Magnetic Resonance Imaging (MRI) is a non-invasive medical imaging technique, that is rou- tinely used in clinical practice for detection and diagnosis of a wide range of different diseases. In MRI, no ionizing radiation is used, making even repeated application unproblematic. This is an important advantage over other common imaging methods such as X-rays and Computer To- mography. One major drawback of MRI, however, are long acquisition times and associated high costs of experiments. Since the introduction of MRI, several important technical developments have been made to successfully reduce acquisition times. In this work, novel approaches were developed to increase the efficiency of MRI acquisitions.
In Chapter 4, an improved radial turbo spin-echo (TSE) combined acquisition and reconstruction strategy was introduced. Cartesian turbo spin-echo sequences [3] are widely used especially for the detection and diagnosis of neurological pathologies, as they provide high SNR images with both clinically important proton density and T2 contrasts. TSE acquisitions combined with radial sampling are very efficient, since it is possible to obtain a number of ETL images with different contrasts from a single radial TSE measurement [56–58]. Conventionally, images with a particular contrast are obtained from both radial and Cartesian TSE acquisitions by combining data from different echo times into a single image. In the radial case, this can be achieved by employing k-space weighted image contrast (KWIC) reconstruction. In KWIC, the center region of k-space is filled exclusively with data belonging to the desired contrast while outer regions also are assembled with data acquired at other echo times. However, this data sharing leads to mixed contrast contributions to both Cartesian and radial TSE images. This is true especially for proton density weighted images and therefore may reduce their diagnostic value.
In the proposed method, an adapted golden angle reordering scheme is introduced for radial TSE acquisitions, that allows a free choice of the echo train length and provides high flexibility in image reconstruction. Unwanted contrast contaminations are greatly reduced by employing a narrow-band KWIC filter, that restricts data sharing to a small temporal window around the de- sired echo time. This corresponds to using fewer data than required for fully sampled images and consequently leads to images exhibiting aliasing artifacts. In a second step, aliasing-free images are obtained using parallel imaging. In the neurological examples presented, the CG-SENSE algorithm [42] was chosen due to its stable convergence properties and its ability to reconstruct arbitrarily sampled data. In simulations as well as in different in vivo neurological applications, no unwanted contrast contributions could be observed in radial TSE images reconstructed with the proposed method. Since this novel approach is easy to implement on today’s scanners and requires low computational power, it might be valuable for the clinical breakthrough of radial TSE acquisitions.
In Chapter 5, an auto-calibrating method was introduced to correct for stimulated echo contribu- tions to T2 estimates from a mono-exponential fit of multi spin-echo (MSE) data. Quantification of T2 is a useful tool in clinical routine for the detection and diagnosis of diseases as well as for tis- sue characterization. Due to technical imperfections, refocusing flip angles in a MSE acquisition deviate from the ideal value of 180○. This gives rise to significant stimulated echo contributions to the overall signal evolution. Therefore, T2 estimates obtained from MSE acquisitions typically are notably higher than the reference. To obtain accurate T2 estimates from MSE acquisitions, MSE signal amplitudes can be predicted using the extended phase graph (EPG, [23, 24]) algo- rithm. Subsequently, a correction factor can be obtained from the simulated EPG T2 value and applied to the MSE T2 estimates. However, EPG calculations require knowledge about refocus- ing pulse amplitudes, T2 and T1 values and the temporal spacing of subsequent echoes. While the echo spacing is known and, as shown in simulations, an approximate T1 value can be assumed for high ratios of T1/T2 without compromising accuracy of the results, the remaining two parameters are estimated from the data themselves. An estimate for the refocusing flip angle can be obtained from the signal intensity ratio of the second to the first echo using EPG. A conventional mono- exponential fit of the MSE data yields a first estimate for T2. The T2 correction is then obtained iteratively by updating the T2 value used for EPG calculations in each step. For all examples pre- sented, two iterations proved to be sufficient for convergence. In the proposed method, a mean flip angle is extracted across the slice. As shown in simulations, this assumption leads to greatly reduced deviations even for more inhomogeneous slice profiles. The accuracy of corrected T2 values was shown in experiments using a phantom consisting of bottles filled with liquids with a wide range of different T2 values. While T2 MSE estimates were shown to deviate significantly from the spin-echo reference values, this is not the case for corrected T2 values. Furthermore, applicability was demonstrated for in vivo neurological experiments.
