Institut für Pharmazie und Lebensmittelchemie
Refine
Has Fulltext
- yes (204)
Is part of the Bibliography
- yes (204)
Year of publication
Document Type
- Journal article (102)
- Doctoral Thesis (100)
- Conference Proceeding (1)
- Review (1)
Language
- English (204) (remove)
Keywords
- HPLC (9)
- Bioverfügbarkeit (7)
- Instrumentelle Analytik (6)
- Löslichkeit (6)
- Muscarinrezeptor (6)
- NMR-Spektroskopie (6)
- Aminosäuren (5)
- Arzneimittel (5)
- Impurity Profiling (5)
- Ligand <Biochemie> (5)
Institute
- Institut für Pharmazie und Lebensmittelchemie (204)
- Institut für Molekulare Infektionsbiologie (7)
- Institut für Pharmakologie und Toxikologie (7)
- Theodor-Boveri-Institut für Biowissenschaften (7)
- Graduate School of Life Sciences (6)
- Klinik und Poliklinik für Nuklearmedizin (6)
- Medizinische Klinik und Poliklinik II (6)
- Institut für Organische Chemie (5)
- Rudolf-Virchow-Zentrum (5)
- Medizinische Klinik und Poliklinik I (4)
Sonstige beteiligte Institutionen
- Universität Belgrad, Serbien (2)
- ACC GmbH Analytical Clinical Concepts (1)
- Apotheke, Universitätsklinikum Würzburg (1)
- Bundesinstitut für Arzneimittel und Medizinprodukte (1)
- Friedrich-Schiller-Universität Jena (1)
- Helmholtz Institute for RNA-based Infection Biology (HIRI), Josef-Schneider-Straße 2/D15, DE-9708 Wuerzburg, Germany (1)
- Helmholtz Institute for RNA-based Infection Biology (HIRI), Josef-Schneider-Straße 2/D15, DE-97080 Wuerzburg, Germany (1)
- IBMP - Institut für Biomedizinische und Pharmazeutische Forschung in Nürnberg-Heroldsberg (1)
- Johns Hopkins School of Medicine (1)
- Krankenhaushygiene und Antimicrobial Stewardship, Universitätsklinikum Würzburg (1)
EU-Project number / Contract (GA) number
- 26230120009 (1)
- 296679 (1)
- 314911 (1)
- 701983 (1)
A series of photoactivatable CO‐releasing molecules (PhotoCORMs) was prepared from manganese pentacarbonyl bromide and 1H‐benzimidazol‐2‐ylmethyl‐(N‐phenyl)amine ligands (L) bearing different electron‐donating and electron‐withdrawing groups R = H, 4‐CH\(_3\), 4‐OCH\(_3\), 4‐Cl, 4‐NO\(_2\), 2‐, 3‐, and 4‐COOCH\(_3\) on the phenyl substituent to give octahedral manganese(I) complexes of the general formula [MnBr(CO)\(_3\)(L)]. Aerated DMSO solutions of the compounds are stable in the dark for 16 h with no CO release. However, the compounds rapidly release CO upon illumination at 412–525 nm, depending on the substitution pattern. Its influence on the photophysical and photochemical properties was systematically explored using UV/Vis spectroscopy and CO release measurements with a commercial gas sensor system. In the nitro‐substituted compound, the electronically excited state switched from benzimidazole‐ to phenyl‐centered, leading to a markedly different photochemical behavior of this visible‐light activated PhotoCORM.
Various Mitsunobu conditions were investigated for a series of flavonolignans (silybin A, silybin B, isosilybin A, and silychristin A) to achieve either selective esterification in position C-23 or dehydration in a one-pot reaction yielding the biologically important enantiomers of hydnocarpin D, hydnocarpin and isohydnocarpin, respectively. This represents the only one-pot semi-synthetic method to access these flavonolignans in high yields.
