Refine
Has Fulltext
- yes (37)
Is part of the Bibliography
- yes (37)
Year of publication
Document Type
- Journal article (37)
Keywords
- COVID-19 (8)
- acute respiratory distress syndrome (3)
- ECMO-Therapie (2)
- Germany (2)
- airway management (2)
- critical care (2)
- perioperative care (2)
- postoperative nausea and vomiting (2)
- pregnancy (2)
- 6-percent hydroxyethyl starch (1)
Institute
- Klinik und Poliklinik für Anästhesiologie (ab 2004) (37)
- Frauenklinik und Poliklinik (6)
- Institut für Klinische Epidemiologie und Biometrie (3)
- Kinderklinik und Poliklinik (3)
- Medizinische Klinik und Poliklinik I (3)
- Institut für Informatik (2)
- Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I) (2)
- Institut für Experimentelle Biomedizin (1)
- Institut für Hygiene und Mikrobiologie (1)
- Institut für Virologie und Immunbiologie (1)
EU-Project number / Contract (GA) number
- 101003595 (1)
Background
Airway management is crucial and, probably, even the most important key competence in anaesthesiology, which directly influences patient safety and outcome. However, high-quality research is rarely published and studies usually have different primary or secondary endpoints which impedes clear unbiased comparisons between studies. The aim of the present study was to gather and analyse primary and secondary endpoints in video laryngoscopy studies being published over the last ten years and to create a core set of uniform or homogeneous outcomes (COS).
Methods
Retrospective analysis. Data were identified by using MEDLINE® database and the terms “video laryngoscopy” and “video laryngoscope” limited to the years 2007 to 2017. A total of 3351 studies were identified by the applied search strategy in PubMed. Papers were screened by two anaesthesiologists independently to identify study endpoints. The DELPHI method was used for consensus finding.
Results
In the 372 studies analysed and included, 49 different outcome categories/columns were reported. The items “time to intubation” (65.86%), “laryngeal view grade” (44.89%), “successful intubation rate” (36.56%), “number of intubation attempts” (23.39%), “complications” (21.24%), and “successful first-pass intubation rate” (19.09%) were reported most frequently. A total of 19 specific parameters is recommended.
Conclusions
In recent video laryngoscopy studies, many different and inhomogeneous parameters were used as outcome descriptors/endpoints. Based on these findings, we recommend that 19 specific parameters (e.g., “time to intubation” (inserting the laryngoscope to first ventilation), “laryngeal view grade” (C&L and POGO), “successful intubation rate”, etc.) should be used in coming research to facilitate future comparisons of video laryngoscopy studies.
Summary
Blood oxygen saturation is an important clinical parameter, especially in postoperative hospitalized patients, monitored in clinical practice by arterial blood gas (ABG) and/or pulse oximetry that both are not suitable for a long-term continuous monitoring of patients during the entire hospital stay, or beyond. Technological advances developed recently for consumer-grade fitness trackers could—at least in theory—help to fill in this gap, but benchmarks on the applicability and accuracy of these technologies in hospitalized patients are currently lacking. We therefore conducted at the postanaesthesia care unit under controlled settings a prospective clinical trial with 201 patients, comparing in total >1,000 oxygen blood saturation measurements by fitness trackers of three brands with the ABG gold standard and with pulse oximetry. Our results suggest that, despite of an overall still tolerable measuring accuracy, comparatively high dropout rates severely limit the possibilities of employing fitness trackers, particularly during the immediate postoperative period of hospitalized patients.
Highlights
•The accuracy of O2 measurements by fitness trackers is tolerable (RMSE ≲4%)
•Correlation with arterial blood gas measurements is fair to moderate (PCC = [0.46; 0.64])
•Dropout rates of fitness trackers during O2 monitoring are high (∼1/3 values missing)
•Fitness trackers cannot be recommended for O2 measuring during critical monitoring
Background
Iron deficiency (ID) is the leading cause of anemia worldwide. The prevalence of preoperative ID ranges from 23 to 33%. Preoperative anemia is associated with worse outcomes, making it important to diagnose and treat ID before elective surgery. Several studies indicated the effectiveness of intravenous iron supplementation in iron deficiency with or without anemia (ID(A)). However, it remains challenging to establish reliable evidence due to heterogeneity in utilized study outcomes. The development of a core outcome set (COS) can help to reduce this heterogeneity by proposing a minimal set of meaningful and standardized outcomes. The aim of our systematic review was to identify and assess outcomes reported in randomized controlled trials (RCTs) and observational studies investigating iron supplementation in iron-deficient patients with or without anemia.
