Frauenklinik und Poliklinik
Refine
Has Fulltext
- yes (3)
Is part of the Bibliography
- yes (3)
Document Type
- Journal article (2)
- Doctoral Thesis (1)
Keywords
- Brustkompression (1)
- Krebsvorsorge (1)
- Mammographie (1)
- Schmerz (1)
- breast cancer (1)
- breast cancer imaging (1)
- cancer screening (1)
- chemotherapy (1)
- conventional imaging (1)
- cross-sectional imaging (1)
Institute
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (3) (remove)
Purpose
The reliable detection of tumor-infiltrated axillary lymph nodes for breast cancer [BC] patients plays a decisive role in further therapy. We aimed to find out whether cross-sectional imaging techniques could improve sensitivity for pretherapeutic axillary staging in nodal-positive BC patients compared to conventional imaging such as mammography and sonography.
Methods
Data for breast cancer patients with tumor-infiltrated axillary lymph nodes having received surgery between 2014 and 2020 were included in this study.
All examinations (sonography, mammography, computed tomography [CT] and magnetic resonance imaging [MRI]) were interpreted by board-certified specialists in radiology. The sensitivity of different imaging modalities was calculated, and binary logistic regression analyses were performed to detect variables influencing the detection of positive lymph nodes.
Results
All included 382 breast cancer patients had received conventional imaging, while 52.61% of the patients had received cross-sectional imaging.
The sensitivity of the combination of all imaging modalities was 68.89%. The combination of MRI and CT showed 63.83% and the combination of sonography and mammography showed 36.11% sensitivity.
Conclusion
We could demonstrate that cross-sectional imaging can improve the sensitivity of the detection of tumor-infiltrated axillary lymph nodes in breast cancer patients. Only the safe detection of these lymph nodes at the time of diagnosis enables the evaluation of the response to neoadjuvant therapy, thereby allowing access to prognosis and improving new post-neoadjuvant therapies.
Background:
Ketogenic diets (KDs) or short-term fasting are popular trends amongst supportive approaches for cancer patients. Beta-hydroxybutyrate (3-OHB) is the main physiological ketone body, whose concentration can reach plasma levels of 2–6 mM during KDs or fasting. The impact of 3-OHB on the biology of tumor cells described so far is contradictory. Therefore, we investigated the effect of a physiological concentration of 3 mM 3-OHB on metabolism, proliferation, and viability of breast cancer (BC) cells in vitro.
Methods:
Seven different human BC cell lines (BT20, BT474, HBL100, MCF-7, MDA-MB 231, MDA-MB 468, and T47D) were cultured in medium with 5 mM glucose in the presence of 3 mM 3-OHB at mild hypoxia (5% oxygen) or normoxia (21% oxygen). Metabolic profiling was performed by quantification of the turnover of glucose, lactate, and 3-OHB and by Seahorse metabolic flux analysis. Expression of key enzymes of ketolysis as well as the main monocarboxylic acid transporter MCT2 and the glucose-transporter GLUT1 was analyzed by RT-qPCR and Western blotting. The effect of 3-OHB on short- and long-term cell proliferation as well as chemo- and radiosensitivity were also analyzed.
Results:
3-OHB significantly changed the oxygen consumption rate (OCR) and extracellular acidification rate (ECAR) in BT20 cells resulting in a more oxidative energetic phenotype. MCF-7 and MDA-MB 468 cells had increased ECAR only in response to 3-OHB, while the other three cell types remained uninfluenced. All cells expressed MCT2 and GLUT1, thus being able to uptake the metabolites. The consumption of 3-OHB was not strongly linked to mRNA overexpression of key enzymes of ketolysis and did not correlate with lactate production and glucose consumption. Neither 3-OHB nor acetoacetate did interfere with proliferation. Further, 3-OHB incubation did not modify the response of the tested BC cell lines to chemotherapy or radiation.
Conclusions:
We found that a physiological level of 3-OHB can change the energetic profile of some BC cell lines. However, 3-OHB failed to influence different biologic processes in these cells, e.g., cell proliferation and the response to common breast cancer chemotherapy and radiotherapy. Thus, we have no evidence that 3-OHB generally influences the biology of breast cancer cells in vitro.
Studien der letzten Jahre haben gezeigt, dass viele Frauen aufgrund von Schmerzen bzw. aufgrund der Angst vor Schmerzen während der Mammographie diese Kebsvorsorgeuntersuchung nicht wahrnahmen. Die vorliegende Arbeit sollte folgende Fragen klären: Empfinden Frauen bei der Brustkompression während der Mammographie weniger Schmerzen wenn sie ihre Brüste selbst komprimieren, als bei Kompression durch eine MTA? Sind Frauen nach Eigenkompression zufriedener mit der gesamten Mammographie, als Frauen mit Fremdkompression, und inwieweit wirkt sich diese Zufriedenheit auf die Bereitschaft aus, wieder eine Mammographie durchführen zu lassen? Durch diese Studie sollte ein neuer Wege aufgezeigt werden, Frauen die Mammographie so angenehm wie möglich zu gestalten, um dadurch positiven Einfluss auf ihr Verhalten dieser wichtigen Vorsorgeuntersuchung gegenüber nehmen zu können. Untersucht wurden 200 Patientinnen, die der radiologischen Abteilung der Frauenklinik der Universität Würzburg zur Durchführung einer Mammographie zugewiesen worden waren. Es erfolgte die Erhebung der generellen und situativen Ängstlichkeit mittels State-Trait-Angstinventar (STAI), sowie der individuellen Kontrollüberzeugungen mittels Fragebogen zur Erhebung von Kontrollüberzeugungen zu Krankheit und Gesundheit (KKG). Nach der Mammographie beantworteten die Frauen nochmals einen Fragebogen, der ihre Zufriedenheit mit der Mammographie, sowie die dabei empfundenen Schmerzen und die Bereitschaft in zwei Jahren wieder an einem Screening durch Mammographie teilzunehmen, erfasste. Die Ergebnisse der Arbeit lassen sich folgender Maßen zusammenfassen: Es zeigte sich eine Korrelation zwischen der situativen Ängstlichkeit und den bei der Untersuchung empfundenen Schmerzen. Außerdem zeigte sich, je geringer die situationsgebundene Angst der Frauen war, desto zufriedener waren sie auch mit der Untersuchung. Es konnte kein Zusammenhang zwischen der Kontrollüberzeugung und der Zufriedenheit mit der Mammographie nachweisen werden, weder bei Fremdkompression, noch bei Eigenkompression. Auch mit dem bei der Kompression empfundenen Schmerz konnte bei keiner Kontrollüberzeugung ein Zusammenhang hergestellt werden. Bezüglich der Kompression selbst wurde festgestellt, dass Patientinnen der Experimentalgruppe bei der Kompression mehr Kraft anwandten als Patientinnen der Kontrollgruppe und damit ihre Brüste flacher komprimierten. Die Mehrheit beider Gruppen war mit der Mammographie zufrieden und gaben an, wieder an einer Mammographie in zwei Jahren teilnehmen zu wollen. Allerdings waren Frauen, die ihre Brüste selber komprimierten generell zufriedener mit ihrer Untersuchung und empfanden weniger Schmerzen während der Kompression. Der Zusammenhang, dass Frauen eine erneute Teilnahme an einer Mammographie als umso wahrscheinlicher ansahen, je zufriedener sie mit der aktuellen Untersuchung waren, konnte ebenfalls bestätigt werden.