Most drugs are no longer produced in their own countries by the pharmaceutical companies, but by contract manufacturers or at manufacturing sites in countries that can produce more cheaply. This not only makes it difficult to trace them back but also leaves room for criminal organizations to fake them unnoticed. For these reasons, it is becoming increasingly difficult to determine the exact origin of drugs. The goal of this work was to investigate how exactly this is possible by using different spectroscopic methods like nuclear magnetic resonance and near- and mid-infrared spectroscopy in combination with multivariate data analysis. As an example, 56 out of 64 different paracetamol preparations, collected from 19 countries around the world, were chosen to investigate whether it is possible to determine the pharmaceutical company, manufacturing site, or country of origin. By means of suitable pre-processing of the spectra and the different information contained in each method, principal component analysis was able to evaluate manufacturing relationships between individual companies and to differentiate between production sites or formulations. Linear discriminant analysis showed different results depending on the spectral method and purpose. For all spectroscopic methods, it was found that the classification of the preparations to their manufacturer achieves better results than the classification to their pharmaceutical company. The best results were obtained with nuclear magnetic resonance and near-infrared data, with 94.6%/99.6% and 98.7/100% of the spectra of the preparations correctly assigned to their pharmaceutical company or manufacturer.
SUMMARY
Insulin-like growth factor I (IGF-I) is a polypeptide with a molecular weight of 7.649 kDa and an anabolic potential. Thereby, IGF-I has a promising therapeutic value e.g. in muscle wasting diseases such as sarcopenia. IGF-I is mainly secreted by the liver in response to growth hormone (GH) stimulation and is rather ubiquitously found within all tissues. The effects of IGF-I are mediated by its respective IGF-I transmembrane tyrosine kinase receptor triggering the stimulation of protein synthesis, glucose uptake and the regulation of cell growth. The actions of IGF-I are modulated by six IGF binding proteins binding and transporting IGF-I in a binary or ternary complex to tissues and receptors and modulating the binding of IGF-I to its receptor. The nature of the formed complexes impacts IGF-I`s half-life, modulating the half-life between 10 minutes (free IGF-I) to 12 - 15 hours when presented in a ternary complex with IGF binding protein 3 and an acid labile subunit (ALS). Therefore, sustained drug delivery systems of free IGF-I are superficially seen as interesting for the development of controlled release profiles, as the rate of absorption is apparently and easily set slower by simple formulation as compared to the rapid rate of elimination. Thereby, one would conclude, the formulation scientist can rapidly develop systems for which the pharmacokinetics of IGF-I are dominated by the formulation release kinetics. However, the in vivo situation is more complex and as mentioned (vide supra), the half-life may easily be prolonged up to hours providing proper IGF-I complexation takes place upon systemic uptake. These and other aspects are reviewed in Chapter I, within which we introduce IGF-I as a promising therapeutic agent detailing its structure and involved receptors along with the resulting signaling pathways. We summarize the control of IGF-I pharmacokinetics in nature within the context of its complex system of 6 binding proteins to control half-life and tissue distribution. Furthermore, we describe IGF-I variants with modulated properties in vivo and originated from alternative splicing. These insights were translated into sophisticated IGF-I delivery systems for therapeutic use. Aside from safety aspects, the challenges and requirements of an effective IGF-I therapy are discussed. Localized and systemic IGF-I delivery strategies, different routes of administration as well as liquid and solid IGF-I formulations are reviewed. Effective targeting of IGF-I by protein decoration is outlined and consequently this chapter provides an interesting guidance for successful IGF-I-delivery. In Chapter II, we firstly outline the stability of IGF-I in liquid formulations with the intention to deliver the biologic through the lung and the impact of buffer type, sodium chloride concentration and pH value on IGF-I stability is presented. IGF-I integrity was preserved in histidine buffer over 4 months at room temperature, but methionine 59 oxidation (Met(o)) along with reducible dimer and trimer formation was observed in an acidic environment (pH 4.5) and using acetate buffer. Strong aggregation resulted in