Refine
Has Fulltext
- yes (33)
Is part of the Bibliography
- yes (33)
Year of publication
Document Type
- Journal article (33) (remove)
Language
- English (33) (remove)
Keywords
- radiotherapy (8)
- prostate cancer (6)
- DNA damage (3)
- IGRT (3)
- hypofractionation (3)
- long-term outcome (3)
- rectal cancer (3)
- toxicity (3)
- DNA repair (2)
- Glioblastoma (2)
- Halcyon (2)
- IMRT (2)
- VMAT (2)
- adaptation (2)
- cancer (2)
- cone beam CT (2)
- image-guided radiation therapy (2)
- radiosensitivity (2)
- radiotherapy (RT) (2)
- salvage radiotherapy (2)
- simultaneous integrated boost (2)
- 4D-MRI (1)
- ATM (1)
- Adaptation (1)
- Akt (1)
- BRAF (1)
- Brain cancer (1)
- CD133 (1)
- CIED malfunction; pacemaker (PM) (1)
- CNS cancer (1)
- Corticosteroids (1)
- DNA double strand breaks (1)
- DNA repair protraction (1)
- DNA-PK (1)
- DNS-Reparatur (1)
- DNS-Schädigung (1)
- Glioma stem cells (1)
- High grade glioma (1)
- IR (1)
- NSCLC (1)
- NVP-BEZ235 (1)
- Nestin (1)
- Non-rigid image registration (1)
- Novel PI3K (1)
- Osteopontin (1)
- PI3K (1)
- PSMA (1)
- PSMA PET/CT (1)
- PTEN (1)
- Peripheral blood lymphocytes (1)
- Prostate carcinoma (1)
- Radiosensitivity (1)
- Radiotherapy (1)
- Radiotherapy treatment planning (1)
- Respiratory induced tumor motion (1)
- Synergy (1)
- TGFβ1 (1)
- Temozolomide (1)
- \(\gamma\)h2ax (1)
- accelerated hyperfractionation (1)
- acute toxicity (1)
- adaptive radiotherapy (1)
- adrenal tumours (1)
- adrenocortical carcinoma (ACC) (1)
- altered fractionation (1)
- apoptosis (1)
- auto-planning (1)
- autophagy (1)
- battery depletion (1)
- biochemical relapse free survival (1)
- blood lymphocytes (1)
- cardiac implantable electronic devices (CIED) (1)
- cardiac resynchronization therapy (CRT) (1)
- chemoradiotherapy (1)
- dabrafenib (1)
- deformable image registration (1)
- dominant intraprostatic lesion (1)
- dose accumulation (1)
- dose escalation (1)
- dose evaluation (1)
- dose to OARs (1)
- double arc (1)
- external beam radiotherapy (EBRT) (1)
- foci (1)
- full arc (1)
- glioblastoma (1)
- head and neck cancer (1)
- head and neck squamous cell carcinoma (1)
- high-dose-rate (HDR) brachytherapy (1)
- high-dose-rate brachytherapy boost (1)
- histone H2AX (1)
- hypoxia (1)
- implantable cardioverter defibrillator (ICD) (1)
- in vivo (1)
- individual radiosensitivity (1)
- intensity-modulated radiation therapy (1)
- intensity-modulated radiotherapy (1)
- irradiation (1)
- local control (1)
- lung cancer (1)
- mTOR Inhibitor (1)
- macroscopic recurrence (1)
- megavoltage computed-tomography (1)
- metastasis-directed therapy (1)
- multimodal therapy (1)
- multiple brain metastases (1)
- neck cancer (1)
- neoadjuvant (1)
- oligorecurrence (1)
- oral mucositis (1)
- osteopontin (1)
- outcomes research (1)
- oxidative DNA damage (1)
- partial arc (1)
- perioperative changes (1)
- peripheral blood lymphocytes (1)
- phosphorylation (1)
- plan comparison (1)
- propensity score matching (1)
- prostate Imaging Reporting and Data System (1)
- radiation (1)
- radiosensibility (1)
- re-irradiation (1)
- re-planning (1)
- repair (1)
- risk (1)
- risk score (1)
- setup verification (1)
- single arc (1)
- strategies (1)
- survival (1)
- temozolomide (1)
- thoracic cancer (1)
- transperineal ultrasound (1)
- treatment plan (1)
- variability (1)
- vemurafenib (1)
- whole breast irradiation (1)
- zinc oxide nanoparticles (1)
Institute
- Klinik und Poliklinik für Strahlentherapie (32)
- Comprehensive Cancer Center Mainfranken (3)
- Klinik und Poliklinik für Nuklearmedizin (3)
- Klinik und Poliklinik für Hals-, Nasen- und Ohrenkrankheiten, plastische und ästhetische Operationen (2)
- Medizinische Klinik und Poliklinik I (2)
