Refine
Is part of the Bibliography
- yes (244)
Year of publication
Document Type
- Journal article (129)
- Doctoral Thesis (113)
- Other (1)
- Preprint (1)
Keywords
- MRI (22)
- NMR-Tomographie (19)
- MRT (16)
- magnetic resonance imaging (13)
- Kernspintomografie (8)
- Herzinfarkt (7)
- Computertomographie (6)
- Quantifizierung (6)
- mri (6)
- Bildgebendes Verfahren (5)
Institute
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (244) (remove)
Sonstige beteiligte Institutionen
- Cheng Lab, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA (1)
- Datenintegrationszentrum Würzburg (DIZ) (1)
- Interdisziplinäre Biomaterial- und Datenbank Würzburg (ibdw) (1)
- Würzburg Fabry Center for Interdisciplinary Therapy (FAZIT), University of Würzburg, Würzburg, Germany (1)
Die 31-P-Magnetresonanz-Spektroskopie (31-P-MRS) ist eine nicht-invasive Methode, welche einen direkten Einblick in den Phospholipid-Haushalt der menschlichen Leber erlaubt. Mit der 31-P-MR-Spektroskopie wurden Spektren von 10 Patienten mit Leberzirrhose sowie von 13 gesunden Probanden in Kombination mit dem Lokalisationsverfahren 3D-CSI und dem Nachbearbeitungsprogramm SLOOP (Spectral Localization with Optimal Pointspread Funktion) gewonnen. Die Ergebnisse dieser Studie ergaben signifikante Unterschiede in den Absolutkonzentrationen der Phospholipide zwischen Patienten mit Leberzirrhose und lebergesunden Probanden.
Ultra-high field cardiac MRI in large animals and humans for translational cardiovascular research
(2023)
A key step in translational cardiovascular research is the use of large animal models to better understand normal and abnormal physiology, to test drugs or interventions, or to perform studies which would be considered unethical in human subjects. Ultrahigh field magnetic resonance imaging (UHF-MRI) at 7 T field strength is becoming increasingly available for imaging of the heart and, when compared to clinically established field strengths, promises better image quality and image information content, more precise functional analysis, potentially new image contrasts, and as all in-vivo imaging techniques, a reduction of the number of animals per study because of the possibility to scan every animal repeatedly. We present here a solution to the dual use problem of whole-body UHF-MRI systems, which are typically installed in clinical environments, to both UHF-MRI in large animals and humans. Moreover, we provide evidence that in such a research infrastructure UHF-MRI, and ideally combined with a standard small-bore UHF-MRI system, can contribute to a variety of spatial scales in translational cardiovascular research: from cardiac organoids, Zebra fish and rodent hearts to large animal models such as pigs and humans. We present pilot data from serial CINE, late gadolinium enhancement, and susceptibility weighted UHF-MRI in a myocardial infarction model over eight weeks. In 14 pigs which were delivered from a breeding facility in a national SARS-CoV-2 hotspot, we found no infection in the incoming pigs. Human scanning using CINE and phase contrast flow measurements provided good image quality of the left and right ventricle. Agreement of functional analysis between CINE and phase contrast MRI was excellent. MRI in arrested hearts or excised vascular tissue for MRI-based histologic imaging, structural imaging of myofiber and vascular smooth muscle cell architecture using high-resolution diffusion tensor imaging, and UHF-MRI for monitoring free radicals as a surrogate for MRI of reactive oxygen species in studies of oxidative stress are demonstrated. We conclude that UHF-MRI has the potential to become an important precision imaging modality in translational cardiovascular research.
ZIEL: Die Miktionsurosonographie (MUS) entwickelte sich zu einer alternativen Untersuchungsmethode gegenüber der Miktionszystourethrographie (MCU) in der Diagnostik des vesikoureteralen Refluxes (VUR). Neuentwickelte stabile US-Kontrastmittel führen zu einer Dosis- und Kostenreduktion der MUS, Harmonic Imaging erhöht die Stabilität der US-Kontrastmittel. Diese Studie vergleicht die kontrastverstärkte sonographische Diagnostik des VUR unter Einsatz eines US-Kontrastmittels der 2. Generation [SonoVue®] mit der MCU. Zudem erfolgt ein Vergleich der Ultraschallmodalitäten Fundamental (F), Tissue Harmonic Imaging (THI) und Echo Contrast Imaging (ECI) bezüglich der Darstellbarkeit der Mikrobläschen des US-Kontrastmittels. MATERIAL und METHODEN: Es wurden 40 Patienten mit insgesamt 84 Nieren-Ureter-Einheiten (NUE) untersucht. Zunächst wurde die MUS und anschließend die MCU durchgeführt. Bei der MUS wurde zwischen den 3 Ultraschallmodalitäten F, THI und ECI gewechselt. Der mechanische Index (MI) wurde automatisch jeder Ultraschallmodalität angepasst. Als US-Kontrastmittel wurde SonoVue® eingesetzt, die Dosis betrug 1% des Blasenfüllungsvolumens. MUS und MCU wurden hinsichtlich der Detektionsrate des VUR verglichen. Beim Vergleich von F, THI und ECI wurden ein Ranking und ein Scoring durchgeführt. ERGEBNISSE: Es lag bei 11 Patienten in beiden Untersuchungen ein VUR vor, bei jeweils 3 Patienten konnte nur in einer der beiden Methoden ein Reflux diagnostiziert werden. Beim Vergleich der MUS mit der Standardmethode MCU zeigten sich eine Sensitivität von 85%, eine Spezifität von 92,2%, ein positiver Vorhersagewert (PVW) von 77,3% und ein negativer Vorhersagewert (NVW) von 95,2%. Beim Vergleich von F, THI und ECI zeigte sich ein signifikanter Vorteil von ECI gegenüber F, nicht aber gegenüber THI. Zwischen THI und F gab es keinen signifikanten Unterschied in der Darstellung der Mikrobläschen. SCHLUSSFOLGERUNG: Der Einsatz eines US-Kontrastmittels der 2. Generation (SonoVue®) in der MUS erzielt vergleichbare Ergebnisse in der Diagnostik des VUR wie die MCU. Die Dosisreduktion (1% des Blasenfüllungsvolumens) könnte zu einer Verringerung der Kosten einer MUS führen. Das Harmonic Imaging ermöglicht eine bessere Darstellung der Mikrobläschen im Vergleich zur fundamentalen Bildgebung.
