543 Analytische Chemie
Refine
Has Fulltext
- yes (19)
Is part of the Bibliography
- yes (19)
Year of publication
Document Type
- Doctoral Thesis (17)
- Journal article (2)
Keywords
- HPLC (7)
- Charged Aerosol Detection (4)
- Chemische Reinheit (4)
- Instrumentelle Analytik (4)
- Impurity Profiling (3)
- Pharmaceutical Analysis (3)
- Aminosäuren (2)
- Chromatographie (2)
- Malaria (2)
- Reinheitsanalytik (2)
Institute
- Institut für Pharmazie und Lebensmittelchemie (13)
- Institut für Funktionsmaterialien und Biofabrikation (2)
- Graduate School of Life Sciences (1)
- Institut für Anorganische Chemie (1)
- Institut für Organische Chemie (1)
- Lehrstuhl für Tissue Engineering und Regenerative Medizin (1)
- Medizinische Klinik und Poliklinik I (1)
Sonstige beteiligte Institutionen
In the first part of his work, the causes for the sudden degradation of useable capacity of lithium-ion cells have been studied by means of complementary methods such as computed tomography, Post-Mortem studies and electrochemical analyses. The results obtained point unanimously to heterogeneous aging as a key-factor for the sudden degradation of cell capacity, which in turn is triggered by differences in local compression.
At high states of health, the capacity fade rate is moderate but some areas of the graphite electrode degrade faster than others. Still, the localized changes are hardly noticeable on cell level due to averaging effects. Lithium plating occurs first in unevenly compressed areas, creating patterns visible to the human eye. As lithium plating leads to rapid consumption of active lithium, a sudden drop in capacity is observed on cell level. Lithium plating appears to spread out from the initial areas over the whole graphite electrode, quickly consuming the remaining useful lithium and active graphite. It can be hypothesized that a self-amplifying circle of reciprocal acceleration of local lithium loss and material loss causes rapid local degradation.
Battery cell designers can improve cycle life by homogeneous pressure distribution in the cell and using negative active materials that are resilient to elevated discharge potentials such as improved carbons or lithium titanate. Also, a sufficiently oversized negative electrode and suitable electrolyte additives can help to avoid lithium plating. When packs are designed, care must be taken not to exert local pressure on parts of cells and to avoid both very high and low states of charge.
In the second part of this dissertation the resilience of cylindrical and pouchbag cells to shocks and different vibrations was investigated. Stresses inflicted by vibration and shock tests according to the widely recognized UN38.3 transport test were compared to a long-time test that exposed cells to a 186 days long ordeal of sine sweep vibrations with a profile based on real-world applications. All cells passed visual and electric inspection performed by TU München after the vibration tests. Only cylindrical cells subjected to long-term vibrations in axial direction showed an increase in impedance and a loss of capacity that could be recuperated in part.
The detailed analyses presented in this thesis gave more details on the damages inflicted by vibrations and shocks and revealed drastic damages in some cases. In cylindrical cells, only movement in axial direction caused damage. Long term vibrations were found to be especially detrimental.
No damage whatsoever could be detected for pouch cells, regardless of the test protocol and the direction of movement. The extreme resilience of pouchbag cells shows that the electrode stack of lithium-ion cells is resistant to vibrations, and that damages are caused by design imperfections that can be improved at low cost.
The findings of this work, and the general state of research show that it is most crucial to control the lithiation and thus potential of the graphite electrode.
In the last part of this work, a new, direct method for charge estimation based on changing transmission is presented. A correlation between transmission of short ultrasonic pulses and state of charge is found. This new technology allows direct measurement of the state of charge. The method is demonstrated for batteries with different positive active materials, showing its versatility. As the observed changes can be traced to the lithiation of graphite, it can be determined without a reference electrode. Already at this early stage of development, the found correlations allow estimation of state of charge. The present hysteresis in the signal height of the slow wave, which is unneglectable especially during discharging at higher currents, will be subject to further investigation.
The observed effects can be explained by effects on different length scales. Biot’s theory explains the second wave’s slowness based on the active material particles size in the range of 0.01 mm and electrolyte-filled pores. Lithiation of graphite changes the porosity of the electrode and thereby the velocity and wavelength of the impulse. When the wavelength approaches the length scale of the layers, 0.1 mm, scattering effects dampen the transmitted signal. Finally, the wavelength of the pulse should be shorter than the transducers diameter to obtain a homogeneous wave front.
To conclude, the new method allows the control of each individual cell in a pack independent from the electrical connections of the cells.
As the method shows great promise, further studies regarding factors such as long-term behavior, temperature and current rates should be conducted. In this thesis hysteresis was observed and a deeper understanding of the reasons behind it may allow further improvements of measurement precision.
The requirements for the impurity profiling of substances for pharmaceutical use have become greater over time. They can be accomplished by the use of modern instrumental analysis techniques, which have been evolved in the last decades. New types of columns with HILIC, mixed-mode and chiral stationary phases are suitable for the separation of all kinds of substances mixtures, that were previously hardly possible with the use of common reversed phase columns. Modern, almost universal detectors like CAD, ELSD and CNLSD can be applied for a sensitive detection of substances without a chromophore. However, in addition to some small individual disadvantages to these methods, the costs are high and applications are still kind of rare. Thus, the introduction of these devices at a broader level has not yet taken place. While this presumably will change over time, there is a need for methods that enable the impurity profiling of challenging substances with widespread analytics devices.
Methionine is a substance with hydrophobic and hydrophilic impurities. With the help of a mixed-mode stationary phase, which is a combination of a reversed phase and a strong cationic exchanger, the separation of all putative impurities was found possible with good sensitivity and selectivity. The method requires apart from the column only standard isocratic HPLC equipment and was successfully validated.
The evaluation of the enantiomeric purity of amino acids is challenging. Two approaches were made. The first method utilizes CE by means of in-capillary derivation with OPA and the subsequent separation with a cyclodextrin. With the use of OPA/NAC and γ-cyclodextrin, a simple and cost-effective method for the indirect enantioseparation of 16 amino acids was developed. With the second approach, racemic amino acids can be analyzed with HPLC and in-needle derivatization. For this, different columns and chiral thiols were evaluated and the chromatographic parameters were optimized. A method with OPA/NIBLC, a pentafluorophenyl column made the enantioseparation of 17 amino acids feasible. A LOQ of the minor enantiomer down to 0.04 % can be achieved with UV spectrophotometric detection. A similar method was developed for impurity profiling of L-amino acids. This can be used alternatively for the amino acid analysis performed by the European Pharmacopoeia.
