Refine
Has Fulltext
- yes (27)
Is part of the Bibliography
- yes (27)
Year of publication
Document Type
- Journal article (20)
- Doctoral Thesis (7)
Keywords
- radiotherapy (27) (remove)
Institute
- Klinik und Poliklinik für Strahlentherapie (16)
- Klinik und Poliklinik für Nuklearmedizin (4)
- Comprehensive Cancer Center Mainfranken (2)
- Institut für diagnostische und interventionelle Neuroradiologie (ehem. Abteilung für Neuroradiologie) (2)
- Neurochirurgische Klinik und Poliklinik (2)
- Pathologisches Institut (2)
- Institut für Anatomie und Zellbiologie (1)
- Institut für Medizinische Strahlenkunde und Zellforschung (1)
- Kinderklinik und Poliklinik (1)
- Klinik und Poliklinik für Hals-, Nasen- und Ohrenkrankheiten, plastische und ästhetische Operationen (1)
Background The precise definition of the post-operative resection status in high-grade gliomas (HGG) is crucial for further management. We aimed to assess the feasibility of assessment of the resection status with early post-operative positron emission tomography (PET) using [\(^{18}\)F]O-(2-[\(^{18}\)F]-fluoroethyl)-L-tyrosine ([\(^{18}\)F]FET). Methods 25 patients with the suspicion of primary HGG were enrolled. All patients underwent preoperative [\(^{18}\)F]FET-PET and magnetic resonance imaging (MRI). Intra-operatively, resection status was assessed using 5-aminolevulinic acid (5-ALA). Imaging was repeated within 72h after neurosurgery. Post-operative [\(^{18}\)F]FET-PET was compared with MRI, intra-operative assessment and clinical follow-up. Results [\(^{18}\)F]FET-PET, MRI and intra-operative assessment consistently revealed complete resection in 12/25 (48%) patients and incomplete resection in 6/25 cases (24%). In 7 patients, PET revealed discordant findings. One patient was re-resected. 3/7 experienced tumor recurrence, 3/7 died shortly after brain surgery. Conclusion Early assessment of the resection status in HGG with [\(^{18}\)F]FET-PET seems to be feasible.
Background:
In recent years attention has focused on \(\gamma\)H2AX as a very sensitive double strand break indicator. It has been suggested that \(\gamma\)H2AX might be able to predict individual radiosensitivity. Our aim was to study the induction and repair of DNA double strand breaks labelled by \(\gamma\)H2AX in a large cohort.
Methods:
In a prospective study lymphocytes of 136 rectal cancer (RC) patients and 59 healthy individuals were ex vivo irradiated (IR) and initial DNA damage was compared to remaining DNA damage after 2 Gy and 24 hours repair time and preexisting DNA damage in unirradiated lymphocytes. Lymphocytes were immunostained with anti-\(\gamma\)H2AX antibodies and microscopic images with an extended depth of field were acquired. \(\gamma\)H2AX foci counting was performed using a semi-automatic image analysis software.
Results:
Distinct increased values of preexisting and remaining \(\gamma\)H2AX foci in the group of RC patients were found compared to the healthy individuals. Additionally there are clear differences within the groups and there are outliers in about 12% of the RC patients after ex vivo IR.
Conclusions:
The \(\gamma\)H2AX assay has the capability to identify a group of outliers which are most probably patients with increased radiosensitivity having the highest risk of suffering radiotherapy-related late sequelae.
Stereotactic LINAC-Radiosurgery for Glomus Jugulare Tumors: A Long-Term Follow-Up of 27 Patients
(2015)
Background
The optimal treatment of glomus jugulare tumors (GJTs) remains controversial. Due to the critical location, microsurgery still provides high treatment-related morbidity and a decreased quality of life. Thus, we performed stereotactical radiosurgery (SRS) for the treatment of GJTs and evaluated the long-term outcome.
Methods
Between 1991 and 2011, 32 patients with GJTs underwent SRS using a linear accelerator (LINAC) either as primary or salvage therapy. Twenty-seven patients (median age 59.9 years, range 28.7-79.9 years) with a follow-up greater than five years (median 11 years, range 5.3-22.1 years) were selected for retrospective analysis. The median therapeutic single dose applied to the tumor surface was 15 Gy (range 11-20 Gy) and the median tumor volume was 9.5 ml (range 2.8-51 ml).
