To decrease immunogenicity of the rat kidney, grafts were perfused with an anti-MHC class li monoclonal antibody (mAb ). How effectively this procedure blocked dass li-positive cells, which were mainly dendritic in appearance, was checked by immunostaining renal sections after perfusion and comparing them with in vitro stained sections. Optimum conditions were applied for graft pretreatment before transplantation. This procedure prolonged graft survival, though not satisfactorily from the biological point ofview (9.6 ± 0.8 versus 7.7 ± 0.5 days in the control group; P < 0.02). The dendritic cells were not killed but blocked. Several hours after transplantation, the mAb dissociated from these dass li-positive cells. It was also shown that donor cells migrate into the recipient's spieen early after transplantation. The number of these cells was smaller when the transplanted organ was perfused with the mAb. Further studies are suggested to deplete the graft of donor dendritic cells more adequately. They should also combine graft perfusion with antidass II mAb and recipient immunosuppression at reduced doses.
Background
The aortic pulse-wave velocity (PWV) is an important indicator of cardiovascular risk. In recent studies MRI methods have been developed to measure this parameter noninvasively in mice. Present techniques require additional hardware for cardiac and respiratory gating. In this work a robust self-gated measurement of the local PWV in mice without the need of triggering probes is proposed.
Methods
The local PWV of 6-months-old wild-type C57BL/6J mice (n=6) was measured in the abdominal aorta with a retrospectively triggered radial Phase Contrast (PC) MR sequence using the flow-area (QA) method. A navigator signal was extracted from the CMR data of highly asymmetric radial projections with short repetition time (TR=3 ms) and post-processed with high-pass and low-pass filters for retrospective cardiac and respiratory gating. The self-gating signal was used for a reconstruction of high-resolution Cine frames of the aortic motion. To assess the local PWV the volume flow Q and the cross-sectional area A of the aorta were determined. The results were compared with the values measured with a triggered Cartesian and an undersampled triggered radial PC-Cine sequence.
Results
In all examined animals a self-gating signal could be extracted and used for retrospective breath-gating and PC-Cine reconstruction. With the non-triggered measurement PWV values of 2.3±0.2 m/s were determined. These values are in agreement with those measured with the triggered Cartesian (2.4±0.2 m/s) and the triggered radial (2.3±0.2 m/s) measurement. Due to the strong robustness of the radial trajectory against undersampling an acceleration of more than two relative to the prospectively triggered Cartesian sampling could be achieved with the retrospective method.
Conclusion
With the radial flow-encoding sequence the extraction of a self-gating signal is feasible. The retrospective method enables a robust and fast measurement of the local PWV without the need of additional trigger hardware.
Seltene Erkrankungen (SE) werden durch die im deutschen Gesundheitssystem verwendete Diagnosenklassifikation ICD-10-GM (International Statistical Classification of Diseases and Related Health problems, 10th Revision, German Modification) nur zu einem kleinen Teil eindeutig erfasst. Daher sind Aussagen zur Häufigkeit von SE sowie zum speziellen Versorgungs- und Finanzierungsbedarf nicht möglich, was zu einer lückenhaften Datenlage als Entscheidungsgrundlage für Krankenkassen, Leistungserbringer und Gesundheitspolitik führt. Das Fehlen exakter Informationen behindert auch die wissenschaftliche Arbeit. Daher wird deutschlandweit ab 2023 die Verwendung der Alpha-ID-SE-Datei und der ORPHAcodes für die spezifische Erfassung von SE bei stationären Fällen verpflichtend.
Die Alpha-ID-SE-Datei verknüpft die ICD-10-GM-Kodes mit den international anerkannten ORPHAcodes für die Diagnose von SE. Kommerzielle Anbieter stellen zunehmend die benötigten IT-Tools zur Kodierung von SE zur Verfügung. An mehreren Universitätskliniken mit Zentren für SE wurden Lösungen etabliert, die eine vollständige Kodierung gewährleisten sollen. Hierzu gehören finanzielle Anreize für die kodierenden Bereiche, konkrete Nachfragen nach dem Vorliegen einer SE beim Kodiervorgang und eine semiautomatische Kodierung bei Patient*innen, die schon einmal mit einer SE an der Einrichtung betreut worden waren. Eine Kombination der verschiedenen Ansätze verspricht die höchste Wahrscheinlichkeit einer vollständigen Kodierung.
Für ein umfängliches Bild der SE im Gesundheitssystem und um dem speziellen Versorgungs- und Finanzierungsbedarf besser Rechnung tragen zu können, wäre auch im ambulanten Bereich eine möglichst spezifische und eindeutige Kodierung wünschenswert. Für komplexe SE und bisher undiagnostizierte Patient*innen wird zusätzlich eine strukturierte Erfassung des Phänotyps benötigt.