Evaluation von Defekten des triangulären fibrokartilaginären Komplexes (TFCC) und der intrinsischen Bänder des Handgelenkes mit der direkten MR-Arthrographie im Vergleich zur diagnostischen Arthroskopie unter besonderer Berücksichtigung von Partialdefekten. Material und Methoden: 75 direkte MR-Arthrographien des Handgelenkes (intraartikuläre Injektion eines Gemisches aus Gadoliniumchelaten und Iotrolan) wurden von zwei erfahrenen Radiologen im Konsens ausgewertet. Es wurden T1-gewichtete Spin-Echo(SE)-Sequenzen in frontaler und sagittaler sowie Fast low angle shot (FLASH) 3D-Sequenzen in frontaler Schichtung akquiriert. Läsionen des skapholunären Bandes wurden entsprechend den Leitlinien der Deutschen Gesellschaft für Handchirurgie (DGH), Läsionen des lunatotriquetralen Bandes nach Hempfling, Läsionen des TFCC nach Palmer eingeteilt. Anschließend wurden die Befunde mit der Arthroskopie als Referenzstandard korreliert. Ergebnisse: Für die Verletzungen der intrinsischen Bänder und des TFCC waren die Sensitivitäten und Spezifitäten für Komplettrupturen 96% und 99,6% (T1-SE) bzw. 92% und 100% (FLASH 3D), für Partialdefekte 68,1% und 93,3% (T1-SE) bzw. 63% und 96,1% (FLASH 3D). Die T1-SE-Sequenz eignete sich für die Einschätzung skapholunärer Banddefekte besser als die FLASH 3D-Sequenz (p < 0,05). Für Partialdefekte das skapholunären Bandes wurde mit der T1-SE-Sequenz eine Sensitivität von 83,3%, mit der FLASH 3D-Sequenz von 64,7% erreicht. Schlussfolgerung: Die direkte MR-Arthrographie ist bei der Einschätzung von Komplettrupturen der intrinsischen Bänder und des TFCC der diagnostischen Arthroskopie gleichwertig. Mit der T1-SE-Sequenz sind Partialdefekte des skapholunären Bandes im Vergleich zur Arthroskopie mit ausreichender Sicherheit erkennbar. Die T1-SE-Sequenz war hierfür der FLASH 3D-Sequenz überlegen (p < 0,05) und sollte bei der Einschätzung skapholunärer Partialdefekte bevorzugt werden. Die Einschätzung des lunatotriquetralen Bandes gelingt nicht zuverlässig.
Bei Patienten mit Morbus Fabry spielt die kardiale MRT eine wesentliche Rolle für die Diagnostik, die Prognose und das Therapiemonitoring. Als Verfahren der Wahl zur Beurteilung einer fokalen myokardialen Fibrose hat sich das Late Gadolinium Enhancement (LGE) etabliert. Eine diffuse myokardiale Fibrosierung kann mittels LGE-Technik nicht suffizient abgebildet werden, da keine ausreichenden Unterschiede in der Signalintensität bestehen.
Daher könnte das sog. post-KM T1-Mapping eine interessante Alternative sein. Bei diesem Verfahren lassen die T1-Relaxationszeiten Rückschlüsse auf diffuse fibrotische Veränderungen des Myokards zu.
In der vorliegenden Arbeit wurden 43 Fabry-Patienten (20 LGE-positiv und 23 LGE-negativ) im MRT untersucht. Hierzu wurde eine modifizierte Look-Locker Inversion-Recovery (MOLLI)-Sequenz zur Messung der T1-Maps verwendet.
Ziel war es, durch das T1-Mapping Risikopatienten (u.a. LGE-negative Patienten) früher als bisher zu identifizieren und damit zeitnah einer entsprechenden Therapie zuzuführen.
Die Ergebnisse zeigten, dass LGE-positive Fabry-Patienten eine fortgeschrittenere diffuse Myokardfibrose im visuell gesunden Myokard aufweisen als LGE-negative Patienten. Eine Unterscheidung anhand der T1-Zeiten zwischen LGE-negativen Patienten und gesunden Probanden war nicht möglich. Somit kann das T1-Mapping nicht als diagnostische Methode zur Früherkennung einer diffusen Myokardfibrose bei Fabry-Patienten eingesetzt werden.
Des Weiteren konnte gezeigt werden, dass die T1-Zeit im linksventrikulären Myokard bei Fabry-Patienten mit eingeschränkter Nierenfunktion kürzer war als bei Patienten mit normaler Nierenfunktion, unabhängig vom Vorliegen einer fokalen Fibrose. Hingegen konnte im linksventrikulären Blut bei abnehmender glomerulärer Filtrationsrate (GFR) keine kürzere T1-Zeit festgestellt werden als bei normaler GFR.
