Refine
Has Fulltext
- yes (30)
Is part of the Bibliography
- yes (30)
Year of publication
Document Type
- Journal article (30)
Keywords
- fracture (4)
- surgery (4)
- Coronavirus (2)
- Injury Severity Score (2)
- Intensivkapazitäten (2)
- Pandemie (2)
- Polytrauma (2)
- arthritis (2)
- classification (2)
- fixation (2)
Institute
- Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II) (30)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (3)
- Klinik und Poliklinik für Anästhesiologie (ab 2004) (3)
- Institut für Anatomie und Zellbiologie (2)
- Lehrstuhl für Orthopädie (2)
- Abteilung für Funktionswerkstoffe der Medizin und der Zahnheilkunde (1)
- Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I) (1)
- Neurochirurgische Klinik und Poliklinik (1)
- Physiologisches Institut (1)
- Urologische Klinik und Poliklinik (1)
EU-Project number / Contract (GA) number
- 309962 (1)
Background
To cover soft tissue defects, the perforator-based propeller flap offers the option to rotate healthy tissue into complex wounds. By rotating the flap, the perforator is torqued. As a result, perfusion changes are possible.
Methods
A retrospective data analysis of patients was done, who received a propeller flap to cover soft tissue defects of the lower extremity as well as a peri- and postoperative perfusion monitoring with a laser-Doppler-spectrophotometry system. Additionally, patient-specific data were collected.
Results
Seven patients were identified. Four patients experienced early complications, two epidermolysis of the distal flap areas, three wound healing disorders, and one partial flap necrosis. Intraoperative perfusion monitoring showed a decline of blood flow after incision of the flap, especially at distal flap site. In case of complications, there were prolonged blood flow declines up to the first postoperative day.
Conclusion
Torqueing the perforator by rotating the flap can cause an impairment in inflow and outflow. If the impairment is prolonged, perfusion-associated complications are possible. The identification of a viable perforator is particularly important. In addition, a conservative postoperative mobilization is necessary to compensate for the impaired and adapting outflow.
Traumatic brain injury (TBI) is the leading cause of death and disability in polytrauma and is often accompanied by concomitant injuries. We conducted a retrospective matched-pair analysis of data from a 10-year period from the multicenter database TraumaRegister DGU\(^®\) to analyze the impact of a concomitant femoral fracture on the outcome of TBI patients. A total of 4508 patients with moderate to critical TBI were included and matched by severity of TBI, American Society of Anesthesiologists (ASA) risk classification, initial Glasgow Coma Scale (GCS), age, and sex. Patients who suffered combined TBI and femoral fracture showed increased mortality and worse outcome at the time of discharge, a higher chance of multi-organ failure, and a rate of neurosurgical intervention. Especially those with moderate TBI showed enhanced in-hospital mortality when presenting with a concomitant femoral fracture (p = 0.037). The choice of fracture treatment (damage control orthopedics vs. early total care) did not impact mortality. In summary, patients with combined TBI and femoral fracture have higher mortality, more in-hospital complications, an increased need for neurosurgical intervention, and inferior outcome compared to patients with TBI solely. More investigations are needed to decipher the pathophysiological consequences of a long-bone fracture on the outcome after TBI.
The calcaneal beak fracture is a rare avulsion fracture of the tuber calcanei characterized by a solid bony fragment at the Achilles tendon insertion. Treatment usually requires osteosynthesis. However, lack of biomechanical understanding of the ideal fixation technique persists. A beak fracture was simulated in synthetic bones and assigned to five different groups of fixation: A) 6.5-mm partial threaded cannulated screws, B) 4.0-mm partial threaded cannulated screws, C) 5.0-mm headless cannulated compression screws, D) 2.3-mm locking plate, and E) 2.8-mm locking plate. Different traction force levels were applied through an Achilles tendon surrogate in a material-testing machine on all stabilized synthetic bones. Outcome measures were peak-to-peak displacement, total displacement, plastic deformation, stiffness, visual-fracture-line displacement, and mode of implant failure. The 2.3- and 2.8-mm plating groups showed a high drop-out rate at 100 N tension force and failed under higher tension levels of 200 N. The fracture fixation using 4.0-mm partial threaded screws showed a significantly higher repair strength and was able to withhold cyclic loading up to 300 N. The lowest peak-to-peak displacement and the highest load-to-failure and stiffness were provided by fracture fixation using 6.5-mm partial threaded cannulated screws or 5.0-mm headless cannulated compression screws. As anticipated, large 6.5-mm screw diameters provide the best biomechanical fixation. Surprisingly, the 5.0-mm headless cannulated compression screws yield reliable stability despite the absent screw head and washer. When such large screws cannot be applied, 4.0-mm screws also allow reasonable fixation strength. Plate fixation should be implemented with precaution and in combination with a restrictive postoperative motion protocol. Finally, clinical cases about the surgical application and recovery are included.
