Refine
Has Fulltext
- yes (17)
Is part of the Bibliography
- yes (17)
Document Type
- Journal article (17)
Keywords
- surgery (4)
- Barbed suture (1)
- Barbed suture material (1)
- Blepharoplastik (1)
- Digitalisierung (1)
- Elderly patients (1)
- Flexor tendon repair (1)
- Gesundheits-App (1)
- Knotless tendon repair (1)
- Künstliche Intelligenz (1)
Institute
- Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II) (16)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (2)
- Lehrstuhl für Orthopädie (2)
- Klinik und Poliklinik für Mund-, Kiefer- und Plastische Gesichtschirurgie (1)
Background:
Propeller flaps require torsion of the vascular pedicle of up to 180 degrees. Contrary to free flaps, where the relevance of an intact vascular pedicle has been documented, little is known regarding twisted pedicles of propeller flaps. As secondary surgeries requiring undermining of the flap are common in the extremities, knowledge regarding the necessity to protect the pedicle is relevant. The aim of this study was a long-term evaluation of the patency of vascular pedicle of propeller flaps.
Methods:
In a retrospective clinical study, 22 patients who underwent soft-tissue reconstruction with a propeller flap were evaluated after 43 months. A Doppler probe was used to locate and evaluate the patency of the vascular pedicle of the flap.
Results:
The flaps were used in the lower extremity in 19 cases, on the trunk in 3 cases. All flaps had healed. In all patients, an intact vascular pedicle could be found. Flap size, source vessel, or infection could therefore not be linked to an increased risk of pedicle loss.
Conclusions:
The vascular pedicle of propeller flaps remains patent in the long term. This allows reelevation and undermining of the flap. We therefore recommend protecting the pedicle in all secondary cases to prevent later flap loss.
Multiple-level amputations of the upper extremity represent a surgical challenge generally only attempted in young patients. This case demonstrates a successful replantation in an elderly woman. The postoperative course was complicated by disseminated intravascular coagulopathy most likely due to inadequate resuscitation. Hand trauma is often underestimated in its general severity. Upper extremity amputations need to be handled similar to polytraumatized patients.
Hintergrund
Die Fotodokumentation von offenen Frakturen, Wunden, Dekubitalulzera, Tumoren oder Infektionen ist ein wichtiger Bestandteil der digitalen Patientenakte. Bisher ist unklar, welchen Stellenwert diese Fotodokumentation bei der Abrechnungsprüfung durch den Medizinischen Dienst der Krankenkassen (MDK) hat.
Fragestellung
Kann eine Smartphone-basierte Fotodokumentation die Verteidigung von erlösrelevanten Diagnosen und Prozeduren sowie der Verweildauer verbessern?
Material und Methoden
Ausstattung der Mitarbeiter mit digitalen Endgeräten (Smartphone/Tablet) in den Bereichen Notaufnahme, Schockraum, OP, Sprechstunden sowie auf den Stationen. Retrospektive Auswertung der Abrechnungsprüfung im Jahr 2019 und Identifikation aller Fallbesprechungen, in denen die Fotodokumentation eine Erlösveränderung bewirkt hat.
Ergebnisse
Von insgesamt 372 Fallbesprechungen half die Fotodokumentation in 27 Fällen (7,2 %) zur Bestätigung eines Operationen- und Prozedurenschlüssels (OPS) (n = 5; 1,3 %), einer Hauptdiagnose (n = 10; 2,7 %), einer Nebendiagnose (n = 3; 0,8 %) oder der Krankenhausverweildauer (n = 9; 2,4 %). Pro oben genanntem Fall mit Fotodokumentation ergab sich eine durchschnittliche Erlössteigerung von 2119 €. Inklusive Aufwandpauschale für die Verhandlungen wurde somit ein Gesamtbetrag von 65.328 € verteidigt.
Diskussion
Der Einsatz einer Smartphone-basierten Fotodokumentation kann die Qualität der Dokumentation verbessern und Erlöseinbußen bei der Abrechnungsprüfung verhindern. Die Implementierung digitaler Endgeräte mit entsprechender Software ist ein wichtiger Teil des digitalen Strukturwandels in Kliniken.