Außerdem waren die T1-Relaxationszeiten bei LGE-negativen, weiblichen Fabry-Patienten kürzer als bei männlichen Patienten ohne LGE. Eine abschließende Erklärung konnte hierfür nicht gefunden werden.
T1-Mapping wird bislang noch nicht in der Routinediagnostik bei Morbus Fabry eingesetzt. Allerdings steigt dessen Bedeutung im Rahmen von Studien. Weitere Forschungsbemühungen sind notwendig, um geeignete Referenzwerte festzulegen und den Einfluss weiterer Faktoren auf die Fibrosierung des Myokards besser einschätzen zu können.
Objective
Multipartite epicondyles may mimic fractures in the setting of pediatric elbow trauma. This study examines the prevalence of multipartite epicondyles during skeletal development and their association with pediatric elbow fractures.
Materials and methods
In this retrospective analysis, 4282 elbow radiographs of 1265 elbows of 1210 patients aged 0–17 years were reviewed. The radiographs were analyzed by two radiologists in consensus reading, and the number of visible portions of the medial and lateral epicondyles was noted. For elbows in which epicondylar ossification was not yet visible, the epicondyles were already fused with the humerus or could not be sufficiently evaluated due to projection issues or because osteosynthesis material was excluded. In total, 187 elbows were included for the lateral and 715 for the medial epicondyle analyses.
Results
No multipartite medial epicondyles were found in patients without history of elbow fracture, whereas 9% of these patients had multipartite lateral epicondyles (p < 0.01). Current or previous elbow fractures increased the prevalence of multipartite epicondyles, with significant lateral predominance (medial epicondyle + 9% vs. lateral + 24%, p < 0.0001). Including all patients regardless of a history of elbow fracture, multipartite medial epicondyles were observed in 3% and multipartite lateral epicondyles in 18% (p < 0.0001). There was no gender difference in the prevalence of multipartition of either epicondyle, regardless of a trauma history.
Conclusion
Multipartite medial epicondyles occur in patients with current or previous elbow fractures only, whereas multipartite lateral epicondyles may be constitutional. Elbow fractures increase the prevalence of multipartite epicondyles on both sides, with significant lateral predominance.
Key Points
• Multipartite medial epicondyles should be considered of traumatic origin.
• Multipartite lateral epicondyles may be constitutional.
• Elbow fractures increase the prevalence of multipartite epicondyles on both sides with lateral predominance.
Es wurde die diagnostische Genauigkeit fünf verschiedener Rekonstruktionsalgorithmen der DE-CTA der Becken-Bein-Gefäße von Patienten mit pAVK an einem Dual-Source CT mit dem diagnostischen Goldstandard der DSA verglichen. Die DE-CTA zeigte eine exzellente Sensitivität an Becken- und Beingefäßen hinsichtlich einer korrekten Stenosegraduierung, unabhängig von der Rekonstruktion. Die Standard MPR zeigte insgesamt die besten Ergebnisse und ist deshalb vor allem in nicht eindeutigen Fällen die Methode der Wahl. Die Auswertung von DE-CS MPRs, DE-CS MIPs, gekrümmten MPRs oder die semi-automatische quantitative Stenosegradauswertung bringt keinen Zugewinn an diagnostischer Performance im Vergleich zur visuellen Auswertung der Standard MPR. Das Ausmaß der Gefäßwandverkalkungen und die intraluminale Kontrastierung hatten keinen signifikanten Effekt auf die Sensitivität zur Erkennung signifikanter Stenosen an den Becken- und Beingefäßen. Jedoch verschlechterten sich die Spezifität und die Genauigkeit der Rekonstruktionen, welche auf der DE-Knochen- und DE-Plaqueentfernung basieren, signifikant in stark verkalkten oder nur schwach kontrastierten Gefäßsegmenten. Beim Auswerten von DE-CS Rekonstruktionen ist infolgedessen vor allem in schlecht kontrastierten oder stark verkalkten Gefäßen eine weitere Verifizierung des Befundes nötig, um unnötige invasive DSAs als Folge von falsch positiven CTA-Befunden zu reduzieren.
Darmsonographie bei Kindern – Vergleich von fundamentaler und harmonischer Bildgebung. Ziel: Die harmonische Bildgebung (Harmonic Imaging, HI) wurde eingeführt, um für übergewichtige Erwachsene die Ultraschall-Untersuchung zu verbessern. Inwiefern sie auch für Kinder von Vorteil ist, die aufgrund ihrer physikalischen Eigenschaften bessere Untersuchungsbedingungen als Erwachsene bieten, ist bisher nur wenig untersucht worden. Die vorliegende Arbeit beschäftigt sich mit der Frage, ob mit HI bei der Darmsonographie von Kindern eine Verbesserung gegenüber Fundamental Imaging (FI) eintritt. Material und Methode: Bei 90 Kindern (w:m=46:44) wurden mit einem linearen 7,5MHz- Schallkopf jeweils vier Bildpaare des Darms in fundamentaler und harmonischer Bildgebung (THI- Sonoline Elegra®, Siemens) angefertigt. Die Bilder wurden anhand einer zehnstufigen Skala evaluiert. Zudem wurde der Einfluss von Alter, Geschlecht und BMI-FAP auf die Darstellbarkeit des Darms untersucht und darauf geachtet, ob Darmpathologien wie Wandverdickung und Dilatation vorliegen. Ergebnisse: Bei 17 Patienten wurde jeweils ein Bildpaar ausgeschlossen. Die harmonische Bildgebung war der fundamentalen Bildgebung in allen untersuchten Parametern signifikant überlegen (p<0,001). HI war bei 90 Patienten bei der Wand des Darms 81-mal, beim Lumen des Darms 85-mal und bei der Bildqualität 85-mal FI überlegen. Bei 19 der Kinder wurden Darmpathologien detektiert (15x Dilatation, 2x Wandverdickung und 2x Dilatation+Wandverdickung). Es besteht eine inverse Korrelation zwischen dem BMI-FAP und der Darstellbarkeit des Lumens bzw. der Bildqualität, unabhängig von der verwendeten Methode. Schlussfolgerungen: Bei der Sonographie des Darms im Kindesalter zeigt sich die harmonische Bildgebung der fundamentalen Bildgebung signifikant überlegen. Es sollte daher bei Fragestellungen, die den Darm betreffen, auch in der Pädiatrie bevorzugt Harmonic Imaging angewendet werden.
