Refine
Is part of the Bibliography
- yes (244)
Year of publication
Document Type
- Journal article (129)
- Doctoral Thesis (113)
- Other (1)
- Preprint (1)
Keywords
- MRI (22)
- NMR-Tomographie (19)
- MRT (16)
- magnetic resonance imaging (13)
- Kernspintomografie (8)
- Herzinfarkt (7)
- Computertomographie (6)
- Quantifizierung (6)
- mri (6)
- Bildgebendes Verfahren (5)
Institute
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (244) (remove)
Sonstige beteiligte Institutionen
- Cheng Lab, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA (1)
- Datenintegrationszentrum Würzburg (DIZ) (1)
- Interdisziplinäre Biomaterial- und Datenbank Würzburg (ibdw) (1)
- Würzburg Fabry Center for Interdisciplinary Therapy (FAZIT), University of Würzburg, Würzburg, Germany (1)
In der S3-Leitlinie „Diagnostik und Therapie des Morbus Crohn“ von 2008 war lediglich die Sonographie als primär bildgebendes Verfahren verankert; der Einsatz der Dünndarm-MRT blieb optional und ohne feste Position im Diagnostik-Algorithmus der CED. Im Unterschied hierzu stärkt die 2014 aktualisierte entsprechende S3-Leitlinie den Stellenwert der MRT als bildgebende Modalität. Weiterhin bestehen bleibt die Sonographie als primäre Bildgebung; eine MRT soll jedoch ebenfalls erfolgen: zur Primärdiagnostik, zur Erkennung extraintestinaler Komplikationen und zur Beurteilung endoskopisch nicht einsehbarer Darmabschnitte. Darüber hinaus kann sie in Verlaufskontrollen angewendet werden, falls erforderlich. Da sich diese jungen Patienten bei langer Krankheitsdauer in der Regel einer hohen Zahl an Untersuchungen unterziehen, sollte die Möglichkeit, dies strahlenexpositionsfrei durchführen zu können, unbedingt gewährleistet werden. Andernfalls ist mit einer erhöhten Rate an Malignomen im späteren Lebensalter zu rechnen.
Daraus ergibt sich die Bedeutung einer Korrelation von mittels Ultraschall wie MRT erhobenen Befunden bei kindlicher CED. Hierzu liegen bislang nur wenige Untersuchungen vor, die zumeist auf den additiven Wert der Sonographie zur MRT und/oder dem additiven Wert der MR-Perfusionsanalyse fokussieren. Der hier vorgestellte Ansatz einer direkten Korrelation der Parameter Wanddicke und Perfusionsmarker zwischen Sonographie und MRT sowie gegenüber klinischen Aktivitätsmarkern (shPCDAI) ist innovativ.
Für das MRT konnten wir eine signifikante Korrelation von Wanddicke und Signalintensitätszunahme zwei Minuten nach Kontrastmittelgabe für das terminale Ileum, der Prädilektionsstelle des Morbus Crohn, nachweisen. Ein Zusammenhang zwischen Wanddicke und klinischem Aktivitätsindex konnte nicht gezeigt werden, jedoch zwischen Signalintensitätszunahme und short PCDAI. Die Perfusionsanalyse sollte daher unserer Ansicht nach bei MRT-Untersuchungen zur Beantwortung der Frage „aktive Entzündung“ herangezogen werden.
Für die Sonographie konnten wir keinen Zusammenhang von Wanddicke und Perfusion, jedoch eine signifikante Korrelation von Wanddicke und short PCDAI nachweisen. Die Perfusion korrelierte wiederum nicht mit dem klinischen Aktivitätsindex. Die morphologische Wanddickenanalyse sollte daher für Sonographie-Untersuchungen zur Beantwortung der Frage „aktive Entzündung“ herangezogen werden.
