Refine
Has Fulltext
- yes (37)
Is part of the Bibliography
- yes (37)
Year of publication
Document Type
- Journal article (37)
Keywords
- COVID-19 (8)
- acute respiratory distress syndrome (3)
- ECMO-Therapie (2)
- Germany (2)
- airway management (2)
- critical care (2)
- perioperative care (2)
- postoperative nausea and vomiting (2)
- pregnancy (2)
- 6-percent hydroxyethyl starch (1)
Institute
- Klinik und Poliklinik für Anästhesiologie (ab 2004) (37)
- Frauenklinik und Poliklinik (6)
- Institut für Klinische Epidemiologie und Biometrie (3)
- Kinderklinik und Poliklinik (3)
- Medizinische Klinik und Poliklinik I (3)
- Institut für Informatik (2)
- Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I) (2)
- Institut für Experimentelle Biomedizin (1)
- Institut für Hygiene und Mikrobiologie (1)
- Institut für Virologie und Immunbiologie (1)
EU-Project number / Contract (GA) number
- 101003595 (1)
Background
Coronavirus disease 2019 (COVID-19) associated coagulopathy (CAC) leads to thromboembolic events in a high number of critically ill COVID-19 patients. However, specific diagnostic or therapeutic algorithms for CAC have not been established. In the current study, we analyzed coagulation abnormalities with point-of-care testing (POCT) and their relation to hemostatic complications in patients suffering from COVID-19 induced Acute Respiratory Distress Syndrome (ARDS). Our hypothesis was that specific diagnostic patterns can be identified in patients with COVID-19 induced ARDS at risk of thromboembolic complications utilizing POCT.
Methods
This is a single-center, retrospective observational study. Longitudinal data from 247 rotational thromboelastometries (Rotem®) and 165 impedance aggregometries (Multiplate®) were analysed in 18 patients consecutively admitted to the ICU with a COVID-19 induced ARDS between March 12th to June 30th, 2020.
Results
Median age was 61 years (IQR: 51–69). Median PaO2/FiO2 on admission was 122 mmHg (IQR: 87–189), indicating moderate to severe ARDS. Any form of hemostatic complication occurred in 78 % of the patients with deep vein/arm thrombosis in 39 %, pulmonary embolism in 22 %, and major bleeding in 17 %. In Rotem® elevated A10 and maximum clot firmness (MCF) indicated higher clot strength. The delta between EXTEM A10 minus FIBTEM A10 (ΔA10) > 30 mm, depicting the sole platelet-part of clot firmness, was associated with a higher risk of thromboembolic events (OD: 3.7; 95 %CI 1.3–10.3; p = 0.02). Multiplate® aggregometry showed hypoactive platelet function. There was no correlation between single Rotem® and Multiplate® parameters at intensive care unit (ICU) admission and thromboembolic or bleeding complications.
Conclusions
Rotem® and Multiplate® results indicate hypercoagulability and hypoactive platelet dysfunction in COVID-19 induced ARDS but were all in all poorly related to hemostatic complications..
Background: Proportions of patients dying from the coronavirus disease-19 (COVID-19) vary between different countries. We report the characteristics; clinical course and outcome of patients requiring intensive care due to COVID-19 induced acute respiratory distress syndrome (ARDS).
Methods: This is a retrospective, observational multicentre study in five German secondary or tertiary care hospitals. All patients consecutively admitted to the intensive care unit (ICU) in any of the participating hospitals between March 12 and May 4, 2020 with a COVID-19 induced ARDS were included.
Results: A total of 106 ICU patients were treated for COVID-19 induced ARDS, whereas severe ARDS was present in the majority of cases. Survival of ICU treatment was 65.0%. Median duration of ICU treatment was 11 days; median duration of mechanical ventilation was 9 days. The majority of ICU treated patients (75.5%) did not receive any antiviral or anti-inflammatory therapies. Venovenous (vv) ECMO was utilized in 16.3%. ICU triage with population-level decision making was not necessary at any time. Univariate analysis associated older age, diabetes mellitus or a higher SOFA score on admission with non-survival during ICU stay.
