Refine
Has Fulltext
- yes (85)
Is part of the Bibliography
- yes (85)
Year of publication
Document Type
- Journal article (85) (remove)
Language
- English (85) (remove)
Keywords
- melt electrowriting (10)
- 3D printing (9)
- additive manufacturing (8)
- biofabrication (7)
- melt electrospinning writing (7)
- bioprinting (6)
- hyaluronic acid (6)
- bioink (4)
- magnesium phosphate cement (4)
- phytic acid (4)
- polycaprolactone (4)
- breast cancer (3)
- calcium phosphate cement (3)
- chondrogenic differentiation (3)
- electrohydrodynamics (3)
- extracellular matrix (3)
- hydrogels (3)
- melt electrowriting (MEW) (3)
- tissue engineering (3)
- MSC (2)
- angiogenesis (2)
- arteriovenous loop (2)
- baghdadite (2)
- biocompatibility (2)
- biomedical materials (2)
- bone (2)
- bone cement (2)
- calcium phosphate (2)
- cortical neurons (2)
- dual-stage crosslinking (2)
- electrohydrodynamic (2)
- in vitro (2)
- inflammation (2)
- printability (2)
- rheology (2)
- scaffold (2)
- shape fidelity (2)
- therapy (2)
- (AB)\(_{n}\) segmented copolymers (1)
- 316L stainless-steel (1)
- 3D electrophysiology (1)
- 3D microfiber (1)
- 3D model systems (1)
- 3D neuronal networks (1)
- 3D powder printing (1)
- 3D scaffolds (1)
- 3D tumor model (1)
- ACPC (1)
- ALI culture (1)
- Adenovirus (1)
- Bone marrow (1)
- Breast cancer (1)
- Ca\(^{2+}\)-Imaging (1)
- Cartilage (1)
- Chondrogenesis (1)
- ECM (1)
- FluidFM technology (1)
- Fluorescence Microscopy (1)
- Gene therapy (1)
- HA modifiedCNF membranes (1)
- HEMA (1)
- Hypertrophy (1)
- Janus fibers (1)
- MPI (1)
- MPS (1)
- Mesenchymal stem cell (1)
- NLRP3 (1)
- Normal breast (1)
- PTEN (1)
- Primary cell lines (1)
- QCM (1)
- RHO (1)
- ROCK (1)
- SOX9 (1)
- Schiff base chemistry (1)
- Staphylococcus aureus / drug effects (1)
- Stem cells plasticity (1)
- Tissue engineering (1)
- Vancomycin / administration & dosage (1)
- Vancomycin / chemistry (1)
- Vancomycin / pharmacology (1)
- WST test (1)
- ZIP (1)
- acrylate-endcapped urethane-based polymer (AUP) (1)
- actin (1)
- acute myeloid leukaemia (1)
- adhesion dynamics (1)
- adipose tissue (1)
- adipose-derived stromal cells (1)
- agarose (1)
- alginate (1)
- alveolar‐capillary barrier (1)
- amoeboid cell migration (1)
- animal model (1)
- anisotropic porous structures (1)
- anti-bacterial agents / administration & dosage (1)
- anti-bacterial agents / chemistry (1)
- anti-bacterial agents / pharmacology (1)
- arthritis (1)
- artificial bones (1)
- astrocytes (1)
- atomic force microscopy (1)
- axial vascularization (1)
- azlactone (1)
- balloon kyphoplasty (1)
- bending strength (1)
- bio-printability (1)
- bioceramic (1)
- biocompatible Materials (1)
- biodegradable polymers (1)
- biofabricated vascular graft (1)
- bioinorganic (1)
- bioinspired interface (1)
- bioinspired membrane (1)
- biological models (1)
- biomaterial ink (1)
- biomaterials (1)
- biomechanical evaluation (1)
- biomechanics (1)
- biomedical engineering (1)
- biophysics (1)
- biosensor (1)
- biosensors (1)
- blood-plasma (1)
- bone adhesive (1)
- bone and cartilage tissue engineering (1)
- bone critical size defect (1)
- bone graft substitutes (1)
- bone replacement material (1)
- bone wires (1)
- brain cancer (1)
- breast cancer model (1)
- brushite cement (1)
- calcaneus (1)
- calcium phosphate cements (1)
- calcium-phosphate (1)
- carbon fiber reinforcement (1)
- cardiovascular pharmacology (1)
- cartilage (1)
- cartilage repair (1)
- cell coagulation (1)
- cell counting (1)
- cell elongation (1)
- cell guidance (1)
- cell migration (1)
- cell morphology (1)
- cell printing (1)
- cell self-assembled monolayers (1)
- cell transplantation (1)
- cell viability (1)
- cement (1)
- ceramics (1)
- chemokines (1)
- chondrocyte (1)
- chondrocytes (1)
- chondroprogenitors (1)
- click chemistry (1)
- co-culture (1)
- coatings (1)
- cochlea (1)
- collagen sponge (1)
- combination of physical vapor deposition and electrochemical etching (1)
