Method development, optimization, and validation of the separation of ketamine enantiomers by capillary electrophoresis using design of experiments

Zitieren Sie bitte immer diese URN: urn:nbn:de:bvb:20-opus-324713
  • Capillary electrophoresis was chosen as cost-effective and robust method to separate ketamine enantiomers. For the method development, first different native and modified cyclodextrins were tested. The most promising chiral selector was α-cyclodextrin. A design of experiments (DoE) was carried out, which started with the screening of relevant factors. Based on these results, the method was optimized according to the significant factors (buffer, cyclodextrin concentration, pH value, voltage, temperature) of the screening based on the responseCapillary electrophoresis was chosen as cost-effective and robust method to separate ketamine enantiomers. For the method development, first different native and modified cyclodextrins were tested. The most promising chiral selector was α-cyclodextrin. A design of experiments (DoE) was carried out, which started with the screening of relevant factors. Based on these results, the method was optimized according to the significant factors (buffer, cyclodextrin concentration, pH value, voltage, temperature) of the screening based on the response resolution and migration time of the later migrating enantiomer. The optimized conditions consisted of a background electrolyte with 275 mM TRIS, adjusted with 85% phosphoric acid to a pH of 2.50, and 50 mM α-cyclodextrin, at a temperature of 15 °C, an applied voltage of 30 kV and an injection pressure of 1.0 psi for 10 s. A fused-silica capillary with a total length of 70 cm and an effective length to the detector of 60 cm was used. The method was validated according to ICH guideline Q2 R(1). The limit of quantification was 3.51 µg mL\(^{−1}\) for S-ketamine and 3.98 µg mL\(^{−1}\)for R-ketamine. The method showed good linearity for racemic ketamine with R\(^2\) of 0.9995 for S-ketamine and 0.9994 for R-ketamine. The lowest quantifiable content of S-ketamine found in R-ketamine was 0.45%.zeige mehrzeige weniger

Volltext Dateien herunterladen

Metadaten exportieren

Weitere Dienste

Teilen auf Twitter Suche bei Google Scholar Statistik - Anzahl der Zugriffe auf das Dokument
Metadaten
Autor(en): Sebastian Schmidt, Ulrike HolzgrabeORCiD
URN:urn:nbn:de:bvb:20-opus-324713
Dokumentart:Artikel / Aufsatz in einer Zeitschrift
Institute der Universität:Fakultät für Chemie und Pharmazie / Institut für Pharmazie und Lebensmittelchemie
Sprache der Veröffentlichung:Englisch
Titel des übergeordneten Werkes / der Zeitschrift (Englisch):Chromatographia
ISSN:0009-5893
Erscheinungsjahr:2023
Band / Jahrgang:86
Heft / Ausgabe:1
Seitenangabe:87-95
Originalveröffentlichung / Quelle:Chromatographia (2023) 86:1, 87-95. DOI: 10.1007/s10337-022-04229-w
DOI:https://doi.org/10.1007/s10337-022-04229-w
Allgemeine fachliche Zuordnung (DDC-Klassifikation):6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Freie Schlagwort(e):capillary electrophoresis; cyclodextrins; design of experiments; enantiomers; ketamine
Datum der Freischaltung:11.03.2024
Lizenz (Deutsch):License LogoCC BY: Creative-Commons-Lizenz: Namensnennung 4.0 International