Obwohl der klinische Stellenwert der MRT in zahlreichen Studien für verschiedene Entitäten (AC-Komplex, coracoidale Pathologien, Rotatorenmanschette, Pathologien des Kapsel-Band-Apparates und der Bicepssehne sowie primär und reaktiv bedingte entzündliche Veränderungen) belegt ist, überrascht es, dass in der Literatur keine Arbeiten darüber existieren, inwieweit das Ergebnis der MRT-Untersuchung tatsächlich das therapeutische Procedere beeinflusst. Vorliegende Arbeit untersuchte daher den diagnostischen Impact der MRT im Setting einer hochspezialisierten Schultersprechstunde.
Durch Weiterentwicklungen der MR-Technologie hat die diffusionsgewichtete MRT in der Bildgebung des Abdomens zunehmend an Bedeutung gewonnen. Einige wenige Studien zeigten bereits vielversprechende Ergebnisse für den Einsatz der DWI in der Diagnostik und Verlaufsbeurteilung des Morbus Crohn.
Ziel dieser Arbeit war es, zu untersuchen, ob die DWI zur Detektion entzündlicher Darmwandläsionen und extraluminaler Komplikationen bei pädiatrischen Patienten mit Morbus Crohn ebenso geeignet ist wie die kontrastmittelverstärkte MRT.
Hierzu wurden retrospektiv die klinischen und MR-tomographischen Daten von 48 Kindern, Jugendlichen und jungen Erwachsenen mit Morbus Crohn sowie von 42 Kontrollpatienten ausgewertet, bei denen im Zeitraum zwischen Juli 2008 und Mai 2013 eine MRT-Untersuchung durchgeführt wurde. Aktuelle Befunde einer Ileokoloskopie waren als Referenz bei 60% der Morbus Crohn Patienten und bei etwa einem Drittel der Patienten der Kontrollgruppe vorhanden.
Das Bestehen eines Morbus Crohn konnte bei 47 der insgesamt 48 Patienten anhand der diffusionsgewichteten Sequenzen und in 46 Fällen mittels der kontrastverstärkten T1w-Aufnahmen korrekt nachgewiesen werden. Extramurale Komplikationen wie Abszesse oder Fisteln konnten sowohl mittels DWI als auch durch die KM-MRT detektiert werden. Da die DWI weder eine intravenöse Kontrastmittelapplikation noch Atemanhaltetechniken erfordert, ist sie gerade bei pädiatrischen Patienten ein geeignetes Bildgebungsverfahren. Wegen der relativ geringen Ortsauflösung der diffusionsgewichteten Sequenzen sollte jedoch zusätzlich eine Standardsequenz, wie die T2-gewichtete HASTE-Sequenz, akquiriert werden.
Nach den Ergebnissen dieser Studie ist die diffusionsgewichtete MRT zur Beurteilung der entzündlichen Veränderungen des Morbus Crohn sehr gut geeignet und besitzt das Potenzial, nicht nur ergänzend, sondern als Alternative zur KM-MRT zum Einsatz zu kommen.
Background
Partial segmental thrombosis of the corpus cavernosum (PSTCC) is a rare disease predominantly occurring in young men. Cardinal symptoms are pain and perineal swelling. Although several risk factors are described in the literature, the exact etiology of penile thrombosis remains unclear in most cases. MRI or ultrasound (US) is usually used for diagnosing this condition.
Case presentation
We report a case of penile thrombosis after left-sided varicocele ligature in a young patient. The diagnosis was established using contrast-enhanced ultrasound (CEUS) and was confirmed by contrast-enhanced magnetic resonance imaging (ceMRI). Successful conservative treatment consisted of systemic anticoagulation using low molecular weight heparin and acetylsalicylic acid.
Conclusion
PSTCC is a rare condition in young men and appears with massive pain and perineal swelling. In case of suspected PSTCC utilization of CEUS may be of diagnostic benefit.
Background:
Diffusion-weighted MRI has been proposed as a new technique for imaging synovitis without intravenous contrast application. We investigated diagnostic utility of multi-shot readout-segmented diffusion-weighted MRI (multi-shot DWI) for synovial imaging of the knee joint in patients with juvenile idiopathic arthritis (JIA).
Methods:
Thirty-two consecutive patients with confirmed or suspected JIA (21 girls, median age 13 years) underwent routine 1.5 T MRI with contrast-enhanced T1w imaging (contrast-enhanced MRI) and with multi-shot DWI (RESOLVE, b-values 0–50 and 800 s/mm\(^2\)). Contrast-enhanced MRI, representing the diagnostic standard, and diffusion-weighted images at b = 800 s/mm\(^2\) were separately rated by three independent blinded readers at different levels of expertise for the presence and the degree of synovitis on a modified 5-item Likert scale along with the level of subjective diagnostic confidence.
