Liquid chromatography has become the gold standard for modern quality control and purity analytics since its establishment in the 1930s. However, some analytical questions remain very challenging even today. Several molecules and impurities do not possess a suitable chromophore for the application of UV detection or cannot be retained well on regular RP columns. Possible solutions are found in derivatization procedures, but they are time consuming and can be prone to errors. In order to detect non chromophore molecules underivatized, the concept of aerosol based universal detection was established with the introduction of the evaporative light scattering detector (ELSD) in the 1970s and the charged aerosol detector (CAD) followed in 2002. These two challenging fields – polar and non chromophore molecules – are tackled in this thesis.
An overview of applications of the CAD in the literature and a comparison to its aerosol based competitors and MS is presented, emphasizing on its high sensitivity and robustness. Parameters and techniques to overcome the drawbacks of CAD, such as the use of gradient compensation or adjusted evaporation temperatures are discussed. A consideration of aspects and drawbacks of data transformation such as the integrated power function value (PFV) in the GMP environment is performed.
A method for the fatty acid analysis in polysorbate 80 that was developed on HPLC CAD was transferred to UHPLC CAD. Time and eluent savings of over 75% and 40%, respectively, as well as ways to determine the optimal CAD parameters resulted from this investigation. The evaporation temperature was determined as the most crucial setting, which has to be adjusted with care. Optimal signal to noise ratios are found at a compromise between maintaining analyte signal and reducing background noise. The incorporation of semi volatile short chain fatty acids enabled the observation of differences based on volatility of the analyte. E.g. for semi volatiles, an improved linearity by means of adjusting the PFV is achieved at values below 1.0 instead of at elevated PFVs.
Using sugars and sugar related antibiotics, a proof-of-concept was given that artificial neural networks can describe correlations between the structure and physicochemical properties of molecules and their response in CAD. Quantitative structure property relationships obtained by design of experiment approaches were able to predict the response of unseen substances and yielded insights on the response generation of the detector, which heavily relies on the formed surface area of the dried particle. Further work can substantiate upon these findings, eventually building a library of diverse eluent compositions, analytes and settings.
In order to cope with a chromatographically challenging substances, the application of ion pairing reversed phase chromatography coupled to low wavelength UV detection has been shown as a possible approach for the amino acid L asparagine. A method capable of compendial purity analysis in one single HPLC approach, thus making the utilization of the semi quantitative TLC-ninhydrin analysis obsolete, resulted from this. One cyclic dipeptide impurity (diketoasparagine) that was formerly not assessed, could be identified in several batches and added to the monograph of the Ph.Eur.
Studying ibandronate sodium with CAD and ELSD, it was found that randomly occurring spike peaks represent a major flaw of the ELSD when high sample load is present. The research with this non chromophore bisphosphonate drug furthermore shed light on possible drawbacks of mixed mode chromatography methods and ways to overcome these issues. Due to strong adsorption of the analyte onto the column, over ten injections of the highly concentrated test solution were found to be necessary to ensure reproducible peak areas. Preconditioning steps should thus be evaluated for mixed mode approaches during method development and validation.
Last, using a ternary mixed mode stationary phase coupled to CAD, a method for the impurity profiling of pamidronate disodium, also applicable to the assessment of phosphate and phosphite in four other bisphosphonate drugs, has been developed. This represents a major advantage over the Ph.Eur. impurity profiling of pamidronate, which requires two different methods, one of which is only a semi quantitative TLC approach.
The stability of Trp in pure solutions and in parenteral AA formulations was evaluated with regard to typically used manufacturing processes, storage conditions and primary packaging. Therefore, thorough stability studies on Trp solutions were conducted beforehand. The applied stressing method, i.e. steam sterilization by autoclave, are chemically seen relatively mild but showed to be efficient to induce Trp degradation in the presence of oxygen. Subsequent identification, separation and characterization were challenging due to similar substance properties, numerous stereoisomers and pairs of diastereomers found amongst them. However, the identified o-aminoacetophenone compounds, Kyn and NFK, are associated with photo reactivity and have photo-oxidizing properties. Thus, best possible protection from UV-light, together with strict oxygen expulsion, are the most important criteria to impede Trp degradation after autoclaving.
The identification of Trp degradation products was assisted by the compilation of a substance library, which included manifold reported and chemically plausible Trp degradation substances. The substances were classified for priority and their early or late-stage occurrence. The large number of possible substances and stereoisomers was narrowed down with the information retrieved from LC-UV/MS experiments. However, final identification was achieved by the synthesis of proposed substances as references. The following eight substances were characterized as Trp degradation substances: Kyn, NFK and three pairs of diastereomers R,R/R,S DiOia, R,R/R,S Oia and cis/trans PIC. Fig. 33 shows the proposed degradation pathway and demonstrates the close chemical relationship, which may be an explanation for the conversion of some substances into each other during the storage period. The proposed pathway brings together the results of different Trp stability and stressing studies, respectively [89, 94, 97, 98, 103, 133]. To our knowledge, the simultaneous formation of the identified degradation substances has not been reported before and especially not under the stressing conditions applied.
The application of a traditional RP-HPLC method was compared to two developed IP-HPLC methods and a RP-HPLC methods using a modified perfluorinated column. Orthogonal analyses methods and especially the combination of UV and MS detection are necessary in order to indicate potentially undetected degradation substances. Main evaluation criteria were the separation performance, analyses time, reproducibility and feasibility. The best results upon assessment of all Trp degradation products, in both; pure Trp solutions and pharmaceutical formulations, were obtained by a traditional RP-HPLC. The optimized method was validated according to ICH guidelines Q2(R1) and meets the criteria of a stability-indicating HPLC-UV method. The validated method has a sufficient separation performance with an adequate selectivity indicating the Trp degradation substances next to each other and next to other AAs in finished pharmaceutical formulations.
The detailed knowledge of Trp degradation and the method presented may be transferred practically to the pharmaceutical industry processing Trp-containing products. In general, the findings might contribute to the quality management of such pharmaceutical products during
manufacturing and storage. Additionally, the study results provide basic information for the establishment of an impurity consideration following the ICH guidelines Q3B (R2) (impurities in new drug products) for products containing Trp. However, further development of the method applying more sophisticated detectors or more potent HPLC techniques like e.g. UHPLC and the implication of more sensitive (MS) detectors like ToF-MS would be advantageous with regard to economic and practical aspects.