In Chapter 6, a new auto-calibrating parallel imaging method called iterative GROG was pre- sented for the reconstruction of non-Cartesian data. A wide range of different non-Cartesian schemes have been proposed for data acquisition in MRI, that present various advantages over conventional Cartesian sampling such as faster acquisitions, improved dynamic imaging and in- trinsic motion correction. However, one drawback of non-Cartesian data is the more complicated reconstruction, which is ever more problematic for non-Cartesian parallel imaging techniques. Iterative GROG uses Calibrationless Parallel Imaging by Structured Low-Rank Matrix Completion (CPI) for data reconstruction. Since CPI requires points on a Cartesian grid, it cannot be used to directly reconstruct non-Cartesian data. Instead, Grappa Operator Gridding (GROG) is employed in a first step to move the non-Cartesian points to the nearest Cartesian grid locations. However, GROG requires a fully sampled center region of k-space for calibration. Combining both methods in an iterative scheme, accurate GROG weights can be obtained even from highly undersampled non-Cartesian data. Subsequently, CPI can be used to reconstruct either full k- space or a calibration area of arbitrary size, which can then be employed for data reconstruction with conventional parallel imaging methods.
In Chapter 7, a new 2D sampling scheme was introduced consisting of multiple oscillating effi- cient trajectories (MOET), that is optimized for Compressed Sensing (CS) reconstructions. For successful CS reconstruction of a particular data set, some requirements have to be met. First, ev- ery data sample has to carry information about the whole object, which is automatically fulfilled for the Fourier sampling employed in MRI. Additionally, the image to be reconstructed has to be sparse in an arbitrary domain, which is true for a number of different applications. Last, data sam- pling has to be performed in an incoherent fashion. For 2D imaging, this important requirement of CS is difficult to achieve with conventional Cartesian and non-Cartesian sampling schemes. Ra- dial sampling is often used for CS reconstructions of dynamic data despite the streaking present in undersampled images. To obtain incoherent aliasing artifacts in undersampled images while at the same time preserving the advantages of radial sampling for dynamic imaging, MOET com- bines radial spokes with oscillating gradients of varying amplitude and alternating orientation orthogonal to the readout direction. The advantage of MOET over radial sampling in CS re- constructions was demonstrated in simulations and in in vivo cardiac imaging. MOET provides superior results especially when used in CS reconstructions with a sparsity constraint directly in image space. Here, accurate results could be obtained even from few MOET projections, while the coherent streaking artifacts present in the case of radial sampling prevent image recovery even for smaller acceleration factors. For CS reconstructions of dynamic data with sparsity constraint in xf-space, the advantage of MOET is smaller since the temporal reordering is responsible for an important part of incoherency. However, as was shown in simulations of a moving phantom and in the reconstruction of ungated cardiac data, the additional spatial incoherency provided by MOET still leads to improved results with higher accuracy and may allow reconstructions with higher acceleration factors.
Das Ziel dieser Promotion ist der Aufbau eines dreMR Setups für einen klinischen 1,5T Scanner, das die Relaxations-Dispersions-Bildgebung ermöglicht, und die anschließende Ergründung von möglichst vielen Anwendungsfeldern von dreMR. Zu der Aufgabe gehört die Bereitstellung der zugrunde liegenden Theorie, der Bau des experimentellen Setups (Offset-Spule und Stromversorgung) sowie die Programmierung der nötigen Software. Mit dem gebauten Setup konnten zwei große Anwendungsfelder — dreMR Messungen mit und ohne Kontrastmitteln — untersucht werden.
In dieser Arbeit wurden für spezielle Anwendungen an klinischen MR-Geräten optimierte Phased-Array-Spulen entwickelt. Das Ziel war, durch die Verwendung neuer Spulen entweder neue Anwendungsgebiete für klinische MR-Geräte zu eröffnen oder bei bestehenden Applikationen die Diagnosemöglichkeiten durch eine Kombination von höherem SNR und kleineren g-Faktoren im Vergleich zu bestehenden Spulen zu verbessern. In Kapitel 3 wurde untersucht, ob es durch den Einsatz neu entwickelter, dedizierter Kleintierspulen sinnvoll möglich ist, Untersuchungen an Kleintieren an klinischen MR-Geräten mit einer Feldstärke von 1,5T durchzuführen. Der Einsatz dieser Spulen verspricht dem klinischen Anwender Studien an Kleintieren durchführen zu können, bei denen er den gleichen Kontrast wie bei einer humanen Anwendung erhält und gleichzeitig Kontrastmittel sowie