Filtern
Volltext vorhanden
- ja (27)
Gehört zur Bibliographie
- ja (27)
Erscheinungsjahr
- 2011 (27) (entfernen)
Dokumenttyp
- Dissertation (27) (entfernen)
Schlagworte
- Kernspintomografie (3)
- MRI (3)
- Molekularstrahlepitaxie (3)
- NMR-Bildgebung (3)
- NMR-Tomographie (3)
- Spintronik (3)
- DFB laser (2)
- DFB-Laser (2)
- Drei-Fünf-Halbleiter (2)
- Galliumarsenidlaser (2)
Institut
- Physikalisches Institut (27) (entfernen)
This thesis investigated the potential of Compressed Sensing (CS) applied to Magnetic Resonance Imaging (MRI). CS is a novel image reconstruction method that emerged from the field of information theory. The framework of CS was first published in technical reports in 2004 by Candès and Donoho. Two years later, the theory of CS was published in a conference abstract and two papers. Candès and Donoho proved that it is possible, with overwhelming probability, to reconstruct a noise-free sparse signal from incomplete frequency samples (e.g., Fourier coefficients). Hereby, it is assumed a priori that the desired signal for reconstruction is sparse. A signal is considered “sparse“ when the number of non-zero elements is significantly smaller than the number of all elements. Sparsity is the most important foundation of CS. When an ideal noise-free signal with few non-zero elements is given, it should be understandably possible to obtain the relevant information from fewer Fourier coefficients than dictated by the Nyquist-Shannon criterion. The theory of CS is based on noise-free sparse signals. As soon as noise is introduced, no exact sparsity can be specified since all elements have signal intensities that are non-zero. However, with the addition of little or moderate noise, an approximate sparsity that can be exploited using the CS framework will still be given. The ability to reconstruct noisy undersampled sparse MRI data using CS has been extensively demonstrated. Although most MR datasets are not sparse in image space, they can be efficiently sparsified by a sparsifying transform. In this thesis, the data are either sparse in the image domain, after Discrete Gradient transformation, or after subtraction of a temporally averaged dataset from the data to be reconstructed (dynamic imaging). The aim of this thesis was to identify possible applications of CS to MRI. Two different algorithms were considered for reconstructing the undersampled sparse data with the CS concept. The Nonlinear Conjugate Gradient based technique with a relaxed data consistency constraint as suggested by Lustig et al. is termed Relaxed DC method. An alternative represents the Gradient or Steepest Descent algorithm with strict data consistency and is, therefore, termed the Strict DC method. Chapter 3 presents simulations illustrating which of these two reconstruction algorithms is best suited to recover undersampled sparse MR datasets. The results lead to the decision for the Strict DC method as reconstruction technique in this thesis. After these simulations, different applications and extensions of CS are demonstrated. Chapter 4 shows how CS benefits spectroscopic 19F imaging at 7 T, allowing a significant reduction of measurement times during in vivo experiments. Furthermore, it allows highly resolved spectroscopic 3D imaging in acceptable measurement times for in vivo applications. Chapter 5 introduces an extension of the Strict DC method called CS-CC (CS on Combined Coils), which allows efficient processing of sparse undersampled multi-coil data. It takes advantage of a concept named “Joint Sparsity“, which exploits the fact that all channels of a coil array detect the same sparse object weighted with the coil sensitivity profiles. The practical use of this new algorithm is demonstrated in dynamic radial cardiac imaging. Accurate reconstructions of cardiac motion in free breathing without ECG triggering were obtained for high undersampling factors. An Iterative GRAPPA algorithm is introduced in Chapter 6 that can recover undersampled data from arbitrary (Non-Cartesian) trajectories and works solely in the Cartesian plane. This characteristic makes the proposed Iterative GRAPPA computationally more efficient than SPIRiT. Iterative GRAPPA was developed in a preceding step to combine parallel imaging with CS. Optimal parameters for Iterative GRAPPA (e.g. number of iterations, GRAPPA kernel size) were determined in phantom experiments and verified by retrospectively undersampling and reconstructing a radial cardiac cine dataset. The synergistic combination of the coil-by-coil Strict DC CS method and Iterative GRAPPA called CS-GRAPPA is presented in Chapter 7. CS-GRAPPA allows accurate reconstruction of undersampled data from even higher acceleration factors than each individual method. It is a formulation equivalent to L1-SPIRiT but computationally more efficient. Additionally, a comparison with CS-CC is given. Interestingly, exploiting joint sparsity in CS-CC is slightly more efficient than the proposed CS-GRAPPA, a hybrid of parallel imaging and CS. The last chapter of this thesis concludes the findings presented in this dissertation. Future applications expected to benefit from CS are discussed and possible synergistic combinations with other existing MR methodologies for accelerated imaging are also contemplated.
This work deals with nonlinear optics with wavefront controlled ultra-short laser pulses. The effects studied are self-phase modulation due to filamentation of ultra-short laser pulses and high-order harmonic generation in a jet of noble gas. Additionally, a way to optimize the spectral brilliance of the high-order harmonic source is studied by measuring the spectrum and wavefront of the generated XUV beam.