A simple, robust, precise and accurate method for the evaluation of impurities in glyceryl trinitrate solution was developed and validated. The four impurities of glyceryl trinitrate are separated by means of an acetonitrile-water gradient and the assay for this substance is also possible.
The Corona® charged aerosol detector (CAD) is an aerosol-based detector first de-scribed by Dixon and Peterson in 2002. It is capable of detecting compounds inde-pendent from their physico-chemical properties presumed the analyte is sufficiently non-volatile. Consequently, the CAD is often applied to the analysis of substances that do not possess a suitable UV chromophore. Major drawbacks are however, the detector signal is non-linear and depending on the content of organic solvent in the mobile phase.
This thesis tried to explore possible applications of the CAD for pharmaceutical analysis. Therefore, several substances from different compound classes were in-vestigated. Newly developed or existing methods were validated. Thus the perfor-mance of the CAD could be examined. Both assay and impurity determination were evaluated for their compliance with ICH Q2(R1) “Validation of Analytical Proce-dures” and the “Technical Guide for the Elaboration of Monographs”.
In the course of the establishment of reference substances at the EDQM, a generic screening method for the identification of organic and inorganic pharmaceutical counterions was needed. An HPLC-CAD method developed by Zhang et al. was therefore investigated for its suitability for pharmacopoeial purpose. Method valida-tion was performed. It was found that 23 ions could be separated and detected. Iden-tification was achieved via retention time of an authentic standard of the corre-sponding ions. Alternatively, peak assignment was performed by determination of the exact mass using TOF-MS. Ions could be quantified as impurities or for stoichi-ometric purpose.
For the impurity control in topiramate, the performance characterstics of the CAD were compared to that of an ELSD. CAD was superior to ELSD in terms of repeata-bility, sensitivity and linearity. However, impurities could be quantified with satisfac-tory accuracy with both detectors. The application of the ELSD was not feasible due to non-reproducible spike peaks eluting after the principle peak in the chromatogram of the test solution. One of the impurities, topiramate impurity A (diacetonide), gave no or a vastly diminished signal in the ELSD and the CAD, respectively. It is evapo-rated during the detection process due to its relatively high vapor pressure. The re-sponse could be enhanced by a factor of nine via post-column addition of acetoni-trile and a lower nebulizer temperature. As the response of topiramate impurity A was still about thousand-fold lower than the response of all other impurities, its quantification was not feasible. Additionally, the HPLC-CAD was successfully vali-dated as an assay procedure for topiramate.
There seems to be a great potential in the application of the CAD to the analysis of excipients as most compounds do not possess a suitable UV chromophore. Here, a simple and rapid HPLC-CAD method for the determination of polidocanol (PD) was developed. The method was successfully validated as a potential assay procedure for the Ph. Eur. as none is described in either of the two PD monographs. The same method was applied to the determination of the PD release from a pharmaceutical polymer matrix.
A method for the determination of the fatty acid (FA) composition of polysorbate 80 (PS80) was developed and validated. Using the CAD and mass spectrometry, we were able to identify two new FAs in 16 batches from four manufacturers. All batch-es complied with pharmacopoeial specification. Furthermore, the overall composi-tion of the different PS80 species (“fingerprinting”) and the peroxide content were determined. In addition to the chemical characterization, functionality related charac-teristics (FRCs) were determined. Correlations between chemical composition and FRCs were found.
The validation data of the above mentioned methods suggests that the CAD repre-sents a viable detection technique for pharmaceutical analysis. The CAD was suffi-ciently sensitive for non-volatile analytes. Impurity control down to concentrations of 0.05 or 0.03%, as demanded by ICH Q3A (R2), is achievable. However, the response of semi-volatile compounds may be drastically diminished. It could be confirmed that the response of the CAD is linear when the range does not exceed two orders of magnitude. Exceptions may be observed depending on the actual method setup. When the measuring range is sufficiently narrow, quantification can be done using single-point calibration which is common practice in pharmaceutical anlysis. Impuri-ties may also be quantified against a single calibration solution. However, correction factors may be needed and the accuracy is considerably lower compared to an as-say method. If a compound is to be quantified over a large concentration range, log-log transformation of the calibration curve is needed and a decreased accuracy has to be accepted.
