Background
For improved outcomes in total knee arthroplasty (TKA) correct implant fitting and positioning are crucial. In order to facilitate a best possible implant fitting and positioning patient-specific systems have been developed. However, whether or not these systems allow for better implant fitting and positioning has yet to be elucidated. For this reason, the aim was to analyse the novel patient-specific cruciate retaining knee replacement system iTotal (TM) CR G2 that utilizes custom-made implants and instruments for its ability to facilitate accurate implant fitting and positioning including correction of the hip-knee-ankle angle (HKA).
Methods
We assessed radiographic results of 106 patients who were treated with the second generation of a patient-specific cruciate retaining knee arthroplasty using iTotal\(^{TM}\) CR G2 (ConforMIS Inc.) for tricompartmental knee osteoarthritis (OA) using custom-made implants and instruments. The implant fit and positioning as well as the correction of the mechanical axis (hip-knee-ankle angle, HKA) and restoration of the joint line were determined using pre- and postoperative radiographic analyses.
Results
On average, HKA was corrected from 174.4 degrees +/- 4.6 degrees preoperatively to 178.8 degrees +/- 2.2 degrees postoperatively and the coronal femoro-tibial angle was adjusted on average 4.4 degrees. The measured preoperative tibial slope was 5.3 degrees +/- 2.2 degrees (mean +/- SD) and the average postoperative tibial slope was 4.7 degrees +/- 1.1 degrees on lateral views. The joint line was well preserved with an average modified Insall-Salvati index of 1.66 +/- 0.16 pre- and 1.67 +/- 0.16 postoperatively. The overall accuracy of fit of implant components was decent with a measured medial overhang of more than 1 mm (1.33 mm +/- 0.32 mm) in 4 cases only. Further, a lateral overhang of more than 1 mm (1.8 mm +/- 0.63) (measured in the anterior-posterior radiographs) was observed in 11 cases, with none of the 106 patients showing femoral notching.
Conclusion
The patient-specific iTotal\(^{TM}\) CR G2 total knee replacement system facilitated a proper fitting and positioning of the implant components. Moreover, a good restoration of the leg axis towards neutral alignment was achieved as planned. Nonetheless, further clinical follow-up studies are necessary to validate our findings and to determine the long-term impact of using this patient- specific system.
Background
The treatment of septic arthritis, caused by either hematogenous seeding, injections, or surgery, can be challenging. Staged reverse shoulder arthroplasty (RSA) with temporary implantation of an antibiotic-loaded spacer is widely accepted but still discussed controversially. This study investigated the shoulder-specific bacterial spectrum, infection control rate, functional outcome, and infection-free survival rate after staged RSA in the mid- to long-term follow-up. It was hypothesized that staged RSA would show a high infection-free survival rate.
Methods
A total of 39 patients treated with staged RSA for primary septic arthritis (n = 8), secondary infection (n = 8), or periprosthetic infection (n = 23) were retrospectively included. The infection control rate was calculated based on cultures taken intraoperatively at spacer removal and RSA implantation. Infection-free survival was defined as no revision due to infection. The minimum follow-up period for functional outcome assessment was 2 years (n = 14; mean, 76 months; range, 31-128 months).
Results
Cutibacterium (26%) and coagulase-negative staphylococci (23%) were the predominant pathogens. The infection control rate was 90%. The cumulative infection-free survival rate was 91% after 128 months. Follow-up examinations showed a mean Constant score of 48 (range, 7-85), a mean QuickDASH (short version of Disabilities of the Arm, Shoulder and Hand questionnaire) score of 40.0 (range, 11.4-93.3), and a mean pain score of 1.6 (range, 0-7).
Conclusion
Staged RSA implantation was confirmed to be a reliable treatment option for primary, secondary, and periprosthetic infections of the shoulder. The infection control rate and infection-free survival rate are satisfactory. However, patients and surgeons must be aware of functional impairment even after successful treatment of infections.
Trotz ständiger Weiterentwicklung der modernen Endoprothetik weist ein künstliches Gelenk auch heute eine begrenzte Haltbarkeit auf. Insbesondere bei der Versorgung jüngerer Patienten mit gestiegener Lebenserwartung wird häufig die Prothesenstandzeit aufgebraucht und ein komplizierter Revisionseingriff notwendig. Hierbei ist die aseptische Prothesenlockerung der häufigste Grund für den Austausch eines Implantates. Das Knochenmark des betreffenden Knochens enthält humane Mesenchymale Stammzellen (hMSC), die zur Aufrechterhaltung und Regeneration des Bindegewebes und des Knochens selbst beitragen. Ob diese Zellen z.B. durch ein Proliferations- oder Differenzierungsdefizit eine Rolle in der Ätiologie einer aseptischen Prothesenlockerung spielen, ist bisher nicht abschließend geklärt.
In der vorliegenden Arbeit wurde die regenerative Kapazität von hMSC von zwei Spendergruppen untersucht und verglichen: Als Wechselgruppe dienten Patienten, bei denen es zu einer aseptischen Prothesenlockerung und der Notwendigkeit eines Revisionseingriffes (Wechseloperation) gekommen war. Patienten, denen primär eine Hüft- oder Kniegelenksendoprothese eingesetzt wurde, bildeten die Kontrollgruppe. Zur Beurteilung der regenerativen Eigenschaften der hMSC wurde zum einen das Wachstums- und Alterungsverhalten in Zellkultur zum anderen die in vitro Differenzierungskapazität untersucht.