Ziel der Arbeit war die Entwicklung von lateral gekoppelten DFB-Halbleiterlasern für Hochleistungsanwendungen. Besonderes Augenmerk war dabei auf hohe COD-Schwellen und schmale Fernfeldverteilungen gerichtet. Ausgehend von einem LOC-Design wurden Simulationsrechnungen durchgeführt und ein neues Epitaxiedesign mit einer 2.5 μm dicken LOC, in welcher die aktive Schicht asymmetrisch positioniert ist, entwickelt. Durch die asymmetrische Anordnung der aktiven Schicht kann die im Falle von lateral gekoppelten DFB-Lasern sehr kritische Kopplung der Lichtmode an das modenselektive Gitter gewährleistet werden. Zudem reichen die Ausläufer der Lichtmode in diesem Design weiter in den Wellenleiter hinab als dies bei herkömmlichen Wellenleitern der Fall ist, so dass sich die Fernfeldeigenschaften der Laser verbessern. Die Fernfeldverteilungen solcher Laser weisen Halbwertsbreiten von 14° in lateraler und nur 19° in transversaler Richtung auf. Im Vergleich mit Standardstrukturen konnte die Ausdehnung des transversalen Fernfeldes also um mehr als 50 % reduziert werden. Außerdem ergibt sich eine nahezu runde Abstrahlcharakteristik, was die Einkopplungseffizienz in optische Systeme wie Glasfasern oder Linsen signifikant verbessert. Unter Ausnutzung der entwickelten Epitaxiestruktur mit asymmetrischer LOC wurde ein neues Lateraldesign entwickelt. Es handelt sich hierbei um Wellenleiterstege welche im Bereich der Facetten eine Verjüngung aufweisen. Durch diese wird die optische Mode tief in die 2.5 μm dicke Wellenleiterschicht geführt, welche sie in transversaler Richtung komplett ausfüllt. Durch den größeren Abstand der Lasermode vom Wellenleitersteg ergibt sich zudem eine deutliche schwächere laterale Führung, so dass sich die Mode auch parallel zur aktiven Schicht weiter ausdehnt. Die Lichtmode breitet sich folglich über eine deutlich größere Fläche aus, als dies bei einem gleichbleibend breiten Wellenleitersteg der Fall ist. Die somit signifikant kleinere Leistungsdichte auf der Laserfacette ist gleichbedeutend mit einem Anstieg der COD-Schwelle der Laser der im Einzelnen von den jeweiligen Designparametern von Schicht- und Lateralstruktur abhängig ist. Außerdem bewirkt die in lateraler und transversaler Richtung deutlich schwächere Lokalisation der Mode eine weitere Abnahme der Halbwertsbreiten der Laserfernfelder. Durch die im Vergleich zu herkömmlichen Laserstrukturen schwächere Lokalisation der Lichtmode im Bereich der Facetten ergeben sich äußerst schmale Fernfelder. Ein 1800 μm langer Laser, dessen Stegbreite über 200 μm hinweg auf 0.4 μm verringert wurde, zeigt Halbwertsbreiten von 5.2° in lateraler und 13.0° in transversaler Richtung. Damit sind die Fernfelder dieser Laser bedeutend kleiner als die bislang vorgestellter Laserdioden mit LOC. Die Geometrie der Taperstrukturen bestimmt, wie vollständig sich die Mode in den unteren Wellenleiterbereich ausbreiten kann und nimmt damit Einfluss auf die Laserfernfelder. Im CW-Modus durchgeführte Messungen an Lasern mit Taperstrukturen zeigen maximale Ausgangsleistung von 200 mW bevor die Laser in thermisches Überrollen übergehen. Bei einer Ausgangsleistung von 185 mW beträgt das Seitenmodenunterdrückungsverhältnis 33 dB. Im gepulsten Modus (50 ns Pulsdauer, 1MHz Wiederholungsrate) betriebene Laser zeigen hohe COD-Schwellen von mehreren hundert bis hin zu 1600 mW, die eine deutliche Abhängigkeit von der Endbreite der Taperstrukturen zeigen: Mit abnehmender Taperbreite ergibt sich eine starke Zunahme der COD-Schwelle. An einem 1800 μm langen Laser mit 200 μm langen Taperstrukturen die eine Endbreite von 0.3 μm aufweisen konnte eine COD-Schwelle von 1.6 W nachgewiesen werden. Im Gegensatz zu anderen Ansätzen, die ebenfalls longitudinal und lateral mono-modige DFB-Laser mit hohen Ausgangsleistungen zum Ziel haben, kann jedoch bei dem hier präsentierten Konzept aufgrund des Einsatzes von lateralen DFB-Gittern auf eine Unterbrechung des epitaktischen Wachstums verzichtet werden. Dies vereinfacht die Herstellung der Schichtstrukturen deutlich. Die hier vorgestellten Konzepte sind mit weiteren üblichen Vorgehensweisen zur Herstellung von Hochleistungslaserdioden, wie z.B. speziellen Facettenreinigungs- und Passivierungsverfahren oder Materialdurchmischung im Facettenbereich, kombinierbar. Zudem kann das hier am Beispiel des InGaAs/GaAs Materialsystems entwickelte Konzept auf alle zur Herstellung von Halbleiterlaserdioden üblichen Materialsysteme übertragen werden und eröffnet so eine völlig neue, material- und wellenlängenunabhängige Möglichkeit Abstrahlcharakteristik und Ausgangsleistung von Laserdioden zu optimieren.
