The Mayo conservative hip: complication analysis and management of the first 41 cases performed at a University level 1 department

Zitieren Sie bitte immer diese URN: urn:nbn:de:bvb:20-opus-157812
  • Background: To prevent bone loss in hip arthroplasty, several short stem systems have been developed, including the Mayo conservative hip system. While there is a plethora of data confirming inherent advantages of these systems, only little is known about potential complications, especially when surgeons start to use these systems. Methods: In this study, we present a retrospective analysis of the patients’ outcome, complications and the complication management of the first 41 Mayo conservative hips performed in 37 patients. For this reason,Background: To prevent bone loss in hip arthroplasty, several short stem systems have been developed, including the Mayo conservative hip system. While there is a plethora of data confirming inherent advantages of these systems, only little is known about potential complications, especially when surgeons start to use these systems. Methods: In this study, we present a retrospective analysis of the patients’ outcome, complications and the complication management of the first 41 Mayo conservative hips performed in 37 patients. For this reason, functional scores, radiographic analyses, peri- and postoperative complications were assessed at an average follow-up of 35 months. Results: The overall HHS improved from 61.2 pre-operatively to 85.6 post-operatively. The German Extra Short Musculoskeletal Function Assessment Questionnaire (XSFMA-D) improved from 30.3 pre-operatively to 12.2 post-operatively. The most common complication was an intraoperative non-displaced fracture of the proximal femur observed in 5 cases (12.1%). Diabetes, higher BMI and older ages were shown to be risk factors for these intra-operative periprosthetic fractures (p < 0.01). Radiographic analysis revealed a good offset reconstruction in all cases. Conclusion: In our series, a high complication rate with 12.1% of non-displaced proximal femoral fractures was observed using the Mayo conservative hip. This may be attributed to the flat learning curve of the system or the inherent patient characteristics of the presented cohort."zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Autor(en): Jörg Arnholdt, Fabian Gilbert, Marc Blank, Jannis Papazoglou, Maximilian Rudert, Ulrich Nöth, Andre F. Steinert
URN:urn:nbn:de:bvb:20-opus-157812
Dokumentart:Artikel / Aufsatz in einer Zeitschrift
Institute der Universität:Medizinische Fakultät / Lehrstuhl für Orthopädie
Medizinische Fakultät / Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II)
Sprache der Veröffentlichung:Englisch
Titel des übergeordneten Werkes / der Zeitschrift (Englisch):BMC Muskoskeletal Disorders
Erscheinungsjahr:2017
Band / Jahrgang:18
Heft / Ausgabe:250
Originalveröffentlichung / Quelle:BMC Musculoskeletal Disorders (2017) 18:250. DOI: 10.1186/s12891-017-1613-2
DOI:https://doi.org/10.1186/s12891-017-1613-2
Allgemeine fachliche Zuordnung (DDC-Klassifikation):6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 617 Chirurgie und verwandte medizinische Fachrichtungen
Freie Schlagwort(e):mayo stem; minimal invasive surgery; short hip stem; total hip arthroplasty
Datum der Freischaltung:23.02.2018
Sammlungen:Open-Access-Publikationsfonds / Förderzeitraum 2017