Objective
This study aimed to compare a state‐of‐the‐art bioelectrical impedance analysis (BIA) device with two‐point Dixon magnetic resonance imaging (MRI) for the quantification of visceral adipose tissue (VAT) as a health‐related risk factor.
Methods
A total of 63 male participants were measured using a 3‐T MRI scanner and a segmental, multifrequency BIA device. MRI generated fat fraction (FF) maps, in which VAT volume, total abdominal adipose tissue volume, and FF of visceral and total abdominal compartments were quantified. BIA estimated body fat mass and VAT area.
Results
Coefficients of determination between abdominal (r\(^{2}\) = 0.75) and visceral compartments (r\(^{2}\) = 0.78) were similar for both groups, but slopes differed by a factor of two. The ratio of visceral to total abdominal FF was increased in older men compared with younger men. This difference was not detected with BIA. MRI and BIA measurements of the total abdominal volume correlated moderately (r\(^{2}\) = 0.31‐0.56), and visceral measurements correlated poorly (r\(^{2}\) = 0.13‐0.44).
Conclusions
Visceral BIA measurements agreed better with MRI measurements of the total abdomen than of the visceral compartment, indicating that BIA visceral fat area assessment cannot differentiate adipose tissue between visceral and abdominal compartments in young and older participants.
Die Knieendoprothetik verzeichnet in den letzten Jahren steigende Zahlen, was wiederum steigende Zahlen an Revisionen zur Folge hat. Diese Studie hat die Gründe für Revisionen ermittelt. Hierzu wurden 1245 Operationen gesammelt und ausgewertet. Instabilität, Infektion und aseptische Lockerungen stellen die Hauptgründe für eine Revisionsoperation dar. Es wurden zusätzlich verschiedene Zeiträume zwischen Primärimplantation und Revision unterteilt und die jeweiligen Gründe ermittelt.
Background
The role of cement-augmented screw fixation for calcaneal fracture treatment remains unclear. Therefore, this study was performed to biomechanically analyze screw osteosynthesis by reinforcement with either a calcium phosphate (CP)-based or polymethylmethacrylate (PMMA)-based injectable bone cement.
Methods
A calcaneal fracture (Sanders type IIA) including a central cancellous bone defect was generated in 27 synthetic bones, and the specimens were assigned to 3 groups. The first group was fixed with four screws (3.5 mm and 6.5 mm), the second group with screws and CP-based cement (Graftys (R) QuickSet; Graftys, Aix-en-Provence, France), and the third group with screws and PMMA-based cement (Traumacem (TM) V+; DePuy Synthes, Warsaw, IN, USA). Biomechanical testing was conducted to analyze peak-to-peak displacement, total displacement, and stiffness in following a standardized protocol.
Results
The peak-to-peak displacement under a 200-N load was not significantly different among the groups; however, peak-to-peak displacement under a 600- and 1000-N load as well as total displacement exhibited better stability in PMMA-augmented screw osteosynthesis compared to screw fixation without augmentation. The stiffness of the construct was increased by both CP- and PMMA-based cements.
Conclusion
Addition of an injectable bone cement to screw osteosynthesis is able to increase fixation strength in a biomechanical calcaneal fracture model with synthetic bones. In such cases, PMMA-based cements are more effective than CP-based cements because of their inherently higher compressive strength. However, whether this high strength is required in the clinical setting for early weight-bearing remains controversial, and the non-degradable properties of PMMA might cause difficulties during subsequent interventions in younger patients.
Hypophosphatasia (HPP) is a rare, inherited, metabolic disease characterized by tissue‐nonspecific alkaline phosphatase deficiency resulting in musculoskeletal and systemic clinical manifestations. This observational study evaluated the effectiveness of enzyme replacement therapy with asfotase alfa on physical function and health‐related quality of life (HRQoL) among adults with pediatric‐onset HPP who received asfotase alfa for 12 months at a single center (ClinicalTrial.gov no.: NCT03418389). Primary outcomes evaluated physical function with the 6‐minute walk test (6MWT), timed up‐and‐go (TUG) test, Short Physical Performance Battery (SPPB), and handheld dynamometry (HHD). Secondary outcome measures included the Lower Extremity Functional Scale (LEFS), pain prevalence/intensity, and pain medication use; HRQoL was evaluated using the 36‐Item Short‐Form Health Survey version 2 (SF‐36v2). Safety data were collected throughout the study. All 14 patients (11 women) had compound heterozygous ALPL gene mutations and ≥1 HPP bone manifestation, including history of ≥1 fracture. Mean (min, max) age was 51 (19 to 78) years. From baseline to 12 months of treatment, median 6MWT distance increased from 267 m to 320 m (n = 13; p = 0.023); median TUG test time improved from 14.4 s to 11.3 s (n = 9; p = 0.008). Specific components of the SPPB also improved significantly: median 4‐m gait speed increased from 0.8 m/s to 1.1 m/s (n = 10; p = 0.007) and median repeated chair‐rise time improved from 22 s to 13 s (n = 9; p = 0.008). LEFS score improved from 24 points to 53 points (n = 10; p = 0.002). Improvements in HHD were not clinically significant. SF‐36v2 Physical Component Score (PCS) improved after 12 months of treatment (n = 9; p = 0.010). Pain level did not change significantly from baseline to 12 months of treatment. There were significant improvements on chair‐rise time and SF‐36v2 PCS by 3 months, and on TUG test time after 6 months. No new safety signals were identified. These results show the real‐world effectiveness of asfotase alfa in improving physical functioning and HRQoL in adults with pediatric‐onset HPP. © 2020 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.