Magnetic resonance imaging (MRI) is a medical imaging method that involves no ionizing radiation and can be used non-invasively. Another important - if not the most important - reason for the widespread and increasing use of MRI in clinical practice is its interesting and highly flexible image contrast, especially of biological tissue. The main disadvantages of MRI, compared to other widespread imaging modalities like computed tomography (CT), are long measurement times and the directly resulting high costs. In the first part of this work, a new technique for accelerated MRI parameter mapping using a radial IR TrueFISP sequence is presented. IR TrueFISP is a very fast method for the simultaneous quantification of proton density, the longitudinal relaxation time T1, and the transverse relaxation time T2. Chapter 2 presents speed improvements to the original IR TrueFISP method. Using a radial view-sharing technique, it was possible to obtain a full set of relaxometry data in under 6 s per slice. Furthermore, chapter 3 presents the investigation and correction of two major sources of error of the IR TrueFISP method, namely magnetization transfer and imperfect slice profiles. In the second part of this work, a new MRI thermometry method is presented that can be used in MRI-safety investigations of medical implants, e.g. cardiac pacemakers and implantable cardioverter-defibrillators (ICDs). One of the major safety risks associated with MRI examinations of pacemaker and ICD patients is RF induced heating of the pacing electrodes. The design of MRI-safe (or MRI-conditional) pacing electrodes requires elaborate testing. In a first step, many different electrode shapes, electrode positions and sequence parameters are tested in a gel phantom with its geometry and conductivity matched to a human body. The resulting temperature increase is typically observed using temperature probes that are placed at various positions in the gel phantom. An alternative to this local thermometry approach is to use MRI for the temperature measurement. Chapter 5 describes a new approach for MRI thermometry that allows MRI thermometry during RF heating caused by the MRI sequence itself. Specifically, a proton resonance frequency (PRF) shift MRI thermometry method was combined with an MR heating sequence. The method was validated in a gel phantom, with a copper wire serving as a simple model for a medical implant.
In dieser Arbeit habe ich mich hauptsächlich mit der optischen Spektroskopie im sichtbaren bis nahinfraroten Bereich an Akzeptoren für organische bulk-heterojunction Polymer-Fulleren Solarzellen beschäftigt. Dabei führte ich sowohl Untersuchungen an reinen Fullerenproben als auch Gemischen dieser mit Polymeren durch. Ergänzend sind Messungen zur Morphologie, den Spinzuständen und der Solarzellenleistung erfolgt. Erreicht werden sollte, die generelle Eignung neuartiger Akzeptoren für organische Solarzellen festzustellen, die photoinduzierten spektroskopischen Signaturen von optisch angeregten Anionen auf Fullerenen verschiedener Größe zu finden und zu interpretieren sowie zum Abschluss die Abläufe der Ladungsträgergeneration in Polymer:Lu3N@C80 Solarzellen nachzuvollziehen und dadurch die Ursache der vergleichsweise geringen Stromdichte in diesen Zellen zu verstehen, die 25 % geringer ist als in P3HT:PC60BM Solarzellen. Die Ergebnisse sind, dass C70-C70 Dimer Fullerene sehr gute Akzeptoren darstellen, die neben einer etwas besseren Absorption als C60 basierte Akzeptoren im Bereich um 500 nm sehr gute Fähigkeiten als Elektronenakzeptoren zeigen. Die Messung an Fullerenen verschiedener Größe, um Anionensignaturen zu finden, hat deutliche Signaturen für C60- bei 1.18 eV und für C70- bei 0.92 eV erbracht. Weniger einfach zu finden und interpretieren sind die Signaturen von C80- und C84-. Aufgrund der geringen Signalstärke sowie spezieller Eigenheiten der zur Verfügung stehenden Fullerene konnte ich nur einen ungefähren Bereich von 0.7~eV bis 0.4~eV für die Anionensignaturen abschätzen. Allerdings zeigt sich für alle Fullerene eine Rotverschiebung der Anionensignaturen hin zu niedrigeren Energien mit steigender Zahl der Kohlenstoffatome pro Fulleren. Die umfangreichste Untersuchung habe ich an dem Molekül Lu3N@C80 in seiner Funktion als Elektronenakzeptor in P3HT:Lu3N@C80 Solarzellen gemacht. Während das Molekül in Kombination mit P3HT eine hohe Leerlaufspannung von 835 mV erzeugt, ergeben diese Zellen geringere Stromdichten. Mein Ziel war es, die Prozesse zu identifizieren und zu verstehen, die dafür verantwortlich zeichnen. Aus der Kombination verschiedener Messmethoden, ergänzt mit generellen Erkenntnissen zu endohedralen Fullerenen aus der Literatur, ließ es zu, einen intramolekularen Elektronentransfer von den Lutetiumatomen innerhalb des C80 auf das Fulleren als Ursache zu identifizieren. Die in dieser Arbeit gewonnenen Daten liefern weitere Indizien, dass die Verwendung von C70 basierten Fullerenen eine gute Option zur Verbesserung des Wirkungsgrads von organischen Solarzellen sein kann, trotz der höheren Herstellungskosten. Die gefundenen Anionensignaturen auf den Fullerenen bieten einen weiteren Ansatz, die Anregungsabläufe in verschiedenen bulk-heterojunctions über spektroskopische Messungen nachzuvollziehen. Abschließend habe ich mit