Methods
We searched MEDLINE, CENTRAL, and ClinicalTrials.gov systematically from 2000 to April 1, 2022. RCTs and observational studies investigating iron supplementation in patients with a preoperative diagnosis of ID(A), were included. Study characteristics and reported outcomes were extracted. Outcomes were categorized according to an established outcome taxonomy. Quality of outcome reporting was assessed with a pre-specified tool. Reported clinically relevant differences for sample size calculation were extracted.
Results
Out of 2898 records, 346 underwent full-text screening and 13 studies (five RCTs, eight observational studies) with sufficient diagnostic inclusion criteria for iron deficiency with or without anemia (ID(A)) were eligible. It is noteworthy to mention that 49 studies were excluded due to no confirmed diagnosis of ID(A). Overall, 111 outcomes were structured into five core areas including nine domains. Most studies (92%) reported outcomes within the ‘blood and lymphatic system’ domain, followed by “adverse event” (77%) and “need for further resources” (77%). All of the latter reported on the need for blood transfusion. Reported outcomes were heterogeneous in measures and timing. Merely, two (33%) of six prospective studies were registered prospectively of which one (17%) showed no signs of selective outcome reporting.
Conclusion
This systematic review comprehensively depicts the heterogeneity of reported outcomes in studies investigating iron supplementation in ID(A) patients regarding exact definitions and timing. Our analysis provides a systematic base for consenting to a minimal COS.
Systematic review registration
PROSPERO CRD42020214247
Background
Data on the routine use of video-assisted laryngoscopy in peri-operative intubations are rather inconsistent and ambiguous, in part due to small populations and non-uniform outcome measures in past trials. Failed or prolonged intubation procedures are a reason for relevant morbidity and mortality. This study aims to determine whether video-assisted laryngoscopy (with both Macintosh-shaped and hyperangulated blades) is at least equal to the standard method of direct laryngoscopy with respect to the first-pass success rate. Furthermore, validated tools from the field of human factors will be applied to examine within-team communication and task load during this critical medical procedure.
Methods
In this randomized, controlled, three-armed parallel group design, multi-centre trial, a total of more than 2500 adult patients scheduled for perioperative endotracheal intubation will be randomized. In equally large arms, video-assisted laryngoscopy with a Macintosh-shaped or a hyperangulated blade will be compared to the standard of care (direct laryngoscopy with Macintosh blade). In a pre-defined hierarchical analysis, we will test the primary outcome for non-inferiority first. If this goal should be met, the design and projected statistical power also allow for subsequent testing for superiority of one of the interventions.
Various secondary outcomes will account for patient safety considerations as well as human factors interactions within the provider team and will allow for further exploratory data analysis and hypothesis generation.
Discussion
This randomized controlled trial will provide a solid base of data in a field where reliable evidence is of major clinical importance. With thousands of endotracheal intubations performed every day in operating rooms around the world, every bit of performance improvement translates into increased patient safety and comfort and may eventually prevent significant burden of disease. Therefore, we feel confident that a large trial has the potential to considerably benefit patients and anaesthetists alike.
Trial registration
ClincalTrials.gov NCT05228288.
Protocol version
1.1, November 15, 2021.
Background: Selective outcome reporting in clinical trials introduces bias in the body of evidence distorting clinical decision making. Trial registration aims to prevent this bias and is suggested by the International Committee of Medical Journal Editors (ICMJE) since 2004.
Methods: The 585 randomized controlled trials (RCTs) published between 1965 and 2017 that were included in a recently published Cochrane review on antiemetic drugs for prevention of postoperative nausea and vomiting were selected. In a retrospective study, we assessed trial registration and selective outcome reporting by comparing study publications with their registered protocols according to the ‘Cochrane Risk of bias’ assessment tool 1.0.
Results: In the Cochrane review, the first study which referred to a registered trial protocol was published in 2004. Of all 585 trials included in the Cochrane review, 334 RCTs were published in 2004 or later, of which only 22% (75/334) were registered. Among the registered trials, 36% (27/75) were pro- and 64% (48/75) were retrospectively registered. 41% (11/27) of the prospectively registered trials were free of selective outcome reporting bias, 22% (6/27) were incompletely registered and assessed as unclear risk, and 37% (10/27) were assessed as high risk. Major outcome discrepancies between registered and published high risk trials were a change from the registered primary to a published secondary outcome (32%), a new primary outcome (26%), and different outcome assessment times (26%). Among trials with high risk of selective outcome reporting 80% favoured at least one statistically significant result. Registered trials were assessed more often as ‘overall low risk of bias’ compared to non-registered trials (64% vs 28%).
