Background
Traumatic separation of the pubic symphysis can destabilize the pelvis and require surgical fixation to reduce symphyseal gapping. The traditional approach involves open reduction and the implantation of a steel symphyseal plate (SP) on the pubic bone to hold the reposition. Despite its widespread use, SP-fixation is often associated with implant failure caused by screw loosening or breakage.
Methods
To address the need for a more reliable surgical intervention, we developed and tested two titanium cable-clamp implants. The cable served as tensioning device while the clamp secured the cable to the bone. The first implant design included a steel cable anterior to the pubic symphysis to simplify its placement outside the pelvis, and the second design included a cable encircling the pubic symphysis to stabilize the anterior pelvic ring. Using highly reproducible synthetic bone models and a limited number of cadaver specimens, we performed a comprehensive biomechanical study of implant stability and evaluated surgical feasibility.
Results
We were able to demonstrate that the cable-clamp implants provide stability equivalent to that of a traditional SP-fixation but without the same risks of implant failure. We also provide detailed ex vivo evaluations of the safety and feasibility of a trans-obturator surgical approach required for those kind of fixation.
Conclusion
We propose that the developed cable-clamp fixation devices may be of clinical value in treating pubic symphysis separation.
Hintergrund
Die Fotodokumentation von offenen Frakturen, Wunden, Dekubitalulzera, Tumoren oder Infektionen ist ein wichtiger Bestandteil der digitalen Patientenakte. Bisher ist unklar, welchen Stellenwert diese Fotodokumentation bei der Abrechnungsprüfung durch den Medizinischen Dienst der Krankenkassen (MDK) hat.
Fragestellung
Kann eine Smartphone-basierte Fotodokumentation die Verteidigung von erlösrelevanten Diagnosen und Prozeduren sowie der Verweildauer verbessern?
Material und Methoden
Ausstattung der Mitarbeiter mit digitalen Endgeräten (Smartphone/Tablet) in den Bereichen Notaufnahme, Schockraum, OP, Sprechstunden sowie auf den Stationen. Retrospektive Auswertung der Abrechnungsprüfung im Jahr 2019 und Identifikation aller Fallbesprechungen, in denen die Fotodokumentation eine Erlösveränderung bewirkt hat.
Ergebnisse
Von insgesamt 372 Fallbesprechungen half die Fotodokumentation in 27 Fällen (7,2 %) zur Bestätigung eines Operationen- und Prozedurenschlüssels (OPS) (n = 5; 1,3 %), einer Hauptdiagnose (n = 10; 2,7 %), einer Nebendiagnose (n = 3; 0,8 %) oder der Krankenhausverweildauer (n = 9; 2,4 %). Pro oben genanntem Fall mit Fotodokumentation ergab sich eine durchschnittliche Erlössteigerung von 2119 €. Inklusive Aufwandpauschale für die Verhandlungen wurde somit ein Gesamtbetrag von 65.328 € verteidigt.
Diskussion
Der Einsatz einer Smartphone-basierten Fotodokumentation kann die Qualität der Dokumentation verbessern und Erlöseinbußen bei der Abrechnungsprüfung verhindern. Die Implementierung digitaler Endgeräte mit entsprechender Software ist ein wichtiger Teil des digitalen Strukturwandels in Kliniken.
Background:
Fatty Degeneration (FD) of the rotator cuff muscles influences functional and anatomical outcome after rotator cuff repair. The MRI based estimation of fatty degeneration is the gold standard. There is some evidence that Ultrasound elastography (EUS) can detect local differences of tissue stiffness in muscles and tendons. Shear-wave elastography (SWE) was evaluated to determine the extent to which shear wave velocity was associated with measures of fatty degeneration. MRI-spectroscopic fat measurement was used as a reference to quantify the amount of fat in the muscle belly.
Methods:
Forty-two patients underwent SWE of the supraspinatus muscles at its thickest diameter. After ultrasound evaluation an MRI-spectroscopic fat measurement of the supraspinatus muscle was performed using the SPLASH-technique. A gel filled capsule was used to locate the measured area in the MRI. The values of shear wave velocity (SWV) measured with SWE and spectroscopic fat measurement were correlated statistically using Pearson’s correlation test.
Results:
Correlation of the fat amount measured with MRI-spectroscopy and the SWV measured with SWE was ρ =0.82. Spectroscopic measured fat ratio of the supraspinatus muscle ranged from 0% to 77.41% and SWV from 1.59 m/s to 5.32 m/s. In 4 patients no sufficient SWE could be performed, these individuals showed a larger diameter of the overlying soft tissue. SWV measured with SWE showed a good correlation with MRI spectroscopic fat amount of the supraspinatus muscle.
Conclusion:
These preliminary data suggest that SWE may be a sufficient tool in detecting and estimating the amount of fatty degeneration in the supraspinatus muscle in real time. Large overlying soft tissue may be a limitation in performing sufficient EUS.
Background
The Goutallier Classification is a semi quantitative classification system to determine the amount of fatty degeneration in rotator cuff muscles. Although initially proposed for axial computer tomography scans it is currently applied to magnet-resonance-imaging-scans. The role for its clinical use is controversial, as the reliability of the classification has been shown to be inconsistent. The purpose of this study was to compare the semi quantitative MRI-based Goutallier Classification applied by 5 different raters to experimental MR spectroscopic quantitative fat measurement in order to determine the correlation between this classification system and the true extent of fatty degeneration shown by spectroscopy.
Methods
MRI-scans of 42 patients with rotator cuff tears were examined by 5 shoulder surgeons and were graduated according to the MRI-based Goutallier Classification proposed by Fuchs et al. Additionally the fat/water ratio was measured with MR spectroscopy using the experimental SPLASH technique. The semi quantitative grading according to the Goutallier Classification was statistically correlated with the quantitative measured fat/water ratio using Spearman’s rank correlation.
Results
Statistical analysis of the data revealed only fair correlation of the Goutallier Classification system and the quantitative fat/water ratio with R = 0.35 (p < 0.05). By dichotomizing the scale the correlation was 0.72. The interobserver and intraobserver reliabilities were substantial with R = 0.62 and R = 0.74 (p < 0.01).
Conclusion
The correlation between the semi quantitative MRI based Goutallier Classification system and MR spectroscopic fat measurement is weak. As an adequate estimation of fatty degeneration based on standard MRI may not be possible, quantitative methods need to be considered in order to increase diagnostic safety and thus provide patients with ideal care in regard to the amount of fatty degeneration. Spectroscopic MR measurement may increase the accuracy of the Goutallier classification and thus improve the prediction of clinical results after rotator cuff repair. However, these techniques are currently only available in an experimental setting.