Two forms of a DNA polymerase have been purified from microplasmodia of Physarum polycephalum by poly(ethyleneimine) precipitation and chromatography on DEAE-Sephacel, phosphocellulose, heparin Sepharose, hydroxyapatite, DNA-agarose, blue-Sepharose. They were separated from DNA polymerase cx on phosphocellulose and from each other on heparin-Sepharose. Form HS1 enzymewas 30-40% pure and form HS2 enzyme 60% with regard toprotein contents of the preparations. Form HS2 enzymewas generated from form HS1 enzyme on prolonged standing of enzyme preparations. The DNA polymerases were obtained as complexes of a 60-kDa protein associated with either a 135-kDa (HS1) or a 110-kDa (HS2) DNA-polymerizing polypeptidein a 1:1 molar stoichiometry. The biochemical function of the 60-kDa protein remained unknown. The complexes tended to dissociate during gradient centrifugation and during partition chromatography as weil as during polyacrylamide gradient gel electrophoresis under nondenaturing conditions at high dilutions of samples. Both forms existed in plasmodia extracts, their proportions depending on several factors including those which promoted proteolysis. The DNA polymerases resembled eucaryotic DNA polymerase ß by several criteria and were functionally indistinguishable from each other. It is suggested that lower eucaryotes contain repair DNA polymerases, which are similar to those of eubacteria on a molecular mass basis.
Analytical ultracentrifugation (AUC) is a first principles based method to determine absolute sedimentation coefficients and buoyant molar masses of macromolecules and their complexes, reporting on their size and shape in free solution. The purpose of this multi-laboratory study was to establish the precision and accuracy of basic data dimensions in AUC and validate previously proposed calibration techniques. Three kits of AUC cell assemblies containing radial and temperature calibration tools and a bovine serum albumin (BSA) reference sample were shared among 67 laboratories, generating 129 comprehensive data sets. These allowed for an assessment of many parameters of instrument performance, including accuracy of the reported scan time after the start of centrifugation, the accuracy of the temperature calibration, and the accuracy of the radial magnification. The range of sedimentation coefficients obtained for BSA monomer in different instruments and using different optical systems was from 3.655 S to 4.949 S, with a mean and standard deviation of (4.304\(\pm\)0.188) S (4.4%). After the combined application of correction factors derived from the external calibration references for elapsed time, scan velocity, temperature, and radial magnification, the range of s-values was reduced 7-fold with a mean of 4.325 S and a 6-fold reduced standard deviation of \(\pm\)0.030 S (0.7%). In addition, the large data set provided an opportunity to determine the instrument-to-instrument variation of the absolute radial positions reported in the scan files, the precision of photometric or refractometric signal magnitudes, and the precision of the calculated apparent molar mass of BSA monomer and the fraction of BSA dimers. These results highlight the necessity and effectiveness of independent calibration of basic AUC data dimensions for reliable quantitative studies.