Results
Following LINAC-SRS, 10 of 27 patients showed a significant improvement of their previous neurological complaints, whereas 12 patients remained unchanged. Five patients died during follow-up due to old age or other, not treatment-related reasons. MR-imaging showed a partial remission in 12 and a stable disease in 15 patients. No tumor progression was observed. The actuarial overall survival rates after five, ten and 20 years were 100%, 95.2% and 79.4%, respectively.
Conclusions
Stereotactic LINAC-Radiosurgery can achieve an excellent long-term tumor control beside a low rate of morbidity in the treatment of GJTs. It should be considered as an alternative therapy regime to surgical resection or fractionated external beam radiation either as primary, adjuvant or salvage therapy.
Anisotropy of dose contributions-an instrument to upgrade real time IMRT and VMAT adaptation?
(2016)
Purpose:
To suggest a definition of dose deposition anisotropy for the purpose of ad hoc adaptation of intensity modulated arc therapy (IMRT) and volumetric arc therapy (VMAT), particularly in the vicinity of important organs at risk (OAR), also for large deformations.
Methods:
Beam's-eye-view (BEV) based fluence warping is a standard adaptation method with disadvantages for strongly varying OAR shapes. 2-Step-adaptation overcomes these difficulties by a deeper analysis of the 3D properties of adaptation processes, but requires separate arcs for every OAR to spare, which makes it impractical for cases with multiple OARs. The authors aim to extend the 2-Step method to arbitrary intensity modulated plan by analyzing the anisotropy of dose contributions. Anisotropy was defined as a second term of Fourier transformation of gantry angle dependent dose contributions. For a cylindrical planning target volume (PTV) surrounding an OAR of varying diameter, the anisotropy and the dose-normalized anisotropy were analyzed for several scenarios of optimized fluence distributions. 2-Step adaptation to decreasing and increasing OAR diameter was performed, and compared to a usual fluence based adaptation method. For two clinical cases, prostate and neck, the VMAT was generated and the behavior of anisotropy was qualitatively explored for deformed organs at risk. #
Results:
Dose contribution anisotropy in the PTV peaks around nearby OARs. The thickness of the "anisotropy wall" around OAR increases for increasing OAR radius, as also does the width of 2-Step dose saturating fluence peak adjacent to the OAR K. Bratengeier et al., "A comparison between 2-Step IMRT and conventional IMRT planning," Radiother. Oncol. 84, 298-306 (2007)]. Different optimized beam fluence profiles resulted in comparable radial dependence of normalized anisotropy. As predicted, even for patient cases, anisotropy was inflated even more than increasing diameters of OAR.
Conclusions:
For cylindrically symmetric cases, the dose distribution anisotropy defined in the present work implicitly contains adaptation-relevant information about 3D relationships between PTV and OAR and degree of OAR sparing. For more complex realistic cases, it shows the predicted behavior qualitatively. The authors claim to have found a first component for advancing a 2-Step adaptation to a universal adaptation algorithm based on the BEV projection of the dose anisotropy. Further planning studies to explore the potential of anisotropy for adaptation algorithms using phantoms and clinical cases of differing complexity will follow.
Purpose:
Investigation of a reduced source to target distance to improve organ at risk sparing during stereotactic irradiation (STX).
Methods:
The authors present a planning study with perfectly target-volume adapted collimator compared with multi-leaf collimator (MLC) at reduced source to virtual isocentre distance (SVID) in contrast to normal source to isocentre distance (SID) for stereotactic applications. The role of MLC leaf width and 20–80% penumbra was examined concerning the healthy tissue sparing. Several prescription schemes and target diameters are considered.
Results:
Paddick’s gradient index (GI) as well as comparison of the mean doses to spherical shells at several distances to the target is evaluated. Both emphasize the same results: the healthy tissue sparing in the high dose area around the planning target volume (PTV) is improved at reduced SVID ≤ 70 cm. The effect can be attributed more to steeper penumbra than to finer leaf resolution. Comparing circular collimators at different SVID just as MLC-shaped collimators, always the GI was reduced. Even MLC-shaped collimator at SVID 70 cm had better healthy tissue sparing than an optimal shaped circular collimator at SID 100 cm.