Glucocorticoide werden in der Herzschrittmachertherapie eingesetzt, um einen Anstieg der Reizschwelle nach der Implantation des Schrittmachers zu verringern und dauerhaft auf niedrigerem Niveau zu halten, als dies ohne Glucocorticoid-Behandlung der Fall wäre. Die Applikation der zu diesem Zweck eingesetzten Glucocorticoide Dexamethasonacetat (DXA) und Dexamethasonphosphat, in seltenen Fällen auch Beclomethasondipropionat (BDP), erfolgt dabei in der Regel mittels einem an der Elektrodenspitze angebrachten Matrixsystem, das für eine langsame lokale Freisetzung der Arzneistoffe an der Grenzfläche zwischen kathodischem Elektrodenkontakt und Herzgewebe sorgen soll. Diese Anwendungsform ist speziell, da trotz einer systemischen Freisetzung der Substanzen eine lokale Wirkung erzielt werden soll, welche die Funktion des Schrittmachers als Medizinprodukt unterstützen soll – aus pharmakokinetischer Sicht ein wichtiger Unterschied zu den üblichen topischen Glucocorticoid Anwendungen. Unter physiologischen Bedingungen wurde diese Applikationsform hinsichtlich der Arzneistofffreisetzung und anschließender Umverteilung mit Bindung der Glucocorticoide an das kardiale Gewebe bislang ebenso wenig untersucht, wie verschiedene Glucocorticoide in dieser Anwendung hinsichtlich ihrer Pharmakokinetik verglichen wurden. In der vorliegenden Arbeit wurden deshalb die pharmakokinetischen Vorgänge der drei Glucocorticoide DXA, BDP und des potentiell einsetzbaren Glucocorticoids GCX (dessen Identität aus patentgründen derzeit nicht offengelegt werden kann) untersucht. Die Freisetzungssysteme enthielten, je nach Glucocorticoid, Arzneistoffdosen im Bereich von etwa 150 bis 260 µg. In einem in-vitro Freisetzungsmodell in Methanol wurde zunächst bestätigt, dass sich die Freisetzungskinetik der untersuchten Matrizes gemäß den Modellvorstellung zu einem dünnwandigen monolithischen Freisetzungssystem nach dem Quadratwurzelgesetz beschreiben ließ. DXA wurde mit einer Freisetzungsrate von 55,6 ± 1,9 µg/h1/2 in 24 Stunden annähernd vollständig freigesetzt, während die Rate für BDP bei 21,8 ± 0,7 µg/h1/2 lag und nur für eine Freisetzung von etwa zwei Dritteln des Gesamtgehalts der Freisetzungsmatrix sorgte. GCX wurde gar mit nur 4,2 ± <0,1 µg/h1/2 freigesetzt. Die ermittelten Freisetzungsraten (DXA > BDP >>> GCX) waren überraschenderweise nicht konsistent mit den logP-Werten der Substanzen. Dies wies darauf hin, dass nicht alleine die unterschiedlichen physikochemischen Eigenschaften der Substanzen zu den differierenden Freisetzungsprofile führten, sondern wohl auch die Formulierung der Silikonmatrix einen starken Einfluss ausübte – eine wichtige Erkenntnis für die Weiterentwicklung derartiger Glucocorticoid haltiger Matrixfreisetzungssysteme. Vor allem während der bis zu 4 wöchigen Phase unmittelbar nach der Elektrodenimplantation ist die Matrix dem Blutstrom ausgesetzt, bevor sich als Reaktion des Organismus auf den implantierten Fremdkörper eine fibröse Hülle um die Elektrodenspitze bildet. Zur Annäherung an die physiologischen Freisetzungsverhältnisse in dieser initialen Phase, in nach dem Quadratwurzelgesetz die mengenmäßig stärkste Glucocorticoid-Freisetzung erfolgen sollte, wurden deshalb erstmals Freisetzungsversuche in Humanplasma über 28 Tage durchgeführt. Mit einer Freisetzungsrate von 2,26 ± 0,08 µg/h1/2 wurde hier eine unerwartet starke Freisetzung von BDP beobachtet, wohingegen diese für DXA und GCX mit Raten von 0,39 ± 0,03 µg/h1/2 und 0,42 ± 0,01 µg/h1/2 deutlich langsamer ausfiel und sich kaum voneinander unterschied. Die Reihenfolge der Freisetzungsgeschwindigkeiten (BDP >>> GCX = DXA) unterschied sich somit unter physiologischen Bedingungen gänzlich von den in-vitro Bedingungen. Womöglich kamen im wässrigen Freisetzungsmedium Humanplasma dabei die Formulierungseinflüsse verstärkt zum Tragen, die sich bereits unter den in-vitro Bedingungen andeutenden. Ein zusätzlicher Einfluss mochte von der Bildung des 9,11 Epoxy Belcomethasons als Abbauprodukt des BDP ausgegangen sein, welches unter den physiologisch angenäherten Bedingungen in hohem Ausmaß entstand. Dies führte zu einer Stabilitätsuntersuchung von Beclomethason in Humanplasma und verschiedenen Puffersystemen, bei welcher sich ein stabilitätsmindernder Einfluss von Carbonat-Puffersystemen herausstellte. Im Zuge der Freisetzungsversuche in Humanplasma wurde zudem erstmals die Entstehung von 17 Oxo Dexamethason als Abbauprodukt von DXA beobachtet und durch Nachsynthese bestätigt. Für die Phase der Herzschrittmachertherapie, in der an der Grenzfläche zwischen Elektrode und Herzgewebe eine lokale und akute Entzündung infolge der Implantation der Schrittmacherelektrode auftritt und üblicherweise ein starker Anstieg der Reizschwelle zu beobachten ist, lieferten die Versuche in Humanplasma somit erstmals Daten zur Freisetzung verschiedener Glucocorticoide unter Einbezug angenäherter physiologischer Verhältnisse. Für die korrekte Durchführung der Freisetzungsversuche ist das Vorliegen von Sink Bedingungen essentiell. Da die praktische Löslichkeit von Glucocorticoiden in Humanplasma bislang nicht bekannt war, wurde die Aufnahmekapazität des Humanplasmas (Kombination aus Löslichkeit und Plasmaproteinbindung) für DXA, GCX und BDP untersucht. Sink Bedingungen konnten für alle Substanzen sichergestellt werden, wobei gegenüber der reinen Wasserlöslichkeit eine deutlich höhere Aufnahmekapazität gezeigt werden konnte und den hohen Einfluss der Proteinbindung hervorhob. Um die insgesamt herrschenden physiologischen Verhältnisse noch besser zu beschreiben und dabei die Umverteilung der Arzneistoffe nach Freisetzung aus dem Implantat an das Zielgewebe zu untersuchen, wurde ein neuartiges ex-vivo Modell entwickelt. Dies erlaubte eine Simulation der Arzneistofffreisetzung aus dem Implantat in Gegenwart eines Gewebekompartiments und berücksichtigte eine flussartige Konvektion des Mediums. Mit diesem Modell wurden Verhältnisse der AUCs der Glucocorticoide zwischen Gewebe und Humanplasma ermittelt, die mit Werten von 3,4 für DXA, 3,8 für BDP und 2,5 für GCX auf eine ausgeprägte Umverteilung aus dem Humanplasma in das Gewebe hinwiesen. Insgesamt schien damit aufgrund der raschen Freisetzung und Diffusion in das Gewebe eine Verwendung von BDP zur Bekämpfung einer lokalen akuten Entzündung unmittelbar nach der Implantation aus pharmakokinetischer Sicht vorteilhaft. Mit Blick auf einen jahrelangen Effekt konnte jedoch auch die langsame Freisetzung von DXA und GCX mit deren sehr stabilen Wirkformen als vorteilhaft diskutiert werden. Die Versuche können letztlich bei der Auswahl eines möglichst idealen Glucocorticoids für