Refine
Has Fulltext
- yes (5)
Is part of the Bibliography
- yes (5)
Document Type
- Doctoral Thesis (5)
Language
- English (5) (remove)
Keywords
- Cardiac Efficiency (1)
- Circadian (1)
- Coronary heart disease (1)
- Dünndarm (1)
- ECG-gated PET (1)
- Echocardiography (1)
- Echokardiographie (1)
- HFpEF (1)
- Heart Failure (1)
- Herzinsuffizienz (1)
Institute
Sonstige beteiligte Institutionen
The main function of the small intestine is the absorption of essential nutrients, water and vitamins. Moreover, it constitutes a barrier protecting us from toxic xenobiotics and pathogens. For a better understanding of these processes, the development of intestinal in vitro models is of great interest to the study of pharmacological and pathological issues such as transport mechanisms and barrier function. Depending on the scientific questions, models of different complexity can be applied.
In vitro Transwell® systems based on a porous PET-membrane enable the standardized study of transport mechanisms across the intestinal barrier as well as the investigation of the influence of target substances on barrier integrity. However, this artificial setup reflects only limited aspects of the physiology of the native small intestine and can pose an additional physical barrier. Hence, the applications of this model for tissue engineering are limited.
Previously, tissue models based on a biological decellularized scaffold derived from porcine gut tissue were demonstrated to be a good alternative to the commonly used Transwell® system. This study showed that preserved biological extracellular matrix components like collagen and elastin provide a natural environment for the epithelial cells, promoting cell adhesion and growth. Intestinal epithelial cells such as Caco-2 cultured on such a scaffold showed a confluent, tight monolayer on the apical surface. Additionally, myofibroblasts were able to migrate into the scaffold supporting intestinal barrier formation.
In this thesis, dendritic cells were additionally introduced to this model mimicking an important component of the immune system. This co-culture model was then successfully proven to be suitable for the screening of particle formulations developed as delivery system for cancer antigens in peroral vaccination studies. In particular, nanoparticles based on PLGA, PEG-PAGE-PLGA, Mannose-PEG-PAGE-PLGA and Chitosan were tested. Uptake studies revealed only slight differences in the transcellular transport rate among the different particles. Dendritic cells were shown to phagocytose the particles after they have passed the intestinal barrier. The particles demonstrated to be an effective carrier system to transport peptides across the intestinal barrier and therefore present a useful tool for the development of novel drugs.
Furthermore, to mimic the complex structure and physiology of the gut including the presence of multiple different cell types, the Caco-2 cell line was replaced by primary intestinal cells to set up a de novo tissue model. To that end, intestinal crypts including undifferentiated stem cells and progenitor cells were isolated from human small intestinal tissue samples (jejunum) and expanded in vitro in organoid cultures. Cells were cultured on the decellularized porcine gut matrix in co-culture with intestinal myofibroblasts. These novel tissue models were maintained under either static or dynamic conditions.
Primary intestinal epithelial cells formed a confluent monolayer including the major differentiated cell types positive for mucin (goblet cells), villin (enterocytes), chromogranin A (enteroendocrine cells) and lysozyme (paneth cells). Electron microscopy images depicted essential functional units of an intact epithelium, such as microvilli and tight junctions. FITC-dextran permeability and TEER measurements were used to assess tightness of the cell layer. Models showed characteristic transport activity for several reference substances. Mechanical stimulation of the cells by a dynamic culture system had a great impact on barrier integrity and transporter activity resulting in a tighter barrier and a higher efflux transporter activity.
In Summary, the use of primary human intestinal cells combined with a biological decellularized scaffold offers a new and promising way to setup more physiological intestinal in vitro models. Maintenance of primary intestinal stem cells with their proliferation and differentiation potential together with adjusted culture protocols might help further improve the models. In particular, dynamic culture systems and co culture models proofed to be a first crucial steps towards a more physiological model. Such tissue models might be useful to improve the predictive power of in vitro models and in vitro in vivo correlation (IVIVC) studies. Moreover, these tissue models will be useful tools in preclinical studies to test pharmaceutical substances, probiotic active organisms, human pathogenic germs and could even be used to build up patient-specific tissue model for personalized medicine.