- Pathologisches Institut (2)
- Theodor-Boveri-Institut für Biowissenschaften (2)
- Frauenklinik und Poliklinik (1)
- Institut für Klinische Epidemiologie und Biometrie (1)
- Institut für Medizinische Strahlenkunde und Zellforschung (1)
Background: There is a lack of predictive models to identify patients at risk of high neoadjuvant chemoradiotherapy (CRT)-related acute toxicity in rectal cancer. Patient and Methods: The CAO/ARO/AIO-04 trial was divided into a development (n = 831) and a validation (n = 405) cohort. Using a best subset selection approach, predictive models for grade 3–4 acute toxicity were calculated including clinicopathologic characteristics, pretreatment blood parameters, and baseline results of quality-of-life questionnaires and evaluated using the area under the ROC curve. The final model was internally and externally validated. Results: In the development cohort, 155 patients developed grade 3–4 toxicities due to CRT. In the final evaluation, 15 parameters were included in the logistic regression models using best-subset selection. BMI, gender, and emotional functioning remained significant for predicting toxicity, with a discrimination ability adjusted for overfitting of AUC 0.687. The odds of experiencing high-grade toxicity were 3.8 times higher in the intermediate and 6.4 times higher in the high-risk group (p < 0.001). Rates of toxicity (p = 0.001) and low treatment adherence (p = 0.007) remained significantly different in the validation cohort, whereas discrimination ability was not significantly worse (DeLong test 0.09). Conclusion: We developed and validated a predictive model for toxicity using gender, BMI, and emotional functioning. Such a model could help identify patients at risk for treatment-related high-grade toxicity to assist in treatment guidance and patient participation in shared decision making.
Differences in stem cell marker and osteopontin expression in primary and recurrent glioblastoma
(2022)
Background
Despite of a multimodal approach, recurrences can hardly be prevented in glioblastoma. This may be in part due to so called glioma stem cells. However, there is no established marker to identify these stem cells.
Methods
Paired samples from glioma patients were analyzed by immunohistochemistry for expression of the following stem cell markers: CD133, Musashi, Nanog, Nestin, octamer-binding transcription factor 4 (Oct4), and sex determining region Y-box 2 (Sox2). In addition, the expression of osteopontin (OPN) was investigated. The relative number of positively stained cells was determined. By means of Kaplan–Meier analysis, a possible association with overall survival by marker expression was investigated.
Results
Sixty tissue samples from 30 patients (17 male, 13 female) were available for analysis. For Nestin, Musashi and OPN a significant increase was seen. There was also an increase (not significant) for CD133 and Oct4. Patients with mutated Isocitrate Dehydrogenase-1/2 (IDH-1/2) status had a reduced expression for CD133 and Nestin in their recurrent tumors. Significant correlations were seen for CD133 and Nanog between OPN in the primary and recurrent tumor and between CD133 and Nestin in recurrent tumors. By confocal imaging we could demonstrate a co-expression of CD133 and Nestin within recurrent glioma cells. Patients with high CD133 expression had a worse prognosis (22.6 vs 41.1 months, p = 0.013). A similar trend was seen for elevated Nestin levels (24.9 vs 41.1 months, p = 0.08).
Conclusions
Most of the evaluated markers showed an increased expression in their recurrent tumor. CD133 and Nestin were associated with survival and are candidate markers for further clinical investigation.