meinen Messungen an Lu3N@C80 einen generell zu beachtenden Effekt aufgezeigt, der bei der zukünftigen Synthese funktionaler Akzeptoren ähnlicher Art berücksichtigt werden sollte, um eine optimale Leistungsfähigkeit solcher Moleküle zu gewährleisten. Während die Projekte über die Dimer Akzeptoren und das Lu3N@C80 Molekül abgeschlossen wurden, sind bei der Untersuchung der Anionen, speziell auf großen Fullerenen, noch Fragen offen, und es wären zusätzliche Nachweise wünschenswert. Dies könnte mit spinsensitiven und zeitaufgelösten Messmethoden, die am Lehrstuhl vorhanden sind, an den hier schon vorgestellten Materialien erreicht werden. Eine weitere Möglichkeit wäre es zu versuchen, PC81$BM zu bekommen und dies zu untersuchen, auch in Gemischen mit noch mehr verschiedenen Polymeren mittels photoinduzierter Absorption.
In this work the epitaxial growth and characterization of the half-metallic ferromagnet NiMnSb was presented. NiMnSb crystallizes in the C1b structure which is similar to the zinc blende structure from widely used III-V semiconductors. One special property of NiMnSb is the theoretical 100% spin-polarization at the Fermi edge. This makes it a perfect candidate for spintronic experiments and the material of choice for building novel spintronic devices. Another important topic in this work were the magnetic properties of NiMnSb, especially the low magnetic damping of the grown thin films. All grown layers were fabricated with the technique of MBE. The layer stacks for all different experiments and devices were grown on InP substrate in (001) or (111)B orientation. Before the NiMnSb layer a buffer layer of undoped (In,Ga)As was grown. Additional for some samples on InP(111)B, a Si doped (In,Ga)As layer was grown on top of the undoped (In,Ga)As layer. The dopant concentration of this n-doped layer was determined by ETCH-CV. All layers were investigated by structural and the NiMnSb layer additional by magnetic properties. For the structural investigation the in-situ technique RHEED and ex-situ tool HRXRD were used. RHEED observations showed a good quality of the grown buffer and half-metallic ferromagnet layers on both orientations. These results were strengthened by the HRXRD measurement. The vertical lattice constant could be determined. The received value of a(NiMnSb_vertical) = 5.925 Å for NiMnSb on InP(001) is in good agreement to the value a(NiMnSb_Lit) = 5.903 Å found in literature [Cas55]. For NiMnSb on InP(111)B a vertical lattice constant of a(NiMnSb_vertikal) = 6.017 Å could be determined. The horizontal lattice constant of the buffer and the half-metallic ferromagnet layer could be determined as the same of the substrate. For NiMnSb this conclusion is only valid up to a thickness of ≈40nm. To increase this maximum thickness, NiMnSb samples were grown on InP(001) substrates and capped with Ti/Au layers. Afterwards a reciprocal space map of the (533) reflex was drawn with GIXRD at the synchrotron beamline BW2 of HASYLAB [Kum07]. It has been shown that the critical thickness is more than doubled by depositing a Ti/Au capping directly after growth of NiMnSb without breaking the ultrahigh vacuum (UHV). The magnetic properties were determined with FMR experiments and SQUID measurements. The received magnetic damping parameter α from a 40nm thick NiMnSb layer on InP(001) could be determined to 3.19e−3 along [1-10]. The resulting line width of our NiMnSb layers on InP(001) is more than 4.88 times smaller than measured before [Hei04]. Another result is the direction dependence of the damping. It has been measured that the difference of the damping is changed by more than 42% when rotating the applied field by 45° from [1-10] to [100].With SQUID we measured a saturation magnetization of a 40nm thick NiMnSb layer as 4µB. NiMnSb layers on InP(111)B substrate where also measured with FMR with a surprising result. These layers not only showed a decreasing in the anisotropy field with increasing thickness but also an uniaxial anisotropy. This behaviour can be explained with defects on these samples. With an AFM triangle-like defects were measured. These defects originated from the buffer layer and influenced the magnetic properties. Another part of this work is dedicated to the behaviour of NiMnSb at temperatures around 80K. With our samples, no phase transition can be observed in the data of the Hall, anomalous Hall term and resistivity. The last part of this work discusses different spintronic devices build with our NiMnSb layers. In a first device the magnetization acts on the current. This Giant Magneto Resistance (GMR) device consisted of InP:S(001) - 180nm undoped (In,Ga)As - 40nm NiMnSb - 10nm Cu - 6nm NiFe - 10nm Ru in current perpendicular to plane (CPP) geometry. We received a Magneto-Resistance-Ratio of 3.4%. In a second device the current acts on the magnetization and makes use of the spin torque phenomena. This so called Spin Torque Oscillator (STO) emitted frequencies in the GHz range (13.94GHz - 14.1GHz). The last fabricated device is based on the magnetic vortex phenomena. For switching the core polarity the gyrotropic frequencies f + = 254MHz f − = 217MHz and a total static magnetic field of only mµ0H = 65mT were necessary. The reversal efficiency has been determined as better than 99% [Lou09].