die Herzschrittmachertherapie behilflich sein und bieten erstmals ein weitestgehend physiologisches Untersuchungsmodell für diese Applikationsform. Inwiefern sich die unterschiedliche Pharmakokinetik der drei Glucocorticoide auch in pharmakodynamischer Sicht auswirken könnte, sollte schließlich im Zellkulturmodell untersucht werden. Zuvor wurde jedoch in-vitro getestet, ob sich der elektrische Schrittmacherimpuls selbst als Entzündungsreiz bemerkbar machen und damit einen Hinweis auf eine dadurch hervorgerufene dauerhafte Entzündung des Herzgewebes geben würde. Dazu wurde eigens ein Modell entworfen, das die Applikation des elektrischen Stimulus in einem Zellkulturansatz zuließ. Die Messung der Entzündungsmarker IL-6, IL-8, MMP-9 und MCP-1 ließ keine entzündliche Reizung der Zellen durch einen Schrittmacherimpuls in Höhe von 1 V und 0,5 ms Dauer erkennen. Anschließend wurde untersucht, ob sich die selbst ermittelten pharmakokinetischen Unterschiede der drei Glucocorticoide in der akuten Entzündungsphase nach Elektrodenimplantation in-vitro in unterscheidbaren biologischen Aktivitäten auswirken würden. Signifikante Unterschiede in der Inhibition der Sekretion der Entzündungsmarker IL-6 und MMP 9 konnten allerdings trotz der unterschiedlichen freigesetzten Dosen an DXA, GCX und BDP nicht beobachtet werden. Somit erwies sich keine der drei Substanzen, trotz unterschiedlicher pharmakokinetischer Voraussetzungen und Affinitäten zum Glucocorticoid-Rezeptor, als überlegen. In einem ersten Ausblick ließ dies für die klinische Anwendung von GCX und BDP – zumindest in der initialen Phase nach Elektrodenimplantation – einen zu DXA vergleichbaren Einfluss auf die Reizschwelle vermuten. Neben einer antiinflammatorischen Wirkung wird auch eine Minderung des Reizschwellenanstieges durch eine bei Glucocorticoid Exposition nur dünn ausgeprägte fibröse Kapsel an der Elektrodenspitze diskutiert. Als Beitrag zur Untersuchung der in der klinischen Praxis beobachteten Wirkung des DXA wurde daher abschließend geprüft, ob die freigesetzten Glucocorticoid Dosen zu einer Proliferationshemmung von Endothelzellen und Fibroblasten führen konnten. Ein vermindertes Wachstum der Zelllinien EA.hy926 und IMR-90 unter den freigesetzten Glucocorticoid Dosen konnte jedoch nicht beobachtet werden. Künftige Untersuchungen des Einflusses der Glucocorticoide auf die Synthese einzelner Bindegewebsbestandteile wie Kollagen könnten hierzu womöglich weitere Erkenntnisse liefern. In der vorliegenden Arbeit wurde erstmals erfolgreich die Pharmakokinetik dreier Glucocorticoide im Kontext der Herzschrittmachertherapie unter physiologischen Verhältnissen beschrieben und ein neuartiges ex-vivo Modell entwickelt, das zukünftig ein hilfreiches Werkzeug zur Untersuchung der Pharmakokinetik von kardiovaskulären Implantaten sein kann. Darauf aufbauend wurde zudem erstmalig die Pharmakodynamik dieser Glucocorticoide in der Herzschrittmachertherapie verglichen und begonnen, den Glucocorticoid Effekt in der Herzschrittmachertherapie näher zu beleuchten.
Development and validation of LC-MS/MS methods to determine PK/PD parameters of anti-infectives
(2014)
In the present thesis the development and validation of bioanalytical LC-MS/MS methods for the quantification of erythromycin A, erythromycin ethylsuccinate, roxithromycin, clarithromycin, 14 hydroxy clarithromycin, flucloxacillin, piperacillin and moxifloxacin in human plasma and human urine (piperacillin) is introduced. All methods were applied to analyze human plasma and urine samples from clinical trials and therefore, have been validated according to international guidelines. The methods were reliable in these studies and fulfilled all regulatory requirements known at the time of the study conduct.
Moreover, the validation data of the macrolides were compared on three different mass spectrometers (API III Plus, API 3000™, API 5000™). The new innovations in the ion source (horizontal versus vertical electrospray), the ionpath (skimmer, QJet) and the diameter of the orifice resulted in better sensitivity and a larger linearity range for the majority of the analytes. Sensitivity was improved up to a factor of 12 (for clarithromycin) between API III Plus to API 3000™ and up to a factor of 8 (for erythromycin and roxithromycin) between API 3000™ and API 5000™, keeping the accuracy and precision data at about the same level. The high sensitivity was a benefit for example for the flucloxacillin study, because concentrations from all subject samples were detectable up to approximately eight half-lives, i.e. no concentrations needed to be reported below the quantification limit. Also the linearity range were extended from two orders of magnitude to up to four orders of magnitude, which increases the likelihood to allow to analyze all samples from a pharmacokinetic study in the same run.
This is especially useful if a large concentration range needs to be analysed, for example, if the method shall be applied in an ascending dose study. Then, all low concentrations from the beginning of the study can be determined, as well as all high concentrations, without the need to dilute and analyse single samples repeatedly.
The pharmacokinetic data were compared to previously reported literature data and correlated graphically with MIC values of popular microorganisms which might be a starting point for further PK/PD investigations.
The PK/PD theory is a very helpful tool for prediction of the efficacy of given drugs against certain micro-organisms. Depending on the pharmacodynamic processes, e. g. the mode of action, three classes of drugs have been identified.
In the same way this applies to adverse effects, which need to be minimised by reducing plasma concentrations. These coherences are not well-investigated, yet, and are not discussed further in this thesis.
Still, a lot of research has to be done in this interdisciplinary field to minimise uncertainty in single values, like an AUC/MIC. These include:
Improve accuracy and precision of bioanalytical methods determining total and free concentration data in biological matrices for calculation of AUC and Cmax
These parameters are related to the MIC in pharmacodynamic considerations. Since the determination of the MIC often underlies significant variations and also differences between microbiological laboratories, the determination of concentrations of anti-infectives is particular important, being achievable by scientific exact techniques. Finally, from the volume of distribution of antibiotics can be used to derive information about intracellular concentrations and effectivity of antiinfectives.