Regarding penumbra changes due to varying SVID, the results of the planning study are underlined by film dosimetry measurements with Agility™ MLC.
Conclusion:
Penumbra requires more attention in comparing studies, especially studies using different planning systems. Reduced SVID probably allows usage of conventional MLC for STX-like irradiations.
Purpose:
To quantify the contribution of penumbra in the improvement of healthy tissue sparing at reduced source‐to‐axis distance (SAD) for simple spherical target and different prescription isodoses (PI).
Method:
A TPS‐independent method was used to estimate three‐dimensional (3D) dose distribution for stereotactic treatment of spherical targets of 0.5 cm radius based on single beam two‐dimensional (2D) film dosimetry measurements. 1 cm target constitutes the worst case for the conformation with standard Multi‐Leaf Collimator (MLC) with 0.5 cm leaf width. The measured 2D transverse dose cross‐sections and the profiles in leaf and jaw directions were used to calculate radial dose distribution from isotropic beam arrangement, for both quadratic and circular beam openings, respectively. The results were compared for standard (100 cm) and reduced SAD 70 and 55 cm for different PI.
Results:
For practical reduction of SAD using quadratic openings, the improvement of healthy tissue sparing (HTS) at distances up to 3 times the PTV radius was at least 6%–12%; gradient indices (GI) were reduced by 3–39% for PI between 40% and 90%. Except for PI of 80% and 90%, quadratic apertures at SAD 70 cm improved the HTS by up to 20% compared to circular openings at 100 cm or were at least equivalent; GI were 3%–33% lower for reduced SAD in the PI range 40%–70%. For PI = 80% and 90% the results depend on the circular collimator model.
Conclusion:
Stereotactic treatments of spherical targets delivered at reduced SAD of 70 or 55 cm using MLC spare healthy tissue around the target at least as good as treatments at SAD 100 cm using circular collimators. The steeper beam penumbra at reduced SAD seems to be as important as perfect target conformity. The authors argue therefore that the beam penumbra width should be addressed in the stereotactic studies.
Solid tumors are complex organ-like structures that consist not only of tumor cells but also of vasculature, extracellular matrix (ECM), stromal, and immune cells. Often, this tumor microenvironment (TME) comprises the larger part of the overall tumor mass. Like the other components of the TME, the ECM in solid tumors differs significantly from that in normal organs. Intratumoral signaling, transport mechanisms, metabolisms, oxygenation, and immunogenicity are strongly affected if not controlled by the ECM. Exerting this regulatory control, the ECM does not only influence malignancy and growth of the tumor but also its response toward therapy. Understanding the particularities of the ECM in solid tumor is necessary to develop approaches to interfere with its negative effect. In this review, we will also highlight the current understanding of the physical, cellular, and molecular mechanisms by which the pathological tumor ECM affects the efficiency of radio-, chemo-, and immunotherapy. Finally, we will discuss the various strategies to target and modify the tumor ECM and how they could be utilized to improve response to therapy.
First‐line treatment of pediatric low‐grade glioma using surgery, radio‐ or chemotherapy fails in a relevant proportion of patients. We analyzed efficacy of subsequent surgical and nonsurgical therapies of the German cohort of the SIOP‐LGG 2004 study (2004‐2012, 1558 registered patients; median age at diagnosis 7.6 years, median observation time 9.2 years, overall survival 98%/96% at 5/10 years, 15% neurofibromatosis type 1 [NF1]). During follow‐up, 1078/1558 patients remained observed without (n = 217), with 1 (n = 707), 2 (n = 124) or 3 to 6 (n = 30) tumor volume reductions; 480/1558 had 1 (n = 332), 2 (n = 80), 3 or more (n = 68) nonsurgical treatment‐lines, accompanied by up to 4 tumor‐reductive surgeries in 215/480; 265/480 patients never underwent any neurosurgical tumor volume reduction (163/265 optic pathway glioma). Patients with progressing tumors after first‐line adjuvant treatment were at increased risk of suffering further progressions. Risk factors were young age (<1 year) at start of treatment, tumor dissemination or progression within 18 months after start of chemotherapy. Progression‐free survival rates declined with subsequent treatment‐lines, yet remaining higher for patients with NF1. In non‐NF1‐associated tumors, vinblastine monotherapy vs platinum‐based chemotherapy was noticeably less effective when used as second‐line treatment. Yet, for the entire cohort, results did not favor a certain sequence of specific treatment options. Rather, all can be aligned as a portfolio of choices which need careful balancing of risks and benefits. Future molecular data may predict long‐term tumor biology.
