Refine
Has Fulltext
- yes (30)
Is part of the Bibliography
- yes (30) (remove)
Year of publication
Document Type
- Journal article (30)
Keywords
- fracture (4)
- surgery (4)
- Coronavirus (2)
- Injury Severity Score (2)
- Intensivkapazitäten (2)
- Pandemie (2)
- Polytrauma (2)
- arthritis (2)
- classification (2)
- fixation (2)
Institute
- Klinik und Poliklinik für Unfall-, Hand-, Plastische und Wiederherstellungschirurgie (Chirurgische Klinik II) (30)
- Institut für diagnostische und interventionelle Radiologie (Institut für Röntgendiagnostik) (3)
- Klinik und Poliklinik für Anästhesiologie (ab 2004) (3)
- Institut für Anatomie und Zellbiologie (2)
- Lehrstuhl für Orthopädie (2)
- Abteilung für Funktionswerkstoffe der Medizin und der Zahnheilkunde (1)
- Klinik und Poliklinik für Allgemein-, Viszeral-, Gefäß- und Kinderchirurgie (Chirurgische Klinik I) (1)
- Neurochirurgische Klinik und Poliklinik (1)
- Physiologisches Institut (1)
- Urologische Klinik und Poliklinik (1)
EU-Project number / Contract (GA) number
- 309962 (1)
Background
Barbed suture material offers the possibility of knotless flexor tendon repair, as suggested in an increasing number of biomechanical studies. There are currently two different absorbable barbed suture products available, V-Loc™ and Stratafix™, and both have not been compared to each other with regard to flexor tendon repair. The purpose of this study was to evaluate both suture materials for primary stability under static and cyclic loading in a biomechanical ex vivo model.
Methods
Forty fresh porcine flexor digitorum profundus tendons were randomized in two groups. A four-strand modified Kessler suture technique was used to repair the tendon either with a 3–0 V-Loc™ or 3–0 Stratafix™ without a knot. Parameters of interest were mode of failure, 2-mm gap formation force, displacement, stiffness and maximum load under static and cyclic testing.
Results
The maximum load was 42.3 ± 7.2 for the Stratafix™ group and 50.7 ± 8.8 N for the V-Loc™ group. Thus, the ultimate tensile strength was significantly higher for V-Loc™ (p < 0.05). The 2-mm gap occurred at 24.8 ± 2.04 N in the Stratafix™ group in comparison to 26.5 ± 2.12 N in the V-Loc™ group (n.s.). Displacement was 2.65 ± 0.56 mm in the V-Loc™ group and 2.71 ± 0.59 mm in the Stratafix™ group (n.s.). Stiffness was 4.24 ± 0.68 (N/mm) in the V-Loc™ group and 3.85 ± 0.55 (N/mm) the Stratafix™ group (n.s.). Those measured differences were not significant.
Conclusion
V-Loc™ demonstrates a higher maximum load in tendon reconstruction. The differences in 2-mm gap formation force, displacement and stiffness were not significant. Hereby, the V-Loc™ has an advantage when used as unidirectional barbed suture for knotless flexor tendon repair.
Purpose
Displaced midshaft clavicular fractures can be treated conservatively as well as operatively by titan elastic nail (TEN) or plate fixation. This survey was performed to evaluate the clinical results of each treatment method and elaborate advantages or possible complications of each modality.
Methods
Between 2008 and 2013, 102 patients were prospectively included in our study—37 patients for conservative treatment with a rucksack bandage for 4 to 6 weeks, 41 patients for plate osteosynthesis, and 24 for intramedullary stabilization with TEN. Disabilities of the Arm, Shoulder and Hand (DASH), Constant Murley Score (CMS), and visual analog scale (VAS) for pain and function as well as time of invalidity were recorded over a 1-year period.
Results
The clinical data collected reveals that all three different therapies lead to good or excellent clinical results after 1 year. However, one can observe advantages of operative treatment in comparison to conservative therapy in some characteristics.
Conclusion
Our data shows that there are several indications where operative treatment has advantages compared to conservative treatment. In special fracture types (Robinson 2B1), TEN gives the best results. Plate fixation is extraordinarily sufficient in pain reduction within the first 5 weeks and indicated in more-part fractures (Robinson 2B2). Nevertheless, conservative treatment is always a good and promising way to treat clavicular fractures, so that individual indications and thorough patient informative talks are inevitable.
Background
Suture pretension during tendon repair is supposed to increase the resistance to gap formation. However, its effects on the Bunnell suture technique are unknown. The purpose of this study was to determine the biomechanical effects of suture pretension on the Bunnell and cross-lock Bunnell techniques for tendon repair.
Methods
Eighty porcine hindlimb tendons were randomly assigned to four different tendon repair groups: those repaired with or without suture pretension using either a simple Bunnell or cross-lock Bunnell technique. Pretension was applied as a 10 % shortening of the sutured tendon. After measuring the cross-sectional diameter at the repair site, static and cyclic biomechanical tests were conducted to evaluate the initial and 5-mm gap formation forces, elongation during cyclic loading, maximum tensile strength, and mode of failure. The suture failure mechanism was also separately assessed fluoroscopically in two tendons that were repaired with steel wire.