Non-contact, Label-free Monitoring of Cells and Extracellular Matrix using Raman Spectroscopy
(2012)
Non-destructive, non-contact and label-free technologies to monitor cell and tissue cultures are needed in the field of biomedical research.1-5 However, currently available routine methods require processing steps and alter sample integrity. Raman spectroscopy is a fast method that enables the measurement of biological samples without the need for further processing steps. This laser-based technology detects the inelastic scattering of monochromatic light.6 As every chemical vibration is assigned to a specific Raman band (wavenumber in cm-1), each biological sample features a typical spectral pattern due to their inherent biochemical composition.7-9 Within Raman spectra, the peak intensities correlate with the amount of the present molecular bonds.1 Similarities and differences of the spectral data sets can be detected by employing a multivariate analysis (e.g. principal component analysis (PCA)).10
Here, we perform Raman spectroscopy of living cells and native tissues. Cells are either seeded on glass bottom dishes or kept in suspension under normal cell culture conditions (37 °C, 5% CO2) before measurement. Native tissues are dissected and stored in phosphate buffered saline (PBS) at 4 °C prior measurements. Depending on our experimental set up, we then either focused on the cell nucleus or extracellular matrix (ECM) proteins such as elastin and collagen. For all studies, a minimum of 30 cells or 30 random points of interest within the ECM are measured. Data processing steps included background subtraction and normalization.
Im Rahmen dieser Arbeit wurden sehr einfache, flüssigchromatographische Methoden zur Qualitätsanalytik gebräuchlicher Antimalaria-Medikamente (Amodiaquin, Mefloquin, Proguanil sowie die Kombination Artemether/Lumefantrin) entwickelt, die nur wenige, günstig erhältliche Chemikalien (Phosphatpuffer, Methanol) sowie gewöhnliche, kommerzielle RP-18-Säulen benötigen. Sie sind insbesondere zur Anwendung in Laboratorien in Entwicklungsländern geeignet und erfordern keine komplexen HPLC-Instrumente wie beispielsweise Gradientenpumpen oder Säulenthermostate. Der Verzicht auf Ionenpaarreagenzien ermöglicht es, dass eine stationäre Phase für mehr als nur einen einzigen Einsatzzweck verwendet werden kann und dass langwierige Äquilibrier- bzw. Spülschritte nicht notwendig sind. Alle Methoden arbeiten im isokratischen Elutionsmodus und durch die Verwendung kurzer Säulen (125 mm) konnten die jeweiligen Analysenzeiten zusätzlich verringert werden. Hierdurch ist zudem eine Reduzierung des Fließmittelverbrauches möglich.
Während der Methodenentwicklung wurden charakteristische, aus dem Herstellungsweg des jeweiligen Arzneistoffes stammende potentielle Verunreinigungen berücksichtigt. Ihre Bestimmung erlaubt eine Aussage über die Herkunft eines Wirkstoffes bzw. eines Arzneimittels, da das Verunreinigungsmuster einer Substanz oftmals die Zuordnung zu einem bestimmten Herstellungs- bzw. Reinigungsprozess ermöglicht.
Alle Methoden wurden hinsichtlich der Linearität innerhalb des Arbeitsbereiches sowie der Wiederholpräzision charakterisiert. Es wurde eine gute Reproduzierbarkeit gefunden. Die Nachweis- und Bestimmungsgrenzen der untersuchten Verunreinigungen lagen bei einem Level von je 0.1 %. Durch gezielte Variation wurde der Einfluss wechselnder Trenntemperaturen sowie schwankender pH-Werte der jeweiligen mobilen Phase und die hieraus resultierenden Effekte untersucht. Hierbei zeigte sich, dass die Methoden sehr robust gegenüber diesen Einflussgrößen sind und somit für die Anwendung mit einfach ausgestatteten HPLC-Systemen sowie besonders für den Einsatz in tropische Gebieten mit wechselnden klimatischen Bedingungen gut geeignet sind.
Flüssigchromatographische Methoden spielen heute in der pharmazeutischen Analytik vor allem zur Bestimmung der Reinheit eines Arzneistoffes eine herausragende Rolle und sind in nahezu jeder Monographie der wichtigsten Arzneibücher (z. B. im Ph. Eur.) zu finden. Einfach durch-führbare Untersuchungsmethoden, wie beispielsweise die im GPHF-Minilab® angewandte Dünnschichtchromatographie, erfordern im Vergleich zur HPLC weniger komplexe und teure Instrumente und können selbst in entlegenen Gebieten ohne Laboratorium durchführt werden. Sie verfügen allerdings über eine nur sehr geringe Genauigkeit und Reproduzierbarkeit, da sowohl die praktische Durchführung als auch die anschließende Auswertung rein manuell bzw. visuell erfolgt und somit in hohem Maße einer Beeinflussung durch den jeweiligen Analytiker unterworfen ist. Die entwickelten HPLC-Methoden wurden mit dünnschichtchromatographischen Verfahren verglichen, hierbei besonders unter dem Aspekt der visuellen und der instrumentellen Auswertung der Chromatogramme zur Bestimmung des Gehaltes einer unbekannten Probe. Hierbei konnte aufgezeigt werden, dass die Dünnschichtchromatographie der Flüssigchromatographie eindeutig unterlegen ist, insbesondere wenn die Auswertung nicht mittels eines entsprechenden Scanners sondern rein visuell erfolgt: Nur in den wenigsten Fällen ist es möglich, eine annähernd präzise Aussage über den Gehalt zu treffen und zudem ist die Bestimmung der Verwandten Substanzen nur sehr bedingt möglich. Durch den Einsatz von Auftragegeräten bzw. Plattenscannern kann die Genauigkeit zwar signifikant erhöht werden, allerdings sind solche Instrumente im Verhältnis wesentlich teurer als einfache, modulare HPLC-Systeme und zählen heute in den wenigsten Laboratorien zum Standardinventar.