Purpose
Evaluation of clinical outcome of two-weekly high-dose-rate brachytherapy boost after external beam radiotherapy (EBRT) for localized prostate cancer.
Methods
338 patients with localized prostate cancer receiving definitive EBRT followed by a two-weekly high-dose-rate brachytherapy boost (HDR-BT boost) in the period of 2002 to 2019 were analyzed. EBRT, delivered in 46 Gy (DMean) in conventional fractionation, was followed by two fractions HDR-BT boost with 9 Gy (D90%) two and four weeks after EBRT. Androgen deprivation therapy (ADT) was added in 176 (52.1%) patients. Genitourinary (GU)/gastrointestinal (GI) toxicity was evaluated utilizing the Common Toxicity Criteria for Adverse Events (version 5.0) and biochemical failure was defined according to the Phoenix definition.
Results
Median follow-up was 101.8 months. 15 (4.4%)/115 (34.0%)/208 (61.5%) patients had low-/intermediate-/high-risk cancer according to the D`Amico risk classification. Estimated 5-year and 10-year biochemical relapse-free survival (bRFS) was 84.7% and 75.9% for all patients. The estimated 5-year bRFS was 93.3%, 93.4% and 79.5% for low-, intermediate- and high-risk disease, respectively. The estimated 10-year freedom from distant metastasis (FFM) and overall survival (OS) rates were 86.5% and 70.0%. Cumulative 5-year late GU toxicity and late GI toxicity grade ≥ 2 was observed in 19.3% and 5.0% of the patients, respectively. Cumulative 5-year late grade 3 GU/GI toxicity occurred in 3.6%/0.3%.
Conclusions
Two-weekly HDR-BT boost after EBRT for localized prostate cancer showed an excellent toxicity profile with low GU/GI toxicity rates and effective long-term biochemical control.
Background and Purpose
The standard treatment of glioblastoma patients consists of surgery followed by normofractionated radiotherapy (NFRT) with concomitant and adjuvant temozolomide chemotherapy. Whether accelerated hyperfractionated radiotherapy (HFRT) yields comparable results to NFRT in combination with temozolomide has only sparsely been investigated. The objective of this study was to compare NFRT with HFRT in a multicenter analysis.
Materials and Methods
A total of 484 glioblastoma patients from four centers were retrospectively pooled and analyzed. Three-hundred-ten and 174 patients had been treated with NFRT (30 × 1.8 Gy or 30 × 2 Gy) and HFRT (37 × 1.6 Gy or 30 × 1.8 Gy twice/day), respectively. The primary outcome of interest was overall survival (OS) which was correlated with patient-, tumor- and treatment-related variables via univariable and multivariable Cox frailty models. For multivariable modeling, missing covariates were imputed using multiple imputation by chained equations, and a sensitivity analysis was performed on the complete-cases-only dataset.
Results
After a median follow-up of 15.7 months (range 0.8-88.6 months), median OS was 16.9 months (15.0-18.7 months) in the NFRT group and 14.9 months (13.2-17.3 months) in the HFRT group (p = 0.26). In multivariable frailty regression, better performance status, gross-total versus not gross-total resection, MGMT hypermethylation, IDH mutation, smaller planning target volume and salvage therapy were significantly associated with longer OS (all p < 0.01). Treatment differences (HFRT versus NFRT) had no significant effect on OS in either univariable or multivariable analysis.
Conclusions
Since HFRT with temozolomide was not associated with worse OS, we assume HFRT to be a potential option for patients wishing to shorten their treatment time.