Das Ziel dieser retrospektiven Studie war der Vergleich zwischen den zwei am häufigsten durchgeführten mikroinzisionalen Glaukomoperationen (Trabectome und iStent inject) in Bezug auf die Reduktion des Augeninnendrucks und der Anzahl der Glaukommedikamente, da diese operative Verfahren zunehmend eine Alternative für die traditionellen Glaukomoperationen in den verschiedenen Glaukomstadien darstellen.
In dieser Studie wurden alle Patienten eingeschlossen, die in der Zeit zwischen Januar 2008 und März 2018 in unserer Klinik und Satelliten entweder Trabectome oder iStent inject bekommen haben. Die beiden Gruppen wurden in allen Fällen mit Phakoemulsifikation und Intraokularlinsenimplantation kombiniert. Um die Wahrscheinlichkeit von Exact Matching mit den neuen iStent inject zu erhöhen, wo nur wenige Daten existieren, wurden die verfügbaren Daten von iStent inject mit Daten von 3446 Patienten aus der Datenbank der Trabectome Study Group gematcht. Der postoperative Beobachtungszeitraum betrug 24 Monate. Bei jedem Patienten wurden in dieser Zeit der Augeninnendruck und die Anzahl der Glaukommedikamente analysiert. Die zwei exakt gematchten Gruppen hatten den gleichen präoperativen Augeninnendruck von 18,3 ± 5,1 mmHg und die gleiche Anzahl der präoperativ angewendeten Glaukommedikamente von 2,7 ± 1,2.
In der iStent inject Gruppe wurde ein Augeninnendruck von 14,6 ± 4,2 mmHg nach drei Monaten erreicht, der zunehmend im Verlauf ab dem sechsten Monat stieg und über dem Basisdurchschnitt am Ende der Studie lag (18,8 ± 9,0 mmHg). In der Trabectome Gruppe war der Augeninnendruck nach einem Monat auf ein Minimum von 13,1 ± 3,2 mmHg reduziert und er blieb während der gesamten Beobachtungszeit in diesem Niveau (14,2 ± 3,5 mmHg nach 24 Monaten). Die Trabectome Gruppe hatte bei allen postoperativen Nachkontrollen einen durchschnittlich niedrigeren Augeninnendruck als in der iStent inject Gruppe.
In der iStent inject Gruppe sank die Anzahl der Glaukommedikamente bis zum dritten Monat auf 1,7 ± 1,4, und dann stieg sie ab dem sechsten Monat an, sodass es im Monat 12 keinen signifikanten Unterschied im Vergleich zur präoperativen Medikamentenanzahl mehr gab (2,0 ± 1,5 nach 24 Monaten). In der Trabectome Gruppe sanken die Glaukommedikamente von der exakt gematchten Zahl der Patienten von 2,7 ± 1,2 zum Studienbeginn auf 1,6 ± 1,3 in sechs Monaten und auf 1,5 ± 1,4 nach 24 Monaten.
Unter Verwendung der Erfolgsdefinition, die üblicherweise für die mikroinzisionalen Glaukomoperationen angewendet wird (eine Augeninnendrucksenkung um ≥ 20 % des Ausgangsdrucks oder ein Augeninnendruck von < 21 mmHg), erreichten 97 % der Patienten der Trabectome Gruppe und 95 % der Patienten der iStent inject Gruppe dieses Ziel.
Dieser ausgewogene Vergleich zwischen den zwei Gruppen mittels Exact Matchings zeigte, dass die Senkung des Augeninnendrucks und der Anzahl der Glaukommedikamente bei Trabectome größer und anhaltender ist als bei iStent inject.
Purpose
To achieve a highly balanced comparison of trabecular bypass stenting (IS2, iStent inject) with ab interno trabeculectomy (T, Trabectome) by exact matching.
Methods
Fifty-three IS2 eyes were matched to 3446 T eyes. Patients were matched using exact matching by baseline intraocular pressure (IOP), the number of glaucoma medications, and glaucoma type, and using nearest neighbor matching by age. Individuals without a close match were excluded. All surgeries were combined with phacoemulsification.
Results
A total of 78 eyes (39 in each group) could be matched as exact pairs with a baseline IOP of 18.3 ± 5.1 mmHg and glaucoma medications of 2.7 ± 1.2 in each. IOP in IS2 was reduced to 14.6 ± 4.2 mmHg at 3 months and in T to a minimum of 13.1 ± 3.2 mmHg at 1 month. In IS2, IOP began to rise again at 6 months, eventually exceeding baseline. At 24 months, IOP in IS2 was 18.8 ± 9.0 mmHg and in T 14.2 ± 3.5 mmHg. IS2 had a higher average IOP than T at all postoperative visits (p < 0.05 at 1, 12, 18 months). Glaucoma medications decreased to 2.0 ± 1.5 in IS2 and to 1.5 ± 1.4 in T.
Conclusion
T resulted in a larger and sustained IOP reduction compared with IS2 where a rebound occurred after 6 months to slightly above preoperative values.
Purpose
We used exact matching for a highly balanced comparison of ab interno trabeculectomy (AIT) with the trabectome to trabeculectomy with mitomycin C (TRAB).
Methods
A total of 5485 patients who underwent AIT were exact-matched to 196 TRAB patients by baseline intraocular pressure (IOP), number of glaucoma medications, and glaucoma type. Nearest-neighbor–matching was applied to age. Success was defined as a final IOP of less than 21 mmHg, IOP reduction of at least 20% reduction from baseline, and no secondary surgical interventions. Outcomes were measured at 1, 3, 6, 12, 18, and 24 months.
Results
A total of 165 AIT could be matched to 165 TRAB. The mean baseline IOP was 22.3 ± 5.6 mmHg, and the baseline number of glaucoma medications was 2.7 ± 1.1 in both groups. At 24 months, IOP was reduced to 15.8 ± 5.2 mmHg in AIT and 12.4 ± 4.7 mmHg in TRAB. IOP was lower than baseline at all visits (p < 0.01) and lower in TRAB than AIT (p < 0.01). Glaucoma medications were reduced to 2.1 ± 1.3 in AIT and 0.2 ± 0.8 in TRAB. Compared to baseline, patients used fewer drops postoperatively (p < 0.01) and more infrequently in TRAB than in AIT (p > 0.01). Secondary surgical interventions had the highest impact on success and became necessary in 15 AIT and 59 TRAB patients. Thirty-two challenging events occurred in TRAB and none in AIT.
Conclusion
Both AIT and TRAB reduced IOP and medications. This reduction was more significant in TRAB but at the expense of four times as many secondary interventions.
Indoor house dust is a blend of organic and inorganic materials, upon which diverse microbial communities such as viruses, bacteria and fungi reside. Adequate moisture in the indoor environment helps microbial communities multiply fast. The outdoor air and materials that are brought into the buildings by airflow, sandstorms, animals pets and house occupants endow the indoor dust particles with extra features that impact human health. Assessment of the health effects of indoor dust particles, the type of indoor microbial inoculants and the secreted enzymes by indoor insects as allergens merit detailed investigation. Here, we discuss the applications of next generation sequencing (NGS) technology which is used to assess microbial diversity and abundance of the indoor dust environments. Likewise, the applications of NGS are discussed to monitor the gene expression profiles of indoor human occupants or their surrogate cellular models when exposed to aqueous solution of collected indoor dust samples. We also highlight the detection methods of dust allergens and analytical procedures that quantify the chemical nature of indoor particulate matter with a potential impact on human health. Our review is thus unique in advocating the applications of interdisciplinary approaches that comprehensively assess the health effects due to bad air quality in built environments.