Background:
In recent years attention has focused on \(\gamma\)H2AX as a very sensitive double strand break indicator. It has been suggested that \(\gamma\)H2AX might be able to predict individual radiosensitivity. Our aim was to study the induction and repair of DNA double strand breaks labelled by \(\gamma\)H2AX in a large cohort.
Methods:
In a prospective study lymphocytes of 136 rectal cancer (RC) patients and 59 healthy individuals were ex vivo irradiated (IR) and initial DNA damage was compared to remaining DNA damage after 2 Gy and 24 hours repair time and preexisting DNA damage in unirradiated lymphocytes. Lymphocytes were immunostained with anti-\(\gamma\)H2AX antibodies and microscopic images with an extended depth of field were acquired. \(\gamma\)H2AX foci counting was performed using a semi-automatic image analysis software.
Results:
Distinct increased values of preexisting and remaining \(\gamma\)H2AX foci in the group of RC patients were found compared to the healthy individuals. Additionally there are clear differences within the groups and there are outliers in about 12% of the RC patients after ex vivo IR.
Conclusions:
The \(\gamma\)H2AX assay has the capability to identify a group of outliers which are most probably patients with increased radiosensitivity having the highest risk of suffering radiotherapy-related late sequelae.
Simple Summary
Prostate cancer often relapses after initial radical prostatectomy, and salvage radiotherapy offers a second chance of cure for relapsed patients. Modern imaging techniques, especially prostate-specific membrane antigen positron emission tomography/computed tomography (PSMA PET/CT), enable radiation oncologists to target radiotherapy at the involved sites of disease. In a group of patients, PSMA PET/CT imaging can detect a macroscopic local recurrence with or without locoregional lymph node metastasis. In these cases, an escalation of the radiotherapy dose is often considered for controlling the visible tumor mass. As the evidence for dose-escalated salvage radiotherapy for macroscopic recurrent prostate cancer after PSMA PET/CT imaging is still limited, we address this topic in the current analysis. We found that the outcome of patients with dose-escalated salvage radiotherapy for macroscopic prostate cancer recurrence is encouragingly favorable, while the toxicity is very limited.
Abstract
Background: The purpose of this study was to access the oncological outcome of prostate-specific membrane antigen positron emission tomography (PSMA PET/CT)-guided salvage radiotherapy (SRT) for localized macroscopic prostate cancer recurrence. Methods: Between February 2010 and June 2021, 367 patients received SRT after radical prostatectomy. Out of the 367 screened patients, 111 patients were staged by PSMA PET/CT before SRT. A total of 59 out of these 111 (53.2%) patients were treated for PSMA PET-positive macroscopic prostatic fossa recurrence. Dose-escalated SRT was applied with a simultaneous integrated boost at a median prescribed dose of 69.3 Gy (IQR 69.3–72.6 Gy). The oncological outcome was investigated using Kaplan-Meier and Cox regression analyses. The genitourinary (GU)/gastrointestinal (GI) toxicity evaluation utilized Common Toxicity Criteria for Adverse Events (version 5.0). Results: The median follow-up was 38.2 months. The three-year biochemical progression-free survival rate was 89.1% (95% CI: 81.1–97.8%) and the three-year metastasis-free survival rate reached 96.2% (95% CI: 91.2–100.0%). The cumulative three-year late grade 3 GU toxicity rate was 3.4%. No late grade 3 GI toxicity occurred. Conclusions: Dose-escalated PSMA PET/CT-guided salvage radiotherapy for macroscopic prostatic fossa recurrence resulted in favorable survival and toxicity rates.
Background
International guidelines emphasise the role of radiotherapy (RT) for the management of advanced adrenocortical carcinoma (ACC). However, the evidence for this recommendation is very low.
Methods
We retrospectively analysed all patients who received RT for advanced ACC in five European centres since 2000. Primary endpoint: time to progression of the treated lesion (tTTP). Secondary endpoints: best objective response, progression-free survival (PFS), overall survival (OS), adverse events, and the establishment of predictive factors by Cox analyses.