a complete loss of IGF-I bioactivity, whereas the potency was partly maintained in samples showing a slight aggregation and complete IGF-I oxidation. Atomization by air-jet or vibrating-mesh nebulizers yielded in limited Met(o) formation and no aggregation. The results of IGF-I nebulization experiments regarding aerosol output rate, mass median aerodynamic diameter and fine particle fraction were comparable with 0.9% sodium chloride reference, approving the applicability of liquid IGF-I formulations for pulmonary delivery. In Chapter III we escalated the development to solid delivery systems designed for alveolar landing upon inhalation and by deploying trehalose and the newly introduced for pulmonary application silk-fibroin as carriers. Microparticles were produced using nano spray drying following analyses including IGF-I integrity, IGF-I release profiles and aerodynamic properties. In vitro transport kinetics of IGF-I across pulmonary Calu-3 epithelia were suggesting similar permeability as compared to IGF-I’s cognate protein, insulin that has already been successfully administered pulmonary in clinical settings. These in vivo results were translated to an ex vivo human lung lobe model. This work showed the feasibility of pulmonary IGF-I delivery and the advantageous diversification of excipients for pulmonary formulations using silk-fibroin. Chapter IV focuses on an innovative strategy for safe and controllable IGF-I delivery. In that chapter we escalated the development to novel IGF-I analogues. The intention was to provide a versatile biologic into which galenical properties can be engineered through chemical synthesis, e.g. by site directed coupling of polymers to IGF-I. For this purpose we genetically engineered two IGF-I variants containing an unnatural amino acid at two positions, respectively, thereby integrating alkyne functions into the primary sequence of the protein. These allowed linking IGF-I with other molecules in a site specific manner, i.e. via a copper catalyzed azide-alkyne Huisgen cycloaddition (click reaction). In this chapter we mainly introduce the two IGF-I variants, detail the delivery concept and describe the optimization of the expression conditions of the IGF-I variants.
In conclusion, we span from simple liquid formulations for aerolization through solid systems for tailored for maximal alveolar landing to novel engineered IGF-I analogues. Thereby, three strategies for advanced IGF-I delivery were addressed and opportunities and limitations of each were outlined. Evidence was provided that sufficiently stable and easy to manufacture formulations can be developed as typically required for first in man studies. Interestingly, solid systems – typically introduced in later stages of pharmaceutical development – were quite promising. By use of silk-fibroin as a new IGF-I carrier for pulmonary administration, a new application was established for this excipient. The demonstrated success using the ex vivo human lung lobe model provided substantial confidence that pulmonary IGF-I delivery is possible in man. Finally, this work describes the expression of two IGF-I variants containing two unnatural amino acids to implement an innovative strategy for IGF-I delivery. This genetic engineering approach was providing the fundament for novel IGF-I analogues. Ideally, the biologic is structurally modified by covalently linked moieties for the control of pharmacokinetics or for targeted delivery, e.g. into sarcopenic muscles. One future scenario is dicussed in the ‘conclusion and outlook’ section for which IGF-I is tagged to a protease sensitive linker peptide and this linker peptide in return is coupled to a polyethylenglykole (PEG) polymer (required to prolong the half-life). Some proteases may serve as proxy for sarcopenia such that protease upregulation in compromised muscle tissues drives cleavage of IGF-I from the PEG. Thereby, IGF-I is released at the seat of the disease while systemic side effects are minimized.
Two chiral chemical molecules being mirror images of each other, also referred to as enantiomers, may have different pharmacokinetic, pharmacodynamic, and toxicological effects. Thus, pharmaceutical manufacturers and authorities are increasingly interested in the approval of enantiopure drugs. However, the isomeric purity and the limits for isomeric impurities have to be specified applying enantioselective analytical methods, such as capillary electrophoresis.
The separation of enantiomers in capillary electrophoresis may be improved by the addition of ionic liquids to the background electrolyte. The aim of this work was to investigate the influence of different separation conditions on the enantioseparation of phenethylamines in background electrolytes containing ionic liquids based on tetrabutylammonium cations.