Bei der Korrelation der MRT- und Sonographie-Ergebnisse zeigte sich ein gutes Übereinstimmen der Daten der Darmwanddicken-Messungen, die höchste Korrelation ergab sich im terminalen Ileum. Auch für Signalintensitätszunahmen (MRT) und Perfusion (FKDS) zeigte sich ein gutes Übereinstimmen – mit Ausnahme des Rektosigmoids (späte KM-Phase). Die größte Korrelation war auch hier im terminalen Ileum zu finden. Dies belegt die gute Vergleichbarkeit beider Modalitäten. Eine Korrelation von MRAIs – USAI – shPCDAI ließ sich nicht nachweisen. Dies könnte an einer divergenten Einschätzung der Erkrankungsaktivität, jedoch auch an der kleinen Fallzahl liegen. Zur Erstellung des shPCDAI waren die retrospektiv erhobenen Variablen teils nicht ausreichend. Hauptlimitation für den USAI war die – teils durch Darmgasüberlagerung bedingte – unvollständige Dokumentation. Die Stärke des MRAI lag dagegen bei konstant vorliegenden Messungen in fünf Darmabschnitten.
Trotz dieser Limitationen belegt die vorliegende Arbeit die Gleichwertigkeit beider Methoden in der Beurteilung von Darmwanddicken und eine bessere Korrelation wie Aussagekraft der MRT bei der Perfusionsanalyse. Aktuelle Publikationen belegen die Bedeutung Diffusionsgewichteter-MR-Bildgebung bei der CED-Diagnostik. Die DWI wurde im Rahmen unserer Untersuchung nicht angewendet, wird aber in Zukunft als vielversprechender, additiver Baustein oder sogar Ersatz für die Kontrastmittelgabe (Perfusionsanalyse) für MRT bei CED zu evaluieren sein.
Die 31P-MRS ist aktuell die einzige verfügbare nicht-invasive Methode mit der der Herzmetabolismus ohne radioaktive Tracer untersucht werden kann. MRS ermöglicht Einblicke in die Energetik der ischämischen Herzkrankheit, des Herzinfarkts, der hypertrophen Kardiomyopathie oder auch der Herzklappenfehler. Ferner kann die Methode zur Überwachung des Therapieerfolgs o.g. Krankheiten genutzt werden. Gegenwärtig wird die MR-Spektroskopie, aufgrund der geringen räumlichen und zeitlichen Auflösung sowie der geringen Reproduzierbarkeit, jedoch nur in der Forschung angewendet. Die Einführung von MRT-Sytemen höherer Feldstärke, z.B. 7 Tesla, wird vermutlich eine Optimierung der Auflösung und Reproduzierbarkeit ermöglichen und damit die 31P-MRS in die klinische Diagnostik integrieren können. Die vorliegende Arbeit befasst sich neben der methodischen Weiterentwicklung und Standardisierung der MRS mit einem direkten Vergleich MR-tomographischer (LE) und MR-spektroskopischer (AW-CSI) Techniken zur Detektion von Infarktfolgen. Hierbei konnte durch die simultane Anwendung von MRS und Late Enhancement, ein bereits in der klinischen Infarktdiagnostik etabliertes Verfahren, die Aussagekraft der MR-Spektroskopie in Bezug auf die Infarktlokalisation validiert werden. Ein wesentlicher Vorteil der MRS gegenüber dem Late Enhancement besteht darin, dass bereits frühzeitig pathologische Veränderungen des Metabolismus in Arealen wie dem remote, stunned oder hibernating myocardium detektiert werden können. Letztere demarkieren sich nicht beim LE. Unter Etablierung eines Segmentationsalgorithmus konnten sehr niedrige Variabilitäten bei dem verwendeten Quantifizierungsprogramm („SLOOP“) erreicht werden. Zusätzlich gelang es durch systematische Analysen die für die Auswertung der MRS benötigten Nachbearbeitungszeiten drastisch zu verkürzen. Als klinische Anwendung erfolgte die Bestimmung des kardialen Metabolismus mittels akquisitionsgewichteter 31P-3D-CSI bei Patienten mit Hinterwandinfarkt. Damit konnten erstmalig spulenferne Myokardareale (Hinterwand) hinsichtlich Veränderungen im Metabolismus erfasst werden. Veränderte PCr/γATP-ratios wurden bei Infarktpatienten gegenüber einem Kollektiv herzgesunder Probanden gefunden. Eine exakte Lokalisation der untersuchten Infarkte und damit eine Validierung der spektroskopischen Datenanalyse wurden durch den Vergleich mit den simultan aufgenommenen Late Enhancement Bildern möglich. Damit eröffnet sich in Verbindung mit zunehmend zur Verfügung stehenden Hochfeldgeräten (3T und mehr) für die MRS der Weg zu einem wichtigen klinischen Diagnostikwerkzeug zur Bestimmung von Prognoseparametern bei kardialen Erkrankungen.
