Refine
Has Fulltext
- yes (19)
Is part of the Bibliography
- yes (19)
Year of publication
Document Type
- Journal article (19)
Language
- English (19)
Keywords
- athletes (3)
- SWOT (2)
- adolescents (2)
- aerobic fitness (2)
- biofeedback (2)
- blood flow (2)
- body composition (2)
- children (2)
- clothing (2)
- functional training (2)
Institute
The present study was designed to assess the psycho-physiological responses of physically untrained individuals to mobile-based multi-stimulating, circuit-like, multiple-joint conditioning (Circuit\(_{HIIT}\)) performed either once (1xCircuitHIIT) or twice (2xCircuit\(_{HIIT}\)) daily for 4 weeks. In this single-center, two-arm randomized, controlled study, 24 men and women (age: 25 ± 5 years) first received no training instructions for 4 weeks and then performed 4 weeks of either 1xCircuitHIIT or 2xCircuit\(_{HIIT}\) (5 men and 7 women in each group) daily. The 1xCircuitHIIT and 2xCircuit\(_{HIIT}\) participants carried out 90.7 and 85.7% of all planned training sessions, respectively, with average heart rates during the 6-min sessions of 74.3 and 70.8% of maximal heart rate. Body, fat and fat-free mass, and metabolic rate at rest did not differ between the groups or between time-points of measurement. Heart rate while running at 6 km⋅h\(^{-1}\) declined after the intervention in both groups. Submaximal and peak oxygen uptake, the respiratory exchange ratio and heart rate recovery were not altered by either intervention. The maximal numbers of push-ups, leg-levers, burpees, 45°-one-legged squats and 30-s skipping, as well as perception of general health improved in both groups. Our 1xCircuit\(_{HIIT}\) or 2xCircuit\(_{HIIT}\) interventions improved certain parameters of functional strength and certain dimensions of quality of life in young untrained individuals. However, they were not sufficient to enhance cardio-respiratory fitness, in particular peak oxygen uptake.
Background
High-intensity interval training (HIIT) is frequently employed to improve the endurance of various types of athletes. To determine whether youth soccer players may benefit from the intermittent load and time efficiency of HIIT, we performed a meta-analysis of the relevant scientific literature.
Objectives
Our primary objective was to compare changes in various physiological parameters related to the performance of youth soccer players in response to running-based HIIT to the effects of other common training protocols (i.e., small-sided games, technical training and soccer-specific training, or high-volume endurance training). A secondary objective was to compare specifically running-based HIIT to a soccer-specific form of HIIT known as small-sided games (SSG) in this same respect, since this latter type of training is being discussed extensively by coaches.
Method
A systematic search of the PubMed, SPORTDiscus, and Web of Science databases was performed in August of 2017 and updated during the review process in December of 2018. The criteria for inclusion of articles for analysis were as follows: (1) comparison of HIIT to SSG or some other training protocol employing a pre-post design, (2) involvement of healthy young athletes (≤ 18 years old), and (3) assessment of variables related to endurance or soccer performance. Hedges’ g effect size (dppc2) and associated 95% confidence intervals for the comparison of the responses to HIIT and other interventions were calculated.
Results
Nine studies, involving 232 young soccer players (mean age 16.2 ± 1.6 years), were examined. Endurance training in the form of HIIT or SSG produced similar positive effects on most parameters assessed, including peak oxygen uptake and maximal running performance during incremental running (expressed as Vmax or maximal aerobic speed (MAS)), shuttle runs (expressed as the distance covered or time to exhaustion), and time-trials, as well as submaximal variables such as running economy and running velocity at the lactate threshold. HIIT induced a moderate improvement in soccer-related tests involving technical exercises with the soccer ball and other game-specific parameters (i.e., total distance covered, number of sprints, and number of involvements with the ball). Neuromuscular parameters were largely unaffected by HIIT or SSG.
Conclusion
The present meta-analysis indicates that HIIT and SSG have equally beneficial impacts on variables related to the endurance and soccer-specific performance of youth soccer players, but little influence on neuromuscular performance.
Background
Repeated sprint performance is determined by explosive production of power, as well as rapid recovery between successive sprints, and there is evidence that compression garments and sports taping can improve both of these factors.
Methods
In each of two sub-studies, female athletes performed two sets of 30 30-m sprints (one sprint per minute), one set wearing compression garment with adhesive silicone stripes (CGSS) intended to mimic taping and the other with normal clothing, in randomized order. Sub-study 1 (n = 12) focused on cardio-respiratory, metabolic, hemodynamic and perceptual responses, while neuronal and biomechanical parameters were examined in sub-study 2 (n = 12).