DD is a cardiac disturbance, which has gained increasing importance in recent years due to its important role in different cardiac disease and cardiomyopathies including ischemic cardiomyopathy, arterial hypertension and diabetic cardiomyopathy.
ECG-gated 18F-FDG PET is an imaging technique, that can distinguish between districts of myocardial viability and myocardial scars and further provides information of great interest on the efficacy of experimental approaches designed to improve the cardiac function and/or myocardial metabolism in experimental small animal models. However, ECG-gated 18F-FDG PET is a technique whose feasibility in the assessment of the LV diastolic function in small animals has not been a subject of study.
In this thesis, the ability of the ECG-gated 18F-FDG PET for the assessment of both the systolic and diastolic function in eight control rats and in seven ZDF rats, which are an experimental animal model mimicking T2DM conditions and diabetic related complications in humans including DCM, has been investigated The ECG-gated 18F-FDG PET imaging was performed under hyperinsulinemic-euglycemic clamping and the data were stored in list mode files and retrospectively reconstructed. The systolic and diastolic parameters were achieved from the time/volume and the time/filling curve calculated from the software HFV. Additionally, the influence of the number of gates per cardiac cycle on the LV volumes and function parameters has been studied.
Hyperinsulinemic-euglycemic clamp procedure and blood glucose measurement did confirm the development of a manifest diabetes in the ZDF rats at the timepoint of the experiments.
Regarding the systolic parameters, no significant difference could be detected between the ZDF and ZL rats. The values for the CO were similar in both groups, which demonstrates a similar LV systolic function in the ZDF and the ZL rats at the age of 13 weeks. Values for the systolic parameters are in good line with previous PET, MRI and cardiac catheterization-based studies in diabetic rats.
The main finding of this study was that by using in vivo ECG-gated 18F-FDG PET and the software HFV, reliable diastolic parameters could be calculated. Moreover, it was possible to detect the presence of a mild impaired diastolic filling in the ZDF rats in absence of any systolic alteration. This impaired diastolic function in an early stage of diabetes could also be detected by other investigators, who used echocardiography or cardiac catheterization. Therefore, this is the first study showing, that the assessment of the diastolic function in rats can be carried out by ECG-gated 18F-FDG PET imaging.
In conclusion, additionally to calculating LV volumes and LV EF, ECG-gated 18F-FDG PET can evaluate the diastolic function of healthy and diabetic rats and is able to detect a DD in ZDF rats.
Background
Tobacco smoking is accountable for more than one in ten deaths in patients with cardiovascular disease. Thus, smoking cessation has a high priority in secondary prevention of coronary heart disease (CHD). The present study meant to assess smoking cessation patterns, identify parameters associated with smoking cessation and investigate personal reasons to change or maintain smoking habits in patients with established CHD.
Methods
Quality of CHD care was surveyed in 24 European countries in 2012/13 by the fourth European Survey of Cardiovascular Disease Prevention and Diabetes. Patients 18 to 79 years of age at the date of the CHD index event hospitalized due to first or recurrent diagnosis of coronary artery bypass graft, percutaneous coronary intervention, acute myocardial infarction or acute myocardial ischemia without infarction (troponin negative) were included. Smoking status and clinical parameters were iteratively obtained a) at the cardiovascular disease index event by medical record abstraction, b) during a face-to-face interview 6 to 36 months after the index event (i.e. baseline visit) and c) by telephone-based follow-up interview two years after the baseline visit. Parameters associated with smoking status at the time of follow-up interview were identified by logistic regression analysis. Personal reasons to change or maintain smoking habits were assessed in a qualitative interview and analyzed by qualitative content analysis.
