Purpose: To treat patients with tricompartimental knee osteoarthritis (OA), a customized cruciate-retaining total knee arthroplasty (CCR-TKA) system can be used, including both individualized instrumentation and implants. The objective of this monocentric cohort study was to analyze patient-reported and functional outcomes in a series of patients implanted with the second generation of this customized implant. Methods: At our arthroplasty center, we prospectively recruited a cohort of patients with tricompartmental gonarthrosis to be treated with total knee replacement (TKA) using a customized cruciate-retaining (CCR) implant design. Inclusion criteria for patients comprised the presence of intact posterior cruciate and collateral ligaments and a knee deformity that was restricted to <15° varus, valgus, or flexion contracture. Patients were assessed for their range of motion (ROM), Knee Society Score (KSS), Western Ontario and McMaster University osteoarthritis index (WOMAC), and short form (SF)-12 physical and mental scores, preoperatively, at 3 and 6 months, as well as at 1, 2, 3, and 5 years of follow-up (FU) postoperatively. Results: The average age of the patient population was 64 years (range: 40–81), the average BMI was 31 (range: 23–42), and in total, 28 female and 45 male patients were included. Implant survivorship was 97.5% (one septic loosening) at an average follow-up of 2.5 years. The KSS knee and function scores improved significantly (p < 0.001) from, respectively, 41 and 53 at the pre-operative visit, to 92 and 86, respectively, at the 5-year post-operative time point. The SF-12 Physical and Mental scores significantly (p < 0.001) improved from the pre-operative values of 28 and 50, to 50 and 53 at the 5-year FU, respectively. Patients experienced significant improvements in their overall knee range of motion, from 106° at the preoperative visit to 122°, on average, 5 years postoperatively. The total WOMAC score significantly (p < 0.001) improved from 49.1 preoperatively to 11.4 postoperatively at 5-year FU. Conclusions: Although there was no comparison to other implants within this study, patients reported high overall satisfaction and improvement in functional outcomes within the first year from surgery, which continued over the following years. These mid-term results are excellent compared with those reported in the current literature. Comparative long-term studies with this device are needed. Level of evidence 3b (individual case–control study).
Die vorliegende Studie mit insgesamt 73 Patienten untersucht das klinische und funktionelle Outcome nach Implantation einer kreuzbanderhaltenden patientenspezifischen Kniegelenkstotalendoprothese vom Typ Conformis iTotal® CR G2. Es handelt sich um eine monozentrische retrospektive und deskriptive Studie zu klinischen und radiologischen Ergebnissen zwei, drei sowie fünf Jahre postoperativ. Es wurden zu Vergleichszwecken auch präoperative Daten erhoben und ausgewertet. Neben klinischen und radiologischen Untersuchungen wurden durch die Verwendung des „Knee Society Scores“, des „WOMAC Osteoarthritis Index“ und des „SF-12 Health Survey“-Fragebogens die Ergebnisse bezüglich Kniefunktion, Schmerz und Lebensqualität erhoben. Die Untersuchungen für das mittelfristige Outcome erfolgten im Zeitraum zwischen November 2012 und Januar 2017 unter standardisierten Bedingungen.
Insgesamt zeigte sich im Vergleich zum präoperativen Ausgangswert eine statistisch signifikante Verbesserung aller erhobenen Scores sowie eine verbesserte Funktionalität.
Der Vergleich mit anderen veröffentlichten Studien zeigte eine bessere gesamte Implantationsqualität als bei standardisierten Prothesen. Verglichen mit anderen individualisierten Prothesen sind die Ergebnisse ebenfalls etwas besser bzw. zum Teil gleichwertig. Im Gegensatz zu unserer Studie verbesserten sich die Scores bei den meisten Vergleichsstudien nicht signifikant. Im direkten Vergleich mit den einzelnen Punktzahlen der Scores erzielte die Conformis iTotal® CR G2 Prothese in unserer Studie sehr gute, zum Teil deutlich bessere Ergebnisse.
Trotz der sehr guten und vielversprechenden Ergebnisse sollte aufgrund der deutlich aufwendigeren und strahlenbelastenden präoperativen Maßnahmen, die zur Implantation einer solchen Prothese notwendig sind, sowie der teilweise eingeschränkten Aussagekraft dieser Studie weitere Langzeitstudien bezüglich Funktionalität und Haltbarkeit der Conformis iTotal® CR G2 Prothese durchgeführt werden.