Results:
Fourteen (44%) patients had active synovitis and joint effusion, nine (28%) patients showed mild synovial enhancement not qualifying for arthritis and another nine (28%) patients had no synovial signal alterations on contrast-enhanced imaging. Ratings by the 1st reader on contrast-enhanced MRI and on DWI showed substantial agreement (κ = 0.74). Inter-observer-agreement was high for diagnosing, or ruling out, active arthritis of the knee joint on contrast-enhanced MRI and on DWI, showing full agreement between 1st and 2nd reader and disagreement in one case (3%) between 1st and 3rd reader. In contrast, ratings in cases of absent vs. little synovial inflammation were markedly inconsistent on DWI. Diagnostic confidence was lower on DWI, compared to contrast-enhanced imaging.
Conclusion:
Multi-shot DWI of the knee joint is feasible in routine imaging and reliably diagnoses, or rules out, active arthritis of the knee joint in paediatric patients without the need of gadolinium-based i.v. contrast injection. Possibly due to “T2w shine-through” artifacts, DWI does not reliably differentiate non-inflamed joints from knee joints with mild synovial irritation.
Scannereigene akustische Aktivierung - Eine neue Pulssequenz vereinfacht fMRT des auditiven Kortex
(2007)
Echo-planar Imaging (EPI) erzeugt durch schnell wechselnde Gradienten beträchtliche Schallemissionen. Dies führt nachgewiesenermaßen bei funktionellen Magnet-Resonanz-Tomographie- (fMRT-) Studien zu einer Aktivierung des auditiven Systems, insofern dieses beim jeweiligen Probanden in der Lage ist zu reagieren. Sowohl für auditive wie auch für nicht-auditive Untersuchungen wurden verschiedenste Anstrengungen unternommen, diese Interferenzen zu minimieren. Anstatt den Lärm des Scanners zu reduzieren oder die Transmission des Schalls zu behindern, war es nun das Ziel, eben diesen Schall zur Aktivierung des auditiven Kortex zu benutzen und diese mit fMRT-Untersuchungen nachzuweisen. Dieses geschieht schlicht durch das Auslassen von Read-Outs aus der Gradientenfolge der Pulssequenz. Diese Pulse sind die Hauptemissionsquellen von Schall des EPI, sie verursachen sowohl den Spitzenschallpegel als auch die Grundfrequenz, welche im umgekehrten Verhältnis zum Echo-Spacing steht. Durch eine Modell-gestützte Analyse wird gezeigt, dass das Auslassen von Read-Outs nach einem vordefinierten Schema verlässlich dazu geeignet ist, eine hämodynamische Blood-Oxygenation-Level-Dependent- (BOLD-) Signalveränderung im auditiven Kortex von normal hörenden Probanden (n=60) zu evozieren. Um den Nutzen der Technik beim auditiven fMRI zu zeigen, werden auf der Ebene der Einzelanalysen das traditionelle Family-Wise-Error-Rate- (FWER-) korrigierte Maximum Height Thresholding mit dem Spatial Mixture Modelling (SMM) verglichen. Mit Letzterem können so in 95 % der Fälle eine adäquate, bilaterale, auditive Aktivierung nachwiesen werden, wohingegen das FWER-basierte Voxel-Thresholding nur in 72 % aller Probanden eine solche Aktivierung zeigt. Um die klinische Anwendbarkeit der Technik unter pathologischen Bedingungen zu demonstrieren, wird ein Fallbericht einer Patientin vorgestellt, die an einem schweren, beidseitigen Sensorineural Hearing Loss (SNHL) aufgrund bilateraler Large Vestibular Aqueducts (LVAs) leidet. Dabei wird eben diese Modifikation benutzt, um präoperativ vor Cochlear Implantation (CI) zu zeigen, dass ein zentrales Resthörvermögen vorhanden ist. Da die Untersuchung völlig unabhängig von der Compliance des Patienten und kein zusätzliches Zubehör zum Scanner vonnöten sind, eignet sie sich hervorragend zu auditiven Untersuchungen, um so schnell das Hörvermögen zu prüfen. Dabei funktioniert die Methode unabhängig von äußerlichen Bedingungen: Bei hörgesunden Probanden ebenso wie bei Hörgeschädigten, bei Kindern, Jugendlichen und Erwachsenen aller Altersstufen sowie unabhängig von einer Sedierung während der Untersuchung. Beide benutzten Scanner zeigten unabhängig vom Gradienten oder der verwendeten Spule ein gleiches Ergebnis.
