Einleitung: Die linksventrikuläre diastolische Dysfunktion (LVDD) ist bei Diabetikern noch vor Entwicklung einer klinisch apparenten Herzinsuffizienz eines der ersten Anzeichen einer kardialen Beteiligung. Daher soll in dieser Studie untersucht werden, ob die LVDD mit ECG-gated F-18-FDG PET in einem Diabetes-Rattenmodell dargestellt werden kann.
Methodik: Es wurden F-18-FDG PET Scans in einem Typ-2-Diabetes Rattenmodell (ZDF fa/fa, n=6) und in ZL Kontrollen (n=6) vorgenommen (Alter, jeweils 13 Wochen). Unter Hyperinsulinemic-Euglycemic Clamp-Technik wurden 37 MBq 18F-FDG über die Schwanzvene appliziert. 15-35 Minuten nach Tracergabe wurden mittels eines Kleintier-PET-Scanners sowie unter EKG-Ableitung PET Scans angefertigt (16 frames/cardiac cycle). Die linksventrikuläre Ejektionsfraktion (EF) und die Peak Füllrate (PFR) wurden mittels einer geeigneten Software (Heart Function View) gemessen, wobei die Software an die Größe des Rattenherzes angepasst wurde.
Ergebnisse: Im Alter von 13 Wochen entwickeln ZDF Diabetes-Ratten eine im Vergleich zu Kontrolltieren eine signifikante myokardiale Hypertrophie, bestätigt durch post-mortem Analyse des Herzgewichtes (994±78mg vs. 871±44mg in ZDF Diabetes-Ratten vs. ZL Kontrollen, p<0.01). ECG-gated PET zeigte eine signifikante Abnahme der LV diastolischen PFR (10.4±0.5 vs. 11.8±0.4 EDV/sec in ZDF Diabetes-Ratten vs. ZL Kontrollen, p<0.001), jedoch zeigte sich kein signifikanter Unterschied zwischen LVEF und der Herzfrequenz in den untersuchten ZDF Diabetes-Ratten und Kontrollen (LVEF: 60.0±4.5 vs. 63.7±4.1%, n.s. und HR: 305±25 vs. 323±24 bpm, n.s.).
Schlussfolgerung: Im Diabetes-Ratten-Modell kann unter Verwendung eines ECG-gated FDG-PET Protokolls die diastolische Dysfunktion als Parameter der frühen diabetischen Kardiomyopathie nachgewiesen werden.
Background: Precise regional quantitative assessment of renal function is limited with conventional \(^{99m}\)Tc-labeled renal radiotracers. A recent study reported that the positron emission tomography (PET) radiotracer 2-deoxy-2-(\(^{18}\)F-fluorosorbitol (\(^{18}\)F-FDS) has ideal pharmacokinetics for functional renal imaging. Furthermore, (\(^{18}\)F-FDS is available via simple reduction from routinely used 2-deoxy-2-(\(^{18}\)F-fluoro-D-glucose ((\(^{18}\)F-FDG). We aimed to further investigate the potential of (\(^{18}\)F-FDS PET as a functional renal imaging agent using rat models of kidney diseases.
Methods: Two different rat models of renal impairment were investigated: Glycerol induced acute renal failure (ARF) by intramuscular administration of glycerol in hind legs and unilateral ureteral obstruction (UUO) by ligation of the left ureter. 24h after these treatments, dynamic 30 min 18F-FDS PET data were acquired using a dedicated small animal PET system. Urine 18F-FDS radioactivity 30 min after radiotracer injection was measured together with co-injected \(^{99m}\)Tc-diethylenetriaminepentaacetic acid (\(^{99m}\)Tc-DTPA) urine activity. Results: Dynamic PET imaging demonstrated rapid (\(^{18}\)F-FDS accumulation in the renal cortex and rapid radiotracer excretion via kidneys in control healthy rats. On the other hand, significantly delayed renal radiotracer uptake (continuous slow uptake) was observed in ARF rats and UUO-treated kidneys. Measured urine radiotracer concentrations of (\(^{18}\)F-FDS and \(^{99m}\)Tc-DTPA were well correlated (R=0.84, P<0.05).
Conclusions: (\(^{18}\)F-FDS PET demonstrated favorable kinetics for functional renal imaging in rat models of kidney diseases. Advantages of high spatiotemporal resolution of PET imaging and simple tracer production could potentially complement or replace conventional renal scintigraphy in select cases and significantly improve the diagnostic performance of renal functional imaging.
Brown adipose tissue (BAT) is an attractive therapeutic target to combat diabetes and obesity due to its ability to increase glucose expenditure. In a genetic rat model (ZDF fa/fa) of type-2 diabetes and obesity, we aimed to investigate glucose utilization of BAT by \(^{18}\)F-FDG PET imaging. Male Zucker diabetic fatty (ZDF) and Male Zucker lean (ZL) control rats were studied at 13 weeks. Three weeks prior to imaging, ZDF rats were randomized into a no-restriction (ZDF-ND) and a mild calorie restriction (ZDF-CR) group. Dynamic \(^{18}\)F-FDG PET using a dedicated small animal PET system was performed under hyperinsulinemic-euglycemic clamp. \(^{18}\)F-FDG PET identified intense inter-scapular BAT glucose uptake in all ZL control rats, while no focally increased \(^{18}\)F-FDG uptake was detected in all ZDF-ND rats. Mild but significant improved BAT tracer uptake was identified after calorie restriction in diabetic rats (ZDF-CR). The weight of BAT tissue and fat deposits were significantly increased in ZDF-CR and ZDF-ND rats as compared to ZL controls, while UCP-1 and mitochondrial concentrations were significantly decreased. Whitening and severely impaired insulin-stimulated glucose uptake in BAT was confirmed in a rat model of type-2 diabetes. Additionally, calorie restriction partially restored the impaired BAT glucose uptake.
In diabetic cardiomyopathy, left ventricular (LV) diastolic dysfunction is one of the earliest signs of cardiac involvement prior to the definitive development of heart failure (HF). We aimed to explore the LV diastolic function using electrocardiography (ECG)-gated \(^{18}\)F-fluorodeoxyglucose positron emission tomography (\(^{18}\)F-FDG PET) imaging beyond the assessment of cardiac glucose utilization in a diabetic rat model. ECG-gated \(^{18}\)F-FDG PET imaging was performed in a rat model of type 2 diabetes (ZDF fa/fa) and ZL control rats at age of 13 weeks (n=6, respectively). Under hyperinsulinemic-euglycemic clamp to enhance cardiac activity, \(^{18}\)F-FDG was administered and subsequently, list-mode imaging using a dedicated small animal PET system with ECG signal recording was performed. List-mode data were sorted and reconstructed into tomographic images of 16 frames per cardiac cycle. Left ventricular functional parameters (systolic: LV ejection fraction (EF), heart rate (HR) vs. diastolic: peak filling rate (PFR)) were obtained using an automatic ventricular edge detection software. No significant difference in systolic function could be obtained (ZL controls vs. ZDF rats: LVEF, 62.5±4.2 vs. 59.4±4.5%; HR: 331±35 vs. 309±24 bpm; n.s., respectively). On the contrary, ECG-gated PET imaging showed a mild but significant decrease of PFR in the diabetic rats (ZL controls vs. ZDF rats: 12.1±0.8 vs. 10.2±1 Enddiastolic Volume/sec, P<0.01). Investigating a diabetic rat model, ECG-gated \(^{18}\)F-FDG PET imaging detected LV diastolic dysfunction while systolic function was still preserved. This might open avenues for an early detection of HF onset in high-risk type 2 diabetes before cardiac symptoms become apparent.