Results
In total, 132 tumoural lesions of 80 patients were treated with conventional RT (cRT) of 50–60 Gy (n = 20) or 20–49 Gy (n = 69), stereotactic body RT of 35–50 Gy (SBRT) (n = 36), or brachytherapy of 12–25 Gy (BT) (n = 7). Best objective lesional response was complete (n = 6), partial (n = 52), stable disease (n = 60), progressive disease (n = 14). Median tTTP was 7.6 months (1.0–148.6). In comparison to cRT\(_{20-49Gy}\), tTTP was significantly longer for cRT\(_{50-60Gy}\) (multivariate adjusted HR 0.10; 95% CI 0.03–0.33; p < 0.001) and SBRT (HR 0.31; 95% CI 0.12–0.80; p = 0.016), but not for BT (HR 0.66; 95% CI 0.22–1.99; p = 0.46). Toxicity was generally mild and moderate with three grade 3 events. No convincing predictive factors could be established.
Conclusions
This largest published study on RT in advanced ACC provides clear evidence that RT is effective in ACC.
Background:
The aim of this work is to validate the Dynamic Planning Module in terms of usability and acceptance in the treatment planning workflow.
Methods:
The Dynamic Planning Module was used for decision making whether a plan adaptation was necessary within one course of radiation therapy. The Module was also used for patients scheduled for re-irradiation to estimate the dose in the pretreated region and calculate the accumulated dose to critical organs at risk. During one year, 370 patients were scheduled for plan adaptation or re-irradiation. All patient cases were classified according to their treated body region. For a sub-group of 20 patients treated with RT for lung cancer, the dosimetric effect of plan adaptation during the main treatment course was evaluated in detail. Changes in tumor volume, frequency of re-planning and the time interval between treatment start and plan adaptation were assessed.
Results:
The Dynamic Planning Tool was used in 20% of treated patients per year for both approaches nearly equally (42% plan adaptation and 58% re-irradiation). Most cases were assessed for the thoracic body region (51%) followed by pelvis (21%) and head and neck cases (10%). The sub-group evaluation showed that unintended plan adaptation was performed in 38% of the scheduled cases. A median time span between first day of treatment and necessity of adaptation of 17 days (range 4–35 days) was observed. PTV changed by 12 ± 12% on average (maximum change 42%). PTV decreased in 18 of 20 cases due to tumor shrinkage and increased in 2 of 20 cases. Re-planning resulted in a reduction of the mean lung dose of the ipsilateral side in 15 of 20 cases.
Conclusion:
The experience of one year showed high acceptance of the Dynamic Planning Module in our department for both physicians and medical physicists. The re-planning can potentially reduce the accumulated dose to the organs at risk and ensure a better target volume coverage. In the re-irradiation situation, the Dynamic Planning Tool was used to consider the pretreatment dose, to adapt the actual treatment schema more specifically and to review the accumulated dose.
This retrospective, single-institutional study investigated long-term outcome, toxicity and health-related quality of life (HRQoL) in meningioma patients after radiotherapy. We analyzed the data of 119 patients who received radiotherapy at our department from 1997 to 2014 for intracranial WHO grade I-III meningioma. Fractionated stereotactic radiotherapy (FSRT), intensity modulated radiotherapy (IMRT) or radiosurgery radiation was applied. The EORTC QLQ-C30 and QLQ-BN20 questionnaires were completed for assessment of HRQoL. Overall survival (OS) for the entire study group was 89.6% at 5 years and 75.9% at 10 years. Local control (LC) at 5 and 10 years was 82.4% and 73.4%, respectively. Local recurrence was observed in 22 patients (18.5%). Higher grade acute and chronic toxicities were observed in seven patients (5.9%) and five patients (4.2%), respectively. Global health status was rated with a mean of 59.9 points (SD 22.3) on QLQ-C30. In conclusion, radiotherapy resulted in very good long-term survival and tumor control rates with low rates of severe toxicities but with a deterioration of long-term HRQoL.
