Refine
Has Fulltext
- yes (4)
Is part of the Bibliography
- yes (4)
Document Type
- Journal article (4)
Language
- English (4)
Keywords
- C virus (1)
- Tanzania (1)
- Uganda (1)
- adsorption (1)
- animal model (1)
- arteriovenous extracorporeal hemadsorption technique (1)
- blood (1)
- blood purification (1)
- cytokines (1)
- endotoxin (1)
Institute
- Medizinische Fakultät (2)
- Deutsches Zentrum für Herzinsuffizienz (DZHI) (1)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (1)
- Klinik und Poliklinik für Anästhesiologie (ab 2004) (1)
- Klinik und Poliklinik für Nuklearmedizin (1)
- Missionsärztliche Klinik (1)
Background: Sub-Saharan Africa has a high prevalence of hepatitis B virus (HBV) infections. Health care workers (HCWs) are at high risk of contracting HBV infection through their occupation. Vaccination of HCWs against HBV is standard practice in many countries, but is often not implemented in resource-poor settings. We aimed with this cross-sectional study to determine HBV prevalence, HCW vaccination status, and the risk factors for HCWs contracting HBV infection in Tanzania.
Methods: We enrolled 600 HCWs from a tertiary Tanzanian hospital. Their demographics, medical histories, HBV vaccination details and risk factors for contracting blood-borne infections were collected using a standardized questionnaire. Serum samples were tested for HBV and hepatitis C virus (HCV) markers by ELISA techniques, PCR and an anti-HBs rapid test. HCWs were divided in two subgroups: those at risk of contracting HBV (rHCW 79.2 %) via exposure to potentially infectious materials, and those considered not at risk of contracting HBV (nrHCW, 20.8 %). Results: The overall prevalence of chronic HBV infection (HBsAg+, anti-HBc+, anti-HBs-) was 7.0 % (42/598). Chronic HBV infection was found in 7.4 % of rHCW versus 5.6 % of nrHCW(p-value = 0.484). HCWs susceptible to HBV (HBsAg-, anti-HBc-, anti-HBs-) comprised 31.3 %. HBV immunity achieved either by healed HBV infection (HBsAg-, anti-HBc+, anti-HBs+) or by vaccination (HBsAg-, anti-HBc-, anti-HBs+) comprised 36.5 % and 20.2 %, respectively. 4.8 % of participants had indeterminate results (HBsAg-, anti-HBc+, anti-HBc-IgM-, anti-HBs-). Only 77.1 % of HCWs who received a full vaccination course had an anti-HBs titer > 10 ml/U. An anti-HBs point-of-care test was 80.7 % sensitive and 96.9 % specific. There was a significantly higher risk for contracting HBV (anti-HBc+) among those HCW at occupational risk (rHCW) of older age (odds ratios (OR) in rHCW 3.297, p < 0.0001 vs. nrHCW 1.385, p = 0.606) and among those HCW being employed more than 11 years (OR 2.51, p < 0.0001***). HCV prevalence was low (HCV antibodies 1.2 % and HCV-RNA 0.3 %).
Conclusions: Chronic HBV infection is common among Tanzanian HCWs. One third of HCWs were susceptible to HBV infection, highlighting the need for vaccination. Due to high prevalence of naturally acquired immunity against HBV pre-testing might be a useful tool to identify susceptible individuals.
In May 2014, six patients presented in Germany with a Sarcocystis-associated febrile myositis syndrome after returning from Tioman Island, Malaysia. During two earlier waves of infections, in 2011 and 2012, about 100 travellers returning to various European countries from the island were affected. While the first two waves were associated with travel to Tioman Island mostly during the summer months, this current series of infections is associated with travel in early spring, possibly indicating an upcoming new epidemic.
Purpose
The aim of this study was to compare the wave‐CAIPI (controlled aliasing in parallel imaging) trajectory to the Cartesian sampling for accelerated free‐breathing 4D lung MRI.
Methods
The wave‐CAIPI k‐space trajectory was implemented in a respiratory self‐gated 3D spoiled gradient echo pulse sequence. Trajectory correction applying the gradient system transfer function was used, and images were reconstructed using an iterative conjugate gradient SENSE (CG SENSE) algorithm. Five healthy volunteers and one patient with squamous cell carcinoma in the lung were examined on a clinical 3T scanner, using both sampling schemes. For quantitative comparison of wave‐CAIPI and standard Cartesian imaging, the normalized mutual information and the RMS error between retrospectively accelerated acquisitions and their respective references were calculated. The SNR ratios were investigated in a phantom study.
Results
The obtained normalized mutual information values indicate a lower information loss due to acceleration for the wave‐CAIPI approach. Average normalized mutual information values of the wave‐CAIPI acquisitions were 10% higher, compared with Cartesian sampling. Furthermore, the RMS error of the wave‐CAIPI technique was lower by 19% and the SNR was higher by 14%. Especially for short acquisition times (down to 1 minute), the undersampled Cartesian images showed an increased artifact level, compared with wave‐CAIPI.
Conclusion
The application of the wave‐CAIPI technique to 4D lung MRI reduces undersampling artifacts, in comparison to a Cartesian acquisition of the same scan time. The benefit of wave‐CAIPI sampling can therefore be traded for shorter examinations, or enhancing image quality of undersampled 4D lung acquisitions, keeping the scan time constant.
Background: Extracorporeal hemadsorption eliminates proinflammatory mediators in critically ill patients with hyperinflammation. The use of a pumpless extracorporeal hemadsorption technique allows its early usage prior to organ failure and the need for an additional medical device. In our animal model, we investigated the feasibility of pumpless extracorporeal hemadsorption over a wide range of mean arterial pressures (MAP). Methods: An arteriovenous shunt between the femoral artery and femoral vein was established in eight pigs. The hemadsorption devices were inserted into the shunt circulation; four pigs received CytoSorb\(^®\) and four Oxiris\(^®\) hemadsorbers. Extracorporeal blood flow was measured in a range between mean arterial pressures of 45–85 mmHg. Mean arterial pressures were preset using intravenous infusions of noradrenaline, urapidil, or increased sedatives. Results: Extracorporeal blood flows remained well above the minimum flows recommended by the manufacturers throughout all MAP steps for both devices. Linear regression resulted in CytoSorb\(^®\) blood flow [mL/min] = 4.226 × MAP [mmHg] − 3.496 (R-square 0.8133) and Oxiris\(^®\) blood flow [mL/min] = 3.267 × MAP [mmHg] + 57.63 (R-square 0.8708), respectively. Conclusion: Arteriovenous pumpless extracorporeal hemadsorption resulted in sufficient blood flows through both the CytoSorb\(^®\) and Oxiris\(^®\) devices over a wide range of mean arterial blood pressures and is likely an intriguing therapeutic option in the early phase of septic shock or hyperinflammatory syndromes.