Die diffusionsgewichtete Magnetresonanztomographie (DW-MRT) ist ein fester Bestandteil der radiologischen Diagnostik des Zentralnervensystems (ZNS), und zwar nicht nur bei Schlaganfällen sondern zunehmend auch bei Hirntumoren, Schädelhirntraumata, demyelinisierenden, degenerativen sowie entzündlichen Erkrankungen. Diese Pathologien gehen in der Regel mit einer Veränderung der lokalen Diffusionsbedingungen einher, die eine reguläre Diffusionsbildgebung beeinträchtigen. Durch die Bestimmung der Diffusionsparameter lassen sich mit Hilfe verschiedener mathematischer Verfahren Faserverbindungen visualisieren. Wie sich diese unterschiedlichen Methoden in Regionen mit aversiven Diffusionsbedingungen verhalten, konnte mit der Arbeit erstmals systematisch gezeigt werden. Hierzu wurden 29 Patientenuntersuchungen ausgewertet. Als Einschlusskriterium galt eine unilaterale, diffusionsrelevante Läsion mit Bezug zur Pyramidenbahn. Ausschlusskriterium war eine vollständige Hemiparese als Zeichen einer vollständigen Zerstörung der relevanten Leitungsbahn. Im Einzelnen handelte es sich bei den untersuchten Läsionen um drei höhergradige Astrozytome (WHO Grad III-IV), drei niedriggradige Astrozytome, acht Glioblastome, zwei Karzinommetastasen, zwei arteriovenöse Malformationen und je eine entzündliche Parasitose, ein Oligodendrogliom, eine Gliomatose und ein Kavernom. Untersucht wurden zwei deterministische (einfaches und interpoliertes streamlining) und drei probabilistische Methoden (ohne crossing fibers; mit Berechnung von zwei Fasern pro Voxel und constrained/bayesian). Läsionen jeglicher Art verursachten signifikant mehr Fehlschläge bei deterministischer als bei probabilistischer Traktographie. In neun Untersuchungen bei einfacher und in acht Untersuchungen bei interpolierter Traktographie zeigten sich fasch negative Ergebnisse. Probabilistisches Traktographieren eliminiert nicht falsch negative Ergebnisse, reduziert sie jedoch unter den oben genannten aversiven Difussivitätsbedingungen mit denen intraaxiale Läsionen einhergehen. Klinisches Wissen über die verbliebene Traktintegrität ermöglicht die Umwandlung der Traktographieergebnisse in Wahrscheinlichkeitswerte innerhalb eines Bayschen Modells. Außerdem ist nur unter Miteinbeziehung klinischer Informationen eine Traktographie nach dem constrained Modell möglich. Obwohl die probabilistische Traktographie weniger anfällig für falsch negative Ergebnisse ist als die deterministische, geht die erhöhte Sensitivität der Algorithmen auf Kosten der Spezifität. Dies zeigt sich in signifikant erhöhten bilateralen Traktvolumina und einem übermäßigen Unterschied der Traktvolumina von Läsionsseite zu kontralateraler Seite. Die probabilistisch, unconstrained durchgeführte Traktographie der Pyramidenbahn zeigte eine signifikant, durch die Läsion verursachte Volumenminderung des Traktes, während dies im constrained modellierten Fall durch die Daten nicht gezeigt werden konnte. Dies zeigt die Robustheit des Constrained Modells unter den aversiven klinischen Bedingungen einer intraaxialen Läsion ohne den Nachteil von erhöhten Fehltraktographien. Es kann konstatiert werden, dass sich die deterministischen Traktographieverfahren zur präoperativen Orientierung vor neurochirurgischen Eingriffen eignen. Jedoch ist eine nicht zu unterschätzende Anzahl von falsch negativen Ergebnissen zu berücksichtigen. In zweifelhaften Fällen sollte zusätzlich eine Darstellung mittels probabilistischen Algorithmen, am besten mittels Constrained Modell durchgeführt werden.
In unserer Studie kamen die neuen Verfahren qualitative und semiquantitative Elastographie zum Einsatz. Es sollte gezeigt werden, ob sie als Ergänzung zu den herkömmlichen sonographischen Verfahren die Diagnosestellung von Erkrankungen am Hals bei Kindern und Jugendlichen verbessern können.
Bei der Untersuchung mittels semiquantitativer Elastographie konnten wir in unserer Studie beim Vergleich Schilddrüsen-Normalbefund und Hashimoto-Thyreoiditis einen signifikanten Unterschied der Scherwellengeschwindigkeiten nachweisen. Es zeigte sich, dass Patienten mit Hashimoto-Thyreoiditis signifikant höhere Scherwellengeschwindigkeiten aufweisen als Patienten mit Normalbefund. Für die anderen untersuchten Schilddrüsenerkrankungen, Struma diffusa und Struma nodosa und für die Erkrankungen der Lymphknoten, benigne Veränderung/Entzündung, maligne Veränderung und Abszess, ließ sich kein signifikanter Unterschied feststellen.
Die Sensitivität und Spezifität konnte durch Einsatz des neuen Verfahrens der qualitativen Elastographie nicht gesteigert werden. Während sich bei der Schilddrüsendiagnostik geringere Werte für Sensitivität und Spezifität im Vergleich zu den herkömmlichen Verfahren zeigten, unterschieden sich die Werte bei der Lymphknotenuntersuchung Reader-abhängig.
Bei der Schilddrüsenuntersuchung lag die Bildqualität der konventionellen Sonographie über der der qualitativen Elastographie. Dagegen wurde bei der Lymphknotenuntersuchung die Bildqualität der Elastographiebilder höher bewertet als jene der herkömmlichen Verfahren.
Insgesamt konnte in unserer Studie gezeigt werden, dass Patienten mit Hashimoto-Thyreoiditits signifikant höhere Scherwellengeschwindigkeiten im Schilddrüsengewebe aufweisen, als bei Normalbefund. In der Diagnostik von Schilddrüsen- und Lymphknotenerkrankungen konnte bezüglich des neuen Verfahrens der qualitativen Elastographie eine Überlegenheit gegenüber der konventionellen Sonographie nicht nachgewiesen werden.
Um die Ergebnisse unserer Studie abschließend bewerten zu können, wäre eine Validierung anhand einer größeren Patientengruppe nötig.
Background
Skeletal muscle function dysfunction has been reported in patients with cystic fibrosis (CF). Studies so far showed inconclusive data whether reduced exercise capacity is related to intrinsic muscle dysfunction in CF.