Results
In both sub-studies the CGSS improved repeated sprint performance during the final 10 sprints (best P < 0.01, d = 0.61). None of the cardio-respiratory or metabolic variables monitored were altered by wearing this garment (best P = 0.06, d = 0.71). Also during the final 10 sprints, rating of perceived exertion by the upper leg muscles was reduced (P = 0.01, d = 1.1), step length increased (P = 0.01, d = 0.91) and activation of the m. rectus femoris elevated (P = 0.01, d = 1.24), while the hip flexion angle was lowered throughout the protocol (best P < 0.01, d = 2.28) and step frequency (best P = 0.34, d = 0.2) remained unaltered.
Conclusion
Although the physiological parameters monitored were unchanged, the CGSS appears to improve performance during 30 30-m repeated sprints by reducing perceived exertion and altering running technique.
Background
Repeated sprint performance is determined by explosive production of power, as well as rapid recovery between successive sprints, and there is evidence that compression garments and sports taping can improve both of these factors.
Methods
In each of two sub-studies, female athletes performed two sets of 30 30-m sprints (one sprint per minute), one set wearing compression garment with adhesive silicone stripes (CGSS) intended to mimic taping and the other with normal clothing, in randomized order. Sub-study 1 (n = 12) focused on cardio-respiratory, metabolic, hemodynamic and perceptual responses, while neuronal and biomechanical parameters were examined in sub-study 2 (n = 12).
Results
In both sub-studies the CGSS improved repeated sprint performance during the final 10 sprints (best P < 0.01, d = 0.61). None of the cardio-respiratory or metabolic variables monitored were altered by wearing this garment (best P = 0.06, d = 0.71). Also during the final 10 sprints, rating of perceived exertion by the upper leg muscles was reduced (P = 0.01, d = 1.1), step length increased (P = 0.01, d = 0.91) and activation of the m. rectus femoris elevated (P = 0.01, d = 1.24), while the hip flexion angle was lowered throughout the protocol (best P < 0.01, d = 2.28) and step frequency (best P = 0.34, d = 0.2) remained unaltered.
Conclusion
Although the physiological parameters monitored were unchanged, the CGSS appears to improve performance during 30 30-m repeated sprints by reducing perceived exertion and altering running technique.
Athletes adapt their training daily to optimize performance, as well as avoid fatigue, overtraining and other undesirable effects on their health. To optimize training load, each athlete must take his/her own personal objective and subjective characteristics into consideration and an increasing number of wearable technologies (wearables) provide convenient monitoring of various parameters. Accordingly, it is important to help athletes decide which parameters are of primary interest and which wearables can monitor these parameters most effectively. Here, we discuss the wearable technologies available for non-invasive monitoring of various parameters concerning an athlete's training and health. On the basis of these considerations, we suggest directions for future development. Furthermore, we propose that a combination of several wearables is most effective for accessing all relevant parameters, disturbing the athlete as little as possible, and optimizing performance and promoting health.
Objectives
To assess the impact of HIIT performed at school, i.e. both in connection with physical education (intra-PE) and extracurricular sports activities (extra-PE), on the physical fitness and health of children and adolescents.
Methods
PubMed and SPORTDiscus were searched systematically utilizing the following criteria for inclusion: (1) healthy children and adolescents (5–18 years old) of normal weight; (2) HIIT performed intra- and/or extra-PE for at least 5 days at an intensity ≥ 80% of maximal heart rate (HR\(_{max}\)) or peak oxygen uptake (VO\(_{2peak}\)) or as Functional HIIT; (3) comparison with a control (HIIT versus alternative interventions); and (4) pre- and post-analysis of parameters related to physical fitness and health. The outcomes with HIIT and the control interventions were compared utilizing Hedges’ g effect size (ES) and associated 95% confidence intervals.
Results
Eleven studies involving 707 participants who performed intra-PE and 388 participants extra-PE HIIT were included. In comparison with the control interventions, intra-PE HIIT improved mean ES for neuromuscular and anaerobic performance (ES jump performance: 5.89 ± 5.67 (range 1.88–9.90); ES number of push-ups: 6.22 (range n.a.); ES number of sit-ups: 2.66 ± 2.02 (range 1.24–4.09)), as well as ES fasting glucose levels (− 2.68 (range n.a.)) more effectively, with large effect sizes. Extra-PE HIIT improved mean ES for neuromuscular and anaerobic performance (ES jump performance: 1.81 (range n.a.); ES number of sit-ups: 2.60 (range n.a.)) to an even greater extent, again with large effect sizes. Neither form of HIIT was more beneficial for parameters related to cardiorespiratory fitness than the control interventions.
Conclusion
Compared to other forms of exercise (e.g. low-to-moderate-intensity running or walking), both intra- and extra-PE HIIT result in greater improvements in neuromuscular and anaerobic performance, as well as in fasting levels of glucose in school children.