Der menschliche Körper besitzt Anpassungsmechanismen, die es ihm ermöglichen, sich an verschiedene Belastungssituationen anzupassen. Es gab in letzter Zeit mehrere Hinweise darauf, dass diese Mechanismen durch die Ausschüttung von Zytokinen, bzw. Myokinen durch die betroffenen Zellen selbst ausgelöst werden. In dieser Arbeit wurden die Serumkonzentration von Myostatin, Follistatin, Follistatin-like-3, Interleukin 6, Interleukin 8 und Klotho vor und nach einer kurzen körperlichen Belastung bestimmt. Dabei konnte allerdings keine signifikante Änderung der Konzentrationen nachgewiesen werden, was die Frage aufwirft, ob mesenchymales Gewebe, insbesondere Muskelgewebe, überhaupt über einen klassischen endokrinen Sekretionsmechanismus verfügt.
Osteozyten stehen vermehrt im Fokus als wesentliche Regulatoren der Knochenmineralisierung. Das ähnlich einem neuronalen Netzwerk aufgebaute lakunokanalikuläre Netzwerk der Osteozyten breitet sich im Knochen in drei Ebenen aus. Es wurde in dieser Arbeit ein 3D-Kollagengel-Modell verwendet und dort die Osteoblasten- bzw. Osteozytenzelllinien MLO-A5 und MLO-Y4, sowie humane mesenchymale Stammzellen aus Hüftköpfen eingebettet. Es wurden die optimalen Kulturbedingungen entwickelt und die Zellen über mehrere Wochen kultiviert, beobachtet und mit dem herkömmlichen 2D-Kulturmodell verglichen. MLO-A5 und MLO-Y4 bilden die zelltypischen Zellfortsätze. Die Gele kontrahieren, wenn hMSC und MLO-A5 eingebettet sind, mit MLO-Y4 zeigt sich über den gesamten Kultivierungszeitraum keinerlei Kontraktion der Kollagengele. Die Zellen wurden zudem osteogen differenziert und mit FGF23 und Klotho stimuliert. Es ergaben sich erste Hinweise auf eine FGF23 / Klotho-abhängige Inhibierung der lokalen Mineralisierung in osteogen differenzierten MLO-A5.
Es konnten einige osteogene Marker durch PCR und in den histologischen Schnitten mittels Antikörperfärbungen nachgewiesen werden, eindeutige Expressionsmuster und deren zeitliche Verläufe im Vergleich der osteogenen Differenzierungen und Zugabe von FGF23 und Klotho sind allerdings noch nicht identifizierbar und bedürfen womöglich höherer Fallzahlen und weiterer Untersuchungsmethoden. Insgesamt gesehen erweist sich das System aber als einfach und mit niederschwellig erreichbaren Methoden und Materialien durchzuführen.
Aufgrund des demographischen Wandels mit einer zunehmend älter werdenden Bevölkerung ist die Zahl der Knieprothesen und vor allem auch der Revisionsoperationen in den letzten Jahren deutlich gestiegen. Mit ebenfalls zunehmendem medizinischem Anspruch wurden die bestehenden Prothesenmodelle stetig weiter entwickelt.
Ziel der vorliegenden Studie war es, in einer prospektiv angelegten einfach verblindeten Studie zwei verschiedene Rotating-Hinge-Revisionsprothesen unterschiedlicher Hersteller miteinander zu vergleichen und sie auf ihr klinisches Outcome zu überprüfen.
Von Juni 2012 bis Mai 2013 wurden insgesamt 25 Patienten in die Studie aufgenommen und dann bis zu 12 Monate nach erfolgter Revisionsoperation nachuntersucht. Die Zuteilung der Prothesenarten erfolgte randomisiert, sodass 13 Patienten die Prothese „EnduRo“ und 12 Patienten die Prothese „Endo-Modell“ erhielten. Als Vergleichswerte wurden klinische Scores herangezogen.
In der Untersuchung zeigten beiden Vergleichsgruppen insgesamt eine deutliche Schmerzreduktion sowie eine Funktionsverbesserungen in allen erhobenen Scores. Zwar erreichten die Patienten der Gruppe „Endo-Modell“ etwas höhere Punktwerte, jedoch waren die Unterschiede im Vergleich zur Patientengruppe „EnduRo“ im durchgeführten Zweistichproben-T-Test nicht statistisch signifikant.