Sequenzen, die klinisch erprobt sind, einzusetzen. Durch die gewählten geometrischen Abmessungen der Spulen ist es möglich, Zubehör von dedizierten Tier-MR-Geräten, wie z. B. Tierliegen oder EKG- bzw. Atemtriggereinheiten, zu verwenden. Durch Vorversuche an für Ratten dimensionierten Spulen wurden grundlegende Zusammenhänge zwischen verwendetem Entkopplungsmechanismus und SNR bzw. Beschleunigungsfähigkeit erarbeitet. Für Ratten wurde gezeigt, dass in akzeptablen Messzeiten von unter fünf Minuten MR-Messungen des Abdomens in sehr guter Bildqualität möglich sind. Ebenfalls gezeigt wurde die Möglichkeit durch den Einsatz von paralleler Bildgebung sowie Kontrastmitteln hochaufgelöste Angiographien durchzuführen. Es stellte sich heraus, dass bei 1,5T dedizierte Mäusespulen bei Raumtemperatur von den SNR-Eigenschaften am Limit des sinnvoll Machbaren sind. Trotzdem war es möglich, auch für Mäuse ein 4-Kanal-Phased-Array zu entwickeln und den Einsatz bei kontrastmittelunterstützten Applikationen zu demonstrieren. Insgesamt wurde gezeigt, dass durch den Einsatz von speziellen, angepassten Kleintierspulen auch Tieruntersuchungen an klinischen MR-Geräten mit niedriger Feldstärke durchführbar sind. Obwohl sich die Bestimmung der Herzfunktion an MR-Geräten im klinischen Alltag zum Goldstandard entwickelt hat, ist die MR-Messung durch lange Atemanhaltezyklen für einen Herzpatienten sehr mühsam. In Kapitel 4 wurde deswegen die Entwicklung einer 32-Kanal-Herzspule beschrieben, welche den Komfort für Patienten deutlich erhöhen kann. Schon mit einem ersten Prototypen für 3T war es möglich, erstmals Echtzeitbildgebung mit leicht reduzierter zeitlicher Auflösung durchzuführen und damit auf das Atemanhalten komplett zu verzichten. Dies ermöglicht den Zugang neuer Patientengruppen, z. B. mit Arrythmien, zu MR-Untersuchungen. Durch eine weitere Optimierung des Designs wurde das SNR sowie das Beschleunigungsvermögen signifikant gesteigert. Bei einem Beschleunigungsfaktor R = 5 in einer Richtung erhält man z. B. gemittelt über das gesamte Herz ein ca. 60 % gesteigertes SNR zu dem Prototypen. Die Kombination dieser Spule zusammen mit neuentwicklelten Methoden wie z. B. Compressed- Sensing stellt es in Aussicht, die Herzfunktion zukünftig in der klinischen Routine in Echtzeit quantifizieren zu können. In Kapitel 5 wurde die Entwicklung einer optimierten Brustspulen für 3T beschrieben. Bei Vorversuchen bei 1,5T wurden Vergleiche zwischen der Standardspule der Firma Siemens Healthcare und einem 16-Kanal-Prototypen durchgeführt. Trotz größerem Spulenvolumen zeigt die Neuentwicklung sowohl hinsichtlich SNR als auch paralleler Bildgebungseigenschaften eine signifikante Verbesserung gegenüber der Standardspule. Durch die Einhaltung aller Kriterien für Medizinprodukte kann diese Spule auch für den klinischen Einsatz verwendet werden. Mit den verbesserten Eigenschaften ist es beispielsweise möglich, bei gleicher Messdauer eine höhere Auflösung zu erreichen. Aufgrund des intrinsischen SNR-Vorteils der 3 T-Spule gegenüber der 1,5 T-Spule ist es dort sogar möglich, bei höheren Beschleunigungsfaktoren klinisch verwertbare Schnittbilder zu erzeugen. Zusammenfassend wurden für alle drei Applikationen NMR-Empfangsspulen entwickelt, die im Vergleich zu den bisher verfügbaren Spulen, hinsichtlich SNR und Beschleunigungsvermögen optimiert sind und dem Anwender neue Möglichkeiten bieten.
This thesis focuses on various aspects and techniques of 19F magnetic resonance (MR). The first chapters provide an overview of the basic physical properties, 19F MR and MR sequences related to this work. Chapter 5 focuses on the application of 19F MR to visualize biological processes in vivo using two different animal models. The dissimilar models underlined the wide applicability of 19F MR in preclinical research. A subsection of Chapter 6 shows the application of compressed sensing (CS) to 19F turbo-spin-echo chemical shift imaging (TSE-CSI), which leads to reduced measurement time. CS, however, can only be successfully applied when a sufficient signal-to-noise ratio (SNR) is available. When the SNR is low, so-called spike artifacts occur with the CS algorithm used in the present work. However, it was shown in an additional subsection that these artifacts can be reduced using a CS-based post processing algorithm. Thus, CS might help overcome limitations with time consuming 19F CSI experiments. Chapter 7 deals with a novel technique to quantify the B+1 profile of an MR coil. It was shown that, using a specific application scheme of off resonant pulses, Bloch-Siegert (BS)-based B+1 mapping can be enabled using a Carr Purcell Meiboom Gill (CPMG)-based TSE sequence. A fast acquisition of the data necessary for B+1 mapping was thus enabled. In the future, the application of BS-CPMG-TSE B+1 mapping to improve quantification using 19F MR could therefore be possible.