The effects of circuit-like functional high-intensity training (Circuit\(_{HIIT}\)) alone or in combination with high-volume low-intensity exercise (Circuit\(_{combined}\)) on selected cardio-respiratory and metabolic parameters, body composition, functional strength and the quality of life of overweight women were compared. In this single-center, two-armed randomized, controlled study, overweight women performed 9-weeks (3 sessions·wk\(^{−1}\)) of either Circuit\(_{HIIT}\) (n = 11), or Circuit\(_{combined}\) (n = 8). Peak oxygen uptake and perception of physical pain were increased to a greater extent (p < 0.05) by Circuit\(_{HIIT}\), whereas Circuit\(_{combined}\) improved perception of general health more (p < 0.05). Both interventions lowered body mass, body-mass-index, waist-to-hip ratio, fat mass, and enhanced fat-free mass; decreased ratings of perceived exertion during submaximal treadmill running; improved the numbers of push-ups, burpees, one-legged squats, and 30-s skipping performed, as well as the height of counter-movement jumps; and improved physical and social functioning, role of physical limitations, vitality, role of emotional limitations, and mental health to a similar extent (all p < 0.05). Either forms of these multi-stimulating, circuit-like, multiple-joint training can be employed to improve body composition, selected variables of functional strength, and certain dimensions of quality of life in overweight women. However, Circuit\(_{HIIT}\) improves peak oxygen uptake to a greater extent, but with more perception of pain, whereas Circuit\(_{Combined}\) results in better perception of general health.
The purpose of this study was to determine whether an individually designed incremental exercise protocol results in greater rates of oxygen uptake VO\(_{2max}\) than standardized testing. Fourteen well-trained, male runners performed five incremental protocols in randomized order to measure their VO\(_{2max}\): i) an incremental test (INC\(_{S+I}\)) with pre-defined increases in speed (2 min at 8.64 km.h\(^{-1}\), then a rise of 1.44 km.h\(^{-1}\) every 30 s up to 14.4 km.h\(^{-1}\)) and thereafter inclination (0.5.every 30 s); ii) an incremental test (INC\(_{I}\)) at constant speed (14.4 km.h\(^{-1}\)) and increasing inclination (2 degrees every 2 min from the initial 0 degrees); iii) an incremental test (INC\(_{S}\)) at constant inclination (0 degrees) and increasing speed (0.5 km.h\(^{-1}\) every 30 s from the initial 12.0 km.h\(^{-1}\)); iv) a graded exercise protocol (GXP) at a 1 degrees incline with increasing speed (initially 8.64 km.h\(^{-1}\) + 1.44 km.h\(^{-1}\) every 5 min); v) an individual exercise protocol (INDXP) in which the runner chose the inclination and speed. VO\(_{2max}\) was lowest (-4.2%) during the GXP (p = 0.01; d = 0.06 - 0.61) compared to all other tests. The highest rating of perceived exertion, heart rate, ventilation and end-exercise blood lactate concentration were similar between the different protocols (p < 0.05). The time to exhaustion ranged from 7 min 18 sec (INC\(_{S}\)) to 25 min 30 sec (GXP) (p = 0.01). The VO\(_{2max}\) attained by employing an individual treadmill protocol does not differ from the values derived from various standardized incremental protocols.
Here, we evaluated the influence of breathing oxygen at different partial pressures during recovery from exercise on performance at sea-level and a simulated altitude of 1800 m, as reflected in activation of different upper body muscles, and oxygenation of the m. triceps brachii. Ten well-trained, male endurance athletes (25.3±4.1 yrs; 179.2±4.5 cm; 74.2±3.4 kg) performed four test trials, each involving three 3-min sessions on a double-poling ergometer with 3-min intervals of recovery. One trial was conducted entirely under normoxic (No) and another under hypoxic conditions \((Ho; F_iO_2 = 0.165)\). In the third and fourth trials, the exercise was performed in normoxia and hypoxia, respectively, with hyperoxic recovery \((HOX; F_iO_2 = 1.00)\) in both cases. Arterial hemoglobin saturation was higher under the two HOX conditions than without HOX (p<0.05). Integrated muscle electrical activity was not influenced by the oxygen content (best d = 0.51). Furthermore, the only difference in tissue saturation index measured via near-infrared spectroscopy observed was between the recovery periods during the NoNo and HoHOX interventions (P<0.05, d = 0.93). In the case of HoHo the athletes’ \(P_{mean}\) declined from the first to the third interval (P < 0.05), whereas Pmean was unaltered under the HoHOX, NoHOX and NoNo conditions. We conclude that the less pronounced decline in \(P_{mean}\) during 3 x 3-min double-poling sprints in normoxia and hypoxia with hyperoxic recovery is not related to changes in muscle activity or oxygenation. Moreover, we conclude that hyperoxia \((F_iO_2 = 1.00)\) used in conjunction with hypoxic or normoxic work intervals may serve as an effective aid when inhaled during the subsequent recovery intervals.