Conclusions: A high level of care adhering to standard ARDS treatments lead to a good outcome in critically ill COVID-19 patients.
Summary
Blood oxygen saturation is an important clinical parameter, especially in postoperative hospitalized patients, monitored in clinical practice by arterial blood gas (ABG) and/or pulse oximetry that both are not suitable for a long-term continuous monitoring of patients during the entire hospital stay, or beyond. Technological advances developed recently for consumer-grade fitness trackers could—at least in theory—help to fill in this gap, but benchmarks on the applicability and accuracy of these technologies in hospitalized patients are currently lacking. We therefore conducted at the postanaesthesia care unit under controlled settings a prospective clinical trial with 201 patients, comparing in total >1,000 oxygen blood saturation measurements by fitness trackers of three brands with the ABG gold standard and with pulse oximetry. Our results suggest that, despite of an overall still tolerable measuring accuracy, comparatively high dropout rates severely limit the possibilities of employing fitness trackers, particularly during the immediate postoperative period of hospitalized patients.
Highlights
•The accuracy of O2 measurements by fitness trackers is tolerable (RMSE ≲4%)
•Correlation with arterial blood gas measurements is fair to moderate (PCC = [0.46; 0.64])
•Dropout rates of fitness trackers during O2 monitoring are high (∼1/3 values missing)
•Fitness trackers cannot be recommended for O2 measuring during critical monitoring
Background: Over the recent years, technological advances of wrist-worn fitness trackers heralded a new era in the continuous monitoring of vital signs. So far, these devices have primarily been used for sports.
Objective: However, for using these technologies in health care, further validations of the measurement accuracy in hospitalized patients are essential but lacking to date.
Methods: We conducted a prospective validation study with 201 patients after moderate to major surgery in a controlled setting to benchmark the accuracy of heart rate measurements in 4 consumer-grade fitness trackers (Apple Watch 7, Garmin Fenix 6 Pro, Withings ScanWatch, and Fitbit Sense) against the clinical gold standard (electrocardiography).
Results: All devices exhibited high correlation (r≥0.95; P<.001) and concordance (rc≥0.94) coefficients, with a relative error as low as mean absolute percentage error <5% based on 1630 valid measurements. We identified confounders significantly biasing the measurement accuracy, although not at clinically relevant levels (mean absolute error<5 beats per minute).
Conclusions: Consumer-grade fitness trackers appear promising in hospitalized patients for monitoring heart rate.
Background: The close monitoring of blood pressure during a caesarean section performed under central neuraxial anaesthesia should be the standard of safe anaesthesia. As classical oscillometric and invasive blood pressure measuring have intrinsic disadvantages, we investigated a novel, non-invasive technique for continuous blood pressure measuring. Methods: In this monocentric, retrospective data analysis, the reliability of continuous non-invasive blood pressure measuring using ClearSight\(^®\) (Edwards Lifesciences Corporation) is validated in 31 women undergoing central neuraxial anaesthesia for caesarean section. In addition, patients and professionals evaluated ClearSight\(^®\) through questioning. Results: 139 measurements from 11 patients were included in the final analysis. Employing Bland–Altman analyses, we identified a bias of −10.8 mmHg for systolic, of −0.45 mmHg for diastolic and of +0.68 mmHg for mean arterial blood pressure measurements. Pooling all paired measurements resulted in a Pearson correlation coefficient of 0.7 for systolic, of 0.67 for diastolic and of 0.75 for mean arterial blood pressure. Compensating the interindividual differences in linear regressions of the paired measurements provided improved correlation coefficients of 0.73 for systolic, of 0.9 for diastolic and of 0.89 for mean arterial blood pressure measurements. Discussion: Diastolic and mean arterial blood pressure are within an acceptable range of deviation from the reference method, according to the Association for the Advancement of Medical Instrumentation (AAMI) in the patient collective under study. Both patients and professionals prefer ClearSight\(^®\) to oscillometric blood pressure measurement in regard of comfort and handling.