Mit dem hier vorgestellten Untersuchungs- und Auswertealgorithmus konnte die Myokardperfusion weitgehend automatisiert semiquantitativ und quantitativ bestimmt werden. Dafür wurden zunächst die Bilddaten segmentiert und in Signalintensitäts-Zeit-Kurven transferiert. Durch eine Basislinien- und Kontaminationskorrektur wurden Artefakte minimiert. Mit Anwendung des Parallel-Bildgebungs-Verfahrens Auto-SENSE konnte zusätzlich eine Erhöhung der Schichtanzahl erreicht werden. Durch die angewendete Basislinienkorrektur konnten Inhomogenitäten verringert werden, welche durch Verwendung einer Oberflächenspule methodenbedingt auftreten. Partialvolumeneffekte, die durch die Morphologie des Herzens insbesondere basis- und spitzennah auftraten, führten durch eine Mischung aus KM-Anflutung im Myokard und Kontamination aus dem Ventrikellumen zu einer Beeinflussung der Perfusionsergebnisse. Durch die Verwendung der vorgestellten Kontaminationskorrektur konnten diese Artefakte erheblich minimiert werden. Die so errechneten Perfusionswerte korrelierten gut mit den in der Literatur angegebenen Daten, welche sowohl in tierexperimentellen als auch Probanden- und auch Patientenstudien mit unterschiedlichen Modalitäten ermittelt wurden. Eine regionale Heterogenität konnte nicht signifikant nachgewiesen werden. Molekular-physiologische Untersuchungen legen zwar nahe, dass es diese Heterogenität gibt, die regionale Verteilung der Perfusion wird jedoch kontrovers und noch keinesfalls abschließend in der Literatur diskutiert. Durch Anwendung von Auto-SENSE konnte mit einer Erhöhung der Schichtanzahl bei gleichbleibender Schichtdicke das gesamte linksventrikuläre Myokard untersucht werden. Trotz verringertem SNR waren die Ergebnisse vergleichbar mit der konventionellen Turbo-FLASH-Technik. Ob das Potential der Parallelbildgebung für eine Abdeckung des gesamten Herzens oder für eine höhere Auflösung von 3-4 Schichten pro Untersuchungen genutzt werden soll, ist in der aktuellen Literatur noch Gegenstand der Diskussion. Die hochaufgelösten Untersuchungen scheinen jedoch derzeit vorteilhafter aufgrund geringerer Partialvolumeneffekte sowie der besseren Beurteilbarkeit einer subendokardialen Zone und eines transmuralen Perfusionsgradienten. Die MR-Perfusionsbildgebung ist ein aktives und rasch wachsendes Gebiet innerhalb der kardialen Bildgebung mit großem Entwicklungspotential. Durch Einbindung in ein umfassendes Herz-MR-Untersuchungsprotokoll (z.B. Morphologie, Kinetik, evtl. MR-Koronarangiographie) ist in einem Untersuchungsgang eine umfassende Diagnostik bei Patienten mit Verdacht auf KHK möglich.
Background
Diagnosis of subscapularis (SSC) tendon lesions on magnetic resonance imaging (MRI) can be challenging. A small coracohumeral distance (CHD) has been associated with SSC tears. This study was designed to define a specific threshold value for CHD to predict SSC tears on axial MRI scans.