Results
Suture pretension was accompanied by a 10 to 15 % increase in the tendon diameter at the repair site. Therefore, suture pretension with the Bunnell and cross-lock Bunnell repair techniques noticeably increased the resistance to initial gap formation and 5-mm gap formation. The tension-free cross-lock Bunnell repair demonstrated more resistance to initial and 5-mm gap formation, less elongation, and higher maximum tensile strength than the tension-free Bunnell repair technique. The only difference between the tensioned cross-lock Bunnell and tensioned Bunnell techniques was a larger resistance to 5-mm gap formation with the cross-lock Bunnell technique. Use of the simple instead of cross-lock suture configuration led to failure by suture cut out, as demonstrated fluoroscopically.
Conclusion
Based on these results, suture pretension decreases gapping and elongation after tendon repair, and those effects are stronger when using a cross-lock, rather than a regular Bunnell suture. However, pretension causes an unfavorable increase in the tendon diameter at the repair site, which may adversely affect wound healing.
Background
The Goutallier Classification is a semi quantitative classification system to determine the amount of fatty degeneration in rotator cuff muscles. Although initially proposed for axial computer tomography scans it is currently applied to magnet-resonance-imaging-scans. The role for its clinical use is controversial, as the reliability of the classification has been shown to be inconsistent. The purpose of this study was to compare the semi quantitative MRI-based Goutallier Classification applied by 5 different raters to experimental MR spectroscopic quantitative fat measurement in order to determine the correlation between this classification system and the true extent of fatty degeneration shown by spectroscopy.
Methods
MRI-scans of 42 patients with rotator cuff tears were examined by 5 shoulder surgeons and were graduated according to the MRI-based Goutallier Classification proposed by Fuchs et al. Additionally the fat/water ratio was measured with MR spectroscopy using the experimental SPLASH technique. The semi quantitative grading according to the Goutallier Classification was statistically correlated with the quantitative measured fat/water ratio using Spearman’s rank correlation.
Results
Statistical analysis of the data revealed only fair correlation of the Goutallier Classification system and the quantitative fat/water ratio with R = 0.35 (p < 0.05). By dichotomizing the scale the correlation was 0.72. The interobserver and intraobserver reliabilities were substantial with R = 0.62 and R = 0.74 (p < 0.01).
Conclusion
The correlation between the semi quantitative MRI based Goutallier Classification system and MR spectroscopic fat measurement is weak. As an adequate estimation of fatty degeneration based on standard MRI may not be possible, quantitative methods need to be considered in order to increase diagnostic safety and thus provide patients with ideal care in regard to the amount of fatty degeneration. Spectroscopic MR measurement may increase the accuracy of the Goutallier classification and thus improve the prediction of clinical results after rotator cuff repair. However, these techniques are currently only available in an experimental setting.
Background
Tibial head depression fractures demand a high level of fracture stabilization to prevent a secondary loss of reduction after surgery. Elderly individuals are at an increased risk of developing these fractures, and biomechanical investigations of the fractures are rare. Therefore, the aim of this study was to systematically analyze different types of osteosyntheses in combination with two commonly used bone substitutes.
Methods
Lateral tibial head depression fractures were created in synthetic bones. After reduction, the fractures were stabilized with eight different treatment options of osteosynthesis alone or in combination with a bone substitute. Two screws, 4 screws and a lateral buttress plate were investigated. As a bone substitute, two common clinically used calcium phosphate cements, Norian® Drillable and ChronOS™ Inject, were applied. Displacement of the articular fracture fragment (mm) during cyclic loading, stiffness (N/mm) and maximum load (N) in Load-to-Failure tests were measured.
Results
The three different osteosyntheses (Group 1: 2 screws, group 2: 4 screws, group 3: plate) alone revealed a significantly higher displacement compared to the control group (Group 7: ChronOS™ Inject only) (Group 1, 7 [p < 0.01]; group 2, 7 [p = 0.04]; group 3, 7 [p < 0.01]). However, the osteosyntheses in combination with bone substitute exhibited no differences in displacement compared to the control group. The buttress plate demonstrated a higher normalized maximum load than the 2 and 4 screw osteosynthesis. Comparing the two different bone substitutes to each other, ChronOS™ inject had a significantly higher stiffness and lower displacement than Norian® Drillable.
Conclusions
The highest biomechanical stability under maximal loading was provided by a buttress plate osteosynthesis. A bone substitute, such as the biomechanically favorable ChronOS™ Inject, is essential to reduce the displacement under lower loading.
Background:
Bone-ligament-bone grafts for reconstruction of the scapholunate ligament are a valuable tool to prevent disease progression to carpal collapse. Locally available grafts do not require an additional donor site. The first extensor compartment was evaluated biomechanically regarding its possible use as an autograft.