Background
Systematic reviews attempt to gather all available evidence. Controversy exists regarding effort and benefit of including study results presented at conferences only. We recently published a Cochrane network meta-analysis (NMA) including 585 randomized controlled trials comparing drugs for prevention of postoperative nausea and vomiting (PONV). Studies published as conference abstracts only were excluded. This study aimed to include all eligible studies published as abstracts only, assessing their added value regarding reporting quality and effect on the review’s interpretation.
Methods
Conference abstracts were searched in the review’s excluded studies and conference proceedings of anaesthesiologic societies. We assessed their reporting quality regarding review’s eligibility criteria, Cochrane ‘risk of bias’ assessment tool 1.0, and adherence to CONSORT (Consolidated Standards of Reporting Trials) for abstracts. Abstracts were included in sensitivity NMA, and impact on the NMA structure was investigated.
Results
We identified 90 abstracts. A total of 14% (13/90) were eligible. A total of 86% (77/90) are awaiting classification due to insufficient reporting of review’s eligibility criteria. In abstracts awaiting classification, sufficient information was missing on standardization of anaesthesia in 71% (55/77), age of participants in 56% (43/77), and outcome details in 46% (36/77). A total of 73% (66/90) of abstracts lacked sufficient information on 15/25 data extraction items. Reported study characteristics of abstracts were comparable to included studies of the review. A total of 62% (56/90) of abstract trials were assessed as overall high risk of bias due to poor reporting. Median adherence to CONSORT for abstracts was 24% (IQR, 18 to 29%). Six of the 13 eligible abstracts reported relevant outcome data in sufficient detail for NMA on seven outcomes of the Cochrane review. Inclusion of abstracts did not substantially change the network structure, network effect estimates, ranking of treatments, or the conclusion. Certainty of evidence for headache on palonosetron use was upgraded from very low to low.
Conclusions
Most conference abstracts on PONV were insufficiently reported regarding review’s narrow inclusion criteria and could not be included in NMA. The resource-intensive search and evaluation of abstracts did not substantially extent the full-text evidence base of the review, given the few adequately reported abstracts. Conferences should oblige authors to adhere to CONSORT for abstracts.
Background: Remote ischemic conditioning is gaining interest as potential method to induce resistance against ischemia reperfusion injury in a variety of clinical settings. We performed a systematic review and meta-analysis to investigate whether remote ischemic conditioning reduces mortality, major adverse cardiovascular events, length of stay in hospital and in the intensive care unit and biomarker release in patients who suffer from or are at risk for ischemia reperfusion injury.
Methods and Results: Medline, EMBASE and Cochrane databases were searched for randomized clinical trials comparing remote ischemic conditioning, regardless of timing, with no conditioning. Two investigators independently selected suitable trials, assessed trial quality and extracted data. 23 studies in patients undergoing cardiac surgery (15 studies), percutaneous coronary intervention (four studies) and vascular surgery (four studies), comprising in total 1878 patients, were included in this review. Compared to no conditioning, remote ischemic conditioning did not reduce mortality (odds ratio 1.22 [95% confidence interval 0.48, 3.07]) or major adverse cardiovascular events (0.65 [0.38, 1.14]). However, the incidence of myocardial infarction was reduced with remote ischemic conditioning (0.50 [0.31, 0.82]), as was peak troponin release (standardized mean difference -0.28 [-0.47, -0.09]).
Conclusion: There is no evidence that remote ischemic conditioning reduces mortality associated with ischemic events; nor does it reduce major adverse cardiovascular events. However, remote ischemic conditioning did reduce the incidence of peri-procedural myocardial infarctions, as well as the release of troponin.