• search hit 5 of 7
Back to Result List

Signal voids of active cardiac implants at 3.0 T CMR

Please always quote using this URN: urn:nbn:de:bvb:20-opus-300502
  • Recent technical advancements allow cardiac MRI (CMR) examinations in the presence of so-called MRI conditional active cardiac implants at 3.0 T. However, the artifact burden caused by susceptibility effects remain an obstacle. All measurements were obtained at a clinical 3.0 T scanner using an in-house designed cubic phantom and optimized sequences for artifact evaluation (3D gradient echo sequence, multi-slice 2D turbo spin echo sequence). Reference sequences according to the American Society for Testing and Materials (ASTM) were additionallyRecent technical advancements allow cardiac MRI (CMR) examinations in the presence of so-called MRI conditional active cardiac implants at 3.0 T. However, the artifact burden caused by susceptibility effects remain an obstacle. All measurements were obtained at a clinical 3.0 T scanner using an in-house designed cubic phantom and optimized sequences for artifact evaluation (3D gradient echo sequence, multi-slice 2D turbo spin echo sequence). Reference sequences according to the American Society for Testing and Materials (ASTM) were additionally applied. Four representative active cardiac devices and a generic setup were analyzed regarding volume and shape of the signal void. For analysis, a threshold operation was applied to the grey value profile of each data set. The presented approach allows the evaluation of the signal void and shape even for larger implants such as ICDs. The void shape is influenced by the orientation of the B0-field and by the chosen sequence type. The distribution of ferromagnetic material within the implants also matters. The void volume depends both on the device itself, and on the sequence type. Disturbances in the B0 and B1 fields exceed the visual signal void. This work presents a reproducible and highly defined approach to characterize both signal void artifacts at 3.0 T and their influencing factors.show moreshow less

Download full text files

Export metadata

Additional Services

Share in Twitter Search Google Scholar Statistics
Metadaten
Author: Theresa Reiter, Ingo Weiss, Oliver M. Weber, Wolfgang R. Bauer
URN:urn:nbn:de:bvb:20-opus-300502
Document Type:Journal article
Faculties:Medizinische Fakultät / Medizinische Klinik und Poliklinik I
Language:English
Parent Title (English):Scientific Reports
Year of Completion:2022
Volume:12
Issue:1
Article Number:6285
Source:Scientific Reports 2022, 12(1):6285. DOI: 10.1038/s41598-022-09690-z
DOI:https://doi.org/10.1038/s41598-022-09690-z
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Tag:cardiac MRI; cardiac implants; signal voids
Release Date:2023/04/05
Collections:Open-Access-Publikationsfonds / Förderzeitraum 2022
Licence (German):License LogoCC BY: Creative-Commons-Lizenz: Namensnennung 4.0 International