Conclusions: In 2017, 13 years after the ICMJE declared prospective protocol registration a necessity for reliable clinical studies, the frequency and quality of trial registration in the field of PONV is very poor. Selective outcome reporting reduces trustworthiness in findings of clinical trials. Investigators and clinicians should be aware that only following a properly registered protocol and transparently reporting of predefined outcomes, regardless of the direction and significance of the result, will ultimately strengthen the body of evidence in the field of PONV research in the future.
No abstract available.
Background: The close monitoring of blood pressure during a caesarean section performed under central neuraxial anaesthesia should be the standard of safe anaesthesia. As classical oscillometric and invasive blood pressure measuring have intrinsic disadvantages, we investigated a novel, non-invasive technique for continuous blood pressure measuring. Methods: In this monocentric, retrospective data analysis, the reliability of continuous non-invasive blood pressure measuring using ClearSight\(^®\) (Edwards Lifesciences Corporation) is validated in 31 women undergoing central neuraxial anaesthesia for caesarean section. In addition, patients and professionals evaluated ClearSight\(^®\) through questioning. Results: 139 measurements from 11 patients were included in the final analysis. Employing Bland–Altman analyses, we identified a bias of −10.8 mmHg for systolic, of −0.45 mmHg for diastolic and of +0.68 mmHg for mean arterial blood pressure measurements. Pooling all paired measurements resulted in a Pearson correlation coefficient of 0.7 for systolic, of 0.67 for diastolic and of 0.75 for mean arterial blood pressure. Compensating the interindividual differences in linear regressions of the paired measurements provided improved correlation coefficients of 0.73 for systolic, of 0.9 for diastolic and of 0.89 for mean arterial blood pressure measurements. Discussion: Diastolic and mean arterial blood pressure are within an acceptable range of deviation from the reference method, according to the Association for the Advancement of Medical Instrumentation (AAMI) in the patient collective under study. Both patients and professionals prefer ClearSight\(^®\) to oscillometric blood pressure measurement in regard of comfort and handling.
Background
Coronavirus disease 2019 (COVID-19) associated coagulopathy (CAC) leads to thromboembolic events in a high number of critically ill COVID-19 patients. However, specific diagnostic or therapeutic algorithms for CAC have not been established. In the current study, we analyzed coagulation abnormalities with point-of-care testing (POCT) and their relation to hemostatic complications in patients suffering from COVID-19 induced Acute Respiratory Distress Syndrome (ARDS). Our hypothesis was that specific diagnostic patterns can be identified in patients with COVID-19 induced ARDS at risk of thromboembolic complications utilizing POCT.
Methods
This is a single-center, retrospective observational study. Longitudinal data from 247 rotational thromboelastometries (Rotem®) and 165 impedance aggregometries (Multiplate®) were analysed in 18 patients consecutively admitted to the ICU with a COVID-19 induced ARDS between March 12th to June 30th, 2020.
Results
Median age was 61 years (IQR: 51–69). Median PaO2/FiO2 on admission was 122 mmHg (IQR: 87–189), indicating moderate to severe ARDS. Any form of hemostatic complication occurred in 78 % of the patients with deep vein/arm thrombosis in 39 %, pulmonary embolism in 22 %, and major bleeding in 17 %. In Rotem® elevated A10 and maximum clot firmness (MCF) indicated higher clot strength. The delta between EXTEM A10 minus FIBTEM A10 (ΔA10) > 30 mm, depicting the sole platelet-part of clot firmness, was associated with a higher risk of thromboembolic events (OD: 3.7; 95 %CI 1.3–10.3; p = 0.02). Multiplate® aggregometry showed hypoactive platelet function. There was no correlation between single Rotem® and Multiplate® parameters at intensive care unit (ICU) admission and thromboembolic or bleeding complications.
Conclusions
Rotem® and Multiplate® results indicate hypercoagulability and hypoactive platelet dysfunction in COVID-19 induced ARDS but were all in all poorly related to hemostatic complications..