Magnetic resonance imaging (MRI) is a medical imaging method that involves no ionizing radiation and can be used non-invasively. Another important - if not the most important - reason for the widespread and increasing use of MRI in clinical practice is its interesting and highly flexible image contrast, especially of biological tissue. The main disadvantages of MRI, compared to other widespread imaging modalities like computed tomography (CT), are long measurement times and the directly resulting high costs. In the first part of this work, a new technique for accelerated MRI parameter mapping using a radial IR TrueFISP sequence is presented. IR TrueFISP is a very fast method for the simultaneous quantification of proton density, the longitudinal relaxation time T1, and the transverse relaxation time T2. Chapter 2 presents speed improvements to the original IR TrueFISP method. Using a radial view-sharing technique, it was possible to obtain a full set of relaxometry data in under 6 s per slice. Furthermore, chapter 3 presents the investigation and correction of two major sources of error of the IR TrueFISP method, namely magnetization transfer and imperfect slice profiles. In the second part of this work, a new MRI thermometry method is presented that can be used in MRI-safety investigations of medical implants, e.g. cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). One of the major safety risks associated with MRI examinations of pacemaker and ICD patients is RF induced heating of the pacing electrodes. The design of MRI-safe (or MRI-conditional) pacing electrodes requires elaborate testing. In a first step, many different electrode shapes, electrode positions and sequence parameters are tested in a gel phantom with its geometry and conductivity matched to a human body. The resulting temperature increase is typically observed using temperature probes that are placed at various positions in the gel phantom. An alternative to this local thermometry approach is to use MRI for the temperature measurement. Chapter 5 describes a new approach for MRI thermometry that allows MRI thermometry during RF heating caused by the MRI sequence itself. Specifically, a proton resonance frequency (PRF) shift MRI thermometry method was combined with an MR heating sequence. The method was validated in a gel phantom, with a copper wire serving as a simple model for a medical implant.
This thesis investigated the potential of Compressed Sensing (CS) applied to Magnetic Resonance Imaging (MRI). CS is a novel image reconstruction method that emerged from the field of information theory. The framework of CS was first published in technical reports in 2004 by Candès and Donoho. Two years later, the theory of CS was published in a conference abstract and two papers. Candès and Donoho proved that it is possible, with overwhelming probability, to reconstruct a noise-free sparse signal from incomplete frequency samples (e.g., Fourier coefficients). Hereby, it is assumed a priori that the desired signal for reconstruction is sparse. A signal is considered “sparse“ when the number of non-zero elements is significantly smaller than the number of all elements. Sparsity is the most important foundation of CS. When an ideal noise-free signal with few non-zero elements is given, it should be understandably possible to obtain the relevant information from fewer Fourier coefficients than dictated by the Nyquist-Shannon criterion. The theory of CS is based on noise-free sparse signals. As soon as noise is introduced, no exact sparsity can be specified since all elements have signal intensities that are non-zero. However, with the addition of little or moderate noise, an approximate sparsity that can be exploited using the CS framework will still be given. The ability to reconstruct noisy undersampled sparse MRI data using CS has been extensively demonstrated. Although most MR datasets are not sparse in image space, they can be efficiently sparsified by a sparsifying transform. In this thesis, the data are either sparse in the image domain, after Discrete Gradient transformation, or after subtraction of a temporally averaged dataset from the data to be reconstructed (dynamic imaging). The aim of this thesis was to identify possible applications of CS to MRI. Two different algorithms were considered for reconstructing the undersampled