Das Wissen um die strukturellen und elektronischen Eigenschaften verborgener Metall-Organik-Grenzflächen ist entscheidend für die Optimierung und Verbesserung der Leistungsfähigkeit von auf organischen Halbleitern basierenden Bauteilen. In der vorliegenden Arbeit wurde ein Delaminationskonzept für das Ultrahochvakuum (UHV) umgesetzt und optimiert, mit dessen Hilfe an Modellsystemen verborgene Grenzflächen für oberflächensensitive Methoden zugänglich gemacht und im Anschluss hinsichtlich ihrer elektronischen und topographischen Eigenschaften untersucht wurden. Die Erfahrungen und Ergebnisse dieser Arbeit stellen im Bezug auf Untersuchungen und die Optimierung von organischen Bauteilen und ihre verborgenen Grenzflächen einen neuartigen Zugang dar. Der erste Schwerpunkt der Arbeit befasste sich am Beispiel von verborgenen Metall/NTCDA- und Metall/ PTCDA-Grenzflächen mit der Frage, wie verborgene Grenzflächen erfolgreich für oberflächensensitive Methoden zugänglich gemacht werden können. Nach einer Eruierung eines Klebstoffs, dessen Eigenschaften den Anforderungen hinsichtlich der Festigkeit, Verarbeitung und UHV-Tauglichkeit genügt, konnte gezeigt werden, dass es mit ausreichender Sorgfalt möglich ist, einen unmittelbaren Zugang zu verborgenen Grenzflächen zu erhalten. Es konnten dabei Kontakte von ca. 10 × 15 mm2 Größe offengelegt werden. Dabei zeigte sich auch, dass der Klebstoff für die Qualität der Delamination eine entscheidende Rolle spielt. Auf der einen Seite bestimmt das Klebeverhalten des Klebstoffs die Größe der möglichen Delaminationsfläche, und auf der anderen Seite bestimmt seine chemische Zusammensetzung das Ausgas- und Diffusionsverhalten, welche Einfluss auf den Kontaminationsgrad der delaminierten Grenzflächen haben. Mit Hilfe von dickeren Metallschichten konnte erreicht werden, dass leichter zu verarbeitende Klebstoffe (Klebestreifen) für die Delamination verborgener Grenzflächen verwendet werden können. Auch konnte die gesamte Prozedur, eine verborgene Grenzfläche zu präparieren und zu delaminieren, erfolgreich in-situ im UHV durchgeführt werden. Als schwierig zeigte sich die thermische Desorption von Molekülschichten von delaminierten Metallkontakten. Bei der thermischen Ausdünnung (100-250_C) wird unweigerlich die Morphologie des darunter liegende Metallkontakts verändert. Zudem wurden Konzepte getestet, mit welchen PTCDA-Schichten von delaminierten Kontakten mittels Lösungsmitteln entfernt wurden, um im Anschluss daran die Kontakttopographie zu untersuchen. Es wird vermutet, dass der Einfluss der Lösungsmittel auf den delaminierten Kontakt zwar gegeben, jedoch gering ist. Im zweiten Schwerpunkt dieser Arbeit konnten für verborgene Metall(Au,Ag)/PTCDA und Ag/NTCDA-Grenzflächen nach ihrer Delamination einige Gemeinsamkeiten festgestellt werden: Nach der Delamination der Top-Kontakte befinden sich auf den Metallkontakten inhomogene Molekülschichten. Dabei waren auf den PTCDA-bedeckten Kontakten dickere Schichten (4-5 ML PTCDA auf Ag-Kontakt) und auf den NTCDA-bedeckten Kontakten große Bereiche von mindestens 2 mm im Durchmesser mit Monolagen vorhanden. Auch topographisch zeigten sich Gemeinsamkeiten. So wiesen die mit Molekülmultilagen bedeckten Bereiche glatte Oberflächen auf, während die Metalloberflächen selbst zerklüftete, mäanderartige und raue Oberflächen aufwiesen. Eine weitere Gemeinsamkeit war, dass der Klebstoff die PE-spektroskopische Untersuchung der Valenzzustände erheblich erschwerte. Des Weiteren konnte die Molekülschicht zwar thermisch ausgedünnt werden, jedoch konnten danach keine Valenzzustände untersucht werden. Als letzter gemeinsamer Gesichtspunkt waren topographische Einflüsse des Klebstoffs, welcher durch seine mikro- wie makroskopischen thermischen Verformungen und Blasenbildung massiv die topographische Struktur des Kontakts verändert. Bei der Untersuchung von in-situ delaminierten verborgenen Grenzflächen stand zunächst die Metall(Au,Ag)/PTCDA-Grenzflächen im Fokus. Bei delaminierten Au/PTCDA-Kontakten war die offengelegte Grenzfläche