- composite material (1)
- compressive strength (1)
- connective tissue (1)
- crosslinked coating (1)
- cryostructured scaffolds (1)
- cyclic mechanical stretch (1)
- cyclic stretch (1)
- cyclic testing (1)
- cyto-compatibility (1)
- cytotoxicity (1)
- damage tolerant cement (1)
- deafness (1)
- defects (1)
- defined humanized test system (1)
- definition (1)
- degradable bone substitutes (1)
- degradable implant (1)
- detachment force quantification (1)
- dicalcium phosphate cement (1)
- differentation (1)
- digitization (1)
- dihydrate cement (1)
- disease models (1)
- drillability (1)
- drillable bone cement (1)
- drop on demand (1)
- drug delivery (1)
- drug liberation (1)
- dual setting (1)
- dual setting system (1)
- durotaxis (1)
- electroactive (1)
- electroactive polymers (1)
- electron microscopy (1)
- electrospinning (1)
- eletrhydrodynamic (1)
- embedded templating (1)
- endothelial progenitor cells (1)
- expression (1)
- extrusion of hiMPC-containing bioinks alginate + collagen type I (1)
- extrusion-based 3D printing (1)
- factor-I (1)
- farringtonite (1)
- fiber (1)
- fiber reinforcement (1)
- fibers (1)
- fiber–matrix interaction (1)
- fixation (1)
- focal adhesions (1)
- force (1)
- fracture (1)
- free radical polymerization (1)
- functionalization (1)
- gels (1)
- gels and hydrogels (1)
- gentamicin-loaded poly (methyl methacrylate) bone cement (1)
- granules (1)
- growth (1)
- guided bone regeneration (1)
- heart-failure (1)
- hemocompatibility (1)
- heterotypic scaffold design (1)
- human iPSC-derived mesodermal cells (hiMPCs) (1)
- human macrophages (1)
- human neutrophil elastase (HNE) (1)
- hybrid fabrication (1)
- hybrid materials (1)
- hybrid polymers (1)
- hydraulic reactivity (1)
- hydrogel (1)
- hydrogel formation (1)
- hydroxyapatite (1)
- hypoxia (1)
- imaging agents (1)
- immunomodulation (1)
- implants (1)
- in vitro cell‐stretch model (1)
- in-vivo Micro-Computed Tomography (1)
- inflammatory response (1)
- inner ear (1)
- inositol hexaphosphate (1)
- intercellular adhesion (1)
- interface control (1)
- iron release (1)
- lectin (1)
- left-ventricular function (1)
- load to failure testing (1)
- lung cell model (1)
- macrophage polarization (1)
- macrophages (1)
- magnetic properties (1)
- magnetoactive materials (1)
- materials testing (1)
- mature cell-cell contacts (1)
- mechanical activation (1)
- mechanical performance (1)
- mechanical properties (1)
- medical-grade poly(ε-caprolactone) (1)
- medicine (1)
- melanoma (1)
- melt electrowriting (1)
- melt electrofibrillation (1)
- microfibers (1)
- microfibres (1)
- microfluidics (1)
- microstructures (1)
- microvasculature (1)
- migration (1)
- minipig (1)
- modelling (1)
- morphology controls (1)
- mucin (1)
- multilayered vessel wall with intimate, media and adventitia (1)
- nanofibers (1)
- nanostructures (1)
- nanotopographical surfaces (1)
- networks (1)
- neurite growth (1)
- organ-on-a-chip (1)
- organoids (1)
- osseointegration (1)
- osteoblasts (1)
- osteochondral defect (1)
- osteoporosis (1)
- oxidation (1)
- particle study (1)
- peptide conjugation (1)
- peptide immobilization (1)
- phase conversion (1)
- photo-crosslinking (1)
- photopolymerization (1)
- physicochemical characterization (1)
- plasticizers (1)
- platelet-adhesion (1)
- platelets (1)
- poly(2-ethyl-2-oxazoline) (1)
- poly(ethylene glycol) (1)
- poly(lactide-co-glycolide) (1)
- polyacrylic acid (1)
- polyethylene glycol (1)
- polymer processing (1)
- polymer-analogue functionalization (1)
- polymeric matrix (1)
- polymers (1)
- polyoxazoline (1)
- polyoxazolines (1)
- porosity (1)
- pre-crosslinking (1)
- primary vascular smooth muscle‐like cells (vSMCs) (1)
- proliferation (1)
- prostheses and implants (1)
- protein adsorption (1)
- radiopacity (1)
- rat model (1)
- recruitment (1)
- remodelling (1)
- repair (1)
- rhBMP–2 (1)
- sacrificial printing (1)
- sanders (1)
- scaffolds (1)
- screw (1)
- self-assembled monolayers (1)