Results
One hundred and four of 469 (22.2%) participants had been classified current smokers at the index event and were available for follow-up interview. After a median observation period of 3.5 years (quartiles 3.0, 4.1), 65 of 104 participants (62.5%) were classified quitters at the time of follow-up interview. There was a tendency of diabetes being more prevalent in quitters vs non-quitters (37.5% vs 20.5%, p=0.07). Higher education level (15.4% vs 33.3%, p=0.03) and depressed mood (17.2% vs 35.9%, p=0.03) were less frequent in quitters vs non-quitters. Quitters more frequently participated in cardiac rehabilitation programs (83.1% vs 48.7%, p<0.001). Cardiac rehabilitation appeared as factor associated with smoking cessation in multivariable logistic regression analysis (OR 5.19, 95%CI 1.87 to 14.46, p=0.002). Persistent smokers at telephone-based follow-up interview reported on addiction as wells as relaxation and pleasure as reasons to continue their habit. Those current and former smokers who relapsed at least once after a quitting attempt, stated future health hazards as their main reason to undertake quitting attempts. Prevalent factors leading to relapse were influence by their social network and stress. Successful quitters at follow-up interview referred to smoking-related harm done to their health having had been their major reason to quit.
Interpretation
Participating in a cardiac rehabilitation program was strongly associated with smoking cessation after a cardiovascular disease index event. Smoking cessation counseling and relapse prophylaxis may include alternatives for the pleasant aspects of smoking and incorporate effective strategies to resist relapse.
The mammalian central clock, located in the suprachiasmatic nucleus (SCN) of the anterior hypothalamus, controls circadian rhythms in behaviour such as the sleep-wake cycle. It is made up of approximately 20,000 heterogeneous neurons that can be classified by their expression of neuropeptides. There are three major populations: AVP neurons (arginine vasopressin), VIP neurons (vasoactive intestinal peptide), and GRP neurons (gastrin releasing peptide). How these neuronal clusters form functional units to govern various aspects of rhythmic behavior is poorly understood. At a molecular level, biological clocks are represented by transcriptional-posttranslational feedback loops that induce circadian oscillations in the electrical activity of the SCN and hence correlate with behavioral circadian rhythms. In mammals, the sleep wake cycle can be accurately predicted by measuring electrical muscle and brain activity. To investigate the link between the electrical activity of heterogeneous neurons of the SCN and the sleep wake cycle, we optogenetically manipulated AVP neurons in vivo with SSFO (stabilized step function opsin) and simultaneously recorded an electroencephalogram (EEG) and electromyogram (EMG) in freely moving mice. SSFO-mediated stimulation of AVP positive neurons in the anterior hypothalamus increased the total amount of wakefulness during the hour of stimulation. Interestingly, this effect led to a rebound in sleep in the hour after stimulation. Markov chain sleep-stage transition analysis showed that the depolarization of AVP neurons through SSFO promotes the transition from all states to wakefulness. After the end of stimulation, a compensatory increase in transitions to NREM sleep was observed. Ex vivo, SSFO activation in AVP neurons causes depolarization and modifies the activity of AVP neurons. Therefore, the results of this thesis project suggest an essential role of AVP neurons as mediators between circadian rhythmicity and sleep-wake behaviour.
1 Summary
Left ventricular (LV) ejection fraction (EF) and global longitudinal strain (GLS) are the most commonly used measures of LV function. Yet, they are highly dependent on loading conditions since higher afterload yields lower systolic deformation and thereby a lower LVEF and GLS – despite presumably unchanged LV myocardial contractile strength. Invasive pressure-volume loop measurements represent the reference standard to assess LV function, also considering loading conditions. However, this procedure cannot be used in serial investigations or large sample populations due to its invasive nature. The novel concept of echocardiography-derived assessment of myocardial work (MyW) is based on LV pressure-strain loops, may be a valuable alternative to overcome these challenges, and may also be used with relative ease in large populations. As MyW also accounts for afterload, it is considered less load-dependent than LVEF and GLS.
The current PhD work addresses the application and clinical characterization of MyW, an innovative echocardiographic tool. As the method is new, we focused on four main topics:
(a) To establish reference values for MyW indices, i.e., Global Work Index (GWI), Global Constructive Work (GCW), Global Wasted Work (GWW), and Global Work Efficiency (GWE); we addressed a wide age range and evaluated the association of MyW indices with age, sex and other clinical and echocardiography parameters in apparently cardiovascular healthy individuals.