Background
The purpose of this study was to compare automatically generated VMAT plans to find the superior beam configurations for Pinnacle3 Auto-Planning and share “best practices”.
Methods
VMAT plans for 20 patients with head and neck cancer were generated using Pinnacle3 Auto-Planning Module (Pinnacle3 Version 9.10) with different beam setup parameters. VMAT plans for single (V1) or double arc (V2) and partial or full gantry rotation were optimized. Beam configurations with different collimator positions were defined. Target coverage and sparing of organs at risk were evaluated based on scoring of an evaluation parameter set. Furthermore, dosimetric evaluation was performed based on the composite objective value (COV) and a new cross comparison method was applied using the COVs.
Results
The evaluation showed a superior plan quality for double arcs compared to one single arc or two single arcs for all cases. Plan quality was superior if a full gantry rotation was allowed during optimization for unilateral target volumes. A double arc technique with collimator setting of 15° was superior to a double arc with collimator 60° and a two single arcs with collimator setting of 15° and 345°.
Conclusion
The evaluation showed that double and full arcs are superior to single and partial arcs in terms of organs at risk sparing even for unilateral target volumes. The collimator position was found as an additional setup parameter, which can further improve the target coverage and sparing of organs at risk.
Purpose: This study analyses a large number of cancer patients with CIEDs for device malfunction and premature battery depletion by device interrogation after each radiotherapy fraction and compares different guidelines in regard to patient safety. Methods: From 2007 to 2022, a cohort of 255 patients was analyzed for CIED malfunctions via immediate device interrogation after every RT fraction. Results: Out of 324 series of radiotherapy treatments, with a total number of 5742 CIED interrogations, nine device malfunctions (2.8%) occurred. Switching into back-up/safety mode and software errors occurred four times each. Once, automatic read-out could not be performed. The median prescribed cumulative dose at planning target volume (PTV) associated with CIED malfunction was 45.0 Gy (IQR 36.0–64.0 Gy), with a median dose per fraction of 2.31 Gy (IQR 2.0–3.0 Gy). The median maximum dose at the CIED at time of malfunction was 0.3 Gy (IQR 0.0–1.3 Gy). No correlation between CIED malfunction and maximum photon energy (p = 0.07), maximum dose at the CIED (p = 0.59) nor treatment localization (p = 0.41) could be detected. After excluding the nine malfunctions, premature battery depletion was only observed three times (1.2%). Depending on the national guidelines, 1–9 CIED malfunctions in this study would have been detected on the day of occurrence and in none of the cases would patient safety have been compromised. Conclusion: Radiation-induced malfunctions of CIEDs and premature battery depletion are rare. If recommendations of national safety guidelines are followed, only a portion of the malfunctions would be detected directly after occurrence. Nevertheless, patient safety would not be compromised.
Evaluation of set up error detection by a transperineal ultrasound in comparison with a cone beam CT (CBCT) based system in external beam radiation therapy (EBRT) of prostate cancer.
Methods: Setup verification was performed with transperineal ultrasound (TPUS) and CBCT for 10 patients treated with EBRT for prostate cancer. In total, 150 ultrasound and CBCT scans were acquired in rapid succession and analyzed for setup errors. The deviation between setup errors of the two modalities was evaluated separately for each dimension.
Results: A moderate correlation in lateral, vertical and longitudinal direction was observed comparing the setup errors. Mean differences between TPUS and CBCT were (−2.7 ± 2.3) mm, (3.0 ± 2.4) mm and (3.2 ± 2.7) mm in lateral, vertical and longitudinal direction, respectively. The mean Euclidean difference between TPUS and CBCT was (6.0 ± 3.1) mm. Differences up to 19.2 mm were observed between the two imaging modalities. Discrepancies between TPUS and CBCT of at least 5 mm occurred in 58 % of monitored treatment sessions.
Conclusion: Setup differences between TPUS and CBCT are 6 mm on average. Although the correlation of the setup errors determined by the two different image modalities is rather week, the combination of setup verification by CBCT and intrafraction motion monitoring by TPUS imaging can use the benefits of both imaging modalities.