- serial block face EM (1)
- setting reaction (1)
- shear stress (1)
- shear thinning (1)
- signaling (1)
- silicones (1)
- sodium alginate (1)
- solution electrospinning (1)
- spheroids (1)
- spinning (1)
- stanfieldite (1)
- starPEG hydrogel (1)
- stem cells (1)
- stimulation (1)
- stress (1)
- sugar glass printing (1)
- surface coating (1)
- surfaces (1)
- sutures (1)
- synbones (1)
- synergistic reinforcement (1)
- synthetic hydrogels (1)
- systematic investigations (1)
- tension (1)
- tethering (1)
- thermoresponsive hydrogel (1)
- thiol-ene (1)
- thrombin (1)
- thrombosis (1)
- tibial head depression fracture (1)
- tissue morphogenesis (1)
- topotaxis (1)
- total joint arthroplasty (1)
- total knee arthroplasty (1)
- traction (1)
- tranexamic acid (1)
- transforming growth factor-beta 1 (1)
- transplantation (1)
- tubular constructs (1)
- tumor heterogeneity (1)
- tunable ultra‐thin biphasic membrane (1)
- unidirectional freezing (1)
- vascular biofabrication (1)
- vascular network and hierarchical organized vessels (1)
- zinc (1)
- zonal (1)
- zonal construct (1)
- α-tricalcium phosphate (1)
Institute
- Abteilung für Funktionswerkstoffe der Medizin und der Zahnheilkunde (85) (remove)
Fibrous tissue growth and loss of residual hearing after cochlear implantation can be reduced by application of the glucocorticoid dexamethasone-21-phosphate-disodium-salt (DEX). To date, sustained delivery of this agent to the cochlea using a number of pharmaceutical technologies has not been entirely successful. In this study we examine a novel way of continuous local drug application into the inner ear using a refillable hydrogel functionalized silicone reservoir. A PEG-based hydrogel made of reactive NCO-sP(EO-stat-PO) prepolymers was evaluated as a drug conveying and delivery system in vitro and in vivo. Encapsulating the free form hydrogel into a silicone tube with a small opening for the drug diffusion resulted in delayed drug release but unaffected diffusion of DEX through the gel compared to the free form hydrogel. Additionally, controlled DEX release over several weeks could be demonstrated using the hydrogel filled reservoir. Using a guinea-pig cochlear trauma model the reservoir delivery of DEX significantly protected residual hearing and reduced fibrosis. As well as being used as a device in its own right or in combination with cochlear implants, the hydrogel-filled reservoir represents a new drug delivery system that feasibly could be replenished with therapeutic agents to provide sustained treatment of the inner ear.
Myocardial infarction (MI) induces a complex inflammatory immune response, followed by the remodelling of the heart muscle and scar formation. The rapid regeneration of the blood vessel network system by the attraction of hematopoietic stem cells is beneficial for heart function. Despite the important role of chemokines in these processes, their use in clinical practice has so far been limited by their limited availability over a long time-span in vivo. Here, a method is presented to increase physiological availability of chemokines at the site of injury over a defined time-span and simultaneously control their release using biodegradable hydrogels. Two different biodegradable hydrogels were implemented, a fast degradable hydrogel (FDH) for delivering Met-CCL5 over 24hrs and a slow degradable hydrogel (SDH) for a gradual release of protease-resistant CXCL12 (S4V) over 4weeks. We demonstrate that the time-controlled release using Met-CCL5-FDH and CXCL12 (S4V)-SDH suppressed initial neutrophil infiltration, promoted neovascularization and reduced apoptosis in the infarcted myocardium. Thus, we were able to significantly preserve the cardiac function after MI. This study demonstrates that time-controlled, biopolymer-mediated delivery of chemokines represents a novel and feasible strategy to support the endogenous reparatory mechanisms after MI and may compliment cell-based therapies.