Methods
Twenty patients with CF and 23 age-matched controls completed an incremental cardiopulmonary cycling test. Further, a Wingate anaerobic test to assess muscle power was performed. In addition, all participants completed an incremental knee-extension test with 31P magnetic resonance spectroscopy to assess muscle metabolism (inorganic phosphate (Pi) and phosphocreatinine (PCr) as well as intracellular pH). In the MRI, muscle cross-sectional area of the M. quadriceps (qCSA) was also measured. A subgroup of 15 participants (5 CF, 10 control) additionally completed a continuous high-intensity, high-frequency knee-extension exercise task during 31P magnetic resonance spectroscopy to assess muscle metabolism.
Results
Patients with CF showed a reduced exercise capacity in the incremental cardiopulmonary cycling test (VO2peak: CF 77.8 ± 16.2%predicted (36.5 ± 7.4 ml/qCSA/min), control 100.6 ± 18.8%predicted (49.1 ± 11.4 ml/qCSA/min); p < 0.001), and deficits in anaerobic capacity reflected by the Wingate test (peak power: CF 537 ± 180 W, control 727 ± 186 W; mean power: CF 378 ± 127 W, control 486 ± 126 W; power drop CF 12 ± 5 W, control 8 ± 4 W. all: p < 0.001). In the knee-extension task, patients with CF achieved a significantly lower workload (p < 0.05). However, in a linear model analysing maximal work load of the incremental knee-extension task and results of the Wingate test, respectively, only muscle size and height, but not disease status (CF or not) contributed to explaining variance. In line with this finding, no differences were found in muscle metabolism reflected by intracellular pH and the ratio of Pi/PCr at submaximal stages and peak exercise measured through MRI spectroscopy.
Conclusions
The lower absolute muscle power in patients with CF compared to controls is exclusively explained by the reduced muscle size in this study. No evidence was found for an intrinsic skeletal muscle dysfunction due to primary alterations of muscle metabolism.
ZIEL: In den letzten Jahren ist die kontrastverstärkte sonographische Refluxprüfung, d.h. die Miktionsurosonographie (MUS), zunehmend zu einer Alternative gegenüber der standardmäßig eingesetzten Miktions-zysturethrographie (MCU) für die Diagnostik des vesikoureteralen Reflux (VUR) geworden. Eine der Einschränkungen sind jedoch die sehr hohen Kosten des Ultraschallkontrastmittels. Durch Entwicklung von neuen Ultraschallkontrastmitteln erhofft man sich aufgrund vergleichbarer Bildqualität in deutlich niedrigerer Dosis entsprechend eine Reduktion der Kosten zu erreichen. Thema dieser Studie ist eines dieser neuen Ultraschallkontrastmittel (SonoVue®) mit dem in der Routine verwendeten US-Kontrastmittel Levovist® in-vitro unter Betrachtung der für die Refluxdiagnostik relevanten physikalisch-chemischen Eigenschaften zu vergleichen. MATERIAL UND METHODEN: Der in-vitro Versuchsaufbau simulierte die in-vivo durchgeführte MUS. Verwendet wurden die Abbildungsmodalitäten Fundamental und Harmonic Imaging (THI/ECI, Sonoline Elegra®, Siemens), letztere sowohl mit einem niedrigen als auch mit einem hohen Mechanical Index (MI). SonoVue® wurde in einer Konzentration von 0,25%, 0,5% und 1%, Levovist in einer Konzentration von 5% bezogen auf ein Gesamtvolumen in-vitro von 20ml getestet. Als Vergleichsparameter diente die in-vitro Kontrastdauer. Diese wurde definiert als der Zeitraum vom Beginn der Messung bis zu dem Zeitpunkt, an dem auf mehr als 50% der Bildfläche keine echogenen Mikrobläschen mehr nachweisbar waren. ERGEBNISSE: Die Änderung der oben genannten Konzentrationen hatte keinen entscheidenden Einfluss auf die Kontrastdauer von SonoVue®. Darüber hinaus konnte beim Umschalten von THI low MI auf THI high MI die Kontrastdauer von SonoVue® signifikant verlängert werden. Betrachtet man die Abbildungsmodalität THI mit hohem MI, welche routinemäßig bei Levovist® angewendet wird, so zeigte sich, dass die Kontrastdauer bei Levovist® in einer Konzentration von 5% bei 1,1 Minuten lag, bei SonoVue® hingegen erhielten wir bei einer Konzentration von 1% eine Kontrastdauer von 7,3 Minuten. Dies bedeutet, dass trotz Verwendung einer fünffach geringeren Dosis bei SonoVue® sich die Kontrastdauer in-vitro um mehr als 80% verlängerte. Darüber hinaus blieb die Kontrastdauer von SonoVue® über einen Zeitraum von 6 Stunden weitestgehend stabil, während bei Levovist® die Kontrastdauer schon nach 0,5 Stunden eine deutliche Reduktion zeigte. SCHLUSSFOLGERUNG: Es ist zu erwarten, dass SonoVue® auch bei intravesicalen Applikationen in einer deutlich niedrigeren Dosis (1% des Blasenvolumens) verwendet werden kann und dass mehrere Untersuchungen über einen längeren Zeitraum mit einer Flasche SonoVue® durchgeführt werden können. Somit würde eine Kostenreduktion erreicht werden.