Methods
This retrospective study included 172 shoulders of 168 patients who underwent arthroscopic surgery for rotator cuff tear or glenohumeral instability. Diagnostic arthroscopy confirmed an SSC tear in 62 cases (36.0%, test group a), rotator cuff tear tears other than SSC in 71 cases (41.3%, control group b) and glenohumeral instability without any rotator cuff tear in 39 cases (22.7%, zero-sample group c). All patients had a preoperative MRI of the shoulder (1.5T or 3T). Minimum CHD was measured on axial fat-suppressed proton density-, T2-, or T1-weigthed sequences. Receiver operating characteristics analysis was used to determine the threshold value for CHD, and sensitivity and specificity were calculated.
Results
CHD measurement had a good interobserver reliability (Intraclass correlation coefficient 0.799). Mean CHD was highly significantly (P < .001) less for test group a (mean 7.3 mm, standard deviation ± 2.2) compared with control group b (mean 11.1 mm, standard deviation ± 2.3) or zero-sample group c (mean 13.6 mm, standard deviation ± 2.9). A threshold value of CHD <9.5 mm had a sensitivity of 83.6% and a specificity of 83.9% to predict SSC tears.
Conclusion
A CHD <9.5 mm on MRI is predictive of SSC lesions and a valuable tool to diagnose SSC tears.
Organfilter in der konventionellen Röntgendiagnostik und ihre Bedeutung für den Strahlenschutz
(2004)
Die vorliegende Arbeit untersucht den Effekt von Organfiltern insbesondere auf die Dosis. Im Rahmen dieser Untersuchung wurde die Dosis in Form des Flächendosisproduktes (FDP) gemessen. Filter bewirken nicht nur eine Verbesserung der Objektdarstellung in den normalerweise zu stark geschwärzten Randpartien, sondern auch eine Dosisreduktion, d.h. die Organfilter sind gut geeignet, den Strahlenschutz positiv zu beeinflussen. Dieser Effekt der Dosisreduktion war bei den Keilfiltern (Mittel- und Vorfuß sowie HWS) weniger deutlich als bei den für Schädel und Schulter angewendeten Filtern.
Due to the low frequency of abnormalities affecting the spleen, this organ is often overlooked during radiological examinations. Here, we report on the unexpected finding, that the spleen signal on diffusion-weighted MRI (DW-MRI) is associated with clinical parameters in patients with plasma cell dyscrasias. Methods: We investigated the spleen signal on DW-MRI together with clinical and molecular parameters in 295 transplant-eligible newly diagnosed Multiple Myeloma (NDMM) patients and in 72 cases with monoclonal gammopathy of undetermined significance (MGUS). Results: Usually, the spleen is the abdominal organ with the highest intensities on DW-MRI. Yet, significant signal loss on DW-MRI images was seen in 71 of 295 (24%) NDMM patients. This phenomenon was associated with the level of bone marrow plasmacytosis (P=1x10(-10)) and International Staging System 3 (P=0.0001) but not with gain(1q), and del(17p) or plasma cell gene signatures. The signal was preserved in 72 individuals with monoclonal gammopathy of undetermined significance and generally re-appeared in MM patients responding to treatment, suggesting that lack of signal reflects increased tumor burden. While absence of spleen signal in MM patients with high risk disease defined a subgroup with very poor outcome, re-appearance of the spleen signal after autologous stem cell transplantation was seen in patients with improved outcome. Our preliminary observation suggests that extramedullary hematopoiesis in the spleen is a factor that modifies the DW-MRI signal of this organ. Conclusions: The DW-MRI spleen signal is a promising marker for tumor load and provides prognostic information in MM.