nach der Delamination nicht intakt, und es fanden sich Löcher in der Metallschicht mit mehreren μm Durchmesser. Durch diese waren Bestandteile des Klebstoffs (VACSEAL) photoelektronenspektroskopisch und lichtmikroskopisch auf der verborgenen Grenzfläche zu sehen, die gerade in der UV-Photoelektronenspektroskopie (UPS) eine Untersuchung der Valenzzustände dünner PTCDA-Schichten besonders erschweren. Das HOMO der PTCDA-Multilage liegt bei delaminierten Au/PTCDA-Kontakten bei etwa 2,3eV. Die Untersuchung von Ag/PTCDA-Kontakten zeigte intakte Metallkontaktfilme nach der Delamination. Es konnte zudem die Molekülschicht thermisch bei 260_C auf 2-4 Monolagen erfolgreich ausgedünnt werden, so dass Valenzzustände untersucht werden konnten. Der Klebstoff erschwerte jedoch auch hier die Untersuchung. Aufgrund verbreiterter Spektren konnten die Lagen des HOMO und FLUMO des in-situ delaminierten und ausgedünnten Ag/PTCDA-Kontakts ungefähr bei 1,9 eV bzw. 0,7 eV bestimmt werden. Weiterhin wurden offengelegte Ag/NTCDA-Grenzflächen untersucht. Bei Ag/ NTCDAKontakten ist es gelungen, durch sukzessives Erhöhen der Metallschichtdicke den Einfluss des Klebstoffs zu minimieren bzw. gänzlich ohne diesen auszukommen. Bereits ab Silberschichtdicken von 2,5 μm können verborgene Grenzflächen mit geschickter Technik so delaminiert werden, dass sich Kontaktbereiche ohne Klebstoffanteile ergeben. Dabei wurde ein Drittel des Kontakts verklebt und die restlichen zwei Drittel standen nach der Delamination frei von Klebstoffbestandteilen für Untersuchungen zur Verfügung. Ein weiterer Erfolg bezüglich der Delamination war nicht nur, dass leichter zu verarbeitende Klebstoffe (Klebestreifen) verwendet werden konnten, sondern vor allem, dass es gelang, Ag/NTCDA-Kontakte zu delaminieren, deren Molekülschichtdicken im Monolagenbereich vorlagen. Damit konnte zum ersten Mal die direkte Molekül-Metall-Wechselwirkung an der verborgenen Grenzfläche untersucht werden, ohne dass der Kontakt für die Klebstoffaushärtung geheizt und die NTCDA-Schicht thermisch desorbiert werden musste. Das mit UPS ermittelte HOMO lag dabei bei 2,3 eV und das FLUMO bei 0,6 eV. Zudem wurde eine Austrittsarbeit von 4,9 eV ermittelt. Ferner konnte die Valenzstruktur eines vollständig in-situ präparierten und delaminierten Kontakts im UHV untersucht werden. Die Ergebnisse zeigten keinerlei Unterschiede zu den Kontakten, die für die Verklebung an Luft gebracht wurden. Ferner wurde ein Modell vorgestellt, mit dem erklärt werden kann, weshalb sich nach der Delamination nur einige wenige Moleküllagen auf dem Metallkontakt befinden. Bei den allgemeinen topographischen Untersuchungen ergab sich, dass die delaminierten Ag/NTCDA-Kontakte relativ rau mit einer RMS-Rauheit im Bereich von 18-24 nm und einer Skewness von 0,5 bis 1,5 waren. Ebenfalls wurden zwei Auffälligkeiten von delaminierten Ag/NTCDA-Kontakten untersucht: Die erste waren topographische Strukturen, die im Lichtmikroskop Löcher in der Metallschicht zu sein schienen. Diese erwiesen sich im Rasterkraftmikroskop (RKM) als lokal begrenzte Bereiche mit erhöhter Rauheit. Die zweite topographische Auffälligkeit waren Bereiche auf den delaminierten Ag/NTCDA-Kontakten, die im Lichtmikroskop als dunkle Flecken verschiedener Größe erschienen. Bei RKM-Untersuchungen konnten die dunklen Bereiche als NTCDA-Kristallite identifiziert werden, deren Dicke zwischen 500-600 nm lag. Zum Abschluss soll an dieser Stelle noch angemerkt werden, dass die Übertragung der Erfahrungen und Ergebnisse dieser Arbeit auf andere Systeme möglich ist. Das hier erfolgreich angewandte Delaminationskonzept besticht durch einfache Handhabung und Untersuchungsmöglichkeiten im UHV. Gerade im Hinblick auf eine vollständige in-situ Präparation und Delamination gibt es jedoch noch erhebliches Optimierungspotential, bis die Untersuchung von verborgenen Grenzflächen anderer Systeme, die besonders empfindlich gegenüber Umgebungsbedingungen sind, erfolgreich durchgeführt werden und zur Optimierung von "organischen" Bauteilen beitragen können.