Best chiral separations were achieved at acidic pH values using phosphate buffers containing 125 mmol/L tetrabutylammonium based salts. Different reasons explaining enhanced enantioseparations in buffers containing ionic liquids were found. First, due to an improvement of the cyclodextrin solubility, the addition of ionic liquids to the background electrolyte enables the use of higher concentrations of these chiral selector. Furthermore, the adsorption of tetrabutylammonium cations to the negatively charged capillary surface results in a reduction of the electroosmotic flow. Hence, the resulting prolongation of migration times leads to a longer period of time for the separation of temporarily formed diastereomeric analyte cyclodextrin complexes, which yields improved enantioseparation. Additionally, due to a decrease of the adsorption of positively charged phenethylamine analyte molecules to capillary surface silanol groups, the adsorption of ionic liquid cations inhibits peak broadening. A further reason explaining an enhanced enantioseparation by the addition of ionic liquids to the background electrolyte is a competition between tetrabutylammonium cations and analyte enantiomers for the inclusion into cyclodextrin cavities.
Furthermore, the influence of different chiral counterions, combined with tetrabutylammonium cations, on the enantioseparation of phenethylamines was investigated. Solely anions based on the basic proteinogenic amino acids L lysine and L arginine yielded chiral separation results superior to those achieved using achiral tetrabutylammonium chloride as background electrolyte additive. Especially the application of tetrabutylammonium L argininate gave very good enantioseparations of all investigated ephedrine derivatives, which might be explained by the ability of L arginine to affect the formation of complexes between analytes and cyclodextrins.
Besides the investigation of the influence of ionic liquids on the enantioseparation, complexes between phenethylamine enantiomers and β cyclodextrin derivatives were characterized by affinity capillary electrophoresis. The binding constants between analyte enantiomers and cyclodextrins and the electrophoretic mobilities of the temporarily formed complexes were determined and compared to the observed chiral resolution values. While neither the calculated binding constants nor their differences correlated with the quality of the enantioseparation, a strong correlation between the differences of the electrophoretic mobilities of the complexes and the chiral resolution values was found.
The Corona® charged aerosol detector (CAD) is an aerosol-based detector first de-scribed by Dixon and Peterson in 2002. It is capable of detecting compounds inde-pendent from their physico-chemical properties presumed the analyte is sufficiently non-volatile. Consequently, the CAD is often applied to the analysis of substances that do not possess a suitable UV chromophore. Major drawbacks are however, the detector signal is non-linear and depending on the content of organic solvent in the mobile phase.
This thesis tried to explore possible applications of the CAD for pharmaceutical analysis. Therefore, several substances from different compound classes were in-vestigated. Newly developed or existing methods were validated. Thus the perfor-mance of the CAD could be examined. Both assay and impurity determination were evaluated for their compliance with ICH Q2(R1) “Validation of Analytical Proce-dures” and the “Technical Guide for the Elaboration of Monographs”.
In the course of the establishment of reference substances at the EDQM, a generic screening method for the identification of organic and inorganic pharmaceutical counterions was needed. An HPLC-CAD method developed by Zhang et al. was therefore investigated for its suitability for pharmacopoeial purpose. Method valida-tion was performed. It was found that 23 ions could be separated and detected. Iden-tification was achieved via retention time of an authentic standard of the corre-sponding ions. Alternatively, peak assignment was performed by determination of the exact mass using TOF-MS. Ions could be quantified as impurities or for stoichi-ometric purpose.
For the impurity control in topiramate, the performance characterstics of the CAD were compared to that of an ELSD. CAD was superior to ELSD in terms of repeata-bility, sensitivity and linearity. However, impurities could be quantified with satisfac-tory accuracy with both detectors. The application of the ELSD was not feasible due to non-reproducible spike peaks eluting after the principle peak in the chromatogram of the test solution. One of the impurities, topiramate impurity A (diacetonide), gave no or a vastly diminished signal in the ELSD and the CAD, respectively. It is evapo-rated during the detection process due to its relatively high vapor pressure. The re-sponse could be enhanced by a factor of nine via post-column addition of acetoni-trile and a lower nebulizer temperature. As the response of topiramate impurity A was still about thousand-fold lower than the response of all other impurities, its quantification was not feasible. Additionally, the HPLC-CAD was successfully vali-dated as an assay procedure for topiramate.