Das Hauptziel der vorliegenden Arbeit war es, eine genauere Erkenntnis über die derzeitigen Möglichkeiten der quantitativen Messung der myokardiale Perfusion im Hinblick auf die Beschreibung verschiedener myokardialer Infarkte mittels kardialer MRT zu gewinnen. Die Untersuchungen zur Perfusion im Infarktgebiet ergaben, dass ein visuell festgestellter subendokardialer Infarkt an Hand der Bestimmung der absoluten Perfusion nicht immer nachvollzogen werden konnte. Ein Zusammenhang zwischen dem Auftreten eines no-reflow im Late Enhancement und der Höhe der absoluten Perfusion im Infarktgebiet konnte nicht gezeigt werden. Die Untersuchungen zur Perfusion im Remote Myokard ergaben keinen Zusammenhang zwischen der Perfusion im Remote Myokard und dem transmuralen Ausmaß des no-reflow-Phänomens in der First Pass Perfusion. Auch korrelierte die Perfusion im Remote Myokard nicht mit dem Auftreten eines no-reflow Phänomens im Late Enhancement. Die Perfusion im Remote Myokard unterschied sich zwischen transmuralen und nicht-transmuralen Infarkten. Eine Hyperperfusion im Remote Myokard konnte erst ab einer Infarktausdehnung von 75% im Late Enhancement beobachtet werden, während eine Hypoperfusion im Remote Myokard bei allen Infarktausdehnungen zwischen 0% und 100% auftrat. Die Untersuchungen zur Perfusion bei Vorliegen eines transmuralen Infarktes“ ergaben eine signifikante Korrelation der Perfusionen in Infarktgebiet und Remote Myokard bei transmuralem Infarkten. Die Ergebnisse zur Messung der Perfusion in Abhängigkeit von der relativen Infarktgröße wiesen keinen Zusammenhang zwischen der Perfusion im Infarktgebiet und der relativen Infarktgröße auf. Ebenso konnte keine Beziehung zwischen der Perfusion im Remote Myokard und der relativen Infarktgröße dargelegt werden. Letztendlich wurde das Verhalten der quantitativen Perfusion im Infarktgebiet und im Remote Myokard in Abhängigkeit von der Zeit nach Infarktereignis untersucht. Dabei zeigte sich kein Zusammenhang zwischen dem Auftreten eines no-reflow im Late Enhancement und der Entwicklung der Perfusion im Infarktgebiet zwischen der Erst- und der Spätuntersuchung. Ebenso war kein Zusammenhang zwischen dem Auftreten eines no-reflow im Late Enhancement und der Entwicklung der Perfusion im Remote Myokard zwischen der Erst- und der Spätuntersuchung erkennbar. Die kardiale MRT ist aufgrund der gleichzeitigen Analyse von morphologischen, funktionellen, quantitativen und metabolischen Parametern in einem Untersuchungsgang ein erfolgversprechendes Bildgebungsverfahren der Zukunft, da sie nicht invasiv ist, ohne Einsatz von Röntgenstrahlung auskommt und dabei eine gute räumliche Auflösung bei hohem Gewebekontrast bietet. Studien zeigen, dass die Kombination von Stress-Perfusion und Late-Technik in einem MRT-Protokoll eine höhere Genauigkeit als die Verwendung der SPECT-Untersuchung in der klinischen Beurteilung von Koronargefäßstenosen und im Nachweis subendokardialer Infarkte aufweist. 62 Allerdings erfährt die in vorliegender Arbeit verwendete Technik der Datenverarbeitung in dieser Form ohne Zweifel noch ihre Limitation im klinischen Alltag. Grundsätzlich ist zu sagen, dass die Messung der absoluten Perfusion im Myokard mit der MRT des Herzens zurzeit sicherlich noch nicht ausgereift ist. Dennoch lassen die in dieser Arbeit vorgestellten Ergebnisse und die viel versprechende Weiterentwicklung in der magnetresonanztomographischen Bildgebung weit reichende und interessante Möglichkeiten erahnen.