In this work, the trap states in the conjugated polymer P3HT, often used as electron donor in organic bulk heterojunction solar cells, three commonly used fullerene based electron acceptors and P3HT:PC61BM blends were investigated. Furthermore, the trap states in the blend were compared with these of the pure materials. Concerning the lifetime of organic solar cells the influence of oxygen on P3HT and P3HT:PC61BM blends was studied. The experimental techniques used to investigate the trap states in the organic semiconductors were (fractional) thermally stimulated current (TSC) and current based deep level transient spectroscopy (Q-DLTS). Fractional TSC measurements on P3HT diodes revealed a quasi-continuous trap distribution. The distribution suggested two different traps in P3HT with approximately Gaussian energy distributions and maxima at about 50 meV and 105 meV. Thereby, the former was attributed to the tail states within the regular Gaussian density of states due to the low activation energy. The latter, deeper traps, however, exhibited a strong dependence on oxygen. Exposure of the P3HT diodes to oxygen, ambient air and synthetic (dry) air all revealed an increase of the deeper traps density with exposure time in the same manner. While the lower limit of the trap density in non aged P3HT samples was in the range of (1.0 − 1.2)×10^22 m^−3, it was more than doubled after an exposure of 50 h to air. An increase of the trap density with oxygen exposure time was also seen in the Q-DLTS measurements accompanied with an increase of the temperature dependence of the emission rates, indicating an enhanced formation of deeper traps. Due to the raise in density of the deeper traps, the charge carrier mobility in P3HT significantly decreased, as revealed by photo-CELIV measurements, resulting in a loss in mobility of about two orders of magnitude after 100 h exposure to synthetic air. The increased trap density was attributed to p-doping of P3HT by the transfer of an electron to adsorbed oxygen. This effect was partially reversible by applying vacuum to the sample for several hours or, more significantly, by a thermal treatment of the devices in nitrogen atmosphere. The trap states in the methanofullerenes PC61BM, bisPC61BM and PC71BM were investigated by TSC measurements. PC61BM yielded a broad quasi-continuous trap distribution with the maximum of the distribution at about 75 meV. The comparison of the TSC spectra of the three methanofullerenes exhibited significant differences in the trap states with higher activation energies of the most prominent traps in bisPC61BM and PC71BM compared to PC61BM. This probably originates from the different isomers bisPC61BM and PC71BM consist of. Each of the isomers yields different LUMO energies, where the lower ones can act as traps. The lower limit of the trap density of all of the three investigated fullerene derivatives exhibited values in the order of 10^22 m^−3, with the highest for bisPC61BM and the lowest for PC61BM. By applying fractional TSC measurements on P3HT:PC61BM solar cells, it was shown that the trap distribution in the blend is a superposition of the traps in pure P3HT and PC61BM and additional deeper traps in the range of about 250 meV to 400 meV. The origin of these additional traps, which can not be related to the pure materials, was attributed to a higher disorder in the blend and P3HT/PC61BM interfaces. This conclusion was supported by standard TSC and Q-DLTS measurements performed on pristine and annealed P3HT:PC61BM blends, exhibiting a higher ratio of the deep traps in the pristine samples. The lower limit of the trap density of the investigated annealed solar cells was in the range of (6−8)×10^22 m^−3, which was considerably higher than in the pure materials. The influence of oxygen on P3HT:PC61BM solar cells was investigated by exposure of the devices to synthetic air under specific conditions. Exposure of the solar cells to oxygen in the dark resulted in a strong decrease in the power conversion efficiency of 60 % within 120 h, which was only caused by a loss in short-circuit current. Simultaneous illumination of the solar cells during oxygen exposure strongly accelerated the degradation, resulting in an efficiency loss of 30 % within only 3 h. Thereby, short-circuit current, open-circuit voltage and fill factor all decreased in the same manner. TSC measurements revealed an increase of the density of deeper traps for both degradation conditions, which resulted in a decrease of the mobility, as investigated by CELIV measurements. However, these effects were less pronounced than in pure P3HT. Furthermore, an increase of the equilibrium charge carrier density with degradation time was observed, which was attributed to oxygen doping of P3HT. With the aid of macroscopic simulations, it was shown that the doping of the solar cells is the origin of the loss in short-circuit current for both degradation conditions.