Vereinfachte chromatographische Methoden können ein wichtiges Hilfsmittel für Kontrolllaboratorien in Entwicklungsländern sein, wenn komplexe, etablierte Protokolle nur eingeschränkt angewendet werden können. Durch die Kombination aus dünnschichtchromatographischer Basisanalytik und einer flächendeckenden Untersuchung mittels HPLC lässt sich die Arzneimittelqualität sehr gut überprüfen, die regulatorischen Organe eines Landes entsprechend zu entlasten und die Versorgung der Bevölkerung mit qualitativ einwandfreien Medikamenten zu gewährleisten.
Ein weiterer Teil der Arbeit befasst sich mit der Stabilitätsanalytik individuell hergestellter, Noradrenalin-haltiger Injektionslösungen. Solche Rezepturen werden oftmals in Krankenhausapotheken im Rahmen der Defektur auf Vorrat durch Verdünnen der entsprechenden kommerzieller Fertigarzneimittel mit isotonischer Kochsalzlösung zubereitet, um z. B. für Notfallsituationen am Wochenende die Rezepturen vorrätig zu haben. Durch die Untersuchungen wurde geprüft, inwieweit der übliche Verdünnungsgrad von 0.1 % einen Einfluss auf die Stabilität des Noradrenalins hat und welche Lagerungsbedingungen für die Zubereitungen empfohlen werden können. Nach der Lagerung unter verschiedenen Bedingungen (gekühlt, bei Raumtemperatur sowie jeweils mit bzw. ohne Lichtschutz) konnte gezeigt werden, dass die Gehalte an Noradrenalin bei keiner der untersuchten Lagerungsbedingungen unter einen Wert von 99.0 % fielen. Individuell hergestellte Noradrenalin-Injektionslösungen können somit bis zu sieben Tage im Voraus hergestellt und für die Anwendung am Patienten bereit gehalten werden. Die Lösungen sollten dennoch gekühlt und unter Lichtschutz aufbewahrt werden, um den Abbau des Arzneistoffes und eine mikrobielle Kontamination zu minimieren.
LC-ESI und MALDI-Massenspektrometrische Analyse nativer und derivatisierter Zucker und Glykane
(2014)
Glykane sind weitverbreitete Biomoleküle, die meist in Form von Glykokonjugaten, wie beispielsweise als Glykoproteine oder Glykolipide, vorliegen. Durch die Interaktion von Glykanen mit Glykan-bindenden Proteinen wird eine Vielzahl an biochemischen Prozessen ausgelöst, sowohl physiologischer, als auch pathologischer Art. Die Aufklärung der beteiligten Glykanstrukturen ist daher nicht nur wichtig für das Verständnis dieser Prozesse, sondern kann auch Hinweise auf verschiedene Erkrankungen geben.
Die Identifizierung von Glykanstrukturen kann über verschiedene Wege erfolgen. In der instrumentellen Analytik spielt dabei vor allem die ESI- und MALDI Massenspektrometrie eine wichtige Rolle, da diese sowohl für Detektion, als auch Fragmentierung großer Biomoleküle geeignet sind. Um die Analyse von Zuckern mittels chromatographischer und massenspektrometrischer Methoden zu erleichtern, werden häufig Derivatisierungsreagenzien eingesetzt. Diese verringern die Polarität der Zucker und erleichtern die Detektion durch das Einbringen von Chromo- oder Fluorophoren. Zur Derivatisierung am reduzierenden Terminus von Glykanen und Zuckern eignen sich vor allem Aminierungsreagenzien oder Hydrazide. Hydrazide haben gegenüber anderen Derivatisierungsreagenzien den Vorteil einer einfachen, salzfreien Umsetzung, aus der ein stabiles Derivat mit geschlossenem terminalen Zuckerring hervorgeht.
Für die vorliegende Arbeit wurde die Derivatisierung mit den neuen Hydrazid Reagenzien INH und BINH, sowie dem bereits von Dr. P. Kapková bearbeiteten BACH untersucht. Als Vergleich dienten die underivatisierten Kohlenhydrate, wie auch das standardmäßig eingesetzte Aminierungsreagenz 2-AB. Dabei sollte das Ver-halten verschiedener Zucker und Glykane in Bezug auf chromatographische Trennung, Signalintensität und Fragmentierung analysiert werden.
Zunächst wurde die Umsetzung von Mono-, Di- und Trisacchariden mit den neuen Derivatisierungsreagenzien INH und BINH optimiert. Dadurch konnte bei beiden Substanzen die komplette Umsetzung der Zucker in ihre Derivate gewährleistet werden. Auch die Derivatisierung mit Hilfe der Mikrowelle konnte bei INH erfolgreich durchgeführt werden. Auf diese Weise ließ sich die Reaktionszeit, im Vergleich zu den im Thermo-mixer® benötigten 90 Minuten, auf 20 Minuten verkürzen. Aufgrund der großen Men-gen an Zucker und Derivatisierungsreagenz, die für die Umsetzung in der Mikrowelle nötig sind, war der Versuch jedoch nur für INH geeignet.
Im nächsten Schritt wurde das Trennverhalten der verschiedenen Mono-, Di- und Tri-saccharid-Derivate auf RP-C18- und HILIC-Phasen untersucht. Bei den Monosaccha-riden konnte durch keines der Derivate eine vollständige Trennung auf einer der Pha-sen erreicht werden. Das beste Ergebnis wurde durch INH auf der HILIC-Säule erzielt, doch auch dort konnten die Epimere Glucose, Mannose und Galactose nicht vollstän-dig separiert werden. Die Trennung der Disaccharide Maltose, Cellobiose und Lactose konnte auf der HILIC-Phase mit allen Derivaten außer BACH erfolgreich durchgeführt werden, auf der RP-C18 erwies sich dagegen nur 2-AB als geeignet. Bei den Trisac-chariden 3'SLN und 6'SLN konnten sowohl underivatisierte Zucker, als auch sämtliche Derivate mittels HILIC getrennt werden. Auch auf der C18-Phase war eine Trennung der BINH, BACH und 2-AB-Derivate möglich. Des Weiteren konnte durch die Derivati-sierungen die Signalintensität gegenüber den underivatisierten Zuckern deutlich gesteigert werden.