Designing of implant surfaces using a suitable ligand for cell adhesion to stimulate specific biological responses of stem cells will boost the application of regenerative implants. For example, materials that facilitate rapid and guided migration of stem cells would promote tissue regeneration. When seeded on fibronectin (FN) that was homogeneously immmobilized to NCO-sP(EO-stat-PO), which otherwise prevents protein binding and cell adhesion, human mesenchymal stem cells (MSC) revealed a faster migration, increased spreading and a more rapid organization of different cellular components for cell adhesion on fibronectin than on a glass surface. To further explore, how a structural organization of FN controls the behavior of MSC, adhesive lines of FN with varying width between 10 mu m and 80 mu m and spacings between 5 mu m and 20 mu m that did not allow cell adhesion were generated. In dependance on both line width and gaps, cells formed adjacent cell contacts, were individually organized in lines, or bridged the lines. With decreasing sizes of FN lines, speed and directionality of cell migration increased, which correlated with organization of the actin cytoskeleton, size and shape of the nuclei as well as of focal adhesions. Together, defined FN lines and gaps enabled a fine tuning of the structural organization of cellular components and migration. Microstructured adhesive substrates can mimic the extracellular matrix in vivo and stimulate cellular mechanisms which play a role in tissue regeneration.
Bioactive glass (BG) scaffolds are being investigated for bone tissue engineering applications because of their osteoconductive and angiogenic nature. However, to increase the in vivo performance of the scaffold, including enhancing the angiogenetic growth into the scaffolds, some researchers use different modifications of the scaffold including addition of inorganic ionic components to the basic BG composition. In this study, we investigated the in vitro biocompatibility and bioactivity of Cu2+-doped BG derived scaffolds in either BMSC (bone-marrow derived mesenchymal stem cells)-only culture or co-culture of BMSC and human dermal microvascular endothelial cells (HDMEC). In BMSC-only culture, cells were seeded either directly on the scaffolds (3D or direct culture) or were exposed to ionic dissolution products of the BG scaffolds, kept in permeable cell culture inserts (2D or indirect culture). Though we did not observe any direct osteoinduction of BMSCs by alkaline phosphatase (ALP) assay or by PCR, there was increased vascular endothelial growth factor (VEGF) expression, observed by PCR and ELISA assays. Additionally, the scaffolds showed no toxicity to BMSCs and there were healthy live cells found throughout the scaffold. To analyze further the reasons behind the increased VEGF expression and to exploit the benefits of the finding, we used the indirect method with HDMECs in culture plastic and Cu2+-doped BG scaffolds with or without BMSCs in cell culture inserts. There was clear observation of increased endothelial markers by both FACS analysis and acetylated LDL (acLDL) uptake assay. Only in presence of Cu2+-doped BG scaffolds with BMSCs, a high VEGF secretion was demonstrated by ELISA; and typical tubular structures were observed in culture plastics. We conclude that Cu2+-doped BG scaffolds release Cu2+, which in turn act on BMSCs to secrete VEGF. This result is of significance for the application of BG scaffolds in bone tissue engineering approaches.
The reliability of implantable blood sensors is often hampered by unspecific adsorption of plasma proteins and blood cells. This not only leads to a loss of sensor signal over time, but can also result in undesired host vs. graft reactions. Within this study we evaluated the hemocompatibility of isocyanate conjugated star shaped polytheylene oxide-polypropylene oxide co-polymers NCO-sP(EO-stat-PO) when applied to gold surfaces as an auspicious coating material for gold sputtered blood contacting sensors. Quartz crystal microbalance (QCM) sensors were coated with ultrathin NCO-sP(EO-stat-PO) films and compared with uncoated gold sensors. Protein resistance was assessed by QCM measurements with fibrinogen solution and platelet poor plasma (PPP), followed by quantification of fibrinogen adsorption. Hemocompatibility was tested by incubation with human platelet rich plasma (PRP). Thrombin antithrombin-III complex (TAT), beta-thromboglobulin (beta-TG) and platelet factor 4 (PF4) were used as coagulation activation markers. Furthermore, scanning electron microscopy (SEM) was used to visualize platelet adhesion to the sensor surfaces. Compared to uncoated gold sensors, NCO-sP(EO-stat-PO) coated sensors revealed significant better resistance against protein adsorption, lower TAT generation and a lower amount of adherent platelets. Moreover, coating with ultrathin NCO-sP(EO-stat-PO) films creates a cell resistant hemocompatible surface on gold that increases the chance of prolonged sensor functionality and can easily be modified with specific receptor molecules.