Background
Traumatic separation of the pubic symphysis can destabilize the pelvis and require surgical fixation to reduce symphyseal gapping. The traditional approach involves open reduction and the implantation of a steel symphyseal plate (SP) on the pubic bone to hold the reposition. Despite its widespread use, SP-fixation is often associated with implant failure caused by screw loosening or breakage.
Methods
To address the need for a more reliable surgical intervention, we developed and tested two titanium cable-clamp implants. The cable served as tensioning device while the clamp secured the cable to the bone. The first implant design included a steel cable anterior to the pubic symphysis to simplify its placement outside the pelvis, and the second design included a cable encircling the pubic symphysis to stabilize the anterior pelvic ring. Using highly reproducible synthetic bone models and a limited number of cadaver specimens, we performed a comprehensive biomechanical study of implant stability and evaluated surgical feasibility.
Results
We were able to demonstrate that the cable-clamp implants provide stability equivalent to that of a traditional SP-fixation but without the same risks of implant failure. We also provide detailed ex vivo evaluations of the safety and feasibility of a trans-obturator surgical approach required for those kind of fixation.
Conclusion
We propose that the developed cable-clamp fixation devices may be of clinical value in treating pubic symphysis separation.
Background
Morphology and glenoid involvement determine the necessity of surgical management in scapula fractures. While being present in only a small share of patients with shoulder trauma, numerous classification systems have been in use over the years for categorization of scapula fractures. The purpose of this study was to evaluate the established AO/OTA classification in comparison to the classification system of Euler and Rüedi (ER) with regard to interobserver reliability and confidence in clinical practice.
Methods
Based on CT imaging, 149 patients with scapula fractures were retrospectively categorized by two trauma surgeons and two radiologists using the classification systems of ER and AO/OTA. To measure the interrater reliability, Fleiss kappa (κ) was calculated independently for both fracture classifications. Rater confidence was stated subjectively on a five-point scale and compared with Wilcoxon signed rank tests. Additionally, we computed the intraclass correlation coefficient (ICC) based on absolute agreement in a two-way random effects model to assess the diagnostic confidence agreement between observers.
Results
In scapula fractures involving the glenoid fossa, interrater reliability was substantial (κ = 0.722; 95% confidence interval [CI] 0.676–0.769) for the AO/OTA classification in contrast to moderate agreement (κ = 0.579; 95% CI 0.525–0.634) for the ER classification system. Diagnostic confidence for intra-articular fracture patterns was superior using the AO/OTA classification compared to ER (p < 0.001) with higher confidence agreement (ICC: 0.882 versus 0.831). For extra-articular fractures, ER (κ = 0.817; 95% CI 0.771–0.863) provided better interrater reliability compared to AO/OTA (κ = 0.734; 95% CI 0.692–0.776) with higher diagnostic confidence (p < 0.001) and superior agreement between confidence ratings (ICC: 0.881 versus 0.912).
Conclusions
The AO/OTA classification is most suitable to categorize intra-articular scapula fractures with glenoid involvement, whereas the classification system of Euler and Rüedi appears to be superior in extra-articular injury patterns with fractures involving only the scapula body, spine, acromion and coracoid process.