Nach ihrer Trennung lassen sich massegleiche Di- und Trisaccharide anhand des Fragmentierungsmusters unterscheiden. Während bei den underivatisierten Disaccha-riden Maltose, Cellobiose und Lactose die charakteristischen Fragmente nur schwach sichtbar waren, konnte mit Hilfe der Hydrazide INH, BINH und BACH die Differenzie-rung deutlich erleichtert werden. Die 2-AB-Derivatisierung zeigte dagegen keine Ver-besserung der Fragmentierungseigenschaften. Bei der Unterscheidung der Trisaccharide 3’SLN und 6’SLN waren ebenfalls sowohl underivatisierte, als auch Hydrazid-derivatisierte Zucker im Vorteil gegenüber den 2-AB-Derivaten.
Die Derivatisierung der N-Glykane von Ribonuclease B und Ovalbumin führte bei der Analyse mittels MALDI-TOF zu einer deutlichen Steigerung der Sensitivität. Beispiels-weise ließen sich bei den Glykanen des Ovalbumins durch die Derivatisierungen drei zusätzliche Strukturen im Vergleich zu den nativen Glykanen detektieren. Auch das Fragmentierungsverhalten der Glykane am MALDI-TOF/TOF konnte mit Hilfe der Derivatisierungen erheblich verbessert werden. Besonders die Umsetzung mit BINH führte zu einer Vielzahl charakteristischer Ringfragmente, wodurch die Aufklärung der verschiedenen Glykanstrukturen deutlich vereinfacht wurde. Auch im Vergleich zu 2 AB zeigten die Hydrazid-Derivate sowohl bessere Fragmentierungseigenschaften, als auch eine einfachere Handhabung für die Messung mittels MALDI-MS.
Eine weitere Möglichkeit zur Identifikation von Glykanstrukturen liegt in der spezifischen Bindung durch Lektine. Diese Untersuchung gibt des Weiteren auch einen Hinweis auf funktionelle Eigenschaften der Glykane. Dafür wird die hohe Affinität von Biotin-haltigen Derivatisierungsreagenzien zu Avidin und Streptavidin genutzt. Nach der auf diese Weise erfolgten Immobilisierung der Glykane können diese mittels spezifischer Lektine nachgewiesen werden. Die Eignung des neuen Derivatisierungsreagen-zes BINH für diese Zwecke wurde anhand eines Glykan-Arrays getestet. Dadurch ließ sich bestätigen, dass BINH-derivatisierte Glykane und Zucker sowohl in der Lage sind an Streptavidin zu binden, als auch durch Lektine nachgewiesen werden können. Daher kann davon ausgegangen werden, dass BINH grundsätzlich für den Einsatz in bio-chemischen Methoden geeignet ist.
Zusammenfassend lässt sich sagen, dass die Derivatisierung von Kohlenhydraten mit INH, BINH und BACH zu einer deutlichen Verbesserung der Trenn- und Fragmentierungseigenschaften führten. Dadurch konnten Identifizierung und Strukturanalyse sowohl von kleinen Zuckern, als auch von Glykanen erleichtert werden. Im Vergleich zu dem Standard-Derivatisierungsreagenz 2-AB zeigten die Hydrazide nicht nur im Bereich der Fragmentierungen, sondern auch durch die einfachere Derivatisierungsreaktion wesentliche Vorteile.
The aim of this work was to synthesize and functionalize different bio-relevant nanomaterials like silica-coated superparamagnetic iron oxide nanoparticles (SPIONs) as contrast agents for T2 magnetic resonance imaging (MRI) and detonation nanodiamond (DND) with the neurohormone peptide allatostatin 1 (ALST1) and a fluorescent dye. Analytical techniques for the determination and quantification of surface functional groups like amines, azides, and peptides were also developed and established.
Thus, in the first part of the work, a TGF-1 binding peptide and allatostatin 1 (ALST1), both supposed to act as active tumour targeting vectors, were synthesized by solid-phase peptide synthesis (SPPS) and characterized by high pressure liquid chromatography (HPLC) and mass spectrometry. Then, azide-functionalized silica nanoparticles were synthesized by the Stöber process and characterized by transmission electron microscopy (TEM) and infrared spectroscopy (IR). The surface loading of amine and azide groups was determined by a new protocol. The azide groups were reduced with sodium boronhydride to amine and then functionalized with Fmoc-Rink Amide linker according to a standard SPPS protocol. Upon cleavage of Fmoc by piperidine, the resulting dibenzofulvene and its piperidine adduct were quantified by UV/Vis spectroscopy and used to determine the amount of amine groups on the nanoparticle surface. Then, ALST1 and related tyrosine- and phenylalanine substituted model peptides were conjugated to the azide-functionalized silica nanoparticles by copper(I)-catalyzed azide-alkyne dipolar cycloaddition (CuAAC). The successful peptide conjugation was demonstrated by the Pauly reaction, which however is only sensitive to histidine- and tyrosine-containing peptides. As a more general alternative, the acid hydrolysis of the peptides to their individual amino acid building blocks followed by derivatization with phenyl isothiocyanate (PITC) allowed the separation, determination, and quantification of the constituent amino acids by HPLC.