There seems to be a great potential in the application of the CAD to the analysis of excipients as most compounds do not possess a suitable UV chromophore. Here, a simple and rapid HPLC-CAD method for the determination of polidocanol (PD) was developed. The method was successfully validated as a potential assay procedure for the Ph. Eur. as none is described in either of the two PD monographs. The same method was applied to the determination of the PD release from a pharmaceutical polymer matrix.
A method for the determination of the fatty acid (FA) composition of polysorbate 80 (PS80) was developed and validated. Using the CAD and mass spectrometry, we were able to identify two new FAs in 16 batches from four manufacturers. All batch-es complied with pharmacopoeial specification. Furthermore, the overall composi-tion of the different PS80 species (“fingerprinting”) and the peroxide content were determined. In addition to the chemical characterization, functionality related charac-teristics (FRCs) were determined. Correlations between chemical composition and FRCs were found.
The validation data of the above mentioned methods suggests that the CAD repre-sents a viable detection technique for pharmaceutical analysis. The CAD was suffi-ciently sensitive for non-volatile analytes. Impurity control down to concentrations of 0.05 or 0.03%, as demanded by ICH Q3A (R2), is achievable. However, the response of semi-volatile compounds may be drastically diminished. It could be confirmed that the response of the CAD is linear when the range does not exceed two orders of magnitude. Exceptions may be observed depending on the actual method setup. When the measuring range is sufficiently narrow, quantification can be done using single-point calibration which is common practice in pharmaceutical anlysis. Impuri-ties may also be quantified against a single calibration solution. However, correction factors may be needed and the accuracy is considerably lower compared to an as-say method. If a compound is to be quantified over a large concentration range, log-log transformation of the calibration curve is needed and a decreased accuracy has to be accepted.
The work presented in this thesis was mainly targeted at exploring the capabilities of evaporation based LC detectors as well as further alternatives for the control of impurities in substances not exhibiting a suitable chromophore for UV-detection. In the course of the work carried out, several new methods for the identification, impurities control and composition testing of APIs were elaborated. An evaporation based detector that entered into the field of pharmaceutical analysis in the recent years was the Evaporative Light Scattering Detector (ELSD). However, non-reproducible spikes were reported when injecting concentrated test solutions as they are usually required for the control of impurities. The reasons, for the appearance of these spikes as well as possibilities for their avoidance were explored in a systematic study. Moreover, the dependence of the detector sensitivity on different eluent composition, eluent flow-rate and ELSD settings was investigated. In the course of the revision of the Ph.Eur. monographs for aspartic acid and alanine, a C18 reversed phase ion-pair LC method using 1 mmol/L of perfluoroheptanoic acid as an ion-pair reagent and a charged aerosol detector (CAD) was developed and fully validated for the purity control of Asp. The method was capable of separating the organic acids and major amino acids known to occur as process related impurities. With a slight modification, the method was also applicable for the purity control of Ala. Based on the developed LC-CAD method for the impurity control of alanine, a comparative study of the performance characteristics of different evaporation based LC detectors, i.e. ELSD, CAD and the recently developed Nano Quantity Analyte Detector (NQAD) was carried out. Additionally, an MS detector and qNMR were included in this study. It was found that the control of impurities in Alanine at an ICH conform level could be ensured using LC coupled to CAD, MSD and NQAD detection as well as by the use of qNMR. In terms of performance, prize and ease of use CAD and NQAD were found to be the most suitable alternatives. In terms of repeatability and sensitivity, the CAD appeared slightly superior to the NQAD. The quality of streptomycin sulfate is not sufficiently controlled by the current Ph.Eur. monograph in that an appropriate test for the control of the related substances is missing. A study was carried out to develop a C18 reversed phase ion-pair LC method using pentafluoropropionic acid as an ion-pair reagent and a CAD for the identification and control of the related substances. The developed method allowed the separation of 21 impurities from streptomycin. Moreover, coupling of the method to MS allowed the identification of the separated impurities. The method was shown to be sufficiently sensitive to control the related substances with a disregard limit of 0.1% as it is normally applied in the Ph.Eur. for products derived from fermentation. Currently, the aescin content of horse-chestnut standardized dry extract is determined using a complex and laborious photometric determination. A more selective LC-UV assay determination for beta-aescin has been proposed for the Ph.Eur. draft monograph of horse-chestnut standardized dry extract. Possibilities were explored to further improve the LC-method using detection by CAD. It was demonstrated that by the use of a modified LC-CAD method several problems related to the differences in the UV-response of the various components contained in the active aescin fraction could be eliminated. Moreover the proposed reference standard strategy was reviewed. Eventually, it was demonstrated on the example of two different clusters of pharmacologically active peptides how low energy collision induced dissociation mass spectrometry (low energy CID-MS) can successfully be used for identification testing in pharmacopoeial monographs. In this respect, the combination of a direct confirmation of the molecular mass via the m/z-ratio of the molecule ions with structural sequence information obtained by low energy CID-MS experiments was found to deliver a higher degree of certainty of the identity of a given substance than the set of tests currently described in the monographs. A significant gain in efficiency and throughput and important reduction of the amount of sample consumed during testing were identified as being additional advantages of this approach. Taken together, it could be demonstrated on various examples how recent technological advancements in the field of analytical chemistry can contribute to improve the quality control of APIs.