Older patients sustaining tibial head depression fractures often cannot follow the post-operative rehabilitation protocols with partial weight-bearing of the affected limb, leading to osteosynthesis failure, cartilage step-off and arthritis development. Therefore, the aim of this study was to analyse the biomechanical performance of different types of osteosyntheses alone and in combination with bone cement simulating cyclically high loading conditions of tibial head depression fractures. Lateral tibial head depression fractures (AO: 41-B2.2; Schatzker type III) were created in synthetic bones and stabilized using three different osteosyntheses alone and in combination with a commonly used bone cement (chronOS™): 2 screws, 4 screws in the jail technique and a lateral angle-stable buttress plate. After fixation, the lateral tibial plateau was axially loaded in two, from each other independent testing series: In the first test protocol, 5000 cycles with 500 N and in the end load-to-failure tests were performed. In the second test protocol, the cyclic loading was increased to 1000 N. Parameters of interest were the displacement of the articular fracture fragment, the stiffness and the maximum load. The osteosyntheses revealed a higher stiffness in combination with bone cement compared to the same type of osteosynthesis alone (e.g., 500 N level: 2 screws 383 ± 43 N/mm vs. 2 screws + chronOs 520 ± 108 N/mm, increase by 36%, p < 0.01; 4 screws 368 ± 97 N/mm vs. 4 screws + chronOS 516 ± 109 N/mm, increase by 40%, p < 0.01; plate: 509 ± 73 N/mm vs. plate + chronOs 792 ± 150 N/mm, increase by 56%, p < 0.01). Bone cement reduced the displacement of the plate significantly (500 N level: plate: 8.9 ± 2.8 mm vs. plate + chronOs: 3.1 ± 1.4 mm, reduction by 65%, p < 0.01; 1000 N level: 16.9 ± 3.6 mm vs 5.6 ± 1.3 mm, reduction by 67%, p < 0.01). Thus, the highest stiffness and lowest displacement values were found when using the plate with bone cement in both loading conditions (500 N level: 2 screws + chronOs 3.7 ± 1.3 mm, 4 screws + chronOs 6.2 ± 2.4 mm; 1000 N level: 2 screws + chronOs 6.5 ± 1.2 mm, 4 screws + chronOs 5.7 ± 0.8 mm). From a biomechanical perspective, plate osteosynthesis of tibial head depression fractures should always be combined with bone cement, provides higher stability than 2-screw and 4-screw fixation and is a valid treatment option in cases where extraordinary stability is required.
The aim of this study was to compare two different techniques of performing one-level spondylodesis for thoracolumbar burst fractures using either an autologous iliac crest bone graft (ICBG) or a porous tantalum fusion implant (PTFI). In a prospective nonrandomized study, 44 patients (20 women, 24 men; average age 43.1 +/- 13.2 years) suffering from severe thoracolumbar burst fractures were treated with combined anterior-posterior stabilization. An ICBG was used in 21 cases, and a PTFI was used in the other 23 cases. A two-year clinical and radiographic follow-up was carried out. There were no statistically significant differences in age, sex, localization/classification of the fracture, or visual analog scale (VAS) before injury between the two groups. All 44 patients were followed up for an average period of 533 days (range 173-1567). The sagittal spinal profile was restored by an average of 11.1 degrees (ICBG) vs. 14.3 degrees (PTFI) (monosegmental Cobb angle). Loss of correction until the last follow-up tended to be higher in the patients treated with ICBG than in those treated with PTFI (mean: 2.8 degrees vs. 1.6 degrees). Furthermore, significantly better restoration of the sagittal profile was obtained with the PTFI than with the iliac bone graft at the long-term follow-up (mean: ICBG 7.8 degrees, PTFI 12.3 degrees; p < 0.005). Short-segment posterior instrumentation combined with anterior one-level spondylodesis using either an ICBG or a PTFI resulted in sufficient correction of posttraumatic segmental kyphosis. PTFI might be a good alternative for autologous bone grafting and prevent donor site morbidities.
Hintergrund
Intensiv- und Beatmungskapazitäten sind für die Behandlung COVID-19-erkrankter Patienten essenziell. Unabhängig davon beanspruchen auch schwer verletzte Patienten häufig Intensiv- und Beatmungskapazitäten. Daraus ergibt sich folgende Fragestellung: Führt eine Ausgangsbeschränkung zu einer Reduktion schwer verletzter Patienten, und kann hierdurch mit frei werdenden Intensivkapazitäten gerechnet werden?
Material und Methoden
Es erfolgte eine retrospektive Auswertung schwer verletzter Patienten mit einem Injury Severity Score (ISS) ≥16 zwischen dem 17.03.2020 und 30.04.2020 (landesweiter Shutdown) an einem überregionalen Traumazentrum. Erfasst wurden der Unfallmechanismus, ISS, Versicherungsträger (BG vs. GKV/PKV), ob es sich um einen dokumentierten Suizidversuch handelte, und ob eine operative Intervention innerhalb der ersten 24 h erforderlich war. Als Kontrollgruppe wurden die Daten des gleichen Zeitraums der Jahre 2018 und 2019 ausgewertet.