sparse data with the CS concept. The Nonlinear Conjugate Gradient based technique with a relaxed data consistency constraint as suggested by Lustig et al. is termed Relaxed DC method. An alternative represents the Gradient or Steepest Descent algorithm with strict data consistency and is, therefore, termed the Strict DC method. Chapter 3 presents simulations illustrating which of these two reconstruction algorithms is best suited to recover undersampled sparse MR datasets. The results lead to the decision for the Strict DC method as reconstruction technique in this thesis. After these simulations, different applications and extensions of CS are demonstrated. Chapter 4 shows how CS benefits spectroscopic 19F imaging at 7 T, allowing a significant reduction of measurement times during in vivo experiments. Furthermore, it allows highly resolved spectroscopic 3D imaging in acceptable measurement times for in vivo applications. Chapter 5 introduces an extension of the Strict DC method called CS-CC (CS on Combined Coils), which allows efficient processing of sparse undersampled multi-coil data. It takes advantage of a concept named “Joint Sparsity“, which exploits the fact that all channels of a coil array detect the same sparse object weighted with the coil sensitivity profiles. The practical use of this new algorithm is demonstrated in dynamic radial cardiac imaging. Accurate reconstructions of cardiac motion in free breathing without ECG triggering were obtained for high undersampling factors. An Iterative GRAPPA algorithm is introduced in Chapter 6 that can recover undersampled data from arbitrary (Non-Cartesian) trajectories and works solely in the Cartesian plane. This characteristic makes the proposed Iterative GRAPPA computationally more efficient than SPIRiT. Iterative GRAPPA was developed in a preceding step to combine parallel imaging with CS. Optimal parameters for Iterative GRAPPA (e.g. number of iterations, GRAPPA kernel size) were determined in phantom experiments and verified by retrospectively undersampling and reconstructing a radial cardiac cine dataset. The synergistic combination of the coil-by-coil Strict DC CS method and Iterative GRAPPA called CS-GRAPPA is presented in Chapter 7. CS-GRAPPA allows accurate reconstruction of undersampled data from even higher acceleration factors than each individual method. It is a formulation equivalent to L1-SPIRiT but computationally more efficient. Additionally, a comparison with CS-CC is given. Interestingly, exploiting joint sparsity in CS-CC is slightly more efficient than the proposed CS-GRAPPA, a hybrid of parallel imaging and CS. The last chapter of this thesis concludes the findings presented in this dissertation. Future applications expected to benefit from CS are discussed and possible synergistic combinations with other existing MR methodologies for accelerated imaging are also contemplated.
Diffusionstensorbildgebung im Vergleich zu anderen Parametermethoden für die Infarktcharakterisierung Ziel dieses Teils der Arbeit war die Klärung der Frage, welches Potential verschiedene MR-Parametersequenzen bei der Charakterisierung eines myokardialen Infarkts sowohl im akuten als auch im chronischen Fall haben. Dazu wurde eine Studie mit akut und chronisch infarzierten Rattenherzen durchgeführt. Untersucht wurden die Parameter T1, T2 und T2* sowie die aus der Diffusionstensorbildgebung berechneten Parameter ADC, FA, cs, cp und cl . Es zeigte sich, dass es kein Analogon zum bei einer cerebralen Ischämie bekannten Mismatch-Konzept gibt. Weder im akuten noch im chronischen war Fall eine ausgewiesene Differenz im diagnostizierten Infarktareal zwischen verschiedenen Sequenzen feststellbar. Alles in allem eignen sich zur detaillierten Charakterisierung der Infarktnarbe am besten eine T2*- oder eine Diffusionstensorsequenz. Die T2*-Sequenz liefert optisch das aufschlussreichere Bild, die aufwendigere Diffusionstensorsequenz dagegen bietet aufgrund der vielfachen Darstellungsmöglichkeiten im Postprocessing ein Mehr an Information und zeigt dazu eine Veränderung der Narbe im Zeitverlauf. Oxygenierungsmessung am Mäuseherz in vivo Die Charakterisierung einer Infarktnarbe kann auch über die Darstellung morphologischer Strukturen hinaus erfolgen. Die Oxygenierung ist ein komplexer Parameter, der funktionelle Auskunft über die Vaskularisierung und Viabilität des