Ziel der vorliegenden Arbeit war es, einen genaueren Aufschluss über die Erfassung der mikrovaskulären Integrität von Myokardinfarkten nach erfolgreicher koronarer Revaskularisierung mittels kardialer MR-Bildgebungstechniken zu geben. Dazu wurde zuerst das Auftreten des „no-reflow“ in der FPP und im LE sowie zu verschiedenen Zeitintervallen untersucht. Die Untersuchungen hierzu ergaben ein häufigeres Auftreten des „no-reflow“ in den FPP-Untersuchungen und eine Abnahme des beobachtbaren „no-reflow“, je später die Untersuchung nach Kontrastmittelgabe erfolgte. Zusätzlich zeigte sich, dass das Auftreten eines „no-reflow“ in der LE-Untersuchung immer mit einem Auftreten in der FPP einherging. Weiterhin wurden die Auswirkungen des Infarktausmaßes auf das „no-reflow“ überprüft. Bei den Untersuchungen wurde zwischen Infarktvolumen und transmuraler Infarktgröße unterschieden. Dabei zeigte sich, dass das Auftreten eines „no-reflow“ in der FPP- und LE-Untersuchung besser mit dem relativen Infarktvolumen als mit dem transmuralen Infarktausmaß korrelierte. Infarkte mit einem relativen Volumen kleiner neun Prozent ließen kein „no-reflow“ im LE beobachten, wobei bei einem Infarktvolumen > 15 % ein „no-reflow“ sowohl in der FPP- als auch in der LE-Untersuchung beobachtbar war. Die Untersuchungen zum transmuralen Infarktausmaß zeigten, dass ein „no-reflow“ auch bei nicht transmuralen Infarkten auftrat. Daneben konnte beobachtet werden, dass auch transmurale Infarkte ohne „no-reflow“ auftreten. Des Weiteren wurden die Auswirkungen eines beobachtbaren „no-reflow“ auf die EF überprüft. Die EF wurde hierzu 14 Tage und drei Monate nach Myokardinfarkt bestimmt und mit dem „no-reflow“ in der FPP und im LE der Erstuntersuchung verglichen. Hierbei zeigten zum ersten Untersuchungszeitpunkt in der FPP-Untersuchung mehr als 50 % der Infarkte sowohl bei einer EF < 55 % als auch bei einer EF > 55 % ein „no-reflow“. Dagegen war in der LE-Untersuchung bei einer EF < 55 % kein Unterschied bezüglich der Beobachtung eines „no-reflow“ feststellbar, während bei einer EF > 55 % über 70 % der Infarkte kein „no-reflow“ aufwiesen. In der „Untersuchung nach drei Monaten“ zeigten in der FPP-Untersuchung bei einer EF < 55 % knapp 75 % der Infarkte ein „no-reflow“, während es bei einer EF > 55 % ungefähr 25 % waren. In der LE-Untersuchung war, ähnlich dem ersten Untersuchungszeitpunkt, bei einer EF < 55 % kein wesentlicher Unterschied festzustellen, wohingegen bei einer EF > 55 % über 75 % der Infarkte kein beobachtbares „no-reflow“ im LE zeigten. Für die FPP- und LE-Untersuchung ergab sich bei beiden Untersuchungszeitpunkten kein statistischer signifikanter Unterschied bezüglich der EF der Patienten, die „no-reflow“ zeigten, zu den Patienten, die kein „no-reflow“ zeigten. Ohne Zweifel ist die kardiale MRT aufgrund des nichtinvasiven dreidimensionalen Charakters und des guten Gewebekontrastes ohne Einsatz von Röntgenstrahlung ein viel versprechendes bildgebendes Verfahren der Zukunft. Der Vorteil der Anwendung dieses Verfahrens bei Patienten mit Myokardinfarkt ist die präzise Bewertung des transmuralen Ausmaßes der myokardialen Nekrose sowie des „no-reflow“ und die gleichzeitige Erfassung der Herzfunktionsparameter. Der Stand der Erfassung und Bewertung des „no-reflow“ in MRT-Bildern reicht jedoch zurzeit noch nicht für den Einsatz in der klinischen Routinediagnostik aus. Die in dieser Arbeit vorgestellten Ergebnisse sollen einen Beitrag für diese Weiterentwicklung leisten. Für einen späteren Standard zur Erfassung der mikrovaskulären Integrität beim Akuten Koronarsyndrom sind jedoch weitere Studien nötig. Hierbei wären genauere Untersuchungen zum Schweregrad des „no-reflow“ sowie zum Auftreten zu verschiedenen Zeitpunkten sinnvoll. Außerdem sollten exaktere Aussagen über die Korrelation des Auftretens des „no-reflow“ und den Herzfunktionsparametern erhoben werden. Es ist anzunehmen, dass sich durch eine Weiterentwicklung der kardialen MRT der Informationsgehalt in Zukunft stetig steigern wird und dadurch eine eindrucksvolle Ergänzung der kardiologischen Differentialdiagnostik sein. Dabei könnte eine multimodale Akquisition der kardialen Makro- und Mikrozirkulation, pathologischer Gewebeveränderungen und myokardialer Funktionsstörungen in einem Untersuchungsgang mit einem kurzen zeitlichen Aufwand erreicht werden. Durch Integration der MRT-Untersuchungen zum „no-reflow“ in den klinischen Alltag könnte somit eine Bestimmung des individuellen Risikos sowie ein risikoadaptiertes Behandlungskonzept erreicht werden.