Methods:
Twelve native fresh-frozen, human cadaver specimens were tested by applying axial tension in a Zwick Roell machine. Load to failure, transplant elongation, and bony avulsion were recorded. The load to failure was quantitated in newtons (N) and the displacement in length (millimeters). Parameters were set at distinct points as start of tension, 1 mm stretch and 1.5 mm dissociation, failure and complete tear, and were evaluated under magnified visual control. Although actual failure occurred at higher tension, functional failure was defined at a stretch of 1.5 mm.
Results:
Mean load at 1 mm elongation was 44.1 ± 28 N and at 1.5 mm elongation 57.5 ± 42 N. Failure occurred at 111 ± 83.1 N. No avulsion of the bony insertion was observed. Half the transplants failed in the central part of the ligament, while the rest failed near the insertion but not at the insertion itself. Analysis of tension strength displayed a wide range from 3.8 to 83.7 N/mm at a mean of 33.4 ± 28.4 N/mm.
Conclusions:
The biomechanical tensile properties of the first dorsal extensor compartment are similar to those of the dorsal part of the scapholunate ligament. A transplant with a larger bone stock and a longer ligament may display an advantage, as insertion is possible in the dorsal, easily accessible part of the carpal bones rather than in the arête-like region adjacent to the insertion of the scapholunate ligament. In this study, 1.5 mm lengthening of the bone–ligament–bone transplant was defined as clinical failure, as such elongation will cause severe gapping and is considered as failure of the transplant.
Background:
Propeller flaps require torsion of the vascular pedicle of up to 180 degrees. Contrary to free flaps, where the relevance of an intact vascular pedicle has been documented, little is known regarding twisted pedicles of propeller flaps. As secondary surgeries requiring undermining of the flap are common in the extremities, knowledge regarding the necessity to protect the pedicle is relevant. The aim of this study was a long-term evaluation of the patency of vascular pedicle of propeller flaps.
Methods:
In a retrospective clinical study, 22 patients who underwent soft-tissue reconstruction with a propeller flap were evaluated after 43 months. A Doppler probe was used to locate and evaluate the patency of the vascular pedicle of the flap.
Results:
The flaps were used in the lower extremity in 19 cases, on the trunk in 3 cases. All flaps had healed. In all patients, an intact vascular pedicle could be found. Flap size, source vessel, or infection could therefore not be linked to an increased risk of pedicle loss.
Conclusions:
The vascular pedicle of propeller flaps remains patent in the long term. This allows reelevation and undermining of the flap. We therefore recommend protecting the pedicle in all secondary cases to prevent later flap loss.
Multiple-level amputations of the upper extremity represent a surgical challenge generally only attempted in young patients. This case demonstrates a successful replantation in an elderly woman. The postoperative course was complicated by disseminated intravascular coagulopathy most likely due to inadequate resuscitation. Hand trauma is often underestimated in its general severity. Upper extremity amputations need to be handled similar to polytraumatized patients.
Background:
The integrity of the flexor tendon pulley apparatus is crucial for unimpaired function of the digits. Although secondary reconstruction is an established procedure in multi-pulley injuries, acute reconstruction of isolated, closed pulley ruptures is a rare occurrence. There are 3 factors influencing the functional outcome of a reconstruction: gapping distance between tendon and bone (E-space), bulkiness of the reconstruction, and stability. As direct repair is rarely done, grafts are used to reinforce the pulley. An advantage of the first extensor retinaculum graft is the synovial coating providing the possibility to be used both as a direct graft with synovial coating or as an onlay graft after removal of the synovia when the native synovial layer is present.
Methods:
A graft from the first dorsal extensor compartment is used as an onlay graft to reinforce the sutured A4 pulley. This technique allows reconstruction of the original dimensions of the pulley system while stability is ensured by anchoring the onlay graft to the bony insertions of the pulley.
Results:
Anatomical reconstruction can be achieved with this method. The measured E-space remained 0 mm throughout the recovery, while the graft incorporated as a slim reinforcement of the pulley, displaying no bulkiness.
Conclusions:
The ideal reconstruction should provide synovial coating and sufficient strength with minimal bulk. Early reconstruction using an onlay graft offers these options. The native synovial lining is preserved and the graft is used to reinforce the pulley.
The coronal unicondylar fracture of the distal femur (AO 33-B3) is a rare intraarticular injury within the weight bearing area of the knee, initially described by Albert Hoffa in 1904. We report an unusual combination of a Hoffa fracture with lateral patellar dislocation in a young adult. Our patient sustained the injury by a sudden twist of his leg during sports. He presented clinically with knee swelling, dislocation of the patella, and localized tenderness; unable to bare weight. After plane radiograph confirmed the injury, manual reduction of the patella was done by hyperextension of the knee and medialward pressure. Afterwards, a CT scan and MRI were conducted. The injury was surgically treated with lag-screws, locking-plate and MPFL-reconstruction.