Das Ziel dieser Arbeit war es, Methoden und Techniken für die morphologische und funktionelle Bildgebung der menschlichen Lunge mittels Kernspintomographie bei Feldstärken von 0,2 Tesla und 1,5 Tesla zu entwickeln und zu optimieren. Bei 0,2 Tesla wurde mittels der gemessenen Relaxationszeiten T1 und T2* eine 2D und eine 3D FLASH Sequenz zur Untersuchung der Lungenmorphologie optimiert. Sauerstoffgestützte Messungen der Relaxationszeiten T1 und T2* sowie eine SpinLabeling Sequenz liefern funktionelle Informationen über den Sauerstofftransfer und die Perfusion der Lungen. Bei 1,5 Tesla wurde die Lungenperfusion mittels MR-Kontrastmittel mit einer 2D und einer 3D Sequenz unter Verwendung der Präbolus Technik quantifiziert. Zudem wurden zwei MR-Navigationstechniken entwickelt, die es ermöglichen Lungenuntersuchungen unter freier Atmung durchzuführen und aus den Daten artefaktfreie Bilder zu rekonstruieren. Diese Techniken können in verschiedenste Sequenzen für die Lungenbildgebung implementiert werden, ohne dass die Messzeit dadurch signifikant verlängert wird.
Der große Fortschritt der Halbleitertechnologie ermöglichte es in den letzten Jahren quantenoptische Phänomene nicht mehr nur ausschließlich an Atomen, sondern auch in einer Festkörpermatrix zu beobachten. Von besonderem Interesse sind dabei Phänomene der Licht-Materie-Wechselwirkung im Kontext der Quantenelektrodynamik in Kavitäten. Die äußerst aktive Forschung auf diesem Gebiet rührt daher, dass diese Phänomene bei der Realisierung neuartiger Lichtquellen für die Quanteninformationstechnologie benötigt werden. Die Verwirklichung von solchen speziellen Lichtquellen auf Halbleiterbasis besitzt entscheidende Vorteile im Hinblick auf die praktische Anwendbarkeit aufgrund der potentiell hohen Skalierbarkeit und Effizienz. Jedoch kann die erforderliche Licht-Materie-Wechselwirkung nur in qualitativ sehr hochwertigen Halbleiterstrukturen mit quasi nulldimensionalem Ladungsträger- und Lichteinschluss erfolgen. Hierbei wurden in den letzten Jahren enorme technologische Fortschritte bei der Prozessierung von Mikrokavitäten mit Quantenpunkten in der aktiven Schicht sowie bei der Beobachtung der gewünschten Licht-Materie-Wechselwirkung erzielt. Allerdings erfolgten diese Untersuchungen in erster Linie an optisch mithilfe eines externen Lasers angeregten Strukturen, wohingegen für die Praxis ein elektrischer Betrieb wünschenswert ist. Die für die elektrische Anregung von solchen Mikrostrukturen notwendige Kontaktierung kann darüber hinaus zur effizienten Manipulation der Emissionseigenschaften der Quantenemitter mittels eines elektrischen Feldes eingesetzt werden. Vor diesem Hintergrund werden im Rahmen dieser Arbeit die optischen und elektrischen Eigenschaften von kontaktierten Quantenpunkt-Mikrosäulenkavitäten eingehend untersucht. Ausgangspunkt dieser Mikrokavitäten sind planare Schichtstrukturen auf der Basis von GaAs und AlAs mit InGaAs-Quantenpunkten mit variierendem Indiumgehalt in der aktiven Schicht. Der Schwerpunkt der Untersuchungen lag hierbei auf vertikal elektrisch kontaktierten Mikrosäulenresonatoren, deren Aufbau vertikal emittierenden Laserdioden ähnelt. Die Besonderheit der neuartigen Kontaktierung liegt darin, dass aufgrund der Strominjektion durch die Seitenwände im oberen Bereich des Mikrosäulenresonators die Facette der Struktur frei von jeglichem absorbierenden Material gehalten wird. Hierdurch kann eine effiziente Lichtauskopplung gewährleistet werden. Des Weiteren wurde auch ein Verfahren zur seitlichen Kontaktierung von undotierten Mikrosäulenresonatoren entwickelt und optimiert, was eine spezielle Manipulation der Quantenpunktemission in einem lateralen elektrischen Feld erlaubt. Als Untersuchungsmethode wird bei allen Experimenten in erster Linie die Mikrolumineszenzspektroskopie bei tiefen Temperaturen verwendet und durch die Methode der Photostromspektroskopie sowie Autokorrelationsmessungen erster und zweiter Ordnung ergänzt ...