Gewebes geben kann. Zugang zu diesem Parameter erhält man über T2*-Messungen, da der Parameter T2* sensitiv auf chemisch gebundenen Sauerstoff reagiert. Hier wurden der Einfluss von reiner Sauerstoffatmung im Gegensatz zu normaler Raumluftatmung auf die Oxygenierung bei gesunden und infarzierten Mäusen untersucht. Die Messungen wurden trotz der Schwierigkeiten, die durch die Bewegung durch Atmung und Herzschlag entstehen, in vivo bei 17,6 Tesla implementiert und durchgeführt. Die Auflösung war ausreichend, um auch nach Infarkt extrem ausgedünnte Myokardwände gut auflösen und charakterisieren zu können. Der Effekt auf das Oxygenierungslevel ist stark unterschiedlich zwischen normalen und infarzierten Herzen, woraus auf eine noch nicht weit fortgeschrittene Revaskularisierung der Narbe eine Woche nach Infarzierung geschlossen werden kann. Die Methode wurde darüber hinaus an einem 7,0 Tesla-Magneten zur Verwendung an Ratten implementiert und auf das im Gegensatz zur Maus veränderte Atmungsverhalten der Ratte angepasst. Zum einen kann dadurch der Einfluss des hohen Magnetfeldes auf die Oxygenierungsmessung untersucht werden, zum anderen ist das Herz als zu untersuchendes Objekt bei der Ratte größer. Diffusionswichtung mittels Hole-Burning Die in dieser Arbeit zur Charakterisierung des Herzens verwendete Diffusionsmethode kann im Grenzfall von kurzen T2-Relaxationszeiten an ihre Grenzen stoßen: Bei den verwendeten starken Magnetfeldern klingt das messbare Signal aufgrund der Relaxationszeit T2 oft sehr schnell ab. Daher wurde eine Methode entwickelt, die einen völlig neuen Ansatz zur diffusionsgewichteten Bildgebung verfolgt, bei dem die Informationen über die Diffusion unabhängig von der limitierenden T2-Zeit gewonnen werden können. Die sog. Hole-Burning-Diffusionssequenz verwendet in einem Vorexperiment lediglich die Longitudinalmagnetisierung zur Diffusionswichtung. Das Signal wird dann mit einer schnellen Auslesesequenz akquiriert. Bei der Präparation werden zunächst auf Subvoxel-Niveau Streifen "gebrannt", d.h. die Magnetisierung wird dort gesättigt. Bis zur nächsten Sättigung ist das Verhalten der Magnetisierung abhängig von der T1-Relaxation in diesem Bereich und vom Diffusionsverhalten. Durch rasches Wiederholen des selektiven Pulszugs wird schließlich eine Gleichgewichtsmagnetisierung erreicht, die von der Diffusionskonstanten D und der T1-Relaxationszeit abhängt. Im Rahmen dieser Arbeit wurden die Abhängigkeiten verschiedener Sequenzparameter untersucht und diese mittels Simulationen optimiert. Außerdem wurde die Sequenz an einem Scanner implementiert und erste Experimente damit durchgeführt. Mit Hilfe von Simulationen konnten dazu Lookup-Tabellen generiert werden, mit denen in bestimmten Bereichen (insbesondere bei nicht zu kurzen T1-Relaxationszeiten) sowohl die Diffusionskonstante D als auch die T1-Relaxationszeit quantifiziert werden konnte.
Als Tiermodell ist die Maus aus der pharmazeutischen Grundlagenforschung nicht mehr wegzudenken. Aus diesem Grund nimmt besonders die Verfügbarkeit nicht invasiver Diagnoseverfahren für dieses Tiermodell einen sehr hohen Stellenwert ein. Ziel dieser Arbeit war die Entwicklung von in vivo MR-Untersuchungsmethoden zur Charakterisierung des kardiovaskulären Systems der Maus. Neben der morphologischen Bildgebung wurde ein besonderer Schwerpunkt auf die Quantifizierung funktioneller Parameter der arteriellen Gefäße wie auch des Herzens gelegt. Durch Implementieren einer PC-Cine-Sequenz mit dreidimensionaler Bewegungskodierung war es möglich, die Charakteristik der Bewegung des gesamten Myokards zu untersuchen. Die Aufnahme von Bewegungsvektoren für jeden Bildpunkt und die Bestimmung des Torsionswinkels innerhalb der Messschichten konnte die systolische Kontraktion als dreidimensionale Wringbewegung des Herzens bestätigen. Um die Qualität der morphologischen Gefäßbildgebung zu verbessern, sollte untersucht werden, inwieweit bestehende Verfahren zur Gefäßwanddarstellung optimiert werden können. Implementieren einer Multi-Schicht-Multi-Spin-Echo-Sequenz an einem 17,6 Tesla Spektrometer erlaubte durch das hohe B0-Feld einen deutlichen Signalgewinn. Erstmals wurde es möglich, die gesunde Gefäßwand darzustellen und so morphologische Veränderungen in einem möglichst frühen Zustand zu untersuchen. Neben der Untersuchung morphologischer Veränderungen sollte vor allem ein