(b) To investigate the impact of cardiovascular (CV) risk factors on MyW indices and characterize the severity of subclinical LV deterioration in the general population.
(c) To assess the association of the LV geometry, i.e., LV mass and dimensions, with MyW indices.
(d) To evaluate in-hospital dynamics of MyW indices in patients hospitalized for acute heart failure (AHF).
For the PhD thesis, we could make use of two larger cohorts:
The STAAB population-based cohort study prospectively recruited and phenotyped a representative sample (5,000 individuals) of the general population of the City of Würzburg, aged 30-79 years and free from symptomatic heart failure at the time of inclusion. We focused on the first half of the study sample (n=2473 individuals), which fulfilled the anticipated strata regarding age and sex.
The Acute Heart Failure (AHF) Registry is a prospective clinical registry recruiting and phenotyping consecutive patients admitted for decompensated AHF to the Department of Medicine I, University Hospital Würzburg, and observing the natural course of the disease. The AHF Registry focuses on the pathophysiological understanding, particularly in relation to the early phase after cardiac decompensation, with the aim to improve diagnosis and better-tailored treatment of patients with AHF. For the current study, we concentrated on patients who provided pairs of echocardiograms acquired early after index hospital admission and prior to discharge.
The main findings of the PhD thesis were:
From the STAAB cohort study, we determined the feasibility of large-scale MyW derivation and the accuracy of the method. We established reference values for MyW indices based on 779 analyzable, apparently healthy participants (mean age 49 ± 10 years, 59% women), who were in sinus rhythm, free from CV risk factors or CV disease, and had no significant LV valve disease. Apart from GWI, there were no associations of other MyW indices with sex. Further, we found a disparate association with age, where MyW showed stable values until the age of 45 years, with an upward shift occurring beyond the age of 45. A higher age decade was associated with higher GWW and lower GWE, respectively. MyW indices only correlated weakly with common echocardiographic parameters, suggesting that MyW may add incremental information to clinically established parameters.
Further analyses from the STAAB cohort study contributed to a better understanding of the impact of CV risk factors on MyW indices and the association of LV geometry with LV performance. We demonstrated that CV risk factors impacted selectively on GCW and GWW. Hypertension appears to profoundly compromise the work of the myocardium, in particular, by increasing both GCW and GWW. The LV in hypertension seems to operate at a higher energy level yet lower efficiency. Other classical CV risk factors (Diabetes mellitus, Obesity, Dyslipidemia, Smoking) – independent of blood pressure – impacted consistently and adversely on GCW but did not affect GWW. Further, all CV risk factors affected GWE adversely.
We observed that any deviation from a normal LV geometric profile was associated with alterations on MyW. Of note, MyW was sensitive to early changes in LV mass and dimensions. Individuals with normal LV geometry yet established arterial hypertension exhibited a MyW pattern that is typically found in LV hypertrophy. Therefore, such a pattern might serve as an early sign of myocardial damage in hypertensive heart disease and might aid in risk stratification and primary prevention.
From the AHF Registry, we selected individuals with serial in-hospital echocardiograms and described in-hospital changes in myocardial performance during recompensation. In patients presenting with a reduced ejection fraction (HFrEF), decreasing N-terminal pro-natriuretic peptide (NT-proBNP) levels as a surrogate of successful recompensation were associated with an improvement in GCW and GWI and consecutively in GWE. In contrast, in patients presenting with a preserved ejection fraction (HFpEF), there was no significant change in GCW and GWI. However, unsuccessful recompensation, i.e., no change or an increase in NT-proBNP levels, was associated with an increase in GWW. This suggests a differential myocardial response to de- and recompensation depending on the HF phenotype.
Further, GWW as a surrogate of inappropriate LV energy consumption was elevated in all patients with AHF (compared to reference values) and was not associated with conventional markers as LVEF or NT-proBNP. In an exploratory analysis, GWW predicted the risk of death or rehospitalization within six months after discharge. Hence, GWW might carry incremental information beyond conventional markers of HF severity.