Upon approval of a drug, the stability of the API and the FPP has to be studied intensively because it determines the shelf-life. If a drug is found to be stable, the expiry date is arbitrary set to five years at the maximum, if a drug tends to undergo degradation, the expiry date is set shorter. The drug product must comply with predefined specifications in accordance with the ICH guidelines Q6A and Q6B during its entire market life. The content of the active substance is required to be within a specification of 95–105% of its labeled claim until expiry corresponding to the ICH guideline Q1A(R2). However, there is little or scattered literature information addressing the stability of drug products beyond their expiry dates. The objective of this thesis was to study and assess the long-term stability of a collection involving numerous pure drug substances and ampoules manufactured in the 20th century. The content and the impurity profile were examined by means of appropriate analytical methods, mainly using liquid chromatography. The results were compared to data being available in the literature. Assessing the stability regarding the dosage form and the affiliation of the drug class was conducted.
The experimental studies comprise the examination of 50 drug substances manufactured 20–30 years ago and 14 long expired ampoules which were older than 40 years in the time of analysis, exceeding many times the maximum shelf life of five years.
For investigation of the solid drug substances, pharmacopoeial methods were applied as far as possible. Indeed, results of the study showed that 44 tested substances still complied with the specification of the Ph. Eur. with regard to the content and impurity profile, even after more than two decades of storage.
For analysis of the injection solutions, HPLC-UV and HPLC-ESI/MS techniques were applied, commonly based on liquid chromatography methods of the Ph. Eur. for determination of related substances. Each method was further validated for its application to ensure accurate API quantification corresponding to ICH Q2(R1). Quite a few ampoules were identified to show surprisingly high stability. In spite of their age of 53–72 years, APIs such as caffeine, etilefrine, synephrine, metamizole sodium, furosemide, and sodium salicylate complied with the specified content that is valid nowadays, respectively. Nevertheless, typical degradation reaction, e.g. hydrolysis, oxidation, or isomerization, was observed in all remaining ampoules. Various degrees of hydrolysis were revealed for scopolamine, procaine, and adenosine triphosphate, the contents were decreased to 71%, 70%, and 15% of the declared concentrations, respectively. In the epinephrine and dipyridamole ampoules, oxidative degradation has been occurred, finding respective API contents of more or less 70%. For dihydroergotamine, excessive decomposition by epimerization was observed, resulting in an API content of 21% and degradation by isomerization was found in lobeline, still containing 64% of the labeled claim.
In conclusion, supported by the data of the present studies and the literature, defining and authorizing a longer shelf-life may be applicable to numerous pharmaceuticals which should be considered by pharmaceutical manufacturers and regulatory authorities, if justified based on stability studies. A general extension of the shelf-lives of drug products and the abolishment or extension of the maximum shelf-life limit of five years would prevent disposing of still potent medications and save a lot of money to the entire health care system.