This work deals with the acceleration of cardiovascular MRI for the assessment
of functional information in steady-state contrast and for viability assessment
during the inversion recovery of the magnetization. Two approaches
are introduced and discussed in detail. MOCO-MAP uses an exponential
model to recover dynamic image data, IR-CRISPI, with its low-rank plus
sparse reconstruction, is related to compressed sensing.
MOCO-MAP is a successor to model-based acceleration of parametermapping
(MAP) for the application in the myocardial region. To this end, it
was augmented with a motion correction (MOCO) step to allow exponential
fitting the signal of a still object in temporal direction. Iteratively, this
introduction of prior physical knowledge together with the enforcement of
consistency with the measured data can be used to reconstruct an image
series from distinctly shorter sampling time than the standard exam (< 3 s
opposed to about 10 s). Results show feasibility of the method as well as
detectability of delayed enhancement in the myocardium, but also significant
discrepancies when imaging cardiac function and artifacts caused already by
minor inaccuracy of the motion correction.
IR-CRISPI was developed from CRISPI, which is a real-time protocol
specifically designed for functional evaluation of image data in steady-state
contrast. With a reconstruction based on the separate calculation of low-rank
and sparse part, it employs a softer constraint than the strict exponential
model, which was possible due to sufficient temporal sampling density via
spiral acquisition. The low-rank plus sparse reconstruction is fit for the use on
dynamic and on inversion recovery data. Thus, motion correction is rendered
unnecessary with it.
IR-CRISPI was equipped with noise suppression via spatial wavelet filtering.
A study comprising 10 patients with cardiac disease show medical
applicability. A comparison with performed traditional reference exams offer
insight into diagnostic benefits. Especially regarding patients with difficulty
to hold their breath, the real-time manner of the IR-CRISPI acquisition provides
a valuable alternative and an increase in robustness.
In conclusion, especially with IR-CRISPI in free breathing, a major acceleration
of the cardiovascular MR exam could be realized. In an acquisition
of less than 100 s, it not only includes the information of two traditional
protocols (cine and LGE), which take up more than 9.6 min, but also allows
adjustment of TI in retrospect and yields lower artifact level with similar
image quality.
Squamous cell carcinomas (SCC) frequently have an exceptionally high mutational burden. As consequence, they rapidly develop resistance to platinum-based chemotherapy and overall survival is limited. Novel therapeutic strategies are therefore urgently required. SCC express ∆Np63, which regulates the Fanconi Anemia (FA) DNA-damage response in cancer cells, thereby contributing to chemotherapy-resistance. Here we report that the deubiquitylase USP28 is recruited to sites of DNA damage in cisplatin-treated cells. ATR phosphorylates USP28 and increases its enzymatic activity. This phosphorylation event is required to positively regulate the DNA damage repair in SCC by stabilizing ∆Np63. Knock-down or inhibition of USP28 by a specific inhibitor weakens the ability of SCC to cope with DNA damage during platin-based chemotherapy. Hence, our study presents a novel mechanism by which ∆Np63 expressing SCC can be targeted to overcome chemotherapy resistance. Limited treatment options and low response rates to chemotherapy are particularly common in patients with squamous cancer. The SCC specific transcription factor ∆Np63 enhances the expression of Fanconi Anemia genes, thereby contributing to recombinational DNA repair and Cisplatin resistance. Targeting the USP28-∆Np63 axis in SCC tones down this DNA damage response pathways, thereby sensitizing SCC cells to cisplatin treatment.