Schwerpunkt auf das Studium funktioneller Parameter der Gefäßwand gelegt werden. Dazu wurde in einem ersten Schritt mit einem PC-Cine-Verfahren die Umfangsdehnung in ihrem zeitlichen Verlauf ermittelt. Dabei zeigte sich, dass im Laufe einer arteriosklerotischen Plaqueprogression eine Änderung der Umfangsdehnung vor einer Änderung morphologischer Parameter beobachtet werden kann. Deshalb war es Ziel, im Verlauf dieser Arbeit weitere Verfahren zur Charakterisierung funktioneller Parameter des Gefäßsystems zu entwickeln. Um direkt Elastizitätsparameter ermitteln zu können, fehlt als Bezugsgröße der arterielle Pulsdruck (AP). Die Lösung der inkompressiblen Navier-Stokes-Gleichungen unter Anwendung der Lang-Wellen-Näherung und der Näherung für große Pulswellengeschwindigkeiten (PWV) erlaubte die Bestimmung der komplexen Impedanz und somit des arteriellen Pulsdrucks in der Frequenzdomäne. Dadurch war es möglich, den dynamischen Anteil des arteriellen Druckpulses direkt aus einer Messung der Pulswellengeschwindigkeit sowie aus dem Verlauf des Flusspulses zu bestimmen. Zur Ermittlung des AP muss die Pulswellengeschwindigkeit bestimmt werden. Für die MR-Bildgebung in murinen Gefäßen waren hierzu bisher keine Verfahren verfügbar. Da sich die Gefäßdehnung möglicherweise als Indikator für eine frühe Wandveränderung bei der Plaqueprogression zeigt, bestand ein großes Interesse in der Untersuchung von spezifischen gefäßmechanischen Eigenschaften wie beispielsweise der PWV. Im Rahmen dieser Arbeit konnten zwei MR-Methoden für die nicht invasive Bildgebung in der Maus entwickelt werden, die es ermöglichten, die lokale und die regionale Pulswellengeschwindigkeit zu bestimmen. Die Messung der lokalen Pulswellengeschwindigkeit beruht dabei auf der zeitaufgelösten Bestimmung der Gefäßwanddehnung sowie des Blutvolumenflusses. Zur Bestimmung der regionalen Pulswellengeschwindigkeit wurde eine Erweiterung der Zwei-Punkt-Transit-Zeit-Methode verwendet. Durch zeitaufgelöste bewegungskodierte Bildgebung entlang der Aorta konnte anhand von 30 Stützpunkten die Propagation des arteriellen Flusspulses vermessen werden. Die Messzeit gegenüber einer Zwei-Punkt-Methode ließ sich dadurch halbieren. Gleichzeitig bietet die Auswertung von 30 Messpunkten eine größere Sicherheit in der Bestimmung der PWV. Beide Methoden wurden an einem elastischen Gefäßphantom validiert. In vivo Tierstudien an apoE(−/−)-Mäusen und einer Kontrollgruppe zeigten für beide Methoden eine gute Übereinstimmung. Darüber hinaus konnte ein Ansteigen der Pulswellengeschwindigkeit in apoE(−/−)-Mäusen durch arteriosklerotische Veränderungen nachgewiesen werden. Zusammenfassend wurden in dieser Arbeit grundlegende Verfahren zur Untersuchung des kardiovaskulären Systems der Maus optimiert und entwickelt. Die Vielseitigkeit der MR-Bildgebung ermöglichte dabei die Erfassung von morphologischen und funktionellen Parametern. In Kombination können die beschriebenen Methoden als hilfreiche Werkzeuge für die pharmakologische Grundlagenforschung zur Charakterisierung von Herz-Kreislauf-Erkankungen in Mausmodellen eingesetzt werden.
Background Transgenic mouse models are increasingly used to study the pathophysiology of human cardiovascular diseases. The aortic pulse wave velocity (PWV) is an indirect measure for vascular stiffness and a marker for cardiovascular risk. Results This work presents three MR-methods that allow the determination of the PWV in the descending murine aorta by analyzing blood flow waveforms, arterial distension waveforms, and a method that uses the combination of flow and distension waveforms. Systolic flow pulses were recorded with a temporal resolution of 1 ms applying phase velocity encoding. In a first step, the MR methods were validated by pressure waveform measurements on pulsatile elastic vessel phantoms. In a second step, the MR methods were applied to measure PWVs in a group of five eight-month-old apolipoprotein E deficient (ApoE(-/-)) mice and an age matched group of four C57Bl/6J mice. The ApoE(-/-) group had a higher mean PWV than the C57Bl/6J group. Depending on the measurement technique, the differences were or were not statistically significant. Conclusions The findings of this study demonstrate that high field MRI is applicable to non-invasively determine and distinguish PWVs in the arterial system of healthy and diseased groups of mice.