In the second part of the work, amine- and azide-functionalized silica-coated superparamagnetic iron oxide nanoparticles (SPIONs) were synthesized by co-precipitation and subsequent silica-coated based on the Stöber process and characterized by TEM and IR. The amine surface loading was determined by the method already established for the pure silica systems. The azide surface loading could also be quantified by reduction with sodium boronhydride to amine groups and then conjugation to Fmoc-Rink amide linker. Upon cleavage of Fmoc with piperidine, the total amine surface loading was obtained. The amount of azide surface groups was then determined from the difference of the total amine surface loading and the amine surface loading. Thus, it was possible to quantify both amine and azide surface groups on a single nanoparticle system. Superparamagnetic iron oxide nanoparticles (SPIONs) are potent T2 contrast agents for magnetic resonance imaging (MRI). Due to their natural metabolism after injection into the blood stream, SPIONs mostly end up inside macrophages, liver, spleen or kidneys. To generate a potential target-specific SPION-based T2 contrast agent for MRI, the neurohormone peptide ALST1 was conjugated by CuAAC to the azide- and amine functionalized superparamagnetic iron oxide nanoparticles, since ALST1 is supposed to target difficult-to-treat neuroendocrinic tumours due to its analogy to galanin and somastatin receptor ligands. The organic fluorescent dye cyanine 5 (Cy5) was also conjugated to the silica-coated superparamagnetic iron oxide nanoparticles (SPIONs) via a NHS-ester to the amines to enable cell uptake studies by fluorescence microscopy. These constructs were characterized by TEM, dynamic light scattering (DLS), and IR. The amino acids of the conjugated ALST1 were determined by the HPLC method as described before for peptide-modified silica nanoparticle surfaces. Then, the relaxivity r2 was measured at 7 T. However, a r2 value of 27 L/mmolFe·s for the dual ALST1-/Cy5-functionalized silica-coated SPIONs was not comparable to T2 contrast agents in clinical use, since their relaxivity is commonly determined at 1.5 T, and no such instrument was available. However, it can be assumed that the synthesized dual
ALST1-/Cy5-functionalized silica-coated SPION would show a lower r2 at 1.5 T than at 7T. Commercial T2 MRI contrast agents like VSOP-C184 from Ferropharm show at r2 values of about 30 L/mmolFe·s at 1.5 T. Still, the relaxivity of the new material has some potential for application as a T2 contrast agent. Then, the material was used in cell uptake studies by fluorescence microscopy with the conjugated Cy5 dye as a probe. The dual
ALST1-/Cy5-functionalized silica-coated SPION showed a high degree of agglomeration with no cellular uptake unlike described for ALST1-functionalized nanoparticles in literature. It is assumed that upon agglomeration of the particles, constructs form which are unable to be internalized by the cellular endocytotic pathways anymore. As a future perspective, the tendency of the particle to agglomerate should be reduced by changing the coating material to polyethylene glycol (PEG) or chitosan, which are known to be bio-compatible, bio-degradable and prevent agglomeration.
In the third part of the work, the rhenium compound [ReBr(CO)3(L)] with L = 2-phenyl-1H-imidazo[4,5-f][1,10]phenanthroline and its manganese analogue were synthesized by heating the ligand and rhenium pentacarbonyl bromide or and manganese pentacarbonyl bromide respectively, in toluene. However, [MnBr(CO)3(L)] was unstable upon illumination by UV light at 365 nm. Thus, it was dismissed for further application. The photophysical properties of [ReBr(CO)3(L)] were explored, by determination of the excited-state life time by the time-correlated single-photon counting (TCSPC) method and the quantum yield by a fluorescence spectrometer equipped with an integration sphere. A value of = 455 ns, a Stokes shift of 197 nm and a rather low quantum yield =were found. Metal complexes are supposed to have superior properties compared to organic dyes due to their large Stokes shifts, long excited-state life times, and high quantum yields. Thus, amine- and azide-functionalized detonation nanodiamond (DND) as an alternative biological inert carrier system was functionalized with ALST1 to enhance its cell uptake properties. A luminescent probe for cell uptake studies using fluorescence microscopy was also attached, either based on the new rhenium complex or the commercially available organic dye Cy5, respectively. The aldehyde-functionalized rhenium complex was conjugated to the DND via oxime ligation, which is known to be a mild and catalyst-free conjugation method. The amount of peptide ALST1 on the DND was analyzed and quantified after acid hydrolysis and PITC derivatization by HPLC as described before. Then, the ALST1-/luminescent probe-functionalized DND was investigated for its photophysical properties by fluorescence spectroscopy. The Cy5-functionalized material showed a slightly lower fluorescence performance in aqueous solution than reported in literature and commercial suppliers with a life time < 0.4 ns and quantum yields not determinable by integration sphere due to the week signal intensity. The rhenium complex-functionalized material had a very low signal intensity in only aqueous medium, and thus determination of life times and quantum yield by fluorescence spectroscopy was not possible. After incubation with MDA-MB 231 cells, the Cy5-functionalized DND could easily be detected due to its red fluorescence. However, it was not possible to visualize the rhenium complex-functionalized DND with fluorescence microscopy due to the low fluorescence intensity of the complex in aqueous medium and the lack of proper filters for the fluorescence microscope. Cy5-functionalized DND did not show any cellular uptake in fluorescence microscopy after conjugation with ALST1. Since the nanodiamond surface is known to strongly adsorb peptides and proteins, it is assumed that the peptide chain is oriented perpendicular to the nanoparticle surface and thus not able to interact with cell membrane receptors to promote cell uptake of the particles. As a future perspective, the ALST1-promoted cellular uptake of the DND should be improved by using different linker systems for peptide conjugation to prevent adsorption of the peptide chain on the particle surface.
The new analytical methods for amino-, azide-, and peptide-functionalized nanoparticles have great potential to assist in the quantification of nanoparticle surface modifications by UV/Vis spectroscopy and HPLC. The determination of surface amine and azide groups based on the cleavage of conjugated Fmoc-Rink amide linker and detected by UV/Vis spectroscopy is applicable to all amine-/azide-functionalized nanomaterials. However, particles which form very stable suspension with the cleavage mixture can cause quantification problems due to scattering, making an accurate quantification of dibenzofulvene and its piperidine adduct impossible. The detection of tyrosine- and histidine-containing peptides based on the Pauly reaction is well-suited as a fast and easy-to-perform qualitative demonstration of successful peptide surface conjugation. However, its major drawback as a colourimetric approach is that coloured particles cannot be evaluated by this method. The amino acid analysis based on HPLC after acid hydrolysis of peptides conjugated to nanoparticle surfaces to its individual building blocks and subsequent derivatization with PITC, can be used on all nanomaterials with peptide or protein surface modification. It allows detection of amino acids down to picomolar concentrations and even enables analysis of very small peptide surface loadings. However, the resulting HPLC traces are difficult to analyze.
Three new analytical methods based on UV/Vis and HPLC techniques have been developed and established. They assisted in the characterization of the synthesized DND and SPIONs with dual functionalization by ALST1 and Cy5 or [ReBr(CO)3(L)], respectively. However, the nanomaterials showed no cellular uptake due to a high tendency to agglomerate. The cellular uptake should be improved and the tendency to agglomerate of the SPIONs should be reduced by changing the surface coating from silica to either PEG or chitosan. Furthermore, different linker systems for connecting peptides to DND surfaces should be synthesized and evaluated to reduce potential peptide chain adsorption.