This longitudinal study was performed to evaluate the feasibility of detecting the interaction between wall shear stress (WSS) and plaque development. 20 ApoE\(^{-/-}\)mice were separated in 12 mice with Western Diet and 8 mice with Chow Diet. Magnetic resonance (MR) scans at 17.6 Tesla and histological analysis were performed after one week, eight and twelve weeks. Allin vivoMR measurements were acquired using a flow sensitive phase contrast method for determining vectorial flow. Histological sections were stained with Hematoxylin and Eosin, Elastica van Gieson and CD68 staining. Data analysis was performed using Ensight and a Matlab-based "Flow Tool". The body weight of ApoE\(^{-/-}\)mice increased significantly over 12 weeks. WSS values increased in the Western Diet group over the time period; in contrast, in the Chow Diet group the values decreased from the first to the second measurement point. Western Diet mice showed small plaque formations with elastin fragmentations after 8 weeks and big plaque formations after 12 weeks; Chow Diet mice showed a few elastin fragmentations after 8 weeks and small plaque formations after 12 weeks. Favored by high-fat diet, plaque formation results in higher values of WSS. With wall shear stress being a known predictor for atherosclerotic plaque development, ultra highfield MRI can serve as a tool for studying the causes and beginnings of atherosclerosis.
In summary, the wave-CAIPI k-space trajectory presents an efficient sampling strategy for accelerated MR acquisitions. Using wave-CAIPI in parallel imaging reconstructions leads to a reduced noise level in the reconstructed images, compared to the Cartesian standard trajectory. This effect could be quantified by means of noise and SNR calculations. An SNR gain can be traded for a reduced scan time, i.e., additional undersampling, or for an enhanced image quality, keeping scan time constant.
Acceleration of MR imaging is especially important in dynamic applications, since these examinations are inherently time-consuming. The impact of wave-CAIPI sampling on image quality and its potential for scan time reduction was investigated for two dynamic applications: self-gated dynamic 3D lung MRI during free breathing and cardiac 4D flow MRI.
Dynamic 3D Lung MRI
By employing wave-CAIPI sampling in self-gated, free-breathing dynamic 3D lung MRI for the purpose of radiotherapy treatment planning, the image quality of accelerated scans could be enhanced. Volunteer examinations were used to quantify image quality by means of similarity between accelerated and reference images. To this end, the normalized mutual information and the root-mean-square error were chosen as quantitative image similarity measures.
The wave-CAIPI sampling was shown to exhibit superior quality, especially for short scan times. The values of the normalized mutual information were (10.2 +- 7.3)% higher in the wave-CAIPI case -- the root-mean-square error was (18.9 +- 13.2)% lower on average. SNR calculations suggest an average SNR benefit of around 14% for the wave-CAIPI, compared to Cartesian sampling.
Resolution of the lung in 8 breathing states can be achieved in only 2 minutes. By using the wave-CAIPI k-space trajectory, precise tumor delineation and assessment of respiration-induced displacement is facilitated.
Cardiac 4D Flow MRI
In 4D flow MRI, acceleration of the image acquisition is essential to incorporate the corresponding scan protocols into clinical routine. In this work, a retrospective 6-fold acceleration of the image acquisition was realized. Cartesian and wave-CAIPI 4D flow examinations of healthy volunteers were used to quantify uncertainties in flow parameters for the respective sampling schemes.
By employing wave-CAIPI sampling, the estimated errors in flow parameters in 6-fold accelerated scans could be reduced by up to 55%. Noise calculations showed that the noise level in 6-fold accelerated 4D flow acquisitions with wave-CAIPI is 43% lower, compared to Cartesian sampling. Comparisons between Cartesian and wave-CAIPI 4D flow examinations with a prospective acceleration factor R=2 revealed small, but partly statistically significant discrepancies. Differences between 2-fold and 6-fold accelerated wave-CAIPI scans are comparable to the differences between Cartesian and wave-CAIPI examinations at R=2.
Wave-CAIPI 4D flow acquisitions of the aorta could be performed with an average, simulated scan time of under 4 minutes, with reduced uncertainties in flow parameters. Important visualizations of hemodynamic flow patterns in the aorta were only slightly affected by undersampling in the wave-CAIPI case, whereas for Cartesian sampling, considerable discrepancies were observed.
Purpose
The aim of this study was to compare the wave‐CAIPI (controlled aliasing in parallel imaging) trajectory to the Cartesian sampling for accelerated free‐breathing 4D lung MRI.
Methods
The wave‐CAIPI k‐space trajectory was implemented in a respiratory self‐gated 3D spoiled gradient echo pulse sequence. Trajectory correction applying the gradient system transfer function was used, and images were reconstructed using an iterative conjugate gradient SENSE (CG SENSE) algorithm. Five healthy volunteers and one patient with squamous cell carcinoma in the lung were examined on a clinical 3T scanner, using both sampling schemes. For quantitative comparison of wave‐CAIPI and standard Cartesian imaging, the normalized mutual information and the RMS error between retrospectively accelerated acquisitions and their respective references were calculated. The SNR ratios were investigated in a phantom study.
Results
The obtained normalized mutual information values indicate a lower information loss due to acceleration for the wave‐CAIPI approach. Average normalized mutual information values of the wave‐CAIPI acquisitions were 10% higher, compared with Cartesian sampling. Furthermore, the RMS error of the wave‐CAIPI technique was lower by 19% and the SNR was higher by 14%. Especially for short acquisition times (down to 1 minute), the undersampled Cartesian images showed an increased artifact level, compared with wave‐CAIPI.
Conclusion
The application of the wave‐CAIPI technique to 4D lung MRI reduces undersampling artifacts, in comparison to a Cartesian acquisition of the same scan time. The benefit of wave‐CAIPI sampling can therefore be traded for shorter examinations, or enhancing image quality of undersampled 4D lung acquisitions, keeping the scan time constant.