0.92–1.00; p = 0.06). Additionally, the study revealed two times higher odds of making the correct clinical diagnosis using Visual Blood (OR, 2.16; 95% CI, 1.42–3.29; p < 0.001) than using ABG printouts. There was no or, respectively, weak evidence for a difference in diagnostic confidence (OR, 0.84; 95% CI, 0.58–1.21; p = 0.34) and perceived workload (Coefficient, 2.44; 95% CI, −0.09–4.98; p = 0.06). This study showed that participants did not perceive the ABG parameters better, but using Visual Blood resulted in more correct clinical diagnoses than using conventional ABG printouts. This suggests that Visual Blood allows for a higher level of situation awareness beyond individual parameters’ perception. However, the study also highlighted the limitations of today’s virtual reality headsets and Visual Blood.