Ergebnisse
Es konnte keine wesentliche Veränderung bezüglich der Anzahl an schwer verletzten Patienten festgestellt werden (2018 n = 30, 2019 n = 23, 2020 n = 27). Es zeigten sich insgesamt keine deutlichen Veränderungen der absoluten Zahlen bezüglich der Intensivpflichtigkeit in den ersten 24 h und der Beatmungspflichtigkeit beim Verlassen des Schockraums. Die Anzahl an Patienten, die eine Operation innerhalb der ersten 24 h nach Eintreffen im Schockraum benötigten, war 2020 sogar leicht erhöht, jedoch nicht statistisch signifikant. Der durchschnittliche ISS blieb konstant. Bezüglich der Unfallursache zeigte sich 2020 kein Motorradfahrer, der einen nicht berufsgenossenschaftlich versicherten Unfall erlitt (2018 n = 5, 2019 n = 4, 2020 n = 0). Es wurde 2020 ein erhöhter Anteil an Arbeitsunfällen mit einem ISS ≥16 festgestellt (2018: 10 %, 2019: 26,1 %, 2020: 44,4 %).
Diskussion
Eine Ausgangsbeschränkung führte zu keiner Reduktion verletzter- und intensivpflichtiger Patienten am untersuchten Zentrum. Auch unter einer landesweiten Ausgangsbeschränkung muss für dieses Patientenkollektiv eine ausreichende Menge an Intensiv- und OP-Kapazitäten vorgehalten werden. Die Bestätigung dieser Ergebnisse durch Auswertung nationaler Register steht noch aus.
Operative treatment of ruptured pubic symphysis by plating is often accompanied by complications. Trans-obturator cable fixation might be a more reliable technique; however, have not yet been tested for stabilization of ruptured pubic symphysis. This study compares symphyseal trans-obturator cable fixation versus plating through biomechanical testing and evaluates safety in a cadaver experiment. APC type II injuries were generated in synthetic pelvic models and subsequently separated into three different groups. The anterior pelvic ring was fixed using a four-hole steel plate in Group A, a stainless steel cable in Group B, and a titan band in Group C. Biomechanical testing was conducted by a single-leg-stance model using a material testing machine under physiological load levels. A cadaver study was carried out to analyze the trans-obturator surgical approach. Peak-to-peak displacement, total displacement, plastic deformation and stiffness revealed a tendency for higher stability for trans-obturator cable/band fixation but no statistical difference to plating was detected. The cadaver study revealed a safe zone for cable passage with sufficient distance to the obturator canal. Trans-obturator cable fixation has the potential to become an alternative for symphyseal fixation with less complications.
When aiming at cell‐based therapies in osteoarthritis (OA), proinflammatory conditions mediated by cytokines such as IL‐1β need to be considered. In recent studies, the phytoalexin resveratrol (RSV) has exhibited potent anti‐inflammatory properties. However, long‐term effects on 3D cartilaginous constructs under inflammatory conditions with regard to tissue quality, especially extracellular matrix (ECM) composition, have remained unexplored. Therefore, we employed long‐term model cultures for cell‐based therapies in an in vitro OA environment and evaluated effects of RSV. Pellet constructs made from expanded porcine articular chondrocytes were cultured with either IL‐1β (1–10 ng/ml) or RSV (50 μM) alone, or a cotreatment with both agents. Treatments were applied for 14 days, either directly after pellet formation or after a preculture period of 7 days. Culture with IL‐1β (10 ng/ml) decreased pellet size and DNA amount and severely compromised glycosaminoglycan (GAG) and collagen content. Cotreatment with RSV distinctly counteracted the proinflammatory catabolism and led to partial rescue of the ECM composition in both culture systems, with especially strong effects on GAG. Marked MMP13 expression was detected in IL‐1β‐treated pellets, but none upon RSV cotreatment. Expression of collagen type I was increased upon IL‐1β treatment and still observed when adding RSV, whereas collagen type X, indicating hypertrophy, was detected exclusively in pellets treated with RSV alone. In conclusion, RSV can counteract IL‐1β‐mediated degradation and distinctly improve cartilaginous ECM deposition in 3D long‐term inflammatory cultures. Nevertheless, potential hypertrophic effects should be taken into account when considering RSV as cotreatment for articular cartilage repair techniques.