Der Hauptteil der vorliegenden Arbeit befasste sich mit der Anwendung und der Entwicklung von neuen Methoden der spektroskopischen NMR-Bildgebung zur nicht-invasiven metabolischen Charakterisierung von Xenograft-Tumormodellen bei 17,6 T. In einem weiteren Abschnitt wurden verschiedene etablierte Methoden der lokalisierten NMR-Spektroskopie und der spektroskopischen Bildgebung genutzt, um den Metabolismus von Hülsenfrüchten (Pisum sativum) am Hochfeld zu untersuchen. Im experimentellen Teil der Arbeit wurde der selektive Mehrquantenfilter Sel-MQC zur Laktatbestimmung in neun verschiedenen Xenograft-Tumormodellen verwendet. Diese Werte wurden mit Ergebnissen aus der Biolumineszenz und mit der Tumorkontrolldosis 50 (TCD50) der Tumorlinien korreliert. Der Sel-MQC-Editierungsfilter stellte sich als äußerst robuste Methode heraus das Laktat im NMR-Spektrum eindeutig von koresonanten Lipiden des Unterhautfettgewebes bzw. von tumoreigenen Lipiden zu trennen. Der Vergleich mit dem durch die Biolumineszenz bestimmten Laktat zeigte durchweg niedrigere Werte in den NMR-Messungen. Der Hauptgrund für diesen Unterschied besteht wahrscheinlich darin, dass mit der NMR-Methode nur das freie Laktat bestimmt werden kann, wohingegen die Biolumineszenz das gesamte Laktat erfasst. Das mit der NMR detektierbare freie Laktat zeigte allerdings eine mäßige Korrelation zur TCD50 (R = 0,46), wodurch dieser Parameter nur als bedingt prognostisch wertvoll für die Strahlentherapie von Tumoren angesehen werden kann. Der Informationsgehalt pro Messzeit und damit die Effizienz der Standard-Sel-MQC-Editierungssequenz konnte durch verschiedene methodische Erweiterungen gesteigert werden. Eine zusätzliche spektral selektive Wasserunterdrückung und ein weiteres Aufnahmefenster ermöglichte neben der Messung des Laktatsignals die Akquisition sämtlicher Resonanzen des 1H-Spektrums mit einer kurzen Echozeit. Somit konnten zusätzlich das Gesamtcholin und die Methyl- und Metylengruppen der Lipide aufgenommen werden. Neben dem Laktat erwies sich das Verhältnis von Lipid-Methylensignal zu Gesamtcholin (L1/tCho) als aussagekräftigster Parameter, um zwei untersuchte Xenograft-Tumormodelle zu unter-scheiden. Die spektroskopische Sel-MQC-Bildgebungssequenz, deren k-Raumantastung in der Regel mit reiner Phasenkodierung durchgeführt wird, konnte durch eine Verwendung eines Lesegradienten beschleunigt werden. Die bei dem Sel-MQC-Filter auftretenden typischen Artefakte im Bereich der Wasserresonanz sind durch zwei Aufnahmen nach dem Dixon-Prinzip und einem anschließenden Additionsverfahren unterdrückbar. Bei einer ausreichenden Aufnahmezeit, die abhängig vom T2* der zu editierenden Resonanz ist, kann mit der Methode eine nahezu ähnlich hohe Sensitivität wie mit dem rein phasenkodierten Experiment erreicht werden. Eine in die Sequenz eingefügte frequenzselektive Refokussierung der Laktat-CH3-Gruppe ermöglichte die Aufnahme mehrerer Laktatechos ohne eine Phasenmodulation durch die J-Kopplung im Signal zu erhalten. Die nach einer Anregung erhaltenen Echos können zur weiteren Beschleunigung der Sequenz oder zur Bestimmung der apparenten transversalen Relaxationszeit des editieren Metaboliten verwendet werden. Das Grundprinzip des Sel-MQC-Filters konnte in einem umgekehrten Verfahren dazu verwendet werden mobile Lipide im Tumor ohne das koresonante Laktatsignal zu detektieren, um damit die Lipiddetektion zu spezifizieren. Da zur Unterdrückung des Metabolitensignals nur die J-Kopplung ausgenutzt wird, müssen weder Relaxationszeiten noch Diffusionskoeffizienten für die Editierung bekannt sein. Die Aufnahme des Lipidsignals wird dabei in einer Präparation erreicht, was die Sequenz robust gegenüber Bewegungsartefakten macht. Die Methode kann beispielsweise mit Diffusionsgradienten kombiniert werden, um den apparenten Diffusionskoeffizienten mobiler Lipide im Tumorgewebe zu bestimmen. Das hohe Magnetfeld von 17,6 T und damit die vergrößerte chemische Verschiebung eigneten sich insbesonders dazu spektroskopische Messungen an Pflanzensystemen durchzuführen. Im letzten Teil der Arbeit wurden unterschiedliche lokalisierte 1D-, 2D-NMR-Methoden und die spektroskopische Bildgebung verwendet, um den Wildtyp und eine Mutantenform des Pisum sativum nicht-invasiv metabolisch zu untersuchen. Die mit der NMR bestimmten Metabolitenkonzentrationen im Endosperm des Pisum sativum korrelierten mit Resultaten aus biochemischen Auswertungen. Weiterhin konnten mit den NMR-Methoden auch Ergebnisse gewonnen werden, die mit biochemischen und histologischen Verfahren nicht erreicht werden können. Die Untersuchung von Pflanzen – oder wie hier von Pflanzensamen – mit spektroskopischen NMR-Methoden bieten zusätzliche und für bestimmte Fragestellungen auch einzigartige Ansätze deren Metabolismus in vivo zu untersuchen.