Objectives
Triangular fibrocartilage complex (TFCC) injuries frequently cause ulnar-sided wrist pain and can induce distal radioulnar joint instability. With its complex three-dimensional structure, diagnosis of TFCC lesions remains a challenging task even in MR arthrograms. The aim of this study was to assess the added diagnostic value of radial reformatting of isotropic 3D MRI datasets compared to standard planes after direct arthrography of the wrist.
Methods
Ninety-three patients underwent wrist MRI after fluoroscopy-guided multi-compartment arthrography. Two radiologists collectively analyzed two datasets of each MR arthrogram for TFCC injuries, with one set containing standard reconstructions of a 3D thin-slice sequence in axial, coronal and sagittal orientation, while the other set comprised an additional radial plane view with the rotating center positioned at the ulnar styloid. Surgical reports (whenever available) or radiological reports combined with clinical follow-up served as a standard of reference. In addition, diagnostic confidence and assessability of the central disc and ulnar-sided insertions were subjectively evaluated.
Results
Injuries of the articular disc, styloid and foveal ulnar attachment were present in 20 (23.7%), 10 (10.8%) and 9 (9.7%) patients. Additional radial planes increased diagnostic accuracy for lesions of the styloid (0.83 vs. 0.90; p = 0.016) and foveal (0.86 vs. 0.94; p = 0.039) insertion, whereas no improvement was identified for alterations of the central cartilage disc. Readers' confidence (p < 0.001) and assessability of the ulnar-sided insertions (p < 0.001) were superior with ancillary radial reformatting.
Conclusions
Access to the radial plane view of isotropic 3D sequences in MR arthrography improves diagnostic accuracy and confidence for ulnar-sided TFCC lesions.
Background: The soft tissue of the central pretibial area is difficult to reconstruct often requiring free tissue transfer. Especially medi- cally compromised patients are not ideal candidates for free tissue transfer and may benefit from expeditiously harvested local flaps with limited donor site morbidity. As muscle flaps are rare, pedi- cled flaps based on lateral perforators represent an alternative as the arc of rotation can often be limited to 90 °.
Material and Methods: A retrospective analysis of patient data was conducted to identify patients over the age of 60 years with comor- bidities that underwent pretibial soft tissue reconstruction with a single-pedicle perforator flap. Patient demographics, size and cause of the defect, flap dimension, arc of rotation and complications were recorded.
Results: Five patients with an average age of 71.4 years were in- cluded. The arc of rotation was 69 °, all flaps healed. There were two recurrences of osteomyelitis.
Conclusion: Lateral perforators originating from the anterior tib- ial artery or peroneal artery are adequate source vessels for single pedicled perforator flaps even in medically compromised patients. A perforator located proximal to the defect allows limiting the arcof rotation to less than 90 °, which increases the safety of the flap. Patients benefit from a simple procedure without a microvascular anastomosis and a donor site confined to one extremity
Background:
The integrity of the flexor tendon pulley apparatus is crucial for unimpaired function of the digits. Although secondary reconstruction is an established procedure in multi-pulley injuries, acute reconstruction of isolated, closed pulley ruptures is a rare occurrence. There are 3 factors influencing the functional outcome of a reconstruction: gapping distance between tendon and bone (E-space), bulkiness of the reconstruction, and stability. As direct repair is rarely done, grafts are used to reinforce the pulley. An advantage of the first extensor retinaculum graft is the synovial coating providing the possibility to be used both as a direct graft with synovial coating or as an onlay graft after removal of the synovia when the native synovial layer is present.
Methods:
A graft from the first dorsal extensor compartment is used as an onlay graft to reinforce the sutured A4 pulley. This technique allows reconstruction of the original dimensions of the pulley system while stability is ensured by anchoring the onlay graft to the bony insertions of the pulley.
Results:
Anatomical reconstruction can be achieved with this method. The measured E-space remained 0 mm throughout the recovery, while the graft incorporated as a slim reinforcement of the pulley, displaying no bulkiness.
Conclusions:
The ideal reconstruction should provide synovial coating and sufficient strength with minimal bulk. Early reconstruction using an onlay graft offers these options. The native synovial lining is preserved and the graft is